• Title/Summary/Keyword: mobile medical applications

Search Result 82, Processing Time 0.031 seconds

The use of mobile computing devices in microsurgery

  • Pafitanis, Georgios;Hadjiandreou, Michalis;Miller, Robert;Mason, Katrina;Theodorakopoulou, Evgenia;Sadri, Amir;Taylor, Kirsten;Myers, Simon
    • Archives of Plastic Surgery
    • /
    • v.46 no.2
    • /
    • pp.102-107
    • /
    • 2019
  • Mobile computing devices (MCDs), such as smartphones and tablets, are revolutionizing medical practice. These devices are almost universally available and offer a multitude of capabilities, including online features, streaming capabilities, high-quality cameras, and numerous applications. Within the surgical field, MCDs are increasingly being used for simulations. Microsurgery is an expanding field of surgery that presents unique challenges to both trainees and trainers. Simulation-based training and assessment in microsurgery currently play an integral role in the preparation of trainee surgeons in a safe and informative environment. MCDs address these challenges in a novel way by providing valuable adjuncts to microsurgical training, assessment, and clinical practice through low-cost, effective, and widely accessible solutions. Herein, we present a review of the capabilities, accessibility, and relevance of MCDs for technical skills acquisition, training, and clinical microsurgery practice, and consider the possibility of their wider use in the future of microsurgical training and education.

Internet of Things: An Overview and its Applications in Aviation (항공 분야에서의 사물인터넷 기술 현황)

  • Hyun, WooSeok
    • Korean journal of aerospace and environmental medicine
    • /
    • v.30 no.3
    • /
    • pp.100-107
    • /
    • 2020
  • Internet of Things (IoT) is a technology that communicates data between devices, which are things, using an embedded sensor connected through network backbone such as the internet. Here, data communication technology, sensor technology, and actuator (interface) technology are fused into IoT and it turns devices into smart things. As a result, vast sized data are being generated and that data is being processed into useful actions that can control the things that are devices to make our lives much fruitful. Nowadays, the IoT, early defined as Machine-to-Machine (M2M) connection, becomes a key technology powered by growing innovation of wireless communication trends in the internet connectivity through mobile networking. This paper gives an overview of Internet of Things and brief information about major technologies and its applications in various fields focusing aviation.

Ecological Momentary Assessment Using Smartphone-Based Mobile Application for Affect and Stress Assessment

  • Yang, Yong Sook;Ryu, Gi Wook;Han, Insu;Oh, Seojin;Choi, Mona
    • Healthcare Informatics Research
    • /
    • v.24 no.4
    • /
    • pp.381-386
    • /
    • 2018
  • Objectives: This study aimed to describe the process of utilizing a mobile application for ecological momentary assessment (EMA) to collect data on stress and mood in daily life setting. Methods: A mobile application for the Android operating system was developed and installed with a set of questions regarding momentary mood and stress into a smartphone of a participant. The application sets alarms at semi-random intervals in 60-minute blocks, four times a day for 7 days. After obtaining all momentary affect and stress, the questions to assess the usability of the mobile EMA application were also administered. Results: The data were collected from 97 police officers working in Gyeonggi Province of South Korea. The mean completion rate was 60.0% ranging from 3.5% to 100%. The means of positive and negative affect were 18.34 of 28 and 19.09 of 63. The mean stress was 17.92 of 40. Participants responded that the mobile application correctly measured their affect ($4.34{\pm}0.83$) and stress ($4.48{\pm}0.62$) of 5-point Likert scale. Conclusions: Our study investigated the process of utilizing a mobile application to assess momentary affect and stress at repeated times. We found challenges regarding adherence to the research protocol, such as completion and delay of answering after alarm notification. Despite this inherent issue of adherence to the research protocol, the EMA still has advantages of reducing recall bias and assessing the actual moment of interest at multiple time points that improves ecological validity.

