• Title/Summary/Keyword: mock-up wall

Search Result 98, Processing Time 0.025 seconds

A study on the improvement of The standard specifications for Mock-up Test in the Curtain-wall construction (Curtain-wall공사에 있어서 Mock-up Test 건축공사표준시방서의 개선 방안에 관한 연구)

  • Lee Jin-Man;Kang Jae-Wang;Son Yong-Geun;Kim Chang-Duk
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.491-494
    • /
    • 2003
  • Curtain wall (for the outside wall) must be designed and constructed to resist weather condition of nature like rain. wind and surrounding environment. So, Now days, Mock-up test of curtain wall's total capability is generally used for skycraft building. But, Mock-up test specification in korea is so weak that there are lots of disputation. Also, lacking of clearness in specification causes many trouble in adaptation. Therefore, I would like to consider the problem of Mock-up test specification by inspecting and comparing with other country's works. and I will mention the way of approvement in our specification.

  • PDF

Performance Evaluations of Mock-up Tests for ALC Panel Curtain Wall in Building Exterior (ALC 패널을 활용한 건축물 외장 커튼월에 대한 Mock-up Test 성능 평가 연구)

  • Kim, Young-Ho;Lee, Yong-Soo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.4
    • /
    • pp.25-32
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the exterior materials or curtain wall system. The curtain wall system is a element that come to insulated portions of building envelope that results in heat loss. The purpose of this paper is to carried out mock-up tests for exterior wall used in autoclaved lightweight concrete panels in green building practices. Mock-up test execute a mixed process between standard test procedure and complex test procedure based on AAMA 501(American Society for Testing and Materials) and ASTM 283, ASTM 330(American Society for Testing and Materials). In results, tests meet the requirements that grant values in steps of procedures provided on ASTM and AAMA. ALC panel is suitable for a exterior wall product to be gratified thermal cycling performance and structural capacity, deflection(H/200) and lateral displacement(H/50), for curtain walls.

Construction of Aluminum Curtain Wall with 3D Elevation for TRUTEC Building (트루텍 빌딩의 3차원 입체 커튼월 시공)

  • Park, Choel;Hong, Doo-Pyo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.119-122
    • /
    • 2007
  • TRUTEC building, which is located at DMC B block is zone, is just one the office building in Soeul. TRUTEC building is designed by Barkow Leibinger Architeken in Germany, has 5 stories under and 12 stories above and has been finished with the unique three dimensional curtain wall unit. Big trial to make unique elevation succeeded as getting rid of the typical plain curtain wall unit. In addition, aluminum bars are treated by the latest CNC machine in order to achieve 3D section. Construction of curtain wall is highly focused from the moment of contract to keep the schedule because the contract period is 18 months. Regular design meeting and technical meeting between stakeholders including construction manager, designer, engineer, consultant and so on have been held during the construction to minimize the risks from the unique elevation and trial. Step by step mock-up test (design mock-up and visual mock-up on site) has been performed before functional mock-up test.

  • PDF

The Mock-Up Test for Applying Rebar Modularization to the Wall of Nuclear Power Plant (원전 벽체구조물의 철근모듈화 적용을 위한 Mock-Up 실험연구)

  • Lee, Byung-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.7-8
    • /
    • 2016
  • We are developing the technology for applying the Rebar Modularization Method to the Nuclear Power Plant Structures. To achieve this, we had developed the elementary technology for applying this method to Nuclear Power Plant Structures efficiently and performed the Mock-Up Test by using the developed elementary technology. By analysing this test result, we deduced the problems and found solutions to solve them.

  • PDF

Mock-up Test of Exposed Concrete Wall using Self Compacting Concrete (노출 구조물 벽체에 적용하기 위한 무다짐 콘크리트 실물모형 실험)

  • 김규동;이승훈;손유신;김한준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.561-566
    • /
    • 2002
  • Recently, high quality exposed concrete is needed to achieve high quality surface for outer wall of the building. In this study, to solve above characteristic of the exposed concrete we selected self compacting concrete(SCC) and compared with normal concrete. So, we developed the SCC mix design and performed the semi mock-up test. Through this result, we performed the pilot test and mock-up test to check surface of outer wall and to measure formwork pressure As a result because SCC is better than normal concrete with respect to flowability and seggregation resistance SCC is suit to a exposed concrete needed high quality surface for outer wall of the building.

  • PDF

Comparison of Panel STLs for Ships Measured in Laboratory and Mock-up (선박용 판넬의 음향투과손실(STL)의 실험실법 측정과 Mock-up 측정값의 비교)

  • Kim, Hyun-Sil;Kim, Bong-Ki;Cha, Sun-Il;Kim, Young-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.69-72
    • /
    • 2005
  • In this paper, FSTL(field sound transmission loss) measured in the mock-up is studied and compared to the STL measured in laboratory. A mock-up is built by using 6t steel plate, and two identical cabins are made where 25t or 50t panel is used to construct wall and ceiling inside the steel structure. Various wall panels and ceilings are tested, where the effects of U/T, sealing, panel thickness, ceilings are studied. It is shown that the effect of ceiling thickness is negligible and FSTL is lower than STL by 5-7 dB due to several flanking paths.

