• 제목/요약/키워드: microfluidic

검색결과 433건 처리시간 0.028초

친수성 유지를 위해 Monomethyl Ether Hydroquinone이 제거된 2-Hydroxyethyle methacrylate로 처리하는 PDMS 표면개질 (PDMS Surface Modification for hydrophilicit Using 2-Hydroxyethyle Methacrylate without Monomethyl Ether Hydroquinone)

  • 김상철;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.36-38
    • /
    • 2003
  • In this paper, the surface modificatioin of PDMS (polydimethyl-siloxane) which is a useful material of microfluidic devices is presented. PDMS-based devices can be fabricated by casting the polymer in a mold, but the porosity and the hydrophobicity of PDMS make difficult to use as bio-medical devices. To overcome these disadvantages, the PDMS surface is grafted with HEMA (2-Hydroxyethyle methacrylate) treatments and $O_2$ plasma process. The $O_2$ plasma process is performed for 20 sec after curing PDMS, and PDMS is put in the prepared HEMA without Monomethyle Ether Hydroquinone. Residual monomers and homopolymers of HEMA-treated PDMS surface are removed using soxhlet extractor. The PDMS surface modification using HEHA without Monomethyle Ether Hydroquinone is experimented, and compare to when additing $FeCl_2{\cdot}2H_2O$. A method with a soxhlet extractor compare to the existing rinse method. The hydrophilicity is confirmed by the measurement of a contact angle, and we observe whether the hydrophilicity is retained.

  • PDF

배리어가 포함된 카오스 마이크로 믹서의 개발 (Development of a Barrier Embedded Chaotic Micromixer)

  • 김동성;이석우;권태헌;이승섭
    • 대한기계학회논문집A
    • /
    • 제28권1호
    • /
    • pp.63-69
    • /
    • 2004
  • It is of great interest to enhance mixing performance in a microchannel in which the flow is usually characterized as a low Reynolds number (Re) so that good mixing is quite difficult to be achieved in this laminar flow regime. In this regard, we present a new chaotic passive micromixer, named Barrier Embedded Micromixer (BEM), of which the mixing mechanism is based on chaotic flows. In BEM, chaotic flow is induced by periodic perturbation of the velocity field due to periodically inserted barriers along the channel wall while a helical type of flow is obtained by slanted grooves on the bottom surface of the channel in the pressure driven flow. To experimentally compare the mixing performance, a T-microchannel and a microchannel with only slanted grooves were also fabricated. All microchannels were made of PDMS (Polydimethylsiloxane) from SU-8 masters that were fabricated by conventional photolithography. Mixing performance was experimentally characterized with respect to an average mixing intensity by means of color change of phenolphthalein as pH indicator. It was found that mixing efficiency decreases as Re increases for all three micromixers. Experimental results obviously indicate that BEM has better mixing performance than the other two. Chaotic mixing mechanism, suggested in this study, can be easily applied to integrated microfluidic systems , such as Micro-Total-Analysis-System, Lab-on-a-chip and so on.

Nanotechnology in Biodevices

  • Choi, Jeong-Woo;Oh, Byung-Keun;Kim, Young-Kee;Min, Jun-Hong
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권1호
    • /
    • pp.5-14
    • /
    • 2007
  • Nanotechnology is the creation and utilization of materials, devices, and systems through the control of matter on the nanometer. The technology has been applied to biodevices such as bioelectronics and biochips to improve their performances. Nanoparticles, such as gold (Au) nanoparticles, are the most widely used of the various other nanotechnologies for manipulation at the nanoscale as well as nanobiosensors. The immobilization of biomolecules is playing an increasingly important role in the development of biodevices with high performance. Nanopatteming technology, which is able to increase the density of chip arrays, offers several advantages, including cost lowering, simultaneous multicomponent detection, and the efficiency increase of biochemical reactions. A microftuidic system incorporated with control of nanoliter of fluids is also one of the main applications of nanotechnologies. This can be widely utilized in the various fields because it can reduce detection time due to tiny amounts of fluids, increase signal-to-noise ratio by nanoparticles in channel, and detect multi-targets simultaneously in one chamber. This article reviews nanotechnologies such as the application of nanoparticles for the detection of biomolecules, the immobilization of biomolecules at nanoscale, nanopatterning technologies, and the microfluidic system for molecular diagnosis.

