• Title/Summary/Keyword: monitoring measurement system

Search Result 1,550, Processing Time 0.032 seconds

Determination of Combustion Propagation Velocity of Thermite Reaction Mixture Using Continuous VOD Measurement System (연속적 폭굉속도 측정 시스템을 이용한 테르밋 반응 혼합물의 연소전파속도 측정에 관한 연구)

  • Kim, Min-Seong;Kang, Hyeong-Min;Jeong, Sang-Sun;Jeong, Yun-Yeong;Park, Hoon;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.33 no.3
    • /
    • pp.21-28
    • /
    • 2015
  • The objective of this study is to develop a method for monitoring continuously the combustion propagation behavior of commercial thermite reaction mixtures using conventional continuous VOD (velocity of detonation) system. In order to monitor the combustion front propagation with elapsed time during thermite reaction, the VOD system employs two types of commercial VOD probes and one self-made probe: VOD PROBEROD-OS, VOD PROBEROD-HS and VOD PROBEROD-ES, respectively. Among the probes, the only self made VOD PROBEROD-ES successfully demonstrates the velocity of combustion propagation (VOC) with elapsed time. It was found that VOC of the thermite reaction mixture inside a steel tube has been reached around 200m/s within 100mm distance from the ignition and dramatically increased up to about twice the speed of sound in the range between 100mm and 300mm distance. Finally the VOC reached up to around 800m/s. This results imply that it is necessary to use over 300mm long cartridge of thermite reaction mixture in order to achieve normal VOC of the mixture.

Development of Exercise Analysis System Using Bioelectric Abdominal Signal (복부생체전기신호를 이용한 운동 분석 시스템 개발)

  • Gang, Gyeong Woo;Min, Chul Hong;Kim, Tae Seon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.183-190
    • /
    • 2012
  • Conventional physical activity monitoring systems, which use accelerometers, global positioning system (GPS), heartbeats, or body temperature information, showed limited performances due to their own restrictions on measurement environment and measurable activity types. To overcome these limitations, we developed a portable exercise analysis system that can analyze aerobic exercises as well as isotonic exercises. For bioelectric signal acquisition during exercise, waist belt with two body contact electrodes was used. For exercise analysis, the measured signals were firstly divided into two signal groups with different frequency ranges which can represent respiration related signal and muscular motion related signal, respectively. After then, power values, differential of power values, and median frequency values were selected for feature values. Selected features were used as inputs of support vector machine (SVM) to classify the exercise types. For verification of statistical significance, ANOVA and multiple comparison test were performed. The experimental results showed 100% accuracy for classification of aerobic exercise and isotonic resistance exercise. Also, classification of aerobic exercise, isotonic resistance exercise, and hybrid types of exercise revealed 92.7% of accuracy.

Generation of calibration standard gases using capillary gas divider: uncertainty measurement and method validation (다중 모세관을 이용한 교정용 표준가스의 제조: 불확도와 유효성 평가)

  • Lee, Sangyun;Hwang, Eun-Jin;Jung, Hye-Ja;Lee, Kwang-Woo;Chun, Ki-Joon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.369-375
    • /
    • 2006
  • Calibration gas mixtures were prepared using dynamic volumetric method according to ISO 6145-5 and the uncertainty was evaluated. Ten identical capillaries with 0.25 mm in inner diameter and 50 cm in length were applied in this system. Dilution ratio of parent gas was determined by the number of capillaries that passes parent gas and that passes balance gas through. Capillaries were made of Teflon which had good chemical stability against adsorption of gaseous substances. Mechanical valves were introduced in this system in order to minimize the thermal effect of solenoid valves. Concentration of prepared gases were compared with master grade standard gases in cylinders made by RiGAS Co. and calibration of the instrument were completed using comparison method according to ISO 6143. Experimental results showed that the coefficient of variance of diluted oxygen standard gases showed less then 0.2% in most dilution range, that of diluted hydrogen sulfide standard gases showed less then 1.0%. Therefore, it is proven that the standard gases prepared by this system are appropriate to be used as a calibration standards in ambient monitoring, etc.

