• 제목/요약/키워드: modulation transfer function(MTF)

검색결과 207건 처리시간 0.026초

교란파가 유리창 진동음의 음성명료도에 미치는 영향 (The Effect of the Disturbing Wave on the Speech Intelligibility of the Eavesdropping Sound of a Window Glass)

  • 김석현;김희동;허욱
    • 한국소음진동공학회논문집
    • /
    • 제17권9호
    • /
    • pp.888-894
    • /
    • 2007
  • The speech sound is detected by the vibration measurement of the window glass. In this study, we investigate the effect of the disturbing waves by background noise and window shaker excitation on the speech intelligibility of the detected sound. Based upon Modulation Transfer Function(MTF), speech intelligibility of the sound is objectively estimated by Speech Transmission Index(STI) As the level of the disturbing wave varies, variation of the speech intelligibility is examined. Experimental result reveals how STI is influenced by the level and frequency characteristics of the disturbing wave. By using a customized window shaker for disturbing sound, we evaluate the efficiency and the frequency characteristics of the anti-eavesdropping system. The purpose of the study is to provide useful information to prevent the eavesdropping through the window glass.

Objective Assessment of Visual Quality and Ocular Scattering Based on Double-pass Retinal Images in Refractive-surgery Patients and Emmetropes

  • Kim, Jeong-mee
    • Current Optics and Photonics
    • /
    • 제3권6호
    • /
    • pp.597-604
    • /
    • 2019
  • This study was performed to evaluate objective visual quality and ocular scattering in myopic refractive-surgery patients, compared to emmetropes. Optical vision-quality parameters (modulation transfer function (MTF) cutoff and Strehl ratio) and objective scattering index (OSI) were measured using an optical quality analysis system (OQAS II) based on the double-pass technique. In all subjects, the higher the MTF cutoff and Strehl ratio, the lower the OSI and ocular higher-order aberrations (HOAs). The MTF cutoff and Strehl ratio for the laser-assisted subepithelial keratectomy (LASEK) group were lower than those for the emmetropia group, while the OSI, ocular HOAs, and spherical aberration (SA) for the LASEK group were higher than those for emmetropia group. Ocular scattering would be one of the important factors in regard to visual quality. Therefore, the quality of the retinal image in the LASEK patients has been shown to reduce the quality of vision more than in the emmetropes.

CR과 DR 영상화질의 정량적 비교분석 (Quantitative Analysis and Comparison of DR and CR image quality)

  • 박혜숙;서장연;정진화;이창래;조효민;김희중
    • 한국방사선학회논문지
    • /
    • 제1권1호
    • /
    • pp.31-37
    • /
    • 2007
  • 본 연구의 목적은 CR(Computed Radiography)과 DR(Digital Radiography)장비의 각 Detector를 통해 획득된 영상의 화질을 비교 분석하기 위한 것이다. CR(AGFA MD 4.0 General plate, JAPAN)과 DR(HOLOGIC nDirect Ray, USA)에 대한 영상평가의 주요인자인 MTF(Modulation transfer function), NPS(Noise power spectrum), Photon fluence, DQE(Detective quantum efficiency)를 정량적인 값으로 도출하여 비교한 결과 CR이 DR보다 우수하게 나타났다. 본 연구의 결과는 CR과 DR장비의 Image quality를 정량적으로 평가할 수 있을 뿐만 아니라 이 장비들을 유지, 보수하는데도 도움이 될 것으로 사료된다.

