• Title/Summary/Keyword: monitoring device

Search Result 1,396, Processing Time 0.032 seconds

A Simulator for the Validation of Non-invasive Blood Pressure (NIBP) Monitoring Devices (자동혈압계 성능평가를 위한 인체혈압 시뮬레이터 개발)

  • Doh, Il;Lim, Hyun Kyoon;Ahn, Bongyoung;Chee, Youngjoon;Lee, Jongshill;OH, Jae Hoon
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.111-115
    • /
    • 2017
  • Blood pressure is one of the important vital signs for monitoring the medical condition of a patient. Automated NIBP(non-invasive blood pressure) monitoring devices calculate systolic and diastolic blood pressures from the oscillation in cuff pressure caused by a pulsation of an artery. To validate the NIBP devices, we developed a simulator to supply the oscillometric waveforms obtained from human subjects. The simulator provided pressure pulses to device-under-test and device readings were compared to the auscultatory references. Fully automated simulation system including OCR(optical character recognition) were developed and used for NIBP monitoring devices. The validation results using the simulator agreed well with previous clinical validation. More validation studies using the standardized oscillometric waveforms would be required for the replacement of clinical trials to validate a new automated NIBP monitoring device.

Design of The Patient Monitoring System based on Wearable Device for Multi-biosignal Measurement (다중 생체신호 측정 웨어러블 디바이스 기반 환자 모니터링 시스템 설계)

  • Lee, Minhye;Chung, Gisoo;Jeong, Dongmyong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.103-109
    • /
    • 2017
  • In order to apply the patient monitoring system to the hospital field, it is necessary to be able to measure and analysis data the major bio-signals that are basically covered by the existing patient monitoring system. We have implemented a wearable device and the patient monitoring system for measuring ECG and oxygen saturation. The implemented system transmits the measured bio-signal to the server on the nursing station via Bluetooth. It is represented by graph waveforms and numerical values that can be checked by the medical staff in the patient monitoring system. The validity of this system is verified by comparing the data collected through the designed system with the data obtained from the conventional equipment.

Android Remote Monitoring System of Ballast Water Treatment System (선박 평형수 처리 시스템의 안드로이드 원격 모니터링 시스템)

  • Choi, Hwi-Min;Seo, Ji-No;Lee, Kwang-Seob;Kim, Seon-Jong;Kim, Joo-Man
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.217-224
    • /
    • 2015
  • In this paper, I describe a system for remote monitoring of devices Android-based sensor data recorded during the operation of the ballast water treatment system. The proposed remote monitoring system is Designed and implemented when a problem occurs in the ballast water treatment system installed in the vessel, provide information if you are unable to determine the cause in the field or engineer dispatch request of external. System developed is composed of a server holding the sensor data information collected from the vessel and a mobile device that is not bound to time and place. The transmission of sensor data between mobile devices and server, and is implemented by TCP/IP to transmit information securely. System is composed of request to the server from the mobile device after the user inputs the input values, to transmit the sensor data. The device provides the information of the sensor with a high level of importance to the user. Through the remote monitoring sensor information of the ballast water treatment system, the system is made to predict the failure of the sensor.

Condition Monitoring Technique for Heating Cables by Detecting Discharge Signal (방전신호 검출에 의한 히팅 케이블의 상태감시기술)

  • Kim, Dong-Eon;Kim, Nam-Hoon;Lim, Seung-Hyun;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.136-141
    • /
    • 2021
  • Heating cables, widely used in office buildings, factories, streets and railways, deteriorate in electrical insulation during operation. The insulation deterioration of heating cables leads to electric discharges that can cause electrical fires. With this background, this paper dealt with a condition monitoring technique for heating cables by the analysis of discharge signals to prevent electrical fires. Insulation deterioration was simulated using an arc generator specified in UL1699 under AC operation, and the characteristic and propagation of discharge signals were analyzed on a 100 meter-long heating cable. Discharge signals produced by insulation deterioration were detected as a voltage pulse because they are as small as a few mV and they are attenuated through propagation path. The frequency spectrum of discharge signals mainly existed in the range from 70 kHz to 110 kHz, and the maximum attenuation of the signal was 84.8% at 100 meters away from the discharge point. Based on the experimental results, a monitoring device, which is composed of a high pass filter with the cut-off frequency of 70 kHz, a comparator, a wave shaper and a microprocessor, was designed and fabricated. Also, an algorithm was designed to discriminate the discharge signal in the presence of noise, compared with the pulse repetition period and the number of pulse counts per 100ms. In the experiment, the result showed that the prototype monitoring device could detect and discriminate the discharge signals produced at every discharge point on a heating cable.

