• 제목/요약/키워드: mode converter

검색결과 1,213건 처리시간 0.036초

전류모드제어를 적용한 직류전원장치의 해석 및 보상에 관한 연구 (The Analysis and Compensation of DC to DC Converter with Current Mode Controller)

  • 김철진;김영태;송요창
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권5호
    • /
    • pp.230-237
    • /
    • 2003
  • Current mode control has been used for DC to DC converters for over twenty years. There are many different control schemes which use the inductor current signal in one way or another to control the DC to DC converter. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the guarantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test result. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency fc is early 1/5 of switching frequency, fs, from the experimental result with frequency response analyzer.

Compensation Technique for Current Sensorless Digital Control of Bridgeless PFC Converter under Critical Conduction Mode

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2310-2318
    • /
    • 2018
  • Critical conduction mode (CRM) operation is more efficient than continuous conduction mode (CCM) operation at low power levels because of the valley switching of switches and elimination of the reverse recovery losses of boost diodes. When using a sensorless digital control method, an error occurs between the actual and the estimated current. Because of the error, it operates as CCM or discontinuous conduction mode (DCM) during CRM operation and also has an adverse effect on THD of input current. In this paper, a current sensorless technique is presented in an inverter system using a bridgeless boosted power factor correction converter, and a compensation method is proposed to reduce CRM calculation error. The validity of the proposed method is verified by simulation and experiment.

방향 절환이 자유로운 양방향 DC/DC 컨버터 개발 (Development of a Bidirectional DC/DC Converter with Smooth Transition Between Different Operation Modes)

  • 유창규;이우철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권4호
    • /
    • pp.224-230
    • /
    • 2006
  • The conventional way to implement a bidirectional converter with boost/buck has been to use two general purpose PWM ICs with a single supply voltage. In this case, when one direction mode is in operation, the other is disabled and the output of the error amplifier of the disabled IC may be saturated to a maximum value or zero. Therefore, during mode transition, a circuit which can disable the switching operation for a certain time interval is required making it impossible to get a seamless transition. In this paper, the limitations of the conventional 42V/14V bi-directional DC/DC converter implemented with general current mode PWM ICs with a single supply voltage are reviewed and a new current mode PWM controller circuit with a dual voltage system is proposed. The validity of the proposed circuit is investigated through simulation. and experiments.

폴링된 폴리머 광도파로의 광축을 조절하여 제작한 수동형 편광 변환기 (Passive Polarization Converter Fabricated by Controlling Optic Axis of Poled Polymer Waveguides)

  • 오민철;신상영
    • 전자공학회논문지A
    • /
    • 제32A권12호
    • /
    • pp.166-172
    • /
    • 1995
  • A novel passive TE/TM polarization mode converter is fabricated by using poled polymer waveguides. The optic axis of the poling induced waveguide is slowly rotated by using a slowly varying structure of poling electrodes. Thus the polarization conversion is achieved as the guided mode propagates through the waveguide. The proposed device is simulated by a full vectorial beam propagation method (VBPM) for anisotropic medium. For the rotation length of 1 mm, the TE polarization of the guided mode is successfully converted to the TM polarization with negligible loss. Based on the simulation results, we fabricated the polarization converter which is tested by using 1.3 $\mu$m laser diode. TE to TM mode conversion is observed with a polarization extinction ratio higher than 30 dB, and the excess loss is less than 1 dB. The polarization conversion is relatively insensitive to wavelength since the device contains no periodic structures. These devices are easier to fabricate than others containing periodic structures.

  • PDF

개선된 전파형 ZVT-PWM DC-DC 컨버터 (Improved full wave mode ZVT-PWM DC-DC Converters)

  • 김태우;강안종;진기호;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.777-780
    • /
    • 2003
  • In this paper, an improved full wave mode ZVT-PWM DC-DC Converter is presented to maximize the regeneration ratio of resonant energy by only putting an additional diode in series with auxiliary switch. The operation of auxiliary switch in a half wave mode makes possible the soft switching condition of all switches. Furthermore, the increase of the regeneration ratio to resonant energy results in low conduction losses and minimum voltage and current stresses. The operation principles of the proposed converters are analyzed using the PWM boost converter topology as an example. Theoretically analysis and experimental results verify the validity of the boost converter topology with the proposed full wave mode ZVT-PWM converters

