• Title/Summary/Keyword: mode converter

Search Result 1,214, Processing Time 0.031 seconds

Broadband Noise Reduction of Smart Panels using Piezoelectric Shunt Circuits (압전션트 회로를 이용한 지능패널의 광대역 소음저감에 관한 연구)

  • 정영채;김재환;이중근;하성호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.624-629
    • /
    • 2003
  • In this paper, broadband shunt technique for increasing transmission loss is experimentally investigated. Piezoelectric shunt damping is studied using resonant shunt circuit and negative capacitor shunt circuit. A resonant shunt circuit is implemented by using a resistor and inductor. Negative Capacitor shunt damping is similar in nature to resonant shunt damping techniques, as a single piezoelectric material is used to dampen multi-mode. Performance of both methods is experimentally studied for noise reduction. This is based upon SAE J1400 test method and a transmission loss measurement system is provided for it. This paper will present the test setup fer transmission loss measurement and the tuning procedure of shunt circuits. Finally the results of sound transmission tests will be shown.

  • PDF

The Resonant Flyback Converter for DLP Projector (DLP 프로젝터용 공진형 플라이백 컨버터)

  • Park, Woo-Chol;Yoo, Byoung-Seon;Kim, Chang-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.986-987
    • /
    • 2006
  • 준공진형 플라이백 컨버터를 사용하여 Full HD급 DLP 프로젝터용 컨버터 설계에 대해 고찰하였다. 소형 경량화 시키기 위한 방법으로 Full Mode Packaging 형태로 절연설계에 유리하게 하였고, Shidegn사의 MR4040을 사용하여 부분공진 스위칭 동작에 의해 고효율 저노이즈를 실현하였다. 중부하 시 스위칭 주파수는 35KHz, 경부하시 스위칭 주파수는 최대 200KHz이고 입력전압 AC $90{\sim}264$[v], 출력전력 66W급의 컨버터을 제작하였으며 측정된 효율은 최고 93% 이다.

  • PDF

The design of an ASIC chip for synchronization between main and sub pictures in the multi channel TV system (멀티채널 TV 시스템에서 주화면과 부화면간의 동기화를 위한 ASIC 칩 설계)

  • 백승웅;선우명훈
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.2
    • /
    • pp.19-28
    • /
    • 1997
  • This paper presents the design of an SSIC chip for synchronization between main and sub pictures in the multi channel TV system (MUCTS). This chip can resolve problems in MUCTS, such as passing through and vertical jolt phenomena. In addition, this chip rpvivides compatibility for normal/doulble scan, interlace/progressive and normal (4:3)/wide (16:9) systems and has high hjorizontal and vertical resolutions (340) dots and 150 lines). In each mode there are 1 channel, 3 channel, and 4 position display functions. This MUCTS chip including three A/D coverters, a D/A converter and seven line memories was fabricated with one chip by using the $0.8\mu\textrm{m}$ CMOS technology. The application areas of this MUCTS ASIC chip include the wide TV, projection TV and te next generation TV for the DBS (direct broadcast system).

  • PDF

A Study on the Dual PWM Digital Excitation System of Regeneration Type (회생형 이중화 PWM 방식의 디지털 여자시스템에 관한 연구)

  • Ryu, Ho-Seon;Lee, Joo-Hyun;Lim, Ick-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.79-84
    • /
    • 2010
  • This paper discusses the control of generator field using dual IGBT PWM regeneration method to target brushless synchronous generator. If one of PWM bridges happens to fault, it transfers automatically and can be in charge of full load. Also it has an advantage of the operation which UPS connected in parallel with PWM bridge can supply power to excitation system in condition of main power loss. This PWM system supplies field current to generator in one quadrature operation, regenerates field coil energy to main power supplier in four quadrature operation. We designed, manufactured and applied the first trial product at J-power plant.

Power Quality Measurement System of using PLC (전력선통신을 이용한 전력품질 측정시스템)

  • Hong, Duc-Pyo;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.90-92
    • /
    • 2005
  • As the developing of industry, the nonlinear equipments as inverter, converter, SMPS(Switching Mode Power Supply) and motor have been increased. But the sensitive electronic loads to the power quality, such as computer's and other electronic equipments, have been spreaded out very fast. Thus, the power quality (PQ) problems and the real time power quality monitoring (PQM) are one of the important issues industry and building area for the intelligent control of the systems. One of them, PQM using PLC(Power Line Communication) have good merits that can send and receive the PQ information without any new network line. This paper presents the PQM hardware and software to monitor the PQ information by using PLC that meets the categories of IEEE Std. 1159.

