• Title/Summary/Keyword: module configuration

Search Result 344, Processing Time 0.022 seconds

A Modular Disturbance Observer-based Cascade Controller for Robust Speed Regulation of PMSM

  • Kim, In Hyuk;Son, Young Ik
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1663-1674
    • /
    • 2017
  • This paper deals with the robust speed regulation of a surface-mounted permanent magnet synchronous motor (SPMSM) that is subject to parametric uncertainties and external disturbances. The proposed approach retains a conventional cascade control configuration composed of an outer-loop speed control module and inner-loop current control modules. Baseline proportional-integral (PI) controllers are designed for nominal modular systems without accounting for the uncertainties to set a desired control performance of the closed-loop system. After studied in both frequency and time domains, a reduced-order proportional-integral observer (PIO), as a modular disturbance observer, is incorporated with each control module to maintain the ideal performance of the modules. Theoretical analysis confirms the desired performance recovery of the augmented system with modular PIOs to the nominal system. Comparative computer simulations and experimental results validate the proposed cascade control method for SPMSM speed regulation.

Mobile Subscriber Roaming n Different Mobile Networks Using UIM and PASM

  • Park, Jeong-Hyun;Yang, Jeong-Mo
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2003.11a
    • /
    • pp.445-448
    • /
    • 2003
  • During a time when cellular systems are being deployed in massive scale worldwide, international roaming is becoming increasingly important. This paper presents UIM (User Identification Module) for mobility support, authentication, and service portability between different mobile systems. We also introduce network model based on PASM(Portable Authentication and Mobility Service Machine) which will support signaling protocol and user information conversions with database for roaming between different mobile networks. Stored data types and elements in UIM, logical data structure and configuration, and registration procedures are described here in the case of DCN (Digital CDMA (Code Division Multiple Access) Network System) and GSM (Global System for Mobile Communications).

  • PDF

On a Characteristics of Mast Arm Using DC Motor (DC 모터를 이용한 마스트 암의 특성에 관하여)

  • Moon, Jin-Soo;Kim, Cheul-U
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.295-299
    • /
    • 2007
  • Biped robot requires that an energy source and a control part should be installed on the body to realize active system. So, we choose the DC motor having high torque in compact size in this study. In the DC motor serve system, we choose power amplifier with analog configuration, developed the module combined the controller and the driver. We applied this module to robot actuator and studied the response characteristics in an action and a return. Main controller with serve system, loading PIC micro controller, can be load on the robot with light weight.

  • PDF

ANALYSIS ON THE AVAILABILITY OF COMS GS

  • Park, Durk-Jong;Lim, Hyun-Su;Ahn, Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.212-215
    • /
    • 2006
  • This paper describes several reliability models to estimate COMS ground segment availability and shows assessed availability according to GS function. Due to a back-up concept among three ground center, SOC will have all H/W and S/W module to be installed in MSC and KOSC site. Therefore, all configurations and availability parameters for H/W and S/W modules in MSC and KOSC are assumed as equal with those in SOC, if related modules have same function. Prior to access availability over COMS GS function, Availability related to fundamental configuration such as series, parallel, partial operation, and module combined H/W and S/W is described. Consequently, all functions are expected to operate with more than 99% of availability.

  • PDF

A Stacked Pad Area Array Package for 224MHz RF Transceiver Modules (224MHz RF 송수신 회로의 적층형 PAA 패키지)

  • Nam, Sang-Woo;Hong, Seok-Yong;Jee, Yong
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.187-190
    • /
    • 2000
  • We presents the construction of radio frequency pad area array package modules which operate at radio frequency of 224MHz, and proposes the structure of RF module packages to improve its electrical characteristics. The module of RF PAA package was constructed in the configuration of three dimensional stacked package and reduced size. RF PAA packages showed the optimized and improved gain of 2dB by partitioning the RF transceiver with 3 dimensional stacked PAA packages.

