• Title/Summary/Keyword: motion graph

Search Result 95, Processing Time 0.025 seconds

A Study of Mechanism Synthesis of One-Degree-of-Freedom Planar Linkages with Revolute Joints (회전대우를 갖는 1자유도 평면기구의 기구합성에 관한 연구)

  • 조선휘;신동원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1330-1341
    • /
    • 1993
  • The kinematic synthesis deals with the systematic design of mechanisms for a given performance. The area of synthesis may be grouped into two categories to determine the type and to size the dimensions of a mechanism for a specified task. In this paper, using a database of mechanisms a designer can determine the type of mechanism conveniently and design equations are automatically generated for a given input performance. The solving method of design equations utilizes an optimization routine to obtain roots effectively. The linkages of 4, 6, and 8bars with revolute joints are considered in this study but may be extended to linkages of more bars.

Motion Activity Detection using Wireless 3-Axis Accelerometer Sensor for Elder and Feeble Person (노약자 보호를 위한 무선 3축 가속도 센서를 이용한 움직임 검출 시스템)

  • Choi, Jeong-Yeon;Jung, Sung-Boo;Lee, Hyun-Kwan;Eom, Ki-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.565-568
    • /
    • 2009
  • This paper proposes an monitoring system of elder and feeble person's motion activity using an object's motion activity data. The proposed system used wireless 3-axis sensor module, product by Freescale(Wireless Sensing Triple Axis Reference Design Board (ZSTAR)). We distribute sensing data into three classes using Neural Network System SVM. We find performance of proposed system that simulate some case about walk, past walk, fallen. Classify result data and graph of sensing data present succes rate 80%.

  • PDF

Trajectory Rectification of Marker using Confidence Model (신뢰도 모델을 이용한 마커 궤적 재조정)

  • Ahn, Junghyun;Jang, Mijung;Wohn, Kwangyun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.8 no.3
    • /
    • pp.17-23
    • /
    • 2002
  • Motion capture system is widely used nowadays in the entertainment industry like movies, computer games and broadcasting. This system consist of several high resolution and high speed CCD cameras and expensive frame grabbing hardware for image acquisition. KAIST VR laboratory focused on low cost system for a few years and have been developed a LAN based optical motion capture system. But, by using low cost system some problems like occlusion, noise and swapping of markers' trajectory can be occurred. And more labor intensive work is needed for post-processing process. In this thesis, we propose a trajectory rectification algorithm by confidence model of markers attached on actor. Confidence model is based on graph structure and consist of linkage, marker and frame confidence. To reduce the manual work in post-processing, we have to reconstruct the marker graph by maximizing the frame confidence.

  • PDF

Wireless Measurement of Human Motion Based on PDA (PDA기반 인체동작 무선계측)

  • Lee, Myong-Ho;Kim, Nam-Jin;Lee, Hwun-Jae;Jin, Gae-Whan;Lee, Sam-Ual;Lee, Jun-Hang;Lee, Sang-Bock;Lee, Tae-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • In this study, wireless measurement technique for human motion was developed to monitor movement disorder patients during their daily life. MICA, TinyOS, and nesC, developed by UC Berkeley, were used as wireless sensor, its software platform, and programming language. The human motion data, generated by two axial accelerometer(ADXL202) was transmitted to PDA(iPaq3630) by 916Mhz short range communication chip(TR1000). It could be stored at PDA by simple Windows CE programming. To test the developed device, it was attached at human chest and the acquired data was shown as a graph during his motion of sitting, standing, and lying. The result showed that human motion could be logged without any hooking and constraints. Therefore, this device can be used to monitor patient's movement disorder and activity of daily life(ADL).