Development of a Portable SpO2-based Biosignal Monitoring System (SpO2 기반 휴대형 생체 신호 모니터링 시스템 개발)

  • Lee, Hyung-Bong;Park, Sung-Wook;Chung, Tae-Yun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.5
    • /
    • pp.273-283
    • /
    • 2013
  • The traditional medical equipments are devices used by medical professionals but not used in public environment. Common people, however, require light-weight medical devices to make healthcare for themselves nowadays. Those medical devices are used to monitor personal health status such as blood pulse, blood pressure, diabetes. Also, some of them are operated in mobile environment called u-healthcare. This paper implements a portable healthcare system composed of $SpO_2$(Saturation of Partial Pressure Oxygen) sensors and a gateway for detecting hypoxemia during people's leasure activity such as climbing or hiking. The $SpO_2$ sensor is designed as watch style to support dynamic exercise and the gateway is designed as necklace style to support the elderly. The result of a performance evaluation shows that the performance of the $SpO_2$ sensor using reflection technology is not lower than that of a clairvoyant styled $SpO_2$ sensor.

Attention-Based Heart Rate Estimation using MobilenetV3

  • Yeo-Chan Yoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.12
    • /
    • pp.1-7
    • /
    • 2023
  • The advent of deep learning technologies has led to the development of various medical applications, making healthcare services more convenient and effective. Among these applications, heart rate estimation is considered a vital method for assessing an individual's health. Traditional methods, such as photoplethysmography through smart watches, have been widely used but are invasive and require additional hardware. Recent advancements allow for contactless heart rate estimation through facial image analysis, providing a more hygienic and convenient approach. In this paper, we propose a lightweight methodology capable of accurately estimating heart rate in mobile environments, using a specialized 2-channel network structure based on 2D convolution. Our method considers both subtle facial movements and color changes resulting from blood flow and muscle contractions. The approach comprises two major components: an Encoder for analyzing image features and a regression layer for evaluating Blood Volume Pulse. By incorporating both features simultaneously our methodology delivers more accurate results even in computing environments with limited resources. The proposed approach is expected to offer a more efficient way to monitor heart rate without invasive technology, particularly well-suited for mobile devices.

Construction and Performance Evaluation of Digital Radiographic System (이동형 디지털 X선 촬영장치의 구축 및 성능평가)

  • Cho, Hyo-Min;Nam, So-Ra;Lee, Chang-Lae;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.144-148
    • /
    • 2007
  • Current digital radiography systems are rapidly glowing in clinical applications. The purpose of this study was to evaluate the characteristics of a mobile digital radiographic system. The performance of the mobile DR system was evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on a LISTEM Mobix-1000 generator and a Teleoptic PRA Alpha-R4000 detector. Imaging characteristics were measured for these two systems using the IEC-61267 defined RQA5 (kVp: 74, additional filtration: 21 mmAl) radiographic condition. The MTF at 10% was measured as 2.4 cycles/mm and the DQE(0) values for radiation exposure 0.19, 0.5, and 1.3 mR were measured as 54%, 55%, and 76%, respectively. The NPS curves gradually decreased at high spatial frequencies. This high DQE at low frequencies, may be useful for low frequency information. The results suggested that mobile DR system could be integrated with emergency ambulance system in teleradiologic imaging applications.

  • PDF

Medical Information Dynamic Access System in Smart Mobile Environments (스마트 모바일 환경에서 의료정보 동적접근 시스템)

  • Jeong, Chang Won;Kim, Woo Hong;Yoon, Kwon Ha;Joo, Su Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the environment of a hospital information system is a trend to combine various SMART technologies. Accordingly, various smart devices, such as a smart phone, Tablet PC is utilized in the medical information system. Also, these environments consist of various applications executing on heterogeneous sensors, devices, systems and networks. In these hospital information system environment, applying a security service by traditional access control method cause a problems. Most of the existing security system uses the access control list structure. It is only permitted access defined by an access control matrix such as client name, service object method name. The major problem with the static approach cannot quickly adapt to changed situations. Hence, we needs to new security mechanisms which provides more flexible and can be easily adapted to various environments with very different security requirements. In addition, for addressing the changing of service medical treatment of the patient, the researching is needed. In this paper, we suggest a dynamic approach to medical information systems in smart mobile environments. We focus on how to access medical information systems according to dynamic access control methods based on the existence of the hospital's information system environments. The physical environments consist of a mobile x-ray imaging devices, dedicated mobile/general smart devices, PACS, EMR server and authorization server. The software environment was developed based on the .Net Framework for synchronization and monitoring services based on mobile X-ray imaging equipment Windows7 OS. And dedicated a smart device application, we implemented a dynamic access services through JSP and Java SDK is based on the Android OS. PACS and mobile X-ray image devices in hospital, medical information between the dedicated smart devices are based on the DICOM medical image standard information. In addition, EMR information is based on H7. In order to providing dynamic access control service, we classify the context of the patients according to conditions of bio-information such as oxygen saturation, heart rate, BP and body temperature etc. It shows event trace diagrams which divided into two parts like general situation, emergency situation. And, we designed the dynamic approach of the medical care information by authentication method. The authentication Information are contained ID/PWD, the roles, position and working hours, emergency certification codes for emergency patients. General situations of dynamic access control method may have access to medical information by the value of the authentication information. In the case of an emergency, was to have access to medical information by an emergency code, without the authentication information. And, we constructed the medical information integration database scheme that is consist medical information, patient, medical staff and medical image information according to medical information standards.y Finally, we show the usefulness of the dynamic access application service based on the smart devices for execution results of the proposed system according to patient contexts such as general and emergency situation. Especially, the proposed systems are providing effective medical information services with smart devices in emergency situation by dynamic access control methods. As results, we expect the proposed systems to be useful for u-hospital information systems and services.