  • PDF

Development of monitoring system of static frequency converter in pumped storage power plant (양수발전소 SFC 감시시스템 개발)

  • Lee, Joo-Hyun;Lim, Ick-Hun;Ryu, Ho-Sun;Sin, Man-Soo;Kim, Bong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.213-215
    • /
    • 2006
  • A static frequency converter(SFC) in a pumped storage power plant is important equipment for converting electric motor kinetic energy into electric Bower. A SFC monitoring system consists of high voltage thyristor firing equipment, fault detection module, data gathering module, real time data processing equipment and man machine Interface system. This paper describes SFC system overview, developed SFC monitoring system configuration including system characteristics. and successful application result to San-Cheong pumped storage power plant.

  • PDF

Equifield line simulation and ion migration prediction for concrete under 2-D electric field

  • Liu, Chih-Chien;Kuo, Wen-Ten;Huang, Chun-Yao
    • Computers and Concrete
    • /
    • v.12 no.4
    • /
    • pp.431-442
    • /
    • 2013
  • This study attempted to find a proper method applicable to simulating practical equifield lines of two-dimensional Accelerate Lithium Migration Technique (ALMT), and evaluate the feasibility of using the theoretical ion migration model of one-dimensional ALMT to predict the ion migration behavior of two-dimensional ALMT. The result showed that the electrolyte or carbon plate can be used as matrix to draw equifield line graph similar to that by using mortar as matrix. Using electrolyte electrode module for simulation has advantages of simple production, easy measurement, rapidness, and economy. The electrolyte module can be used to simulate the equifield line distribution diagram in practical two-dimensional electrode configuration firstly. Then, several equifield line zones were marked, and several subzones under one-dimensional ALMT were separated from various equifield line zones. The theoretical free content distribution of alkali in concrete under two-dimensional electric field effect could be obtained from duration analysis.

A zigbee based schoolzone system configuration (지그비 기반 스쿨존 시스템 구성)

  • Park, Sangjoon;Lee, Jongchan;Shin, Sungyun;Park, Gihong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.566-567
    • /
    • 2013
  • In simulation model, when it's occurred model succession, the parent model is connected to child model. When the schoolzone system is constructed, it needs the module on networks. Hence, it is considerable about the zigbee based communication module so that this paper proposes the zigbee based schoolzone setup scheme.

  • PDF

Development of firing equipment and monitoring system for electric power conversion system for high voltage and large current (고압 대전류용 전력변환 점호장치 및 감시시스템 개발)

  • Lee Joo-Hyun;Lim Ick-Hun;Ryu Ho-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.481-484
    • /
    • 2006
  • A electric power conversion system in a pumped storage power plant is important equipment for converting electric motor kinetic energy into electric power. A electric power conversion monitoring system consists of high voltage thyristor firing equipment, fault detection module, data gathering module, real time data processing equipment and man machine interface system. This paper describes electric power conversion system overview, the developed SFC monitoring system configuration including system characteristics, and successful application result to San-Cheong pumped storage power plant.

  • PDF

A Basic Study for Treatment of Sewage and Leachate Using Submerged Nonwoven Bioreactor(SNBR) (부직포활성슬러지법에 의한 하수와 침출수처리에 관한 기초연구)

  • 정유진;고현웅;김경순;윤태경;성낙창
    • Journal of Environmental Science International
    • /
    • v.12 no.10
    • /
    • pp.1095-1100
    • /
    • 2003
  • In this study, it was performed using submerged nonwoven bioreactor(SNBR) for removal of organic matter, nitrogen and phosphate under different aeration intervals(intermittent aeration). We applied the SNBR at the cheap nonwoven fiber module instead of the expensive membrane. The SUBR was mainly made up of an activated sludge reactor and a transverse flow nonwoven module, with an innovative configuration being in application between them. In case of sewage, the aeration conditions experimented consist of continuous aeration and 60min/60min, 120min/60min, 120min/120min of aeration/nonaeration time intervals, respectively. In case of landfill leachate, the intermittent aeration condition was 120min/120min at aeration/nonaeration. Consequently, a high COD removal rate (about 94%) was achieved in sewage and leachate. Although nutrient removal rate was relatively high without any additional chemicals.