무령왕릉보존에 있어서의 지질공학적 고찰

  • 서만철;최석원;구민호
    • Proceedings of the KSEEG Conference
    • /
    • 2001.05b
    • /
    • pp.42-63
    • /
    • 2001
  • The detail survey on the Songsanri tomb site including the Muryong royal tomb was carried out during the period from May 1 , 1996 to April 30, 1997. A quantitative analysis was tried to find changes of tomb itself since the excavation. Main subjects of the survey are to find out the cause of infiltration of rain water and groundwater into the tomb and the tomb site, monitoring of the movement of tomb structure and safety, removal method of the algae inside the tomb, and air controlling system to solve high humidity condition and dew inside the tomb. For these purposes, detail survery inside and outside the tombs using a electronic distance meter and small airplane, monitoring of temperature and humidity, geophysical exploration including electrical resistivity, geomagnetic, gravity and georadar methods, drilling, measurement of physical and chemical properties of drill core and measurement of groundwater permeability were conducted. We found that the center of the subsurface tomb and the center of soil mound on ground are different 4.5 meter and 5 meter for the 5th tomb and 7th tomb, respectively. The fact has caused unequal stress on the tomb structure. In the 7th tomb (the Muryong royal tomb), 435 bricks were broken out of 6025 bricks in 1972, but 1072 bricks are broken in 1996. The break rate has been increased about 250% for just 24 years. The break rate increased about 290% in the 6th tomb. The situation in 1996 is the result for just 24 years while the situation in 1972 was the result for about 1450 years. Status of breaking of bircks represents that a severe problem is undergoing. The eastern wall of the Muryong royal tomb is moving toward inside the tomb with the rate of 2.95 mm/myr in rainy season and 1.52 mm/myr in dry season. The frontal wall shows biggest movement in the 7th tomb having a rate of 2.05 mm/myr toward the passage way. The 6th tomb shows biggest movement among the three tombs having the rate of 7.44mm/myr and 3.61mm/myr toward east for the high break rate of bricks in the 6th tomb. Georadar section of the shallow soil layer represents several faults in the top soil layer of the 5th tomb and 7th tomb. Raninwater flew through faults tnto the tomb and nearby ground and high water content in nearby ground resulted in low resistance and high humidity inside tombs. High humidity inside tomb made a good condition for algae living with high temperature and moderate light source. The 6th tomb is most severe situation and the 7th tomb is the second in terms of algae living. Artificial change of the tomb environment since the excavation, infiltration of rain water and groundwater into the tombsite and bad drainage system had resulted in dangerous status for the tomb structure. Main cause for many problems including breaking of bricks, movement of tomb walls and algae living is infiltration of rainwater and groundwater into the tomb site. Therefore, protection of the tomb site from high water content should be carried out at first. Waterproofing method includes a cover system over the tomvsith using geotextile, clay layer and geomembrane and a deep trench which is 2 meter down to the base of the 5th tomb at the north of the tomv site. Decrease and balancing of soil weight above the tomb are also needed for the sfety of tomb structures. For the algae living inside tombs, we recommend to spray K101 which developed in this study on the surface of wall and then, exposure to ultraviolet light sources for 24 hours. Air controlling system should be changed to a constant temperature and humidity system for the 6th tomb and the 7th tomb. It seems to much better to place the system at frontal room and to ciculate cold air inside tombs to solve dew problem. Above mentioned preservation methods are suggested to give least changes to tomb site and to solve the most fundmental problems. Repairing should be planned in order and some special cares are needed for the safety of tombs in reparing work. Finally, a monitoring system measuring tilting of tomb walls, water content, groundwater level, temperature and humidity is required to monitor and to evaluate the repairing work.

  • PDF

Climate-Smart Agriculture (CSA)-Based Assessment of a Rice Cultivation System in Gimje, Korea (한국 김제의 벼 경작 시스템의 기후스마트농업 (Climate-Smart Agriculture) 기반의 평가)

