• Title/Summary/Keyword: mix ratio

Search Result 806, Processing Time 0.025 seconds

Bond Strength of Mortar mixed Activated Hwangtoh

  • Go, Seong-Seok;Yeo, Sang-Ku;Lee, Hyun-Chul
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.5
    • /
    • pp.468-477
    • /
    • 2012
  • This study aimed to mix and test mortar incorporating activated Hwangtoh to improve the Hwangtoh brick bond strength of brick structures. To do this, the bond strength correlation of mortar was analyzed by means of materials and experiment factors and levels, and the optimum conditions were suggested after analyzing the physical properties of brick and the mix ratio of mortar and additive. Furthermore, the compressive strength and bond strength were found to be in inverse proportion, and in terms of the materials and mixing level, W/C ratio, substitution ratio of activated Hwangtoh, and fine aggregate grading were shown to have a considerable influence on the strength. In conclusion, the optimum mixing conditions to improve the bond strength are found to set W/C ratio at 65% and replacmenet ratio of activated Hwangtoh at 10%.

An Experimental Study on the Improvement of Durability for the Foundation Concrete under Cold Weather Condition (혹한지역 기초 콘크리트의 내구성 향상을 위한 실험 연구)

  • 우상균;송영철;김경민;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.645-650
    • /
    • 2003
  • The purpose of this study is to provide the optimum mix design of cold weather concrete to be placed at the foundation structures in substation. The basic performance tests including slump and slump flow, air content, compressive strength and freezing & thawing resistance were conducted for cold weather concrete by varying with W/C ratios such as 40%, 50% and 60% and air contents such as 3%, 4%, 5% and 6%. The effect on durability of concrete corresponding to the increasing amount of air content and W/C ratio was evaluated and the optimum mix design was recommended. From this study, the concrete mix design containing 6% of air content and 45% of W/C ratio is recommended for the foundation concrete of substation.

  • PDF

Determinants of Registered Nurse Skill Mix & Staffing Level in Korea (간호인력 구성 및 확보수준 결정 요인)

  • Cho, Su-Jin;Kim, Jinhyun
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.20 no.1
    • /
    • pp.10-21
    • /
    • 2014
  • Purpose: This study was done to identify determinants of registered nurse (RN) skill mix and staffing level focused on hospital characteristics. Methods: Data were obtained from health insurance claims data and hospital reporting system in the Health Insurance Review and Assessment Service (HIRA) for the year 2010. Data from 2,998 hospitals were analysed using t-test, ANOVA, Pearson correlation, and regression analysis. Results: The RN skill mix and staffing level were positively related to hospital size and the percentage of inpatients to total patients. RN skill mix and staffing level were statistically different across regions. Including nursing aides (NA), however, there was no difference in staffing levels across regions. Medically vulnerable regions, bed operation rate, and the number of patients per doctor were also related to RN skill mix and staffing level. Conclusion: The statically significant determinants of RN skill mix and staffing level included hospital size, region, bed operation rate, percentage of inpatients, doctor-patient ratio. Further study needs to be done to investigate factors including RN supply and wages.

A Study on the Factors Affecting the High Fluid Mortar Containing Ground Granulated Blast-furnace Slag (고로슬래그 미분말을 함유한 고유동 모르터의 유동성상에 미치는 영향 요인에 관한 연구)

  • Kim, Jae-Hun;Yoon, Sang-Chun;Jee, Nam-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.4
    • /
    • pp.145-152
    • /
    • 2002
  • High fluid concrete unlike OPC concrete is made with various material, and the phase of fresh concrete is considerably different. In order to understand fluidity phase and mix properties of high fluid concrete, concrete is required to access as suspension structure which consists of aggregate and paste. The focus of this paper is to analyze the test results and quantify the effect of mix proportions of mortar and fineness modulus of sand on the properties of fresh mortar. The effect of water-binder ratio. sand-binder ration. contents of ggbs (by mass of total cementitious materials). and various contents of water reducing agent on the yield stress and plastic viscosity of the mix is studied. Based on the experimental results, the fellowing conclusions can be drawn: (1) The mixing time needed for high fluid mortar was approximately two times more than that of ordinary portland mortar. (2) The fluidity phase of mortar could be explained by yield stress of mix and the fluidity of mortar. (3) As the content of ggbs increased, yield stress of mortar was decreased and plastic viscosity of it was increased. (4) For the high fluid mortar, it was appeared that sand-binder ratio should be below 1.5.

A Study on Particle Size with Polymerization Factor in Dispersion Copolymerization of Styrene/n-Butylmethacrylate and Alumina (스티렌/노말 부틸 메타크릴레이트와 알루미나의 분산 공중합에서 중합인자에 따른 입경변화 연구)

  • Bang, Hyun-Su;Cho, Ur-Ryong
    • Elastomers and Composites
    • /
    • v.43 no.4
    • /
    • pp.230-240
    • /
    • 2008
  • In order to synthesize polymer particle containing inorganic material, styrene and nbutylmetacrylate were copolymerized with alumina by dispersion polymerization. The ratio in weight of styrene to n-butyl methacrylate was 3:1. Poly(N-vinyl pyrrolidon) and 2,2'-azobis(isobutyronitrile) were added as stabilizer and as initiator, respectively. The change of particle size was investigated with concentration of initiator, the type of medium, the mixed solubility parameter (${\delta}_{mix}$) of medium, and coupling agent. The enhancement in concentration of initiator resulted in slight increase of particle size. The increase of polarizability in medium also yielded the increase of particle size. In case of changing the ratio of isopropanol to distilled water, we could find relationship of $[{\delta}_{mix}]^{-4.01}\;{\propto}$ particle size and $[{\delta}_{mix}]^{-0.83}\;{\propto}$ particle size distribution(PSD). The type and the concentration of coupling agent showed no effect on the particle size and PSD.

