• 제목/요약/키워드: mode volume

검색결과 595건 처리시간 0.027초

Mixed mode fracture assessment of U-notched graphite Brazilian disk specimens by means of the local energy

  • Torabi, A.R.;Berto, F.
    • Structural Engineering and Mechanics
    • /
    • 제50권6호
    • /
    • pp.723-740
    • /
    • 2014
  • A fracture criterion based on the strain energy density (SED) over a control volume, which embraces the notch edge, is employed in the present paper to assess the fracture loads of some U-notched Brazilian disk (UNBD) specimens. The specimens are made of commercial graphite and have been tested under pure mode I, pure mode II and mixed mode I/II loading. The results show that the SED criterion allows to successfully assess the fracture loads of graphite specimens for different notch tip radii and various mode mixity conditions with discrepancies that fall inside the scatter band of ${\pm}20%$.

아이리스 최적화 기법을 이용한 In-line형 6극 삼중모드 협대역 채널여파기의 설계 (Design of in-line Six-pole triple-mode narrow-band channel filter using iris optimization method)

  • 정근욱;이재현;염인복;박광량;김재명
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.62-71
    • /
    • 1996
  • In this paper, we design tripel-mode channel filter using iris optimization technique and investigate its response. The cavity diameter is determined to resonate three orthogonal modes coincidently and inter-cavity iris is optimized in which one slot control one TE-TE mode and other TM-TM mode couplings simultaneously. Since the electric/magnectic field is variable due to slot position, the center position of the slot which handle coupling coefficients of two modes should be designe dwith optimizatin technique presented here. The implemented triple-mode filter in this paper saves its mass and volume upto 33% relating to the dual-mode filter, caused by the reduced number of cavities.

  • PDF

Effects of small tidal volume and positive end-expiratory pressure on oxygenation in pressure-controlled ventilation-volume guaranteed mode during one-lung ventilation

  • Byun, Sung Hye;Lee, So Young;Jung, Jin Yong
    • Journal of Yeungnam Medical Science
    • /
    • 제35권2호
    • /
    • pp.165-170
    • /
    • 2018
  • Background: The purpose of this study was to investigate whether tidal volume (TV) of 8 mL/kg without positive end-expiratory pressure (PEEP) and TV of 6 mL/kg with or without PEEP in pressure-controlled ventilation-volume guaranteed (PCV-VG) mode can maintain arterial oxygenation and decrease inspiratory airway pressure effectively during one-lung ventilation (OLV). Methods: The study enrolled 27 patients undergoing thoracic surgery. All patients were ventilated with PCV-VG mode. During OLV, patients were initially ventilated with TV 8 mL/kg (group TV8) without PEEP. Ventilation was subsequently changed to TV 6 mL/kg with PEEP ($5cmH_2O$; group TV6+PEEP) or without (group TV6) in random sequence. Peak inspiratory pressure ($P_{peak}$), mean airway pressure ($P_{mean}$), and arterial blood gas analysis were measured 30 min after changing ventilator settings. Ventilation was then changed once more to add or eliminate PEEP ($5cmH_2O$), while maintaining TV 6 mL/kg. Thirty min after changing ventilator settings, the same parameters were measured once more. Results: The $P_{peak}$ was significantly lower in group TV6 ($19.3{\pm}3.3cmH_2O$) than in group TV8 ($21.8{\pm}3.1cmH_2O$) and group TV6+PEEP ($20.1{\pm}3.4cmH_2O$). $PaO_2$ was significantly higher in group TV8 ($242.5{\pm}111.4mmHg$) than in group TV6 ($202.1{\pm}101.3mmHg$) (p=0.044). There was no significant difference in $PaO_2$ between group TV8 and group TV6+PEEP ($226.8{\pm}121.1mmHg$). However, three patients in group TV6 were dropped from the study because $PaO_2$ was lower than 80 mmHg after ventilation. Conclusion: It is postulated that TV 8 mL/kg without PEEP or TV 6 mL/kg with $5cmH_2O$ PEEP in PCV-VG mode during OLV can safely maintain adequate oxygenation.

Inter-Pillar 진동 모드를 고려한 1-3형 압전복합체의 구조 최적화 (Optimization of 1-3 Type Piezocomposite Structures Considering Inter-Pillar Vibration Modes)

  • 표성훈;김진욱;노용래
    • 한국전기전자재료학회논문지
    • /
    • 제26권6호
    • /
    • pp.434-440
    • /
    • 2013
  • With polymer properties and ceramic volume fraction as design variables, the optimal structure of 1-3 piezocomposites has been determined to maximize the thickness mode electromechanical coupling factor. When the piezocomposite vibrates in a thickness mode, inter-pillar resonant modes are likely to occur between lattice-structured piezoceramic pillars and polymer matrix, which significantly deteriorates the performance of the piezocomposite. In this work, a new method to design the structure of the 1-3 type piezocomposite is proposed to maximize the thickness mode electromechanical coupling factor while preventing the occurrence of the inter-pillar modes. Genetic algorithm was used for the optimal design, and the finite element analysis method was used for the analysis of the inter-pillar mode.