  • PDF

반도체 와이어 본딩 검사용 다중배치 현미경 광학계에 대한 공차분석 (Tolerance analysis of Multi-Configurative Microscopic System for Inspecting the Wire-Bonding Status of Semiconductor Chips)

  • 류재명;이해진;강건모;정진호;백승선;조재흥
    • 한국광학회지
    • /
    • 제17권2호
    • /
    • pp.149-158
    • /
    • 2006
  • 가우스 괄호법을 이용한 굴절능 배치 방법과 등가렌즈 설계법으로 기존에 설계한 반도체와이어 본딩 검사용 다중배치 현미경 광학계에 대한 공차 분석을 하였다. 축상 대칭 공차인 곡률과 두께에 대한 공차는 회절 한계에 의한 초점심도 내에서 후방초점거리(BFL)가 변하도록 결정하였고, 축 비대칭 공차인 decenter와 tilt에 대한 공차는 0.7 field에서 공간주파수 50 lp/mm에서의 MTF(Modulation Transfer Function) 변화가 5% 이내가 되도록 시행착오 방법으로 정하였다. 이 결과 공차분포확률에 관계없이 MTF의 감소율이 5% 미만 되는 곳에 가장 많은 확률로 공차가 분포하므로 위와 같은 방법으로 공차를 부여하면 원하는 본 광학계의 결상 성능을 만족시킬 수 있음을 확인하였다.

자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원;한지현;이시내;김민지;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging)

  • 민정환;정회원;강혜경
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권1호
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

시각 하중 이산여현변환 영상부호화 (Image Coding of Visually Weighted t Discrete Cosine Transform)

  • 이문호;박주용
    • 기술사
    • /
    • 제22권2호
    • /
    • pp.19-25
    • /
    • 1989
  • Utilizing a cosine transform in image compression has several recognized performance benefits, resulting in the ability to attain large compression ratio with small quality loss. Also, various models incorporating Human Visual System (HVS) to Discrete Cosine Trans-form (DCT) scheme are considered. Using the exact frequency components of DCT basis function, the optimum modulation transfer function (MTF) is obtained analytically. The errors at a block boundary which is important factor in transform coder are criteria for error measurement. The HVS weight coding results in perceptually higher quality images compared with the unweighted scheme.

  • PDF

평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구 (Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance)

  • 박지군;최장용;강상식;이동길;석대우;남상희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권4호
    • /
    • pp.39-46
    • /
    • 2003
  • 의료영상 분야에서의 디지털화가 시도되면서부터 평판형 디지털 영상검출기가 일반촬영 및 투시영상을 비롯한 다양한 영상 획득 장치에의 적용을 위해 꾸준히 연구, 개발되어져 왔다. 본 연구는 비정질 셀레늄을 이용한 디지털 방사선 검출기를 통해 획득된 영상의 평가를 통해 순수 국내 기술로 개발중인 디지털 방사선 검출기의 임상 사용여부를 확인하고, 영상평가의 주요인자인 modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) 이용하여 정량적인 값을 도출함으로써 의료영상평가에 필요한 측정 방법 및 그 기초 자료의 제공을 그 목적으로 한다. 비정질 셀레늄을 이용한 디지털 방사선 검출기는 pixel pitch가 $139\;{\mu}m$이며, 전체 active area은 $14{\times}8.5\;inch^2$, 전체 pixel의 수는 3.9백만개이다. 디지털 X-선 검출기에서 광도전체로서 비정질 셀레늄은 TFT 평판 패널 위에 진공 증착된다. 비정질 셀레늄의 두께는 $500\;{\mu}m$이다. 디지털 방사선 검출기의 성능을 평가하기 위해 민감도, 선형성, MTF, NPS, 그리고 DQE가 측정되었다. 선형성 평가에서는 뛰어난 선형성[($r^2$)=0.9693]을 보였다. 측정된 민감도는 인가전압 $10\;V/{\mu}m$에서 $4.16{\times}10^6\;ehp/pixel{\cdot}mR$이며, MTF는 2.5\;lp/mm에서 52%이다. 그리고 DQE는 1.5\;lp/mm에서 75%이다. 본 연구를 통해 영상평가 측정 기술의 기본적 토대를 마련하고, 측정된 값은 국내 기술로 개발중인 비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기의 임상적 사용가치가 충분함을 뒷받침할 수 있는 기초 자료로서 제공될 수 있을 것으로 판단된다.