Properties of the high strength and self-compacting concrete according to the replacement ratio of fly ash (플라이애쉬의 치환율에 따른 고강도 자기충전 콘크리트의 특성)

  • Kwon, Yeong-Ho;Lee, Hyun-Ho;Lee, Hwa-Jin;Ha, Jae-Dam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.85-88
    • /
    • 2006
  • This study describes the optimum mix proportion of the high strength and self-compacting concrete placed in main structures of LNG above tank. This concrete requires high strength level about $60{\sim}80MPa$, low hydration heat, balance between workability and consistency without vibrating in the actual work. For this purpose, low heat portland cement and fly ash are selected and design factors including water-binder ratio, replacement ratio of fly ash are tested. As experimental results, low heat portland cement shows lower the confined water ratio than another cement type and the optimum replacement ratio of fly ash in order to improve properties of the binder-paste shows 10% by cement weight considering test results of the confined water ratio$({\beta}p)$. Also, flowability of the high strength and self-compacting concrete by using fly ash about $10{\sim}20%$ is improved. The replacement ratio of fly ash 10% and water-binder ratio $25{\sim}27%$ are suitable to the design strength 80MPa and cost, In case of the design strength 60MPa, the replacement ratio of fly ash and water-binder ratio show 20% and $25{\sim}30%$ separately. Based on the results of this study, the optimum mix proportions of the high strength and self-compacting concrete will be applied to the construction of LNG above tank as a new type.

  • PDF

A Study on the Remicon B/P Application and Properties of High Strength Concrete using Crushed Sand (부순모래를 사용한 고강도콘크리트의 특성 및 레미콘 B/P 적용에 관한 연구)

  • Choi, Se-Jin;Lee, Seong-Yeon;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.57-62
    • /
    • 2007
  • Generally, the strength of concrete depends on factors of materials, mix proportions, compaction, manufacturing methods and curing and so on. And recently, it has increased the using of crushed sand for concrete due to the exhaustion of good natural aggregate. In case of Korea, in 2004, the using ratio of crushed sand occupies about 28% of whole fine aggregate. This is an experimental study to compare and analyze the influence of W/B ratio and replacement ratio of crushed sand on the fluidity and compressive strength of high strength concrete. For this purpose, the mix proportions of concrete according to the W/B (31.5, 27.5, 23.5%) and replacement ratio of crushed sand (0, 20, 40%) was selected. And then air content, slump-flow, a-lot, compressive strength test were performed.

An Experimental Study for Crack Prevention of Floor Mortar (바닥용 모르타르의 균열방지를 위한 실험적 연구)

  • 정재동;김진근;최응규;이칠성;이상순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.202-207
    • /
    • 1996
  • Recently, the mortar crack on floor is very serious in construction field, e.g. the crack due to plastic shrinkage and the crack due to drying shrinkage. To prevent this kind of crack, optimum mix propertions not only satisfying the required workability but also minimizing the unit water content were selected. And the expansion admixtures were used to compensate the shrinkage of mortar. This study shows that water/cement ratio used in construction field is about 64%. Even if we reduce water/cement ratio of mortar by the appropriate use the fine aggregate with high fineness modulus and superplastizer, floor mortar can have the required workability. The equations between mortar flow and water/cement ratio, sand/cement ratio, fineness modulus of fine aggregate were proposed in this study. And this equation may provide available mix proportions of floor mortar.

  • PDF

The Properties of the Super Flowing Concrete using manufactured sand (부순모래를 사용한 초류동 콘크리트의 배합특성)

  • 권영호;이상수;안재현;박칠림
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.83-88
    • /
    • 1997
  • In this paper, we described the basic elements (relative flowing area ratio and funeling velocity ratio in mortar, flowability and self-compactibility in concrete, and etc.) required for the maximum mix design of the super flowing concrete (SFC) using manufactured sand. Also, manufactured sand and fly ash were used for investigating characteristics of SFC through various experiments (replacement ratio of manufactured sand, optimum mix condition) before producing the concrete in batch plant. As the result of this project, the SFC using manufactured sand up to 50% showed high flowability and self-compactibility in fresh concrete. Furthermore, its compressive strength is higher than normal concrete without manufactured sand. From now on, this study may suggest how to apply manufactured sand in the SFC.

  • PDF

A Study on the Fluidity and Compressive Strength of HPC according to the Replacement Ratio of Crushed Sand (부순모래 대체율에 따른 고강도콘크리트의 유동특성 및 강도특성에 관한 연구)

  • Choi, Se-Jin;Kang, Won-Seok;Park, Chang-Soo;Lee, Seong-Yeon;Lee, Sang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.437-440
    • /
    • 2006
  • Generally, the strength of concrete depends on factors of materials, mix proportions, compaction, manufacturing methods and curing and so on. And recently, it has increased the using of crushed sand for concrete due to the exhaustion of good natural aggregate. This is an experimental study to compare and analyze the fluidity and compressive strength of ultra-high strength concrete according to the replacement ratio of crushed sand. For this purpose, the mix proportions of concrete according to the W/B ratio and replacement ratio of crushed sand was selected. And then air content, slump-flow, O-lot, compressive strength test were performed.

  • PDF