• Title/Summary/Keyword: microscopic image

Search Result 198, Processing Time 0.026 seconds

Experiences of Ageism and "Self-Ageism" (노인차별 경험과 자기연령주의(self-ageism))

  • Kim, Juhyun;Oh, Hyein;Ju, Kyonghee
    • 한국노년학
    • /
    • v.40 no.4
    • /
    • pp.659-689
    • /
    • 2020
  • This study focuses on the process of internalizing the perception of negative discrimination among elderly people who have experienced age discrimination. The grounded theory method was used to identify the age discrimination experienced by the elderly in their daily lives and to explore the consequences of such discrimination through self-ageism. According to the analysis results, the elderly respond not only to explicit discrimination but also to implicit discrimination. In this process, the stronger the pain of old age (poverty, disease, ignorance, and solitude) and the stronger the memory of failing to respond to discrimination, the higher the level of self-ageism. "Self-ageism" has internalized the negative image of the elderly, who have been discriminated against by age, resulting in disadvantages in terms of quality of life through various reject/separate/suspension actions in reality. In the presence of supportive resources such as health, institutional support, and caregivers, the elderly have room to overcome self-ageism through more active ways. However elderly people who cannot motivate themselves and they lack these resources, elderly are trapped in negative reflux caused by self-ageism and sustained a depressed and shrinking life. In this state, it is not easy to motivate themselves and make physical, cognitive, emotional and social responses. Therefore, in this analysis, we specifically noted two aspects, contextual conditions and interventional conditions, and proposed programs for synchronizing senior citizens and improving resiliency from a microscopic point of view, and argued for the need to develop systems such as supplementing welfare and health service systems related to the entire life cycle, expanding accessibility and 'age-integration' through 'Community Care', awareness improvement and anti-discrimination laws.

A STUDY ON THE SHEAR BOND STRENGTH AND THE ANTICARIOGENICITY OF GLASS IONOMER CEMENT FOR BRACKET BONDING (브라켓 접착용 글라스 아이어노머 시멘트의 접착강도 및 항우식 효과에 관한 연구)

  • Kang, Yong-Joo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.538-553
    • /
    • 1999
  • The purpose of this study was to compare the shear bond strength and the anticariogenicity of glass ionomer cement with conventional bonding resin and fluoride releasing resin. After the shear bond strength test, scanning electron microscopic observation was performed for the evaluation of the fracture patterns in each group. Under the polarizing light microscope, artificially induced carious lesions were evaluated and the lesion depths of the samples were measured using image analyzing program(Image-Pro $PLUS^{TM}$, USA). 50 sound maxillary premolars were used for the bond strength test and another 30 for the anticariogenic test. Data collected were analyzed statistically using Oneway-ANOVA and Scheffe test. The results were as follows: 1. Glass ionomer groups(G-III, IV, V) generally showed the lower bond strength values than resin groups(G-I, II). 2. Among the two resin groups, G-I showed the higher bond strength than G-II without statistically significant difference between them(p>.05). 3. Within glass ionomer groups, statistical significance was found between G-III and G-V with the superior bond strength in G-V (p<.05). 4. Under the SEM, adhesive failure was the predominant fracture pattern in G-I and II, whereas cohesive failures were mainly observed in G-III. In G-IV and V, mixed type of pattern where the both fracture patterns coexisted within samples could be seen. 5. In evaluation of the depth of artificially developed carious lesion, glass ionomer group showed shallower depth than resin groups with statistical significance between G-III and G-I, II(p<.05). Among resin groups, fluoride releasing resin(G-II) showed the shallower depth than conventional resin(G-I)(p<.05).