  • PDF

텅스텐 엣지 블록을 이용하여 Megavoltage (MV) 영상의 질 평가 (Evaluation of Image Quality by Using a Tungsten Edge Block in a Megavoltage (MV) X-ray Imaging)

  • 민정환;손진현;김기원;이정우;손순룡;백금문;김정민;김연래;정재용;김상영;이도완;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제23권3호
    • /
    • pp.154-161
    • /
    • 2012
  • 최근 백만 볼트 영상(megavoltage imaging, MVI)에서 급격히 발전해 온 디지털 방사선영상(digital radiography, DR)은 치료용 방사선영상 기술이 발전함에 따라 매우 정확하면서 간단하게 측정할 수 있는 일반적인 정도관리(quality assurance, QA) 방법을 요구하게 되었다. 본 연구의 목적은 일반적인 QA 방법과 computed radiography (CR) 장비를 사용하여 MVI의 변조전달함수(modulation transfer function, MTF), 잡음전력스펙트럼(noise power spectrum, NPS), 양자검출효율(detective quantum efficiency, DQE)를 평가하고자 하였다. 텅스텐으로 구성된 $19{\times}10{\times}1cm^3$ 두께의 엣지(edge) 블록을 사용하였으며, 6 MV energy를 사용하였다. 또한 검출기는 CR-IP (image plate), CR-IP-lead, the CR-IP-back (lanex TM fast back screen), CR-IP-front (lanex TM fast front screen)를 사용하였으며, pre-sampling MTF를 계산하였다. CR-IP의 MTF는 0.70 lp/mm를 나타내었고, CR-IP front의 MTF는 1.10 lp/mm로서 가장 높은 값의 고해상도 공간분해능을 보였다. 가장 우수한 검출기의 NPS는 CR-IP front screen에서 확인되었다. 공간주파수가 증가함에 따라 1.0 cycles/mm의 가까운 DQE를 획득하였다. 본 연구결과로서 자체 제작한 엣지 블록 방법은 MVI의 MTF, NPS, DQE를 평가하는 일반적인 QA 방법으로 사용될 수 있음을 확인하여 주었다.

홀로그램 광 저대역 필터의 MTF 특성 개선을 위한 다중 위상 설계 (Design of Multi-phase Holographic Optical Low-pass Filter for the Improvement of the MTF Characteristics)

  • 오용호;고춘수
    • 한국광학회지
    • /
    • 제16권4호
    • /
    • pp.334-339
    • /
    • 2005
  • 디지털 영상 장치에서 홀로그램 광 저대역 필터를 사용할 때 해상도 저하 문제를 개선하기 위해 다중 위상 홀로그램을 설계하였다. 자체 제작한 몬테-카를로 방식의 홀로그램 설계 프로그램을 이용하여 회절광 세기 분포가 원형에 가깝도록 홀로그램을 설계하였고 그 회절 효율과 MTF를 구하였다. 설계 결과 홀로그램의 한 주기를 구성하는 셀의 개수는 MTF 특성에 별로 영향을 미치지 못한 반면에 홀로그램의 위상 수는 큰 영향을 미침을 확인하였다. 4 위상 홀로그램은 2 위상 홀로그램과 회절 효율이 같고 MTF 또한 2 위상에서와 같이 저주파수 영역에서 직선 형태가 되어 필터로서의 특성이 변하지 않았다. 그러나 8 위상 홀로그램의 경우에는 회절 효율도 2 위상에 비해 크게 개선되었고 저주파수 영역에서의 MTF 값도 증가하여 필터의 성능이 크게 향상되었다. 16 위상인 경우에는 회절 효율도 더 증가하고 MTF 그래프도 더 위로 볼록한 모양이 되었으나 그 증가 폭은 크게 감소하였다. 설계된 8 위상 홀로그램을 제작하고 MTF를 측정하여 2 위상보다 MTF 특성이 향상됨을 실험적으로 확인하였다.