줄기세포 연구의 현황과 의공학 기술과의 접목 (Current Status of Stem cell Research and its Connection with Biomedical Engineering Technologies)

  • 박용두
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권2호
    • /
    • pp.87-93
    • /
    • 2010
  • Researches for stem cells have been focused on scientists in biomedical sciences as well as clinical application for its great therapeutic potentials. Stem cells have two distinct characteristics: self-renewal and differentiation. In this short review, the links between stem cell research and biomedical engineering is discussed based on the basic characteristics of stem cells. This concept can be extended to the fundamental questions of biological sciences for cells such as proliferation, apoptosis, differentiation, and migration. For understanding proliferation and apoptosis of stem cells, techniques from biomedical engineering such as surface patterning, MEMS, nanotechnologies have been used. The advanced technologies such as microfluidic technologies, three dimensional scaffold fabrication, and mechanical/electrical stimulation have also been used in cell differentiation and migration. Basic and unsolved questions in the stem cell research field have limitations by studying conventional technologies. Therefore, the strategic fusion between stem cell biology and novel biomedical engineering field will break the barriers for understanding fundamental questions of stem cells, which can open the window for the clinical applications of stem cell based therapeutics as well as regeneration of damaged tissues.

눈물의 생체 분자 추출을 위한 미세유관이 탑재된 유연한 콘택트 렌즈 (Micro-channel Embedded Soft Contact Lens for Tear Biomolecule Sampling)

  • 김옥철;박형달;송용원;김진석
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권5호
    • /
    • pp.178-185
    • /
    • 2016
  • Tear is a promising biological fluid for non-invasive health monitoring. It has been studied in the past to be a possible candidate for the diagnosis of certain systemic diseases, such as breast cancer, multiple sclerosis, prostate cancer, and diabetes. However, currently existing methods for collecting and extracting tear from the human eye causes inconsistencies in the biomolecule concentrations of the tear sample due to the irritating nature of the process. In response, we designed and fabricated a microfluidic system embedded soft contact-lens for the purpose of tear sampling. The lens was then tested with artificial tear for its tear sampling capability, and found to be able to find concentration equilibrium within 50 minutes. Additionally, simulation was carried out to further optimize the design so that tear sampling rate matched the natural tear turn-over rate of 1 microliter per minute.

Characterization of β-glucosidase from Brown Rot Fungus, Laetiporus sulphureus

  • Lee, Jae-Won;Park, Jun-Yeong;Gwak, Ki-Seob;Koo, Bon-Wook;Choi, In-Gyu
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권5호
    • /
    • pp.100-108
    • /
    • 2007
  • $\beta$-Glucosidase from Laetiporus sulphureus among the enzymes related to lignocellulosic biomass degradation to sugars for using alternative bioethanol production was characterized. The highest activity of $\beta$-glucosidase was obtained on cellobiose at shaking culture. For the characterization and purification of $\beta$-glucosidase culture solution was concentrated and then purified by FPLC using ion exchange and size exclusion column. According to the results of SDS-PAGE, native PAGE and microfluidic system of purified enzyme, protein band was observed at about 132 kDa. Optimal pH and temperature of purified $\beta$-glucosi-dase were 5.0 and $60^{\circ}C$, respectively. In the kinetic properties of $\beta$-glucosidase on various substrates such as sophorose, gentiobiose and cellobiose, $K_m$ was 0.81, 1.07 and 1.70 mM, respectively.