  • PDF

A Study on the Mock up Test for Reduction of HCHO Using the Functional Gypsum Board (기능성 석고보드의 폼알데히드(HCHO) 저감성능 평가를 위한 실물시험(Mock up test)연구)

  • Kim, Hea-Jeong;Song, Kyoo-Dong;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.814-819
    • /
    • 2008
  • The purpose of this study was developing the building materials for creation the comfortable IAQ. By reducing formaldehyde(HCHO) known as the main factors of Sick House Syndrome. This material must be revealed the physical and eco-friendly performance, so this study set up the basic standards for building materials. The source of physical performance evaluation is Korea Industrial Standards and the base of environmental ability is the Eco Label considering certificated system related to an apartment house. Because the developed material was satisfied with the established standards, it was tested in mock-up room for obtaining the real date from indoor air. The mock-up test was conducted according environmental standard method for indoor air Quality of the ministry of environment. The result of this study were as follows; the functional building materials had a effect to reduce the formaldehyde concentration for a initial period without wall paper, so additional development is needed for application with the wall paper and the available period.

Mock-up Model of the Environment Assessment Study on Red-clay and Cement (Mock-up모델을 이용한 황토 및 시멘트의 환경요소 평가 연구)

  • Choi, Yool;Song, Hyeun-Guen
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study is to measure the environmental effects of different alternative building materials. The following building materials were tested: clay bricks, cement wall, and red-clay plaster. Four mock-up models were constructed using clay bricks, cement wall, red-clay plaster and the last model as the control model. The effects of the above four building materials on temperature, humidity, the emissions of formaldehyde, and V.O.C were measured. This experiment was conducted during September. The conclusions are as follows. Clay bricks were able to control temperature, humidity and filter formaldehyde by itself. The environment within the cement wall was not affected by the humidity changes outside. Red-clay plaster walls had little impact on the environment because it is very thin.!

A Study on the comparison of Infill Technology between Korea long life Apartment Mock up House and Japan KSI experimental House (국내 장수명 공동주택 Mock-up House와 일본 KSI 실험주택 인필 요소기술 비교 연구)

  • Choi, Young Ho;Kim, Shin;Kim, Sung Wan
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.63-69
    • /
    • 2008
  • The thesis is a comparative analysis of Infill Technologies between Korea's long-life Mock-up House, a study driven by 'Durability and Flexibility of Long-life Housing Technology Development' of R&D, and Japan's KSI experimental house, the major example of Japan's long-llfe housing. In terms of the domestic Mock-up House, a system of building the floor first was applied. The floor material of each housing unit required a development of dry heating component that is partially substitutable in order to avoid conflict with the finishing. Also, a development of a floor system that can counteract against the construction inaccuracy was required. In the Case of an outer wall, need to make the wall with the chassis. In the case of ceiling, need to develop the double ceiling system which is good for sound insulation. Also, in comparison to KSI experimental house in Japan, it would require to develop a wiring system of the ceiling which can react to the movement of the wall. Especially, to assure the flexible nature of an internal wall, it would desperately require the research and development of the products related to components and flexible system of mechanical/electrical/communication parts as well as supporting institutionalized system for this development. Furthermore, for KSI experimental house in Japan, it would be necessary to formulate a construction manual as well as a systematic and practical planning guide to invent a new interface rule which will secure simplicity of assembling, dismantling, installation and replacement of architectural components for which research development is quite insignificant at the moment. This effort will have to continue to give a solid direction for better application of such reference manual during construction and development of long life span apartment by public sector as well as private corporations.

High Heat Flux Test of Cu/SS Mock-up for ITER First Wall (ITER 일차벽의 Cu/SS Mock-up에 대한 고열부하 시험)

  • Lee, D.W.;Bae, Y.D.;Hong, B.G.;Lee, J.H.;Park, J.Y.;Jeong, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.325-330
    • /
    • 2006
  • In order to verify the integrity of the first wall (FW) of the International Thermonuclear Experimental Reactor (ITER), the fabricated Cu/SS mock-up is tested in the JAEA Electron Beam Irradiation Test Stand (JEBIS). To fabricate the Cu/SS mock-up, CuCrZr and 316L authentic stainless steel (SS316L) are used for Cu alloy and steel, respectively The hot isostatic pressing (HIP) is used as a manufacturing method with a $1050^{\circ}C$ and 150 MPa. The high heat flux (HHF) test is performed using an electron beam with a heat flux of $5MW/m^2$ and a cycle of 15-sec on time and 30-sec off time. The temperature measurement in the HHF test shows good agreement with the results obtained from ANSYS code analysis, which is used for determining the HHF test conditions.