• 제목/요약/키워드: minimum flow

검색결과 1,099건 처리시간 0.03초

고온 평판의 분무냉각에 있어서 MHF점에 관한 연구 (Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate)

  • 김영찬
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.974-981
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about$ 900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

SMEMAX변환에 의한 온수빈도분석에 관한 연구 (A Study on the Minimum Flow Frequency Analysis by SMEMAX Transformation)

  • 이순혁;박명근
    • 한국농공학회지
    • /
    • 제29권3호
    • /
    • pp.138-144
    • /
    • 1987
  • This study was conducted to pursue the normalization of frequency distribution by making approach the coefficient of skewness to nearly zero tbrough SMEMAX transformation and to get probable minimum flows can be acquired by means of transforrnation equation which has been derivated by SMEMAX method to the annual minimum flow series of five watersheds along Geum river basin. The results obtained through SMEMAX method were compared with probable minimum flows according to return periods by Type III extremal distribution which has been determined as the best fitted one among probablility distributions for the analysis of minimum flow. All the results obtained through this study are summarized as follows. 1.SMEMAX transformation based on median value was proved to be the best method when the coefficient of skewness has less reliability because of the short duration for the observation and were not affected by accidental outliers. 2.SMEMAX transformation has found to be the best one for the coefficient of skewness to be made nearly zero in comparison with log and cubic root transformation. 3.Probable minimum flows according to the return periods were derivated by transformation equations obtained through theoretical analysis of SMEM AX transformation. 4.In general, probable minimum flows by SMEMAX method were appeared as higher values in the range of five and twenty years and as lower ones in the range of below than five and more than fifty years in return periods respectively, in comparison with the results of type III extremal distribution. 5.Relative errors in the probable minimum flows of SMEMAX method to the results of type III extremal distribution were shown to be within ten percent except those of one hundred years in return periods. 6.SMEMAX method was also confirmed to be useful for the analysis of minimum flow frequency as well as flood frequency analysis.

  • PDF

오수관 설계유량 산정법이 설계유속에 미치는 영향 (Design Flow Velocity Changes According to the Design Flow Determination Methods in the Sanitary Sewer)

  • 현인환;원승현;김형준;이제인
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.749-757
    • /
    • 2005
  • The present study analyzed actual cases of designed flow estimation method and designed flow rate of sewage pipe lines. In order to examine the effects of peak-hour demand factor estimation with given daily highest peak loading, we analyzed its effects on designed flow rate with changing the peak-hour demand factor from 2.0 to 10.0. The results of this study are as follows. When reviewing the recent designs, we found that 59.4% of pipe line with 250mm and 300mm diameter, which fall under minimum allowable pipeline did not meet the minimum velocity which is specified as 0.6m/sec in design standards. The pipe line that have minimal access population or have very low slope did not satisfy the minimum velocity. In estimating the designed sewage flow, the applied daily highest peak loading and hourly highest peaking loading were the load factor for the entire population of the planned area, and for the peak loading of the initial pipes connected to a very small population, we applied the same factor as that applied to the entire area and, as a result, the hourly highest flow was underestimated. Because, in case of the initial pipes, the method of applying the same peak loading to all subject areas is highly possible to produce underestimated design flow, when estimating the designed flow of the initial pipes connected to a small population need to adopt a rational flow factor according to the size of population. For this, it is considered to investigate and analyze raw data on daily and hourly variation of sewage flow.

하천의 경관 유지 수량의 결정 (Determination of the Minimum Instream Flows for the Landscape of Riverside)

