• Title/Summary/Keyword: mode split

Search Result 170, Processing Time 0.028 seconds

COMPARISON OF TWO- AND THREE-DIMENSIONAL SUPERSONIC TURBULENT FLOWS OVER A SINGLE CAVITY (단일 공동주위의 2차원과 3차원 초음속 유동 비교)

  • Woo C.H.;Kim J.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.235-238
    • /
    • 2005
  • The unsteady supersonic flow over two- and three-Dimensional cavities has been analyzed by the integration of unsteady Reynolds-Averaged Navier-Stokes(RANS) with the k - w turbulence model. The unsteady flow is characterized by the periodicity due to the mutual relation between the shear layer and the internal flow in cavities. Numerical method is upwind TVD scheme based on the flux vector split with the Van Leer limiters, and time accuracy is used explicit 4th stage Runge-Kutta scheme. Cavity flows are Comparison of two- and three-dimensional. The cavity has a L/D ratio of 3 for two-dimensional case. and same L/D and W/D ratio is 1 for three-dimensional case. The Mach and Reynolds numbers are held constant at 1.5 and 450000 respectively. For the three-dimensional case, the flow field is observed to oscillate in the 'shear layer mode' with a feedback mechanism that follow Rossiter's formula. On the other hand, the self-sustained oscillating flow transitions to a 'wake mode' for the two-dimensional simulation, with more violent fluctuations inside the cavity.

  • PDF

A Study of the Discharge Characteristics of PDP having Auxiliary Electrodes with High Xe% Working Gas

  • Jang, Jin-Ho;Lee, Don-Kyu;Ok, Jung-Woo;Kim, Deok-Won;Kim, Dong-Hyun;Lee, Hae-June;Lee, Ho-Jun;Par, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1189-1192
    • /
    • 2007
  • We propose new driving schemes, asymmetry and long gap mode, of PDP having auxiliary electrode between scan and common electrode. For the asymmetric modes, the auxiliary electrode located nearly center of the primary electrodes is connected to the scan of common electrode during all periods of reset, address and sustain. For the long gap mode, it is electrically disconnected or maintained at dc voltage of Vs/2 during sustain period except the first several sustain pulses. The proposed structure and driving method can provide higher luminous efficacy by minimizing consumption energy. The effectiveness of the new driving schemes has been investigated for various Xe partial pressure conditions.

  • PDF

Texture Cache with Automatical Index Splitting Based on Texture Size (텍스처의 크기에 따라 인덱스를 자동 분할하는 텍스처 캐시)

  • Kim, Jin-Woo;Park, Young-Jin;Kim, Young-Sik;Han, Tack-Don
    • Journal of Korea Game Society
    • /
    • v.8 no.2
    • /
    • pp.57-68
    • /
    • 2008
  • Texture Mapping is a technique for adding realism to an image in 3D graphics Chip. Bilinear filtering mode of this technique needs accesses of 4 texels to process one pixel. In this paper we analyzed the access pattern of texture, and proposed the high performance texture cache which can access 4 texels simultaneously. We evaluated using simulation results of 3D game(Quake 3, Unreal Tournament 2004). Simulation results show that proposed texture cache has high performance on the case where physical size is less then or equal 8KBytes.

  • PDF

A Continuous Network Design Model for Target-Oriented Transport Mode Choice Problem (목표지향 교통수단선택을 위한 연속형 교통망설계모형)

  • Im, Yong-Taek
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.6
    • /
    • pp.157-166
    • /
    • 2009
  • A network design problem (NDP) is to find a design parameter to optimize the performance of transportation system. This paper presents a modified NDP, called target-oriented NDP, which contains a target that we try to arrive in real world, and also proposes a solution algorithm. Unlike general NDP which seeks an optimal value to minimize or to maximize objective function of the system, in target-oriented NDP traffic manager or operator can set a target level prior and then try to find an optimal design variable to attain this goal. A simple example for mode choice problem is given to test the model.

LDPC Decoding Algorithm for Multi-level Modulation Scheme (멀티레벨 변조방식에서 LDPC 복호 알고리즘)

  • Lee In-Ki;Jung Ji-Won;Choi Duk-Gun;Choi Ean-A;Chang Dae-Ig;Oh Duk-Gil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.6C
    • /
    • pp.434-441
    • /
    • 2005
  • For LDPC decoding, received symbols are splitted bit by bit based using the received in-phase and quadrature components. The method of bit-splitting is affected on decoding performance because its method depend on distance over symbol constellation. Therefore this paper propose the bit split method using the sector information with sacrifice a little performance loss compared to Euclidean distance method. Futhermore DVB-S2 specification supports BC(Backward Compactible) mode which using the hierarchical modulation method, this paper also analyze the decoding performance according to deviation angle of 8PSK constellation for various LDPC coding rates.