  • PDF

Study on Grid-Connected Photovoltaic System using Current-Source Inverter (전류형 인버터를 이용한 계통 연계형 태양광 발전 시스템에 관한 연구)

  • Lim, J.M.;Park, S.J.;Lee, S.H.;Moon, C.J.;Choi, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.677-681
    • /
    • 2005
  • This Paper presents a 6 pulse shift operation control mode of current-source-inverter to make improvement of efficiency and to reduce the frequency of inverter switching for photovoltaic generation system using PWM current-source-inverter. This system is connected solar cell energy directly without using a storage cell. The proposed circuit can maintain maximum voltage of photovoltaic generation of take advantage of six Buck-Boost converter and a full-bridge inverter determines the polarity of AC output. That is controlled by using digital signal processor TMS320F2812 for operation about a 6 pulse shift operation control of current-source-inverter, and it is verified through the experimental results.

  • PDF

A High Efficiency Power Conversion Circuit with Wide ZVS Range for Sustaining Power Module of Large Size PDP (넓은 영전압 스위칭 범위를 갖는 대화면 PDP용 유지 전원단을 위한 고효율 전력 변환 회로)

  • Park, K.H.;Lee, W.J.;Youn, M.J.;Moon, G.W.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.279-282
    • /
    • 2005
  • Recently, due to the launching of digital broadcasting service, a demand of PDP TV with large screen size is sharply rising. PDP power module is mainly divided into power factor correction (PFC) stage and sustaining power stage. Especially, sustaining power module has pulsating load characteristics. So, the hard switching at light load condition causes low efficiency and thermal problem. Therefore, a new power conversion circuit for sustaining power module of 60' PDP is proposed whose ZVS is obtained by additional ZVS tank. This paper presents properties of the proposed converter through mode analysis, numerical analysis. And a 900w prototype for sustaining power module of 60' PDP is produced to verify the analytic results. As an experimental results, ZVS is achieved from full load to 10% load variation and more than 92% of high efficiency is obtained at 10% load condition.

  • PDF

High Efficiency and High Power Density 3-Level Power Factor Correction Converter (고효율 및 고전력밀도 3-레벨 PFC 컨버터)

  • Yang, Jung-woo;Ji, Sang-Keun;Kang, Jeong-il;Han, Sang-Kyoo
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.207-209
    • /
    • 2018
  • 본 논문은 고효율 및 고전력밀도 3-레벨 PFC(Power Factor Correction) 컨버터를 제안한다. 기존 PFC의 고 전력밀도를 위한 스위칭 주파수 상승은 스위칭 특성이 우수한 소자를 적용하거나, 별도의 스너버 회로가 요구되므로 설계가 복잡하며 고전력밀도 달성에 한계가 있다. 제안 PFC 컨버터는 3-레벨 방식을 적용하여 각 스위칭 소자의 전압 스트레스를 절반으로 감소시켰으며, 스위치 손실 저감을 통한 고속 스위칭 동작으로 리액티브 소자의 고밀도화를 달성하였다. 또한, 기존의 3-레벨방식은 디지털 제어를 통해 스위칭 소자의 전압 평형이 이루어졌지만, 본 논문에서는 아날로그 IC에 전압 평형을 위한 RC Delay 회로와 소수의 SMD(Surface-mount devices) 소자만을 이용하여 별도의 제어회로 없이 전압 평형이 가능하므로 고 전력밀도 달성에 유리하다. 제안회로의 타당성을 검증하기 위해 CRM(Critical conduction mode) PFC 컨버터를 기반으로 250W급 시작품 제작을 통한 실험 결과를 제시한다.

  • PDF

A New Classification of HEV's and a New Breed of HEV's (HEV의 새로운 분류방법과 새로운 형태의 HEV)

  • Jeon, Seong-Jeub;Park, Han-Seok;Lee, Won-Chang;Noh, Eui-Cheol;Kim, In-Dong;Kim, Man-Go
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.27-30
    • /
    • 1999
  • In this paper HEV's are newly classified and a new breed of HEV's, which is called series-parallel compensated configuration is also presented. In this configuration the engine can be operated on constant-speed and constant-torque mode, while the power converter can be small-sized.

  • PDF

Short-term Run and Short-circuit Test of 6.6㎸/200A DC reactor Type Superconducting Fault Current Limiter (6.6㎸/200A급 DC 리액터헝 초전도한류기의 단시간운전 및 단락시험)

  • 안민철;이승제;강형구;배덕권;윤용수;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.10-13
    • /
    • 2003
  • 6.6㎸rms/200Arms DC reactor type superconducting fault current limiter (SFCL) has been developed. This paper deals with the manufacture and short-circuit test of the SFCL. DC reactor was the HTS solenoid coil whose inductance was 84mH. AC/DC power converter was performed as the dual-mode operation. The short-term run(1 sec) and short-circuit test of this SFCL was performed successfully. The experimental results have a similar tendency to the simulation results. In short-circuit test, at 2 cycles after the fault, fault current limitation rate was about 30%.

  • PDF