  • 홍형순;이주헌;정상만
    • 한국조경학회지
    • /
    • 제30권6호
    • /
    • pp.17-25
    • /
    • 2003
  • The physical components of a river, such as water surface width/river width ratio, water level, and flow velocity vary according to different flowrates. Moreover, the riverside landscapes are greatly affected by the change of physical components of the stream or river. This paper provides an analysis of the influence of changing physical components of a river on the riverside landscape using a survey-based quantification method. The questionnaire was developed based on current literature, and was submitted to 326 people who each visited a representative station along the riverside.This survey was implemented three times at each representative station during periods of different flowrates. The results of this analysis and survey have Produced an understanding of the relationship between the variation of physical components and riverside landscapes. Survey results about the flow comparison are summarized as follows. Viewing riverside landscapes, most respondents are sensitive to the change of the flow velocity and prefer high water levels to low water levels. As a whole, respondents prefer abundant stream flows and moderate flow velocity in which they can perceive the flow of water. The minimum instream flows for riverside landscapes is estimated at each representative station by using a survey-based quantification method, and the estimated results of some representative stations were greater than the mean monthly flow at each station. The result of this analysis shows that establishing minimum instream flows for riverside landscapes is not only a technical problem, but also a legal problem. Therefore, in the to establish the instream flows in a river, the estimated results have to be considered as a relative standard. Regarding the survey results, respondents' satisfaction level didn't show any clear inclination according to the variation of various hydraulic properties. In determining the minimum instream flow using such an inquiry method, the structure of riverside scenery may vary according to the change of seasons or months. Therefore, to determine a consistent general inclination about the flow rate, it is necessary to have more detailed flow rates for each season or month combined with more inquiries.

스윙형 역지 밸브의 열림 특성에 관한 실험적 연구 (Experimental Study on the Opening Characteristics for Swing Check Valves)

  • 송석윤;김양석;박성근;홍승열
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.555-561
    • /
    • 2003
  • The experimental apparatus is designed and installed to measure the disc positions with flow velocity, $V_{open}\;and\;V_{min}$ for 3 inch and 6 inch swing check valves. The minimum flow velocity necessary to just open the disc at a full open position is referred to as $V_{open}\;and\;V_{min}$ is defined as the minimum velocity to fully open the disc and hold it without motion. In the experiments, $V_{min}$ is determined as the minimum flow velocity at which the back stop load begins to increase after the disc is idly opened or the oscillation level of disc is reduced below $1^{\circ}$. The results show that the $V_{min}$ velocities for 3 inch and 6 inch swing check valves are about 15.6% and 4.8% higher than the $V_{open}$ velocities, respectively. Although the experiments were done with the stable uniform flow, additional experiments will be performed to determine the effects of the upstream disturbances.

  • PDF

경사면상의 층류 세류유동 특성 (Flow Characteristics of a Laminar Rivulet Down an Inclined Surface)

  • 김병주
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1035-1042
    • /
    • 2005
  • In the present study, the principle of minimum energy is employed to configure the shape of rivulet flowing down an inclined surface. The profile of laminar rivulet is determined by numerical integration. The maximum center thickness, which corresponds to the minimum thickness of falling film, is found to exist regardless of liquid flow rate and is compared with the analytical and experimental data. At small liquid flow rate the center thickness of rivulet and its width increase almost linearly with flow rate. Once the center thickness of rivulet becomes very close to its maximum value, its growth rate retards abruptly. However the width of rivulet increases proportionally to the liquid flow rate and most part of its free surface is as flat as that of stable film. The growth rate of rivulet thickness with respect to liquid flow rate becomes larger at bigger contact angle. The width of rivulet increases rapidly with its flow rate especially at small contact angle, As the liquid-vapor interfacial shear stress increases, the center thickness of rivulet decreases with its flow rate, which is remarkable at small contact angle. However the effect of interfacial shear stress on the width of rivulet is almost negligible.

단지계획지구 홍수저류지의 하천유지유량 공급방안 연구 (A Feasibility Study on Supplying Stream Minimum Flow Using Detention Storage in Developing Planned District)