마이크로 채널 내부 유동의 Micro-PIV측정과 제반 문제점 (Micro- PIV Measurements of Microchannel Flows and Related Problems)

  • 이상준;김국배
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 마이크로/바이오 가시화기술부문 학술강연회
    • /
    • pp.79-84
    • /
    • 2002
  • Most microfluidic devices such as heat sinks for cooling micro-chips, DNA chip, Lab-On-Chip, and micro pumps etc. have microchannels of various size. Therefore, the design of practical microfluidics demands detail information on flow structure inside the microchannels. However, detail velocity field measurements are rare and difficult to carry out. In addition, as the microfluidics expands, accurate understanding of microscale transport phenomena becomes very important. In this research, micro-PIV system was employed to measure the velocity fields of flow inside a micro-channel. We carried out PIV measurements for several microchannels with varying channels width, inlet and outlet shape, filters, CCD camera and ICCD camera, etc. For effective composition of micro-PIV system, first of all, it is essential to understand optics related with micro-imaging of particles and the particle dynamics encountered in micro-scale channel flows. In addition, it is necessary to find the optimal condition for given experimental environment and? micro-scale flow to be investigated. The problems encountered in measuring velocity field of micro-channel flows are discussed in this paper.

  • PDF

바이오응용을 위한 압전 공진형 MEMS 소자

  • 김용범;김형준;강지윤;김태송
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 마이크로/바이오 가시화기술부문 학술강연회
    • /
    • pp.1-7
    • /
    • 2002
  • This papers describes the preparation and experimental results of a micro mass detection devices based on cantilever and a diffuser-type micro pump using screen printing thick-film technologies and Si micro-machining. PZT-PCW thick films were prepared by new hybrid method based on the screen printing. By applying these PZT-PCW piezoelectric thick films on actuator, a cantilever for mass detection sensor and a micropump for microfluidic element are successfully fabricated. Resonant frequency and displacement of PZT-PCW thick film actuator in air and in liquid are measured by laser vibrometer system as a function of actuator size. The resonant frequency of PZT-PCW thick film actuator in liquid decreases order of 1/2-1/4 due to damping effect. The sensitivity of cantilever is characterized by Au deposition method which has the mass loading effect such as adsorption of protein. The Sensitivity of PZT-0.12PCW thick film cantilever is proportional to detecting area.

  • PDF

상하좌우 복합유동 유도를 통한 고효율 HVM 마이크로 믹서 설계에 관한 연구 (A Study on Design of an Effective Micromixer using Horizontal and Vertical Multi-mixing (HVM) Flow Motion)

  • 유원설;김성진;강석훈;김판근;박상후
    • 한국정밀공학회지
    • /
    • 제28권6호
    • /
    • pp.751-757
    • /
    • 2011
  • Subminiature devices such as Lab-on-a-chip and p-TAS(Micro Total Analysis System) have been intensively studied in biotechnology and chemistry, In many cases, a micromixer was widely used to mix different solutions for synthesizing novel materials. However, in microfluidic system, there is generally a laminar flow under very small Reynolds number so it is difficult to mix each solution perfectly. To settle this problem, we propose a new mixing mechanism which generates a horizontal and vertical multi-mixing (HVM) flow for effective mixing within a short mixing section. We evaluated the proposed mechanism using CFD analysis, and the results showed that the HVM mechanism had a relative high-effectiveness comparing to the existing methods.

체크밸브가 달린 열공압 방식의 PDMS-유리마이크로 펌프에 관한 연구 (A Study About PDMS-Glass Based Thermopneumatic Micropump Integrated with Check Valve)

  • 고용준;조웅;안유민
    • 대한기계학회논문집A
    • /
    • 제32권9호
    • /
    • pp.720-727
    • /
    • 2008
  • Microfluidic single chip integrating thermopneumatic micropump and micro check valve are developed. The micropump and micorvalve are made of biocompatible materials, glass and PDMS, so as to be applicable to the biochip. By using the passive-type check valve, backward flow and fluid leakage are blocked and flow control is stable and precise. The chip is composed of three PDMS layers and a glass substrate. In the chip, flow channel and pump chamber were made on the PDMS layers by the replica molding technique and pump heater was made on the glass substrate by Cr/Au deposition. Diameter of the pump chamber is 7 mm and the width and depth of the channel are 200 and $180{\mu}m$, respectively. The PDMS layers chip and the heater deposited glass chip are combined by a jig and a clamp for pumping operation, and they are separable so that PDMS chip is used as a disposable but the heater chip is able to be used repeatedly. Pumping performance was simulated by CFD software and investigated experimentally. The performance was the best when the duty ratio of the applied voltage to the heater was 33%.