Element loss analysis of concentrically braced frames considering structural performance criteria

  • Rezvani, Farshad Hashemi;Asgarian, Behrouz
    • Steel and Composite Structures
    • /
    • v.12 no.3
    • /
    • pp.231-248
    • /
    • 2012
  • This research aims to investigate the structural behavior of concentrically braced frames after element loss by performing nonlinear static and dynamic analyses such as Time History Analysis (THA), Pushdown Analysis (PDA), Vertical Incremental Dynamic Analyses (VIDA) and Performance-Based Analysis (PBA). Such analyses are to assess the potential and capacity of this structural system for occurrence of progressive collapse. Besides, by determining the Failure Overload Factors (FOFs) and associated failure modes, it is possible to relate the results of various types of analysis in order to save the analysis time and effort. Analysis results showed that while VIDA and PBA according to FEMA 356 are mostly similar in detecting failure mode and FOFs, the Pushdown Overload Factors (PDOFs) differ from others at most to the rate of 23%. Furthermore, by sensitivity analysis it was observed that among the investigated structures, the eight-story frame had the most FOF. Finally, in this research the trend of FOF and the FOF to critical member capacity ratio for the plane split-X braced frames were introduced as a function of the number of frame stories.

A 2.4-GHz Dual-Mode CMOS Power Amplifier with a Bypass Structure Using Three-Port Transformer to Improve Efficiency (3-포드 변압기를 이용한 바이패스 구조를 적용하여 효율이 개선된 이중 모드 2.4-GHz CMOS 전력 증폭기)

  • Jang, Joseph;Yoo, Jinho;Lee, Milim;Park, Changkun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.6
    • /
    • pp.719-725
    • /
    • 2019
  • We propose a 2.4-GHz CMOS power amplifier (PA) with a bypass structure to improve the power-added efficiency (PAE) in the low-power region. The primary winding of the output transformer is split into two parts. One of the primary windings is connected to the output of the power stage for high-power mode. The other primary winding is connected to the output of the driver stage for low-power mode. Operation of the high power mode is similar to conventional PAs. On the other hand, the output power of the driver stage becomes the output power of the overall PA in the low power mode. Owing to a turning-off of the power stage, the power consumption is decreased in low-power mode. We designed the CMOS PA using a 180-nm RFCMOS process. The measured maximum output power is 27.78 dBm with a PAE of 20.5%. At a measured output power of 16 dBm, the PAE is improved from 2.5% to 12.7%.

Probabilistic modeling of geopolymer concrete using response surface methodology

  • Kathirvel, Parthiban;Kaliyaperumal, Saravana Raja Mohan
    • Computers and Concrete
    • /
    • v.19 no.6
    • /
    • pp.737-744
    • /
    • 2017
  • Geopolymer Concrete is typically proportioned with activator solution leading to moderately high material cost. Such cost can be enduring in high value added applications especially when cost savings can be recognized in terms of reduction in size of the members. Proper material selection and mix proportioning can diminish the material cost. In the present investigation, a total of 27 mixes were arrived considering the mix parameters as liquid-binder ratio, slag content and sodium hydroxide concentration to study the mechanical properties of geopolymer concrete (GPC) mixes such as compressive strength, split tensile strength and flexural strength. The derived statistical Response Surface Methodology is beleaguered to develop cost effective GPC mixes. The estimated responses are not likely to contrast in linear mode with selected variables; a plan was selected to enable the model of any response in a quadratic manner. The results reveals that a fair correlation between the experimental and the predicted strengths.

차세대 SAR 활용을 위한 이중 채널 항공기 SAR 시스템 구축 및 간섭기법 연구

  • Kim, Deok-Jin;Jeong, Jeong-Gyo;Kim, Seung-Hui
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.10-20
    • /
    • 2014
  • 지금까지 대부분의 인공위성 또는 항공기 SAR 시스템은 하나의 위상 배열 안테나를 이용하며, 단 영상을 생성하고 판독하는데 주로 사용되었지만, 차세대 SAR 시스템은 다중 편파 관측이 가능하거나 이중 채널 또는 위상 배열 안테나의 분리 모드(split-antenna mode)를 통해 간섭기법의 적용이 가능한 시스템으로 발전이 이루어지고 있다. 이러한 측면에서 이 논문은 차세대 SAR 인공위성의 새로운 분석 기법 연구와 활용 증진을 위해, 유사한 기능을 보일 수 있는 이중 채널 항공기 SAR 시스템을 구축하고, 이로부터 단일 패스 간섭기법(single-pass interferometry)을 연구한 논문이다. 공간적으로 서로 다른 위치에 있는 두 개의 SAR 채널에서 동시에 수신된 레이다 신호를 간섭적으로 처리하여, 지형의 고도 정보를 추출하거나 이동하는 물체의 속도를 탐지할 수 있도록 알고리즘을 구현하였고, 새로운 활용 분야를 모색하고자 하였다.

An Improved Single-Phase Full-Bridge ZVS Inverter with a Subtractive Coupled Magnetics

  • Soh, Jae-Hwan;Lim, Jong-Yeop;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1835-1841
    • /
    • 2017
  • An improved single-phase full-bridge zero-voltage-switching inverter using a subtractive coupled magnetics is proposed in this paper. The proposed topology overcomes several drawbacks of the conventional ARCPI zero-voltage-switching inverter including two bulky capacitors which can cause problems such as the need for a protection circuit and voltage fluctuation of split capacitors. Also the proposed topology can reduce the number of devices required for ZVS through a simplified auxiliary circuit, thus achieving low cost and small volume and is applicable a modified unipolar PWM scheme. Detail mode analysis and design considerations are provided for optimal efficiency. In the end, the effectiveness and feasibility of the proposed topology are verified experimentally under various conditions.