  • 노재경;박현구
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1219-1223
    • /
    • 2005
  • This study was accomplished to confirm the possibility of supplying stream minimum flow from detention storage which was determined to reduce peak flows of flood within developing planned district. The results analyzed was summarized as follows; Firstly, Sin-gil district situated in Ansan city was selected, of which watershed area has $0.56km^2$. And detention storage was determined to $5,370m^3$ from analyzing flood volume by the SCS unit hydrograph method. Secondly, using Visual Basic ver 6.0, a detention storage water balance model was developed, in which simulation was based on conditioning storage inflow and outflow according to streamflow volume or rate state. And streamflow was simulated using the DAWAST model. Thirdly, detention operation scenarios were consisted of the combinations with inflow referencing streamflow of 5mm/day, 10mm/day and outflow referencing streamflow of 1mm/day, 2mm/day. The developed detention storage water balance model was operated to simulate daily water storages of detention sized on flood by scenarios. Stream minimum flows were able to be supplied during 209 days to 237 days per a year, total volume of stream minimum flows supplied for this period was analyzed to reach 27 to $55\% of yearly streamflow volume. If inflow criteria of streamflows to detention was considered to be established on a theoretical condition, it is expected to supply stream minimum flows of 20 to $30\% of yearly streamflow from stream to detention. Also to maximize function of supplying urban stream minimum flow from detention storages, sewage waters within developing planned district have to be treated and entered to detention inflow together with streamflows to enrich function of detention planned to reduce flood volumes.

  • PDF

A Framework for Determining Minimum Load Shedding for Restoring Solvability Using Outage Parameterization

  • Hwachang Song;Lee, Byongjun
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권2호
    • /
    • pp.73-78
    • /
    • 2004
  • This paper proposes a framework for determining the minimum load shedding for restoring solvability. The framework includes a continuation power flow (CPF) and an optimal power flow (OPF). The CPF parameterizes a specified outage from a set of multiple contingencies causing unsolvable cases, and it traces the path of solutions with respect to the parameter variation. At the nose point of the path, sensitivity analysis is performed in order to achieve the most effective control location for load shedding. Using the control location information, the OPF for locating the minimum load shedding is executed in order to restore power flow solvability. It is highlighted that the framework systematically determines control locations and the proper amount of load shedding. In a numerical simulation, an illustrative example of the proposed framework is shown by applying it to the New England 39 bus system.

스윙형 역지밸브의 고장 원인 분석과 열림 특성에 관한 실험적 연구 (Analyses of Failure Causes and an Experimental Study on the Opening Characteristics of Swing Check Valves)

  • 송석윤;유성연
    • 한국유체기계학회 논문집
    • /
    • 제8권6호
    • /
    • pp.15-25
    • /
    • 2005
  • Check valves playa vital role in the operation and protection of nuclear power plants. Check valves failure in nuclear power plants often lead to a plant transient or trip. The analysis of historical failure data gives information on the populations of various types of check valves, the systems they are installed in, failure modes, effects, methods of detection, and the mechanisms of the failures. A majority of check valve failures are caused by improper application. The experimental apparatus is designed and installed to measure the disc positions with flow velocity, Vopen and Vmin for 3 inch and 6 inch swing check valves. The minimum flow velocity necessary to just open the disc at a full open position is referred to as Vopen, and Vmin is defined as the minimum velocity to fully open the disc and hold it without motion. In the experiments, Vmin is determined as the minimum flow velocity at which the back stop load begins to increase after the disc is fully opened or the oscillation level of disc is reduced below $1^{\circ}$. The results show that the Vmin velocities for 3 inch and 6 inch swing check valves are about 27.3% and 17.5% higher than the Vopen velocities, respectively.

Minimum detectable activity of plastic scintillator for in-situ beta measurement system in ground water

  • Choi, Woo Nyun;Lee, UkJae;Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1169-1175
    • /
    • 2019
  • The minimum detectable activity (MDA) value was derived according to the flow rate of the sample and degree of amplification of the device by sending the sample directly from the collection site to the detection part through a pump. This method can lead to reduction in time and cost compared to the existing measurement method that uses a pre-treatment process. In this study, experiments were conducted on $^3H$ and $^{90}Sr$, which are the major pure beta-emitting radionuclides, by setting the sample flow rate and the amplification gain as factors. The MDA values were derived according to the flow rates, considering that the flow rate can affect the MDA values. There were no change in the MDA under different flow rates of 0, 600, 800, and 1000 mL/min. Therefore, it was confirmed that the flow rate may not be considered when collecting samples for monitoring in actual field. As the degree of amplification of the amplifier increased, the time required to reach the target MDA decreased. When the amplification was quadrupled, the detection efficiency increased by approximately 23.4 times, and the time to reach the MDA decreased to approximately 1/550 times. This method offers the advantage of real-time on-site monitoring.