  • PDF

A Study of the Effect of a Mixture of Hyaluronic Acid and Sodium Carboxymethyl Cellulose ($Guardix-sol^{(R)}$) on the Prevention of Pericardial Adhesion (Hyaluronic Acid와 Sodium Carboxymethyl Cellulose 혼합용액($Guardix-sol^{(R)}$)의 섬유막유착 방지 효과에 관한 연구)

  • Lee, Song-Am;Kim, Jin-Sik;Kim, Jun-Seok;Hwang, Jae-Joon;Lee, Woo-Surng;Kim, Yo-Han;Cho, Yang-Kyu;Chee, Hyun-Keun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.596-601
    • /
    • 2010
  • Background: This study was designed to evaluate the efficacy of a mixture of hyaluronic acid and sodium carboxymethyl cellulose ($Guardix-sol^{(R)}$) on experimental pericardial adhesion. Material and Method: Thirty rats were divided into 2 groups of 15 rats each and pericardial mesothelial injury was induced during surgery by abrasion. In the control group, blood and normal saline were administered into pericardium; in the test group, blood and HA-CMC solution were administered. Pericardial adhesions were evaluated at 2 weeks (n=5), 4 weeks (n=5), and 6 weeks (n=5) after surgery. The severity of adhesions was graded by macroscopic examination, and the adhesion tissue thickness was analyzed microscopically with Masson trichrome stain and an image processing program. Result: The test group had significantly lower macroscopic adhesion scores ($2.9{\pm}0.6$ : $3.9{\pm}0.4$, p<0.000) compared with the control group. For microscopic adhesion tissue thickness, the test group had lower scores compared with the control group, but this difference was not statistically significant ($91.73{\pm}49.91$ : $117.67{\pm}46.4$, p=0.106). Conclusion: We conclude that an HA-CMC solution ($Guardix-sol^{(R)}$) reduces the formation of pericardial adhesions in this animal model.

High Resolution MR Images from 3T Active-Shield Whole-Body MRI System (3T 능동차페형 전신 자기공명영상 장비로부터 얻어진 고해상도 자기공명영상)

  • Bo-Young Choe;Sei-Kwon Kang;Myoung-Ja Chu;Hyun-Man Baik;Euy-Neyng Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.138-148
    • /
    • 2001
  • Purpose : Within a clinically acceptable time frame, we obtained the high resolution MR images of the human brain, knee, foot and wrist from 3T whole-body MRI system which was equipped with the world first 37 active shield magnet. Materials and Methods : Spin echo (SE) and Fast Spin Echo (FSE) images were obtained from the human brain, knee, foot and wrist of normal subjects using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. For acquisition of MR images of knee, foot and wrist, we employed a homemade saddle shaped RF coil. Topical common acquisition parameters were as follows: matrix=$512{\times}512$, field of view (FOV) =20 cm, slice thickness = 3 mm, number of excitations (NEX)=1. For T1-weighted MR images, we used TR = 500 ms, TE = 10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE = 108 ms. Results : Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.5T system. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter. Conclusion The present results demonstrate that the MR images from 3T system could provide better diagnostic quali\ulcorner of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods.

  • PDF

Canine MR Images from 3T Active-Shield MRI System (3T 능동차폐형 자기공명영상 장비로부터 얻어진 개의 자기공명영상)

  • Choe, Bo-Young;Park, Chi-Bong;Kang, Sei-Kwon;Chu, Myoung-Ja;Kim, Euy-Neyng;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.113-124
    • /
    • 2001
  • For veterinary imaging diagnosis, we obtained MR images of the canine brain, spine, kidney and pelvis from 3T MRI system which was equipped with the world first 3T active shield magnet. Spin echo (SE) and fast Spin Echo (FSE) images were obtained from the canine brain, spine, kidney and pelvis of normal and sick dogs using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. In addition, we employed a homemade saddle shaped RF coil. Typical common acquisition parameters were as follows: matrix=512$\times$512, field of view (FOV)=20cm, slice thickness=3 w, number of excitations (NEX)=1. For T1-weighted MR images, we used TR=500 ms, TE=10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE=108 ms. Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.57 system. The high resolution images acquired in this study represent more than a 4-fold increase in in-plane resolution relative to conventional images obtained with a 20 cm field of view and a 5 mm slice thickness. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter The present results demonstrate that the MR images from 3T system could provide better diagnostic quality of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods. Moreover, MRI technique could begin to apply for veterinary medicine in Korea.