Saltwater Intrusion Monitoring Evaluation through Automatic Vertical Line Method in a Costal Aquifer of the Eastern Part of Jeju Island (수직 라인 관측시스템을 이용한 제주 동부 해안대수층에서 해수침투 모니터링 평가)

  • Jang, Hojune;Ha, Kyoochul;Hwang, Inuk;Kim, Gee-Pyo;Park, Won-Bae
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.3
    • /
    • pp.1-13
    • /
    • 2021
  • Groundwater monitoring is commonly practiced with real-time sensors placed in several depth spots in aquifer. However, this method only provides monitoring data at the point where the sensors are installed. In this study, we developed a vertical line monitoring system (VLMS) that can provide continuous data of groundwater parameters along the vertical depth. The device was installed in a well located on the coast of the eastern part of Jeju island to monitor electrical conductivity, temperature, salinity, pH, dissolved oxygen, and oxidation-reduction potential over approximately 3 months from September 11 to December 3, 2020. The results indicated that the groundwater levels fluctuated with the tidal change of seawater level, and the upper and lower boundaries of the freshwater and saltwater zone in the groundwater were located at below 16 m and 36 m of mean sea level, respectively. There was a large variation in EC values during the high tide and temperature change was the greatest during flow tide. Although further investigation is needed for improvement of the device to obtain more accurate and reliable data, the device has a potential utility to provide fundamental data to understand the seawater intrusion and transport mechanisms in coastal aquifers.

Implementation of ICT-based Underwater Communication Monitoring Device for Underwater Lifting (수중구조를 위한 ICT 기반 수중통신 모니터링 장치 구현)

  • Yoon, Jong-Hwa;Kang, Sang-iL;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.396-400
    • /
    • 2022
  • In this study, an ICT-based underwater communication monitoring device for underwater structures is implemented based on lifting fixture that transport human bodies found on the seabed to sea level. The lifting fixture is packaged with a retback, sideback, and cartridge that injects air. Monitoring systems are developed in a mobile manner in a portable structure. The underwater ultrasonic sensor signal is supplied using a USB port, and the O/S consists of Linux. For the underwater communication dong test, a measurement test was conducted in real time from 6m to 40m in depth on the east coast. The ultrasonic sound sensor is converted to 2,400 bps to verify the transmission error according to the duality. The communication speed of sensor to monitoring is 115,200 bps, and the speed of communication from controller to receiver is 2,400 bps. In the commercialization stage of the lifting device, it is easy to develop a low-end type and the compatibility is wide.

Transmission Characteristics in LonWorks/IP-based Virtual Device Network (II)

  • Park, Gi-Heung;Song, Ki-Won;Kim, Jong-Hwi;Park, Gi-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.121.6-121
    • /
    • 2002
  • Web-based virtual machine/manufacturing system (VMS) utilizes Virtual Device Network (VDN.) VDN inevitably involves the implementation of Distributed Monitoring and Control Networks (DMCN). In general, one needs to integrate device (control) network and IP network to realize DMCN over IP network or internet, which can be viewed as a VDN. In this study, LonWorks networking technology is used for device network and the transmission characteristics of LonWorks/IP-based VDN is investigated. A method to minimize the transmission delay in the LonWorks/IP networks is also suggested.

  • PDF

A Plan of Existing System Interface within Station (역사내 기존 시스템 인터페이스 방안)

  • Lee, Won-Jae;An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1550-1555
    • /
    • 2011
  • This paper presents the system interface standard that are associated with additional devices like sensor nodes as well as fire monitoring panel, panic button and emergency call in city railroad environment. Existing fire monitoring panel, panic button and emergency call system is responsible for fire detection and alarm, emergency alarm and communication with the manager. Recently, researches that are associated with NVR-based intelligent integrated surveillance systems and existing alarm system are activated but most of the system is dedicated to it existing. In order to expand devices that is supported other monitoring function, separate device configuration or modification of integrated surveillance system are inevitable. In this study, interface standard between standard controller, integrated command center and each device that facilitate additional expansion of integrated surveillance system and avoid the extra cost is presented.

  • PDF

Implementation of Web Based Monitoring Systems for Multi-Axis Force Control Systems (다축 힘제어 시스템을 위한 웹기반 감시시스템 구현)

  • Nam, Seung-Uk;Lee, Hyun-Chul;Nam, Hyun-Do;Kang, Chul-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.3072-3074
    • /
    • 2005
  • In this paper, web based monitoring systems are implemented for multi-axis force control systems of an intelligence robot. A web based monitoring system is implemented by porting Linux at embedded systems which include a Xscale processor. A device driver is developed to receive data from multi-axis force sensors in Linux operation systems. To control this device driver, a socket program for the Labview is also developed.

  • PDF

Software approach towards understanding meteorological data for environmental monitoring and assessment of peninsular Malaysia

  • Quadri, Sayed Abulhasan;Sidek, Othman;Jafar, Hadi;binti Amran, Nur Amira;bt Zabah, Ummi Nurulhaiza;bin Abdullah, Azizul
    • Advances in environmental research
    • /
    • v.3 no.1
    • /
    • pp.87-106
    • /
    • 2014
  • The concern for the global environment ensues researchers from various disciplines to work in collaboration to tackle with the issues of sustainability and environmental conservation for well-being of the people. In this study, we have selected and focused on few basic environment-effecting factors such as temperature, humidity, carbon dioxide and oxygen concentration level and referred them as meteorological data. In this paper, we present the development of our own customized hardware setup, environmental monitoring device (EMD) to obtain the data. Utilizing the relationship among these basic parameters, represented in the form of formulas and equations, we tried to encode them using Matlab programming. Data visualization is achieved by plotting the graphs of basic parameters obtained from EMD as well for the derivatives using Matlab programs.