  • PDF

ROLLING STONES WITH NONCONVEX SIDES II: ALL TIME REGULARITY OF INTERFACE AND SURFACE

  • Lee, Ki-Ahm;Rhee, Eun-Jai
    • Journal of the Korean Mathematical Society
    • /
    • v.49 no.3
    • /
    • pp.585-604
    • /
    • 2012
  • In this paper we consider the evolution of the rolling stone with a rotationally symmetric nonconvex compact initial surface ${\Sigma}_0$ under the Gauss curvature flow. Let $X:S^n{\times}[0,\;{\infty}){\rightarrow}\mathbb{R}^{n+1}$ be the embeddings of the sphere in $\mathbb{R}^{n+1}$ such that $\Sigma(t)=X(S^n,t)$ is the surface at time t and ${\Sigma}(0)={\Sigma}_0$. As a consequence the parabolic equation describing the motion of the hypersurface becomes degenerate on the interface separating the nonconvex part from the strictly convex side, since one of the curvature will be zero on the interface. By expressing the strictly convex part of the surface near the interface as a graph of a function $z=f(r,t)$ and the non-convex part of the surface near the interface as a graph of a function $z={\varphi}(r)$, we show that if at time $t=0$, $g=\frac{1}{n}f^{n-1}_{r}$ vanishes linearly at the interface, the $g(r,t)$ will become smooth up to the interface for long time before focusing.

A Study on the Automotive Suspension System for Energy Efficiency (에너지 절감형 자동차용 현가장치에 관한 연구)

  • 소상균
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.100-107
    • /
    • 2001
  • The main goals of the automotive suspension systems are to isolate roadway unevenness from the tire and to improve vehicle stability. To overcome the performance limitation of the passive systems the active systems which completely replace the passive spring and damper elements with a force generating actuator has been studied. However, application of the system has been limited because it has required a significant amount of power. Recently, alternative systems which retain passive elements but include active elements have been developed to reduce the power required. Those systems are mostly focused on the control system which compresses the spring-damper directly. In this study, a new type of power efficient control system which makes the spring-damper unit slide in side way is studied. After constructing the control system including dynamic modeling and motion control, two types of alternative control systems are compared in view of power consumption and dynamic attitudes such as roll responses as well as heave responses. Also, a half car bond graph model is developed to show clearly the significant differences in performances between two control systems.

  • PDF

Detection of Objects Temporally Stop Moving with Spatio-Temporal Segmentation (시공간 영상분할을 이용한 이동 및 이동 중 정지물체 검출)

  • Kim, Do-Hyung;Kim, Gyeong-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.1
    • /
    • pp.142-151
    • /
    • 2015
  • This paper proposes a method for detection of objects temporally stop moving in video sequences taken by a moving camera. Even though the consequence of missed detection of those objects could be catastrophic in terms of application level requirements, not much attention has been paid in conventional approaches. In the proposed method, we introduce cues for consistent detection and tracking of objects: motion potential, position potential, and color distribution similarity. Integration of the three cues in the graph-cut algorithm makes possible to detect objects that temporally stop moving and are newly appearing. Experiment results prove that the proposed method can not only detect moving objects but also track objects stop moving.

Quick Inspection of Virus Using Urban-Map and K-d Tree based Graph Construction and Efficient Patient Movement Route System (바이러스의 빠른 검사를 위한 도시 맵과 K-d 트리 기반의 그래프 구축과 효율적인 환자 이동 경로 시스템)

  • Shin, Young Chan;Moon, Seong-Hyeok;Kim, Donghui;Kim, Jong-Hyun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.01a
    • /
    • pp.383-386
    • /
    • 2022
  • 본 논문에서는 COVID-19와 같은 위급한 상황에서 바이러스 검사를 빠르게 진행하기 위한 K-d 트리 기반의 그래프 구축과 환자 이동 경로 시스템을 제안한다. 가상환경에서 활용되는 대표적인 길 찾기 알고리즘은 A*나 NavMesh 자료구조는 정해진 정적 이동 경로만을 안내하려는 방법이기 때문에 가상환경에서 NPC를 제어할 때는 효율적이지만, 실제 환경에 적용하여 문제를 풀기에는 충분하지 않다. 특히, 빠른 바이러스 검사를 받기 위해서는 짧은 거리만을 이용하는 게 아닌, 실제 도로 교통상황, 병원의 크기, 환자 이동 수, 환자 처리 시간 등 고려해야 할 상황들이 많다. 본 논문에서는 위에서 언급한 다양한 속성들과 이를 이용한 최적화 함수를 모델링하여, 실제 도시 맵에서 바이러스 검사를 빠르고 효율적으로 제어할 수 있는 프레임워크를 제안한다.