  • PDF

The fracture resistance of heat pressed ceramics with wire reinforcement (금속선 강화에 따른 열 가압 도재의 파절저항)

  • Jo, Deuk-Won;Dong, Jin-Keun;Oh, Sang-Chun;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Statement of problem: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. Purpose: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. Material and methods: Heat pressed ceramic(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire(Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens(width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine(Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope(JSM-6360, JEOL, Japan) under platinum coating. Results: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics(P<.001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. Conclusion: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.

3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT (방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학)

  • Kim, Ju-Heon;Han, Sung-Mi;Song, Hyun-Ouk;Seo, Youn-Kyung;Moon, Young-Suk;Kim, Hong-Tae
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.133-142
    • /
    • 2018
  • 3D histology is a imaging system for the 3D structural information of cells or tissues. The synchrotron radiation propagation phase contrast micro-CT has been used in 3D imaging methods. However, the simple phase contrast micro-CT did not give sufficient micro-structural information when the specimen contains soft elements, as is the case with many biomedical tissue samples. The purpose of this study is to develop a new technique to enhance the phase contrast effect for soft tissue imaging. Experiments were performed at the imaging beam lines of Pohang Accelerator Laboratory (PAL). The biomedical tissue samples under frozen state was mounted on a computer-controlled precision stage and rotated in $0.18^{\circ}$ increments through $180^{\circ}$. An X-ray shadow of a specimen was converted into a visual image on the surface of a CdWO4 scintillator that was magnified using a microscopic objective lens(X5 or X20) before being captured with a digital CCD camera. 3-dimensional volume images of the specimen were obtained by applying a filtered back-projection algorithm to the projection images using a software package OCTOPUS. Surface reconstruction and volume segmentation and rendering were performed were performed using Amira software. In this study, We found that synchrotron phase contrast imaging of frozen tissue samples has higher contrast power for soft tissue than that of non-frozen samples. In conclusion, synchrotron radiation propagation phase contrast cryo-microCT imaging offers a promising tool for non-destructive high resolution 3D histology.

Emulsifying Properties of Gelatinized Octenyl Succinic Anhydride Modified starch from Barley (호화 옥테닐 호박산 전분의 유화 특성)

  • Kim, San-Seong;Kim, Sun-Hyung;Lee, Eui-Seok;Lee, Ki-Teak;Hong, Soon-Taek
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.174-188
    • /
    • 2019
  • The present study was carried out to investigate the emulsifying properties of heat-treated octenyl succinic anhydride(OSA) starch and the interfacial structure at oil droplet surface in emulsions stabilized by heat-treated OSA starch. First, the aqueous suspensions of OSA starch were heated at $80^{\circ}C$ for 30 min. Oil-in-water emulsions were then prepared with the heat-treated OSA starch suspension as sole emulsifier and their physicochemical properties such as fat globule size, surface load, zeta-potential, dispersion stability, confocal laser scanning microscopic image(CLSM) were determined. It was found that fat globule size decreased as the concentration of OSA starch in emulsions increased, showing a lower limit value ($d_{32}:0.31{\mu}m$) at ${\geq}0.2wt%$. Surface load increased steadily with increasing OSA starch concentration in emulsions, possibly forming multiple layers. In addition, fat globule sizes were also influenced by pH: they were increased in acidic conditions and these results were interpreted in view of the change in zeta potentials. The dispersion stability by Turbiscan showed that it was more unstable in emulsions at acidic condition. Heat-treated OSA starch found to adsorb at the oil droplet surface as some forms of membrane (not starch granules), which might be indicative of stabilizing mechanism of OSA starch emulsions to be steric forces.