  • Talucder, Mohammad Samiul Ahsan;Kim, Joon;Shim, Kyo-Moon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.4
    • /
    • pp.235-250
    • /
    • 2021
  • The overarching question of this study is how a typical rice cultivation system in Gimje, Korea was keeping up with the triple-win challenge of climate-smart agriculture (CSA). To answer this question, we have employed (1) quantitative data from direct measurement of energy, water, carbon and information flows in and out of a rice cultivation system and (2) appropriate metrics to assess production, efficiency, GHG fluxes, and resilience. The study site was one of the Korean Network of Flux measurement (KoFlux) sites (i.e., GRK) located at Gimje, Korea, managed by National Academy of Agricultural Science, Rural Development Administration. Fluxes of energy, water, carbon dioxide (CO2) and methane (CH4) were directly measured using eddy-covariance technique during the growing seasons of 2011, 2012 and 2014. The production indicators include gross primary productivity (GPP), grain yield, light use efficiency (LUE), water use efficiency (WUE), and carbon uptake efficiency (CUE). The GHG mitigation was assessed with indicators such as fluxes of carbon dioxide (FCO2), methane (FCH4), and nitrous oxide (FN2O). Resilience was assessed in terms of self-organization (S), using information-theoretic approach. Overall, the results demonstrated that the rice cultivation system at GRK was climate-smart in 2011 in a relative sense but failed to maintain in the following years. Resilience was high and changed little for three year. However, the apparent competing goals or trade-offs between productivity and GHG mitigation were found within individual years as well as between the years, causing difficulties in achieving the triple-win scenario. The pursuit of CSA requires for stakeholders to prioritize their goals (i.e., governance) and to practice opportune interventions (i.e., management) based on the feedback from real-time assessment of the CSA indicators (i.e., monitoring) - i.e., a purpose-driven visioneering.

Gradient Noise Reduction in EEG Acquired During MRI Scan (MRI와 동시 측정한 뇌전도 신호에서 경사자계 유발잡음의 제거)

  • Lee H.R.;Lee H.N.;Han J.Y.;Park T.S.;Lee S.Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Purpose : Information about electrical activity inside the brain during fMRl scans is very useful in monitoring physiological function of the patient or locating the spatial position of the activated region in the brain. However, many additional noises appear in the EEG signal acquired during the MRI scan. Gradient induced noise is the biggest one among the noises. In this work, we propose a gradient noise reduction method using the independent component analysis (ICA) method. Materials and Methods : We used a 29-channel MR-compatible EEG measurement system and a 3.0 Tesla MRI system. We measured EEG signals on a subject lying inside the magnet during EPI scans. We selectively removed the gradient noise from the measured EEG signal using the ICA method. We compared the results with the ones obtained with conventional averaging method and PCA method. Results : All the noise reduction methods including the averaging and PCA methods were effective in removing the noise in some extent. However, the proposed ICA method was found to be superior to the other methods. Conclusion : Gradient noise in EEG signals acquired during fMRI scans can be effectively reduced by the ICA method. The noise-reduced EEG signal can be used in fMRI studies of epileptic patients or combinatory studies of fMRI and EEG.

  • PDF

Absorbed Dose Measurement by the MIRD System in the $^{131}I$ Treated Thyroid Cancer Patients (갑상선 암 환자에서 $^{131}I$ 치료시 MIRD Schema에 의한 흡수선량의 평가)

  • Lim, Sang-Moo;Woo, Kwang-Sun;Chung, Wee-Sup;Hong, Sang-Woon;Kim, Jang-Hee;Kim, Ki-Sup
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.54-60
    • /
    • 1995
  • Medical Internal Radiation Dose(MIRD) schema was developed for calculating the absorbed dose from the administered radiopharmaceuticals. With the biological distribution data and the physical properties of the radionuclide we can estimate the absorbed dose by the MIRD schema. For the thyroid cancer patients received $^{131}I$ therapy, the absorbed dose to the bone marrow is the limiting factor to the administered dose, and the duration of admission is deter-mined by the retained activity in the whole body. To monitor the whole body radioactivity, we used Eberline Smart 200 system using ionization chamber as a detector. With the time activity curve of the whole body, total body residence time was obtained. From the ICRP publication 53, the residence times of the source organs, such as kidney, urinary bladder content and stomach, were used to calculate the absorbed doses of the target organs, such as stomach, red marrow, bladder wall and remaineder total body. In 8 thyroid cancer patients with 175 mci of $^{131}I$ administered orally, the mean absorbed dose in the bladder wall was 375.1, in the stomach 285.1, red marrow 25.4 and total body 22.4 rad respectively. For the monitoring of the large administered activity, this method seemed to be quite useful.