  • PDF

Wheelchair-based New Millennium Health Gymnastics: Muscle Activity and Upper Limbs Coordination by Elbow Exercise Velocity (휠체어 새천년 건강체조의 팔꿈치 운동속도에 따른 상지협응과 근활성도 변화)

  • Lee, Kang-Jin;Kim, Tack-Hoon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.2
    • /
    • pp.161-170
    • /
    • 2014
  • PURPOSE: This study concerns the wheelchair-based rehabilitation of elderly people, investigating muscle activity and coordination of upper limbs during wheelchair-based new millennium health gymnastics with varying elbow exercise velocity. METHODS: Twelve elderly people participated in new millennium gymnastics twice per week during 12-weeks. The group was separated into 0.4, 1.0, and 1.6 Hz groups (controlled by the metronome speed). Range of motion was measured by electrogoniometer, electromyography signals used root mean square values. The data application was normalized using reference voluntary contraction (%RVC). Upper limb (wrist and elbow joint) data gathered while standing up after the "falling on hips" was investigated in terms of coordination of angle-angle plots. One-way ANOVA, paired t-test and Scheffe's post hoc comparisons, were used for statistical analyses. RESULTS: There were results taken before and after the experiments. The results demonstrated a significant improvement in the triceps brachii and flexor carpi radialis of the 0.4 Hz group (p<.05). There was significant difference in the triceps brachi of the 1 Hz group. No significant differences were found in all muscles of the 1.6 Hz group. Muscle co-activation indexes of the 0.4 Hz group were larger than the others. The 0.4 Hz graph was turning point synchronized clockwise. The 1 Hz graph was out of phase with the negative slope. The 1.6 Hz graph was turning point synchronized counterclockwise, and uncontrolled factor phase was offset on angle-angle plots. CONCLUSION: It is found that improvement of muscle activity and upper limbs coordination of elderly people using wheelchair-based new millennium gymnastics is optimal with elbow exercise velocity with a frequency of 0.4 Hz.

Comparison vibration characteristics of several wireless endodontic handpieces (여러 근관치료용 무선 핸드피스의 진동양상 비교)

  • Lee, Bo-Kyung;Lee, Yoon;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.2
    • /
    • pp.81-89
    • /
    • 2022
  • Purpose: Wireless endodontic handpieces (WEH) are widely used in dental clinics due to their convenience and portability. This study aimed to compare the vibration magnitudes and patterns generated by five WEH. Materials and Methods: Vibration acceleration of five WEH (X-Smart IQ, E connect S, Endo A Class, ENDOIT, and TRAUS ENDO) in the rotary and reciprocating motion was measured with accelerometer The average vibration acceleration was analyzed using the t-test, Welch's ANOVA test, and Dunnett T3 test at P < 0.05. Results: In all WEH, the average vibration acceleration in reciprocating motion was significantly higher than that in rotary motion (P < 0.001). In rotary motion, repeated vibration graphs of constant amplitude were obtained without sudden changes in the magnitude of vibration, and the average vibration acceleration value was high in the order of X Smart IQ, Endo A Class, ENDOIT, E Connect S, and TRAUS ENDO (P < 0.001), there was no statistically significant difference between X Smart IQ and Endo A Class. In reciprocating motion, a vibration graph was obtained in which large amplitude peaks appear at specific points within one cycle are repeated. The average vibration acceleration value was highest in the order of X Smart IQ, E Connect S, Endo A class, ENDOIT, and TRAUS ENDO (P < 0.001). Conclusion: Regardless of the type of WEH, greater vibration occurred in the reciprocating motion than in the rotary motion (P < 0.001). In the reciprocating motion, there was a difference in vibration for all handpieces (P < 0.001).