Experimental Study on CO2 Diffusivity in Cementitious Materials

  • Jung, Sang-Hwa;Lee, Myung-Kue;Kim, Jee-Sang
    • Corrosion Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.69-74
    • /
    • 2005
  • The carbonation of concrete is one of the major factors that cause durability problems in concrete structures. The rate of carbonation depends largely upon the diffusivity of carbon dioxide in concrete. The purpose of this study is to identify the diffusion coefficients of carbon dioxide for various concrete mixtures. To this end, several series of tests have been planned and conducted. The test results indicate that the diffusion coefficient increases with the increase of water-cement ratio. The diffusion coefficient decreases with the increase of relative humidity at the same water-cement ratio. The diffusion of carbon dioxide reached the steady state within about five hours after exposure. The content of aggregates also influences the diffusivity of carbon dioxide in concrete. It was found that the diffusion coefficient of cement paste is larger then that of concrete or mortar. The quantitative values of diffusivity of carbon dioxide in this study will allow more realistic assessment of carbonation depth in concrete structures.

Evaluation of anti-rust properties of mortar with functionality anti-rust agent (기능성 방청혼화제 혼입율 변화에 따른 모르타르의 방청성능 평가)

  • Kim, Sang-Sup;Lee, Myung-Ho;Yoon, Won-Geun;Jang, Deok-Bae;Han, Min Cheol;Han, Cheon Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.104-105
    • /
    • 2014
  • In this study, fundamental properties of mortar with the variation of dosage of anti-rust agent has been tested to evaluate the effect of the anti-rust agent. Dosage of anti-rust agent was fixed as 0,3,6,9%, respectively. The variation of the flow, compressive strength and diffusion speed of chloride ion has been tested to evaluate the effect of the anti-rust agent. Results showed that flow has been smally increased. For the compressive strength, compressive strength increased with the increase of dosage of agent. For the diffusion speed of chloride, the speed decreased with the increase of dosage of the anti-rust agent. For the overall consideration, it could be identified that when the dosage of anti-rust agent was fixed as 3-6%, the mortar showed the optimum performances.

  • PDF

A Study on the Analysis application of Repairing Mortar Using Multi-functional Slag Aggregate (다기능성 슬래그 골재를 이용한 보수모르타르의 현장 적용성 평가에 관한 실험적 연구)

  • Park Sang Hun;Nam Ki Sui;Lee Sang Uk;Cho Sung Hyun;Bae Kee Sun;Oh Sang Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.285-288
    • /
    • 2005
  • This paper is an experimental study on applicability of repairing mortar using multi-functional slag aggregate. In this study, automatic construction machinery system were adapted, and their performance were evaluated by the using of those systems. In order to verify the effect of multi-functional aggregate, two kinds of aggregate were used and compared of their physical properties. The results indicate that multi-functional aggregate appears good physical properties such as durability, permeability coefficient.

  • PDF

An Experimental Study on the Strength and Permeability Characteristics of Repair Mortar (보수용 모르타르의 강도 및 투과특성에 관한 연구)

  • Paik, Shin-Won
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.105-109
    • /
    • 2003
  • Structure surfaces damaged due to many causes are repaired by several special mortars. But wide studies about the permeability of these mortars were rarely conducted. In this study compressive strength test, flexural strength test and bond strength test of these mortars were conducted. And chloride ion penetration test was also conducted to explore the permeability charcteristics of selected repair mortars. This test was carried out following the standard ASTM C1202-91. Colouriemtric penetration depth can be drawn from these test results using a relationship equation between colourimetric penetration depth and charge passed which C. Andrade suggested. Diffusion coefficient can be calculated by CTH rapid method. To the end, the present study can provide a firm base for the application of repair mortars to concrete structures.

Effects of Moisture Absorption Coefficient of Alkali-Activated Slag-Red Mud Cement on Efflorescence (알칼리활성화 슬래그-레드머드 시멘트 모르타르의 흡수계수가 백화발생에 미치는 영향)

  • Kang, Hye Ju;Kim, Byeong gi;Kim, Jae Hwan;Kang, Suk Pyo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.130-131
    • /
    • 2016
  • In this study, moisture absorption coefficient and efflorescence properties of Ordinary Portland cement and alkali-activated slag cement mortar were assessed according to their red mud substitution ratio. Tests were conducted to determine the cause of efflorescence, which is a significant obstacle to the recycling of red mud as a sodium activator in alkali-activated slag cement, and to find a method to control efflorescence.

  • PDF

The Evaluation of Durability Performance in Mortar Curbs Containing Activated Hwangtoh (활성 황토를 혼입한 모르타르 기반 경계석의 내구성능 평가)

  • Kwon, Seung-Jun;Kim, Hyeok-Jung;Yoon, Yong-Sik
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.520-527
    • /
    • 2020
  • Hwangtoh is the rich resource that accounts for about 15.0% of the domestic soil, and can be used as the admixture of concrete with Pozzolan characteristics if activated by rapidly freezing after burning with high temperature. In this study, the mortar curbs containing active hwangtoh were produced, based on the mixture for the mortar curbs sold on the market. The substitution rate of active hwangtoh were considered 10.0% and 25.0%, and the test items were selected to compressive and flexural strength tests, freezing/thawing resistance tests, accelerated carbonation tests, and accelerated chloride diffusion tests. In the results of the mechanical performance, it was showed that the highest strength was evaluated in OPC mixture, and the increase in strength was small by the increase of age, which was believed to be due to the fact that most of the strength in each mixture was created in three days of steam curing. The results of the freezing/thawing tests for 28 aged days showed the reduction rate of compressive strength was 85.0% or higher for all specimen, meeting the criteria presented. The accelerated carbonation tests were carried out on the specimen at 28 days of age, and the results showed that the mortar with active hwangtoh had lower carbonation resistance performance than mortar with OPC. The passed charge of each mixture was assessed in accordance with ASTM C 1202 on 28 and 91 aged days. The OPC mixture had "Low" rate and the mortar with active hwangtoh had "Moderate" rate. So it was thought that the mortar with active hwangtoh had appropriate resistance performance for chloride attack.

