Acknowledgement
This study was supported by from the Shingu University Industry-Academic Cooperation Foundation Grant 2022.
References
- Min JW, Jeong HW, Kim KW, et al. Study on the Resolution Characteristics by Using Magnetic Resonance Imaging 3.0T. Journal of Radiological Science and Technology. 2020;43(4):251-7. https://doi.org/10.17946/JRST.2020.43.4.251
- Min JW, Jeong HW, Kim SC. Evaluation of Noise Power Spectrum Characteristics by Using Magnetic Resonance Imaging 3.0T. Journal of Radiological Science and Technology. 2021;44(1):279-88.
- Lee JW, Ahn KJ, Lee SK, Na DG, Oh CH, Chang YM, et al. Usefulness of ACR MRI phantom for quality assurance of MRI instruments. Journal Korean Society Radiology. 2006;54(1):47-55. https://doi.org/10.3348/jkrs.2006.54.1.47
- Miyati T, Fujita H, Kasuga T, et al. Measurements of MTF and SNR(f) using a subtraction method im MRI. Physics in Medicine and Biology. 2002;47:961-72. https://doi.org/10.1088/0031-9155/47/6/308
- Steckner MC, Drost DJ, Prato FS. Computing the modulation transfer function of a magnetic resonance imager. Med Phys. 1994;21:483-9. https://doi.org/10.1118/1.597310
- Hahm HK. The study on the subject development of MRI image quality evaluation Department of Radiology. Graduate school of Public Health Eulji University; 2008.
- Min JW, Jeong HW, Kim KW, et al. Comparison of Noise Power Spectrum in Measurements by Using International Electrotechnical Commission Standard Devices in Indirect Digital Radiography. Journal of Radiological Science and Technology. 2018;41(5):57-62.
- Min JW, Jeong HW. Comparison of Modulation Transfer Function in Measurements by Using Edge Device angle in Indirect Digital Radiography. Journal of Radiological Science and Technology. 2019;42(4):259-63. https://doi.org/10.17946/JRST.2019.42.4.259
- Jeong HW, Min JW, Kim JM, et al. Investigation of Physical Imaging Properties in Various Digital Radiography System. Journal of Radiological Science and Technology. 2017;40(3):363-70. https://doi.org/10.17946/JRST.2017.40.3.02
- Jeong HW, Min JW, Kim JM, et al. Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System. Journal of Radiological Science and Technology. 2012;35(2):109-17.
- Kim KW, Jeong HW, Min JW, et al. Evaluation of the Performance Characteristic for Mammography by Using Edge device. Journal of Radiological Science and Technology. 2016;39(3):415-20. https://doi.org/10.17946/JRST.2016.39.3.16
- Kim KW, Jeong HW, Min JW, et al. Measurement of Image Quality According to the Time of Computed Radiography System. Journal of Radiological Science and Technology. 2015;38(4):365-74. https://doi.org/10.17946/JRST.2015.38.4.05
- Kim KW, Jeong HW, Min JW, et al. Evaluation of the Modulation Transfer Function for Computed Tomography by Using American Association Physics Medicine Phantom. Journal of Radiological Science and Technology. 2016;39(2):193-8. https://doi.org/10.17946/JRST.2016.39.2.09
- Mohapatra SM, Turley JD, Prince JR, et al. Transfer function measurement and analysis for magnetic resonance imager. Med Phys. 1991;18(6):1141-4. https://doi.org/10.1118/1.596622
- Fujita H, Tasai DY, Itoh T, et al. A simple method for determining the modulation transfer function in digital radiography. IEEE Trans Med Imaging. 1992;11(1):34-9. https://doi.org/10.1109/42.126908
- Samei E, Flynn MJ, Reimann DA, et al. A method for measuring the presampled MTF of digital radiographic systems using an edge test device. Medical Physics. 1998;25:102-13. https://doi.org/10.1118/1.598165
- Greer PB, Van Doorn T. Evaluation of an algorithm for the assessment of the MTF using an edge method. Medical Physics. 2000;27:2048-59. https://doi.org/10.1118/1.1288682
- IEC(International Electrotechnical Commission) 62220-1. Medical electrical equipment Characteristics of digital X-ray imaging devices Part 1: Determination of the detective quantum efficiency. Geneva; 2003.
- Och JG, Clarke GD, Sobol WT, Rosen CW, Mun SK. Acceptance testing of magnetic resonance imaging systems: Report of AAPM Nuclear Magnetic Resonance Task Group No. 6. Med Phys. 1992;19:217-29. https://doi.org/10.1118/1.596903
- American College of Radiology. Phantom test guidance for the ACR MRI accreditation program. Reston: American College of Radiology; 2000.
- American College of Radiology. MRI quality control manual. American College of Radiology, Reston; 2004.
- Choi YJ, Kweon DC. Evaluation of TOF MR Anagiography and Imaging for the Half Scan Factor of Cerebral Artery. Journal of the Korean Magnetics Society. 2016;26(3):92-8. https://doi.org/10.4283/JKMS.2016.26.3.092