이중용량 왕복동 압축기 신뢰성 확보에 대한 연구 (A Study on the Reliability of a Dual Capacity Reciprocating Compressor)

  • 김종봉
    • 한국정밀공학회지
    • /
    • 제26권7호
    • /
    • pp.81-90
    • /
    • 2009
  • Due to environmental issues, the development of low energy consumption products has become one of the main topics in the home appliance industry. The energy consumption of a refrigerator depends on the efficiency of its compressor as well as on the refrigerator cycle design, such as the capacity modulation. In this study, a dual capacity, i.e., two-step capacity modulation (TCM), reciprocating compressor is developed. In a TCM compressor, capacity modulation is achieved by changing the dead volume in the cylinder. Instead of a concentric sleeve, an eccentric sleeve, a key, and a spring are used to change the dead volume for the clockwise and counterclockwise rotation of a motor. When the compressor changes its operating mode from full capacity to partial capacity or in opposite direction, the key may collide with the eccentric sleeve. The structural reliability and mode change reliability were confirmed by analysis and experiment.

Quantitative Doppler echocardiography during Dobutamine stress test in canine mitral regurgitant model

  • Choi, Hojung;Won, Sungjun;Lee, Kichang;Choi, Mincheol;Yoon, Junghee
    • 대한수의학회지
    • /
    • 제44권2호
    • /
    • pp.317-322
    • /
    • 2004
  • This study was performed to evaluate echocardiographic parameters in dogs with experimental mitral regurgitation subjected to dobutamine stress testing. In 8 beagle dogs, a 4-prong grasping forceps was inserted into the left ventricle through the carotid artery with fluoroscopic guidance. The disruption of chordae or mitral valve leaflet was performed. Echocardiographic protocols included quantitative Doppler echocardiography and M-mode measurement for evaluating left ventricle function. After all measurement was obtained at rest, dobutamine was infused incrementally. In stress testing, all measurement also was performed at rest as the same method. In stress Doppler echocardiography, regurgitant fraction and aortic stroke volume was increased significantly (P<0.001). Effective regurgitant orifice and regurgitant volume was not changed. In M-mode examination, fractional shortening was increased significantly at stress test (P<0.001). From the results obtained in this study, it could be suggested that dobutamine stress echocardiography increase left ventricle performance in non-functional mitral regurgitation and quantitative Doppler echocardiography is non-invasive, accurate method in valvular regurgitation.

초음파 변환기 응용을 위한 PZT/고분자 압전복합재료 (Piezoelectric Composites of PZT/polymer for Ultrasonic Transducer Applications)

  • 김진수;김용혁;김호기;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.802-805
    • /
    • 1988
  • The objective of the present study was to manufacture the piezoelectric composites of Lead Zirconate Titanate (PZT) - polymer for applications such as ultrasonic medical diagnosis and hydrophone. The PZT rod-polymer composites have been prepared with 4.5 to 57 volume percent PZT using 1.5 mm rod, so the connectivity pattern of the two phase is 1-3 type. The electromechanical coupling factors of radial mode ($k_{p}$) and thickness mode ($k_{t}$) were nearly independent of the volume percent PZT, which were 0.3 and 0.65, respectively. The acoustic impedance of the piezoelectric composites was measured by the resonance technique in the frequency range 50 KHz-1.5 MHz, which was in the range of 3.8 - 60 Mrayl.

  • PDF

저응력하의 철/크롬 올버레이합금의 긁힘마모기구 (Low streee Abrasive Wer mechanism of the Iron/Chromium Hardfacing Alloy)

  • 백응률
    • Journal of Welding and Joining
    • /
    • 제16권2호
    • /
    • pp.73-83
    • /
    • 1998
  • This study investigated the relationships between the microstructure and the wear resistance of hardfaced iron/chromium alloys to examine the low stress abrasive wear mechanism. The effects of volume fraction of reinforcing phases(chromium carbide and eutectic phase) were studied. The alloys were deposited once or twice on a mild steel plate using a self-shielding flux cored arc welding process. The low stress abrasion resistance of he alloys against dry sands was measured by the Dry Sand/Ruber Wheel Abrasion Tester (RWAT). The wear resistance of hypoeutectic alloys, below 0.36 volume fraction of chromium-carbide phase (VFC), behaved as Equal Pressure Mode (EPM) for the inverse rule of mixture whereas the wear resistance of hypereutectic alloys, above 0.36 VFC, represented Equal Wear Mode (EWM) for the linear rule of mixture.

  • PDF

비대칭 구조로 이루어진 불안정 공진기형 Nd : YAG 레이저의 빔질 분석 (Analysis of Beam Quality of the Unsymmetric Nd : YAG Laser with Unstable Resonator)

  • 김현수
    • 한국광학회지
    • /
    • 제16권5호
    • /
    • pp.456-461
    • /
    • 2005
  • 제2조화파 발생용으로 사용되는 볼록평면거울로 구성된 비대칭 불안정 공진기형 Nd:YAG 레이저의 빔질 특성을 수치적으로 분석하였다. 분석은 $M^2$, 공진기 내에서의 빔허리 직경, 모드 부피의 계산을 통해서 이루어 졌다. 수치적 계산 결과는 레이저 헤드가 볼록레이저 거울 근방에 위치한 비대칭 공진기 구조가 될 때 고효율의 제2조화파를 발생할 수 있는 조건이잘 충족됨을 보였다.