• Title/Summary/Keyword: microscopic system

Search Result 538, Processing Time 0.028 seconds

The design of microscopic system using zoom structure with a fixed magnification and the independency on the variation of object distance (줌 구조를 이용하여 물체거리가 변해도 상면과 배율이 고정되는 현미경 광학계의 설계)

  • 류재명;조재흥;임천석;정진호;전영세;이강배
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.6
    • /
    • pp.613-622
    • /
    • 2003
  • The multi-configurative microscopic system for inspecting the wire-bonding of reed frame is designed. Rays refracted by objective lens group which is composed of common lens group of x2 and x6 are splitted by beam-splitter, and Rays through the central region and the boundary region of the object imaged at x2 and x6 through imaging lens groups, respectively. The depth of wire structure on the reed frame has about $\pm$3 mm, in order to observe by uniform magnification without the dependency on the variation of objective distance generated by the depth of wire structure on the reed frame, imaging lens groups should be moved on nonlinear locus like mechanically compensated zoom lenses. The nonlinear equations for zoom locus are derived by using the Gaussian bracket. Refraction powers and positions of each groups are numerically determined by solving the equations, and initial design data for each groups is obtained by using Seidel third order aberration theory. The optimization technique is finally utilized to obtain this microscopic system.

Efficient Tomography System of Electron Microscopy using Selective Filtering (선택적 Filtering을 이용한 효율적 전자현미경 Electron Tomography 시스템)

  • Jung, Won-Goo;Cho, Hye-Jin;Park, Seong Oak;Chae, Hee-Su;Je, A-Reum;Lee, Kyoung Hwan;Jung, Hyun Suk;Kweon, Hee-Seok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.395-396
    • /
    • 2009
  • Electron tomography를 이용한 3차원적 영상 시각화는 electron microscopy를 통해 하나의 실험 대상으로부터 연속된 이미지를 생산함으로써 이루어진다. 이미지 데이터 내부에는 대용량의 정보값을 포함하고 있어 3차원 구조물로의 변환이 가능하다. electron tomography 작업 과정 중 고해상도 원본 이미지에 pattern recognition 알고리즘이 적용된 필터링을 적용하면 실험에 필요한 데이터의 정보 손실을 최소화한 상태에서 electron tomography 시스템의 효율성을 높일 수 있다. 또한 tomographic econstruction이 진행되는 각 단계에 hanning windowing을 적용하면 불필요한 정보 값이나 노이즈 등을 효과적으로 제거할 수 있다. 윤곽선 데이터의 효과적 활용을 위하여 sobel 필터 처리를 할 경우 관찰하고자 하는 대상의 윤곽선 특징을 뚜렷하게 시각화 할 수 있었다. 본 연구를 통하여 데이터의 시각화 과정에서 실험의 신뢰성 확보를 위해 원본 이미지를 기반으로 하는 tomogram과 필터링을 적용한 tomogram을 비교하여 최종 결과물의 정확도를 높이고, electron tomography를 통한 결과물의 질적 향상을 유도할 수 있음을 확인하였다.

The Performance of DS/SSMA BPSK Communication with Microscopic and Macroscopic Diversity in Mobile Radio Channel (이동 무선채널에서 마이크로소코픽과 매크로스코픽 다이버시티를 사용한 DS/SSMA BPSK 통신 의 성능 분석)

  • 강병권;김기전;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.1
    • /
    • pp.100-109
    • /
    • 1993
  • In this paper, the performance of DS /SSMA BPSK communication system with maximal ratio combining microscopic diversity and selection macroscopic diversity is analyzed. The effects of Rayleigh fading and log normal shadowing on system performance are analyzed, and the validity of microscopic and macroscopic diversity to mitigate the two fading effects are estimated. The increase of the number of chips is effective for mitigating log norma; shadowing, while the increase of the order of microscopic diversity is not. And the higher the standard deviation of shadowing, the more effective the macroscopic diversity.

  • PDF

Marco and Microscopic Observations of Fatigue Crack Growth in Friction Stir Welded 7075-T651 Aluminum Alloy Plates (마찰교반용접된 7075-T651 알루미늄 판재의 피로균열전파의 거시적 및 미시적 관찰)

  • Kong, Yu-Sik;Kim, Seon-Jin
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.62-69
    • /
    • 2014
  • In this paper, in order to investigate the effects of marco and microscopic observations of fatigue crack growth in friction stir welded (FSWed) 7075-T651 aluminum alloy plates, fatigue crack growth tests were performed under constant amplitude loading condition at room temperature with three different pre-cack locations, namely base metal (BM-CL) and two kinds of pre-crack locations in welded joints, weld metal (WM-CL) and heat affected zone (HAZ-CL) specimens. The fatigue crack growth behavior of FSWed 7075-T651 aluminum alloy plates were discussed based on the marco and microscopic fractographic observations. The marcoscopic aspects of surface crack growth path for BM-CL and HAZ-CL specimens indicate relatively straight lines, however, the crack growth paths of WM-CL specimens grow first straight and by followed toward the TMAZ and HAZ. The microscopic aspects of fatigue fracture for BM-CL and HAZ-CL specimens indicate typical fatigue striation, but WM-CL showed intergranular fracture pattern by micro structural changes of FSW process.