Evaluation of Reinforced Materials and Epoxy Resins for Adhesion Repairing-Reinforced of RC Construction (RC구조물 접착 보수$\cdot$보강용 에폭시수지 및 보강재료의 재료특성 평가)

  • Park Yong-Kyu;Joo Eun-Hi;Lee Gun-Cheol;Byun Hang-Yong;Woo Jong-Wan;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.183-186
    • /
    • 2005
  • This study investigates material properties of epoxy resins and reinforced materials for adhesion repairing-reinforced of RC construction. According to the test. elasticity modulus of mortar indicated 16-26(GPa) and that of concrete was 18-27(GPa). It became decreased as mixture proportion, W/C and fluidity of both mortar and concrete increased In addition the elasticity modulus of epoxy resins exhibited around 45.3-220(GPa), while that of steel plate and Carbon Bar indicated 338(GPa) and 34.1 (GPa), respectively. It is obvious that individual materials had big different value of elasticity modulus. Meanwhile, thermal expansion coefficients of mortar was 10-13 ${\mu}\varepsilon$ /$^{\circ}C$ and that of concrete was 9-11 $\mu \varepsilon$ /$^{\circ}C$ The increase of mixture Voportion and W/C resulted in lower value of thermal expansion coefficients and the increase of flow and slump exhibited slightly higher value. The epoxy resin indicated 41-54 ${\mu}\varepsilon$ /$^{\circ}C$ which is 4-5 times larger value than concrete and steel plate and Carbon Bar was 11.93 ${\mu}\varepsilon$ /$^{\circ}C$ and -1.68 ${\mu}\varepsilon$ /$^{\circ}C$ respectively. Hence, the adhesion strength of the epoxy resins should be considered before it is used in field condition, due to different thermal expansion coefficient of each material.

  • PDF

A study on the fire resistance characteristics of mud flat mortar (갯벌모르타르의 내화성능에 관한 실험적 연구)

  • Yang, Seonghwan;Kim, Huidoo
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.4
    • /
    • pp.589-596
    • /
    • 2015
  • As urbanization progressed along with quantitative expansion of the construction industry, concrete has developed diversely as a material that is the most extensively used in the construction industry. However, aggregate resources that are an essential element of concrete production are gradually being depleted and the phenomenon of aggregate shortage has been intensifying due to the reinforcement of regulations on environmental issues. Therefore, in the present study, environment friendly mortar was made by replacing aggregate with mud that is dumped when dredging sand is dumped. To identify the dynamic characteristics of the mortar and to identify its fire resistance efficiency, the mortar was heated and its residual compressive strength was measured. In the results, the residual compressive strength values of MM1, MM2, and MM3 were 45%, 95%, and 57.7% respectively and the mix MM2 showed the highest fire resistance efficiency.

Fundamental Properties and Radioactivity Shielding Characteristics of Mortar Specimen Utilizing CRT Waste Glass as Fine Aggregate (폐 브라운관(CRT) 유리를 잔골재로 대체한 모르타르 시험체의 기초 물성 및 방사선 차폐 특성)

  • Choi, Yoon-Suk;Kim, Il-Sun;Choi, So-Yeong;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.163-170
    • /
    • 2019
  • In recent years, various types of industrial wastes are rapidly increasing with the development of high-tech industries. Specially, high-density waste glass of CRT TV containing heavy metals are buried or disposed of due to reprocessing costs and environmental pollution problems. Thus, more basic research is needed to recycle waste such as CRT waste glass such. In this study, the fundamental properties and radiation shielding performance of mortar specimens substituted CRT waste glass as a fine aggregate were analyzed and their application to shielding materials was evaluated. According to the results, the bulk density of mortar specimen replaced with CRT waste glass was increased and the compressive strength and flexural strength were decreased. Meanwhile, the CRT waste glass substitute specimen containing a large amount of lead component showed a higher shielding performance than the general mortar specimen. Especially, the linear attenuation coefficient of CRT waste glass in $122KeV{\cdot}^{57}Co$ of the low energy field was 2.5 times higher than that of normal specimen.

A Study on the Estimating the Ultra-High Strength Concrete using Rock Test Hammer (Rock Test Hammer를 사용한 초고강도 콘크리트 강도추정에 관한 기초적 연구)

  • Nam, Kyung-Yong;Kim, Seong-Deok;Choi, Suk;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.3
    • /
    • pp.229-237
    • /
    • 2019
  • This study examines the estimation of strength through a ultra-high strength concrete mock-up specimen using the rock compressive strength test hammer. According to the test result, the commonly used strength estimation formulae showed differences among them when the data of this test were applied. In additional, it show that these formulae underestimated the actual measurements further when the compressive strength was 30MPa or greater and deviated the distribution range of actual measurements in all strength ranges. The rock test hammer showed a higher correlation than type N Schmidt hammer regardless of the direction of hit for each type of W/B and the inclusion of coarse aggregate, and mortar showed a little higher correlation than concrete. As a result, it can be suggested that the coefficient of variation and the standard deviation of the mortar(2.26%/1.36) are lower than those of the concrete(4.06%/2.5), and the smaller the size of the coarse aggregate, the smaller the coefficient of variation and the more accurate the value.