  • PDF

Application of Laser-Induced Breakdown Spectroscopy (LIBS) for In-situ Detection of Heavy Metals in Soil (토양내 중금속 실시간 탐지를 위한 레이저 유도붕괴 분광법의 활용에 대한 소개)

  • Ko, Eun-Joung;Hamm, Se-Yeong;Kim, Kyoung-Woong
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.563-574
    • /
    • 2007
  • Laser induced breakdown spectroscopy (LIBS) is a recently developed analytical technique that is based upon the measurement of emission lines generated by atomic species close to the surface of the sample, thus allowing their chemical detection, identification and quantification. With powerful advantages of LIBS compared to the conventional analytical methodology, this technique can be applied in the detection of heavy metals in the field. LIBS allows the rapid analysis by avoiding laborious chemical steps. LES have already been applied for the determination of element concentration in a wide range of materials in the solid, liquid and gaseous phase with simplicity of the instrument and diversity of the analytical application. These feasibility of rapid multi elemental analysis are appealing proprieties for the in-situ analytical technique in geochemical investigation, exploration and environmental analysis. There remain still some limitations to be solved for LIBS to be applied in soil environment as an in-situ analytical technology. We would like to provide the basic principle related to the plasma formation and laser-induced breakdown of sample materials. In addition, the matrix effect, laser properties and the various factors affecting on the analytical signal of LIBS was dealt with to enhance understanding of LIBS through literature review. Ultimately, it was investigated the feasibility of LIBS application in soil environment monitoring by considering the basic idea to enhance the data quality of LIBS including the calibration method for the various effects on the analytical signal of LIBS.

Wavelength Interrogation Technique for Bragg Reflecting Strain Sensors Based on Arrayed Waveguide Grating (도파로 어레이 격자를 이용한 광섬유 브래그 스트레인 센서의 반사파장 신호 복원 기술)

  • Seo, Jun-Kyu;Kim, Kyung-Jo;Oh, Min-Cheol;Lee, Sang-Min;Kim, Young-Jae;Kim, Myung-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.68-72
    • /
    • 2008
  • Fiber-optic strain sensors based on Bragg reflection gratings produce the change of reflection spectrum when an external stress is applied on the sensor. To measure the Bragg reflection wavelength in high speed, an arrayed waveguide grating device is incorporated in this work. By monitoring the output power from each channel of the AWG, the peak wavelength corresponding to the applied strain could be obtained. To enhance the accuracy of the AWG wavelength interrogation system, a chirped fiber Bragg grating with a 3-dB bandwith of 5.4 nm is utilized. The high-speed response of the proposed system is demonstrated by measuring a fast varying strain produced by the damped oscillation of a cantilever. An oscillation frequency of 17.8 Hz and a damping time constant of 0.96 second are obtained in this measurement.

LC-MS/MS Screening Method for Radical Scavenging Active Compounds in Extracts of Ulmus pumila Cortex (유근피 추출물의 radical 소거 활성 성분에 대한 LC-MS/MS 스크리닝 분석법)

  • Im, Do-Youn;Lee, Kyoung-In
    • Journal of Life Science
    • /
    • v.30 no.11
    • /
    • pp.956-964
    • /
    • 2020
  • The radical scavenging activity measurement system linked with liquid chromatography (LC) is a useful tool for identifying the radical scavenging active compound in a sample composed of numerous compounds such as plant extracts. Using this system, DPPH and ABTS radical scavenging activity were measured on extracts of Ulmus pumila cortex, which is known as an herbal medicine with antioxidant activity. Mass spectrometry (MS) was performed on the identified radical scavenging active compounds to identify the four components estimated to be procyanidin B2, procyanidin B3, catechin-7-O-β-D-apiofuranoside, and catechin-5-O-β-D-apiofuranoside, respectively. In order to compare the relative contents between extract samples, multiple reaction monitoring (MRM) mode analysis conditions were set for the four compounds in order to examine the possibility of comparing the content of radical scavenging active compounds in Ulmus pumila cortex extract using LC-MS/MS. As a result of the relative content comparison, it was found that the higher the ethanol concentration of the extraction solvent, the higher the content of radical scavenging active compounds. As with the results of measuring the radical scavenging activity of each extract, it was confirmed that the content difference of three of the compounds (all except the compound estimated as procyanidin B3) was not significantly observed in the extracts with an ethanol concentration of 50% or more.