AN INTELLIGENT TRANSPORT MANAGEMENT SYSTEM FOCUSED ON MICROSCOPIC TRAFFIC SIGNAL CONTROL

  • Nazmi, Mohd;Takaba, Sadao
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.77-82
    • /
    • 2001
  • An intelligent road transport management system focused on microscopic, real-time traffic signal control is proposed. Referring to the development of those systems in Japan, extensive use of image traffic detectors observing the movement of vehicles inside intersections, and direct data exchange between the signal controllers of neighboring intersections are newly assumed. On site investigation of five intersections in Japan or in Malaysia shows the possibility of effective information provision and simple algorithm for solving heavy congestion, as well as easy installation.

  • PDF

Development of Highly Accurate Inspection System for Cylindrical Aluminum Casts with Microscopic Defects

  • Shinji, Ohyama;Hong, Keum-Shik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.35.3-35
    • /
    • 2001
  • Developed is an optical auto-inspection system to detect some microscopic defects on the Inside surface of the hydraulic automobile brakes at the production line. A small cylindrical detection module with a solid laser source at its center has two rings of optical fibers to separately collect light reflected and scattered from the defects on the surface. The cylindrical brake part rotates with respect to the detection module that will move parallel to the rotational axis of the cylinder. Thus, the optical module can scan the whole inside surface area. The automatic detection of the defects is to compare the intensity distributions ...

  • PDF

Tolerance analysis of Multi-Configurative Microscopic System for Inspecting the Wire-Bonding Status of Semiconductor Chips (반도체 와이어 본딩 검사용 다중배치 현미경 광학계에 대한 공차분석)

  • Ryu, Jae-Myung;Kim, Jae-Bum;Kang, Geon-Mo;Jung, Jin-Ho;Baek, Seung-Sun;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.149-158
    • /
    • 2006
  • We have analyzed various tolerances of the multi-configurative microscopic system for inspecting the wire-bonding of a reed frame by using the Gaussian bracket method and the equivalent lens method. The tolerances for the curvature and the thickness, which are axial symmetric tolerances, are given by varying the back focal length within a fecal depth under diffraction-limited conditions. Moreover, by using the trial and error method, the axial non-symmetric tolerances for decenter and tilt are established by assigning the 5% variation of MTF(modulation transfer function) at the spatial frequency of 50 lp/mm and at the field angle of 0.7 field. As the tolerances with the most probable distribution are distributed within the range of the decay rate of less than 5% independent of the probability distribution of tolerances, we can achieve completely the desired design performances of the multi-configurative microscopic system by using the various ranges of these tolerances.

Development of Remote Data Analysis System for the Joint Use of Equipments (분석기기지원을 위한 원격 데이터 분석 시스템 개발)

  • 최인식
    • Journal of Korea Technology Innovation Society
    • /
    • v.2 no.3
    • /
    • pp.94-106
    • /
    • 1999
  • In Korea Basic Science Institute(KBSI) the remote data analysis system is developed for the joint use of advanced equipments. This system enables the researchers to access the datas which are produced at KBSI and analyse them by Java program on the Web,. Except Web browser such as Internet Explorer or Netscape Navigator no additional softwares are required for analysing data. We have developed remote data analysis systems for five major equipments which KBSI supports for the researchers, The systems which are developed are those for NMR spectrometer High Reso-lution Tandem mass Spectrometer Microscopic Imaging System DNA Sequencer and Natural Ra-dioactivity Measruement System, These programs work on any computer platform and any operat-ing system only if the internet is available. This remote data analysis system will be served as a part of Collaboratory the remote collaborative system.

  • PDF

Study on the Optical Analysis Equipment Control System for Electronic Parts Inspection (전자 부품 검사용 광학분석 장비 제어시스템에 대한 연구)

  • Lee, Jun Ha
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.67-71
    • /
    • 2015
  • Product of technology developed in this study is an external interface for controlling the equipment of pendant key remote control system circuit board, and it is used in the electronic component test equipment system. Main control system module is in the role as a device for controlling the various control devices that make up the integrated system for microscopic examination at the request of the host computer engineers to control the inspection equipment. The pentane-key interface module to its role as a device for controlling the various control devices that make up the integrated system for microscopic examination at the request of the host computer for the engineer to control the inspection equipment. Development of the control system can be expected in the configuration of a system for efficient and accurate inspection of high-precision parts.

A Glance of Electron Tomography through 4th International Congress on Electron Tomography (International Congress on Electron Tomography에 대한 간략한 이해와 현황)

  • Rhyu, Im-Joo;Park, Seung-Nam
    • Applied Microscopy
    • /
    • v.38 no.3
    • /
    • pp.275-278
    • /
    • 2008
  • Electron tomography (ET) is an electron microscopic technique for obtaining a 3-D image from any electron microscopy specimen and its application in biomedical science has been increased thanks to development of electron microscopy and related technologies during the last decade. There are few researches on ET in Korea during this period. Although the importance of ET has been recognized recently by many researchers, initial approach to electron tomographic research is not easy for beginners. The 4th International Congress on Electron Tomography (4 ICET) was held on Nov $5{\sim}8$, 2006, at San Diego. The program dealt instrumentation, reconstruction algorithm, visualization/quantitative analysis and electron tomographic presentation of biological specimen and nano particles. 1 have summarized oral presentations and analyzed the posters presented on the meeting. Cryo-electron microscopic system was popular system for ET and followed conventional transmission electron microscopic system. Cultured cell line and tissue were most popular specimens analyzed and microorganisms including bacteria and virus also constituted important specimens. This analysis provides a current state of art in ET research and a guide line for practical application of ET and further research strategies.