A Portable Wireless EEG System for Neurofeedback: Design and Implementation

  • Chen, Hai-Feng;Ye, Dong-Hee;Kang, Young-Ho;Lee, Jung-Tae
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.461-470
    • /
    • 2007
  • Human can learn how to shape their brain electrical activity in a desired direction through continuous feedback of the electroencephalogram (EEG), and this technique is known as Neurofeedback (or EEG biofeedback), which has been used since the late 1960s in clinical applications. In this study, a portable wireless EEG (named wEEG) has been designed and implemented, which consists of a mobile station (a wireless two-channel EEG acquisition device) and a base station (a bridge between mobile station and computer). Moreover, a SensoriMotor Rhythm (SMR) training system was also implemented with the wEEG for enhancing attention with virtual environment. Experiment results based on 16 volunteers' (8 females and 8 males, average age is $27{\pm}4$) were reported in this paper. The results show that the SMR ratio of 87.5% subjects increased about 0.7% in training status than that in the stable status. With the proposed system, many training protocol scan be designed easily and can be done at home in our daily life conveniently. Additionally, the proposed system will be useful for disabled and aged people.

UI/UX Design for Development of Chronic Disease Chatbot (만성질환 챗봇 개발을 위한 UI/UX 디자인)

  • Jang, Jae-Hong;Kim, Sung-Hee;Jung, Deok-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.271-274
    • /
    • 2018
  • More than 80% of the deaths in Korea are due to chronic diseases. Mobile applications continue to emerge where IT companies and medical hospitals work together to manage chronic diseases. In recent years, the development of artificial intelligence chatbot has been under way to improve the efficiency and convenience of management. Since the chatbot process the conversation by a dialogue, users who are familiar with the GUI-based environment may not be familiar with accessibility or usage. In this paper, we analyze UI / UX of the mobile application that manages diabetes in chronic diseases, and present the UI / UX design of chatbot through this result.

  • PDF

THz Short-range Transmission Technology Based on Photonics (포토닉스 기반 THz 근거리 전송 기술)

  • Cho, Seung-Hyun;Moon, Sang-RoK;Lee, Joon Ki
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.6
    • /
    • pp.61-70
    • /
    • 2019
  • Recently, research and development for next-generation mobile communication and short-range wireless communication has begun worldwide along with the provision of commercial services of 5G mobile communication technology. In response to this trend, the THz band has attracted considerable attention as a frequency band for transmitting 100 Gbps of large-capacity wireless data. For communication in the THz band, research and development of approaches based on photonics and electronics is being actively performed; the configurations, characteristics, and performances of these two methods for THz transmission have been seriously examined. Among them, we reviewed the technical issues in implementing THz wireless transmission technology using photonics technology. We also introduced the Electronic and Telecommunications Research Institute's (ETRI) development of photonics-based THz short-range transmission technology starting from 2019 and including some initial results. In the near future, 100 Gbps high-capacity wireless data transmission technology utilizing photonics technology is expected to be commercially available and applied to various applications, such as 3D hologram transmission, uncompressed large capacity medical data transmission, and multiple augmented reality/virtual reality (AR/VR).