  • PDF

A Differential Current-to-Time Interval Converter Using Current-Tunable Schmitt Triggers

  • Chung, Won-Sup
    • 전기전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.375-380
    • /
    • 2017
  • A differential current-to-time interval converter is presented for current mode sensors. It consists of a ramp voltage generator, a current mode sensor, a reference current source, two current-tunable Schmitt triggers, a one-shot multivibrator, and two logic gates. The design principle is to apply a ramp voltage to each input of the two current-tunable Schmitt triggers whose threshold voltages are proportional to the drain current values of the current mode sensors. A proposed circuit converts a current change in the ISFET biosensor into its equivalent pulse width change. A prototype circuit built using TSMC 0.18 nm CMOS process exhibit a conversion sensitivity amounting to $726.9{\mu}s/pH$ over pH variation range of 2-12 and a linearity error less than ${\pm}0.05%$.

3레벨 4레그 PWM 컨버터의 커먼 모드 전압 저감 (Common-mode Voltage Reduction of Three Level Four Leg PWM Converter)

  • 지승준;고상기;김현식;설승기
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.488-493
    • /
    • 2014
  • This paper presents a carrier-based pulse-width modulation(PWM) method for reducing the common-mode voltage of a three-level four-leg converter. The idea of the proposed PWM method is intuitive and easy to be implemented in digital signal processor-based converter control systems. On the basis of the analysis of space-vector PWM(SVPWM) and sinusoidal PWM(SPWM) switching patterns, the fourth leg pole voltage of the three-phase converter called "f leg pole voltage" is manipulated to reduce the common-mode voltage. To synthesize f leg pole voltage for the suppression of the common-mode voltage, positive and negative pole voltage references of f leg are calculated. An offset voltage is also deduced to prevent the distortion of a, b, and c phase voltages. The feasibility of the proposed PWM method is verified by simulation and experimental results. The common-mode voltage of the proposed PWM method in peak-to-peak value is 33% in comparison with that of the conventional SVPWM method. The transition number of the common-mode voltage is also reduced to 25%.

전류 제어 비대칭 하프 브릿지 직류-직류 컨버터의 동특성 해석 및 제어회로 설계 (Dynamic Analysis and Control Design of Current-Mode Controlled Asymmetrical Half-Bridge DC-To-DC Converters)

  • 임원석;최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.337-340
    • /
    • 2003
  • This paper presented practical details about control-loop design and dynamic analysis for a peak current-mode controlled asymmetrical half-bridge(ASHB) do-to-dc converter, Graphical loop gain method is used to design the feedback compensation and analyze the closed-loop performance of ASHB converter. The results of the control design and closed-loop analysis are validated by experiments on a prototype converter.

  • PDF

PC 전원용 다중출력 포워드 컨버터의 가중치 전압 모드 제어 (Weighted Voltage Mode Control of Multiple Output Forward Converter for PC Power Supply)

  • 차영길
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.501-504
    • /
    • 2000
  • In this paper the PC power supply is studied from the point of system stability. The power stage model of a multiple output forward converter with weighted voltage mode control is derived including all the major parasitic components and the small signal model is also derived. Determination of the weighting factors and a design procedure for the loop compensation are presented. Finally the model is verified through the simulation of three output forward converter with SABER.

  • PDF

프로그래머블 전류모드 폴딩 . 인터폴레이션 CMOS A/D 변환기 설계 (Design of a programmable current-mode folding/interpolation CMOS A/D converter)

  • 김형훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.45-48
    • /
    • 2001
  • An programmable current-mode folding and interpolation analog to digital converter (ADC) with programmable interpolator is proposed in this paper. A programmable interpolator is employed not only to vary the resolution of data converter, but also to decrease a power dissipation within the ADC. Because of varying the number of interpolation circuits, resolution is vary from 6 to 10bit. The designed ADC fabricated by a 0.6${\mu}{\textrm}{m}$ n-well CMOS double metal/single poly process. The experimental result shows the power dissipation from 26 to 87mW with a power supply of 3.3V.

  • PDF