• Title/Summary/Keyword: microchip

Search Result 136, Processing Time 0.026 seconds

Lead Angle Auto Tuning Technique for Optimal Control of BLDC Motor (BLDC모터 최적 제어를 위한 Lead Angle Auto Tuning 기법)

  • Ahn, Sung-Kuk;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.399-400
    • /
    • 2020
  • 본 논문은 Sensored BLDC 모터의 제어방법을 설명하고, 효율적인 최적 제어를 하기위해 Lead Angle 제어를 하는 방법에 대하여 설명하였다. Lead Angle 값을 실시간 Auto Tuning 하는 기법을 설계 및 구현하였다. 실제 Microchip 사의 DSC를 사용하여 Software로 동작을 구현하였으며, PWM 스위칭 하기 위한 반도체 소자는 IGBT 모듈인 IPM을 사용하여 BLDC 모터의 구동회로인 인버터를 구성하였다. 실제 사용하는 400W급 BLDC 모터를 사용하여 Lead Angle 제어와 Auto Tuning 실험결과를 비교 검증하였다.

  • PDF

Micro-imaging techniques for evaluation of plastic microfluidic chip

  • Kim, Jung-Kyung;Hyunwoo Bang;Lee, Yongku;Chanil Chung;Yoo, Jung-Yul;Yang, Sang-Sik;Kim, Jin-Seung;Park, Sekwang;Chang, Jun-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.239-247
    • /
    • 2001
  • The Fluorescence-Activated Cell Sorter (FACS) is a well-established instrument used for identifying, enumerating, classifying and sorting cells by their physical and optical characteristics. For a miniaturized FACS device, a disposable plastic microchip has been developed which has a hydrodynamic focusing chamber using soft lithography. As the characteristics of the spatially confined sample stream have an effect on sample throughput, detection efficiency, and the accuracy of cell sorting, systematic fluid dynamic studies are required. Flow visualization is conducted with a laser scanning confocal microscopy (LSCM), and three-dimensional flow structure of the focused sample stream is reconstructed from 2D slices acquired at $1\mutextrm{m}$ intervals in depth. It was observed that the flow structure in the focusing chamber is skewed by unsymmetrical velocity profile arising from trapezoidal cross section of the microchannel. For a quantitative analysis of a microscopic flow structure, Confocal Micro-PIV system has been developed to evaluate the accelerated flow field in the focusing chamber. This study proposes a method which defines the depth of the measurement volume using a detection pinhole. The trajectories of red blood cells (RBCs) and their interactions with surrounding flow field in the squeezed sample stream are evaluated to find optimal shape of the focusing chamber and fluid manipulation scheme for stable cell transporting, efficient detection, and sorting

  • PDF

Application of OLED as the Integrated Light source for the Portable Lab-On-a-Chip (휴대형 랩온어칩을 위한 집적화 광원으로의 OLED 적용)

  • Kim, Ju-Hwan;Shin, Kyeong-Sik;Kim, Young-Min;Kim, Yong-Kook;Yang, Yeun-Kyeong;Kim, Tae-Song;Kang, Ji-Yoon;Kim, Sang-Sig;Ju, Byeong-Kwon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.193-197
    • /
    • 2004
  • The organic light emitting diode (OLED) is proposed as the novel source in the microchip because it has ideal merits (various wavelengths, thin-film structure and overall emitting) for the integration. In this paper, we fabricated the finger-type pin photodiodes for fluorescence detection and the advanced microchip with OLED integrated pn the microchannel. The finger-type in the diode design extended the depletion region and reduced the internal resistance about 31.2% than rectangular-type. The photodiodes had a 100pA leakage current and a 8720 sensitivity $(I_{Light}/I_{Dark})$ at -1 V bias. The interference filter with 32 layers ($SiO_2$, $TiO_2$) was directly deposited on the photodiode. The OLED was fabricated on the ITO coated glass and was bonded with LOC. The application of thin-film OLED increased the excitation efficiency and simplified the integration process extremely. The prototype device of this application had a superior sensitivity of 100nM-LOD in the fluorescence detection.

  • PDF

Implementation of 3-D Collision Avoidance Algorithm and Comparison of Micro Controller Unit's Performance using Real-Time Operating System (항공기 3차원 충돌회피 알고리즘 구현과 실시간 운영체계를 이용한 Micro Controller Unit의 성능 비교)

  • Lim, Ji-Sung;Kim, Dong-Sin;Park, In-Hyeok;Lee, Sangchul
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.5
    • /
    • pp.48-53
    • /
    • 2018
  • In this study, Real-Time Operating System(RTOS) and 3-D collision avoidance algorithm are implemented to three different Miciro Controller Unit(MCU)s and their performances compared. We selected Microchip Technology's ATmega2560, STM's ARM Cortex-M3 and ARM Cortex-M4, because they are widely used. FreeRTOS, an open-source operating system, was also used. The 3D collision avoidance algorithm consists of the vertical and the horizontal avoidance algorithm, which is implemented using C++. The performances of the MCUs were compared with respect to used memory and calculation time. As a result, Cortex-M4's calculation time was the fastest and ATmega2560 used least memory.

Development of a real-time Analysis System of Microchip Fluorescence Images based on Server-Client (서버 클라이언트 기반의 실시간 마이크로칩 형광 이미지 분석 시스템 개발)

  • Cho, Migyung;Shim, Jaesool
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1239-1244
    • /
    • 2013
  • In the field of clinical medicine and research, the analysis of such as protein and DNA at the molecular level and even at the cell level are necessary for disease diagnosis and treatment. In many cases, a real time image of samples is needed for the accurate analysis and manipulation of samples since experimental samples are degenerated with time. In this research, a three-dimensional fluorescence microscope device was developed for taking images of protein and DNA inside a single cell and the server-client based image analysis system was made for an integrated management of the real-time images taken from the microscope device. The system consists of a fluorescent measurement device, the associated software and a client program on smartphone. The developed system allows doctors or experimental managers to receive and look at the real-time experimental images taken from the samples of patients anywhere in the emergency, to analyze results and to instantly diagnose the disease and to transfer the results to the patients. As a result, the system is able to be utilized in the implementation of ubiquitous health as well.

BioMEMS-EARLY DISEASE DETECTION (BioMEMS 기반의 조기 질병 진단 기술에 관한 연구)

  • Singh, Kanika;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2781-2784
    • /
    • 2007
  • Early detection of a disease is important to tackle treatment issues in a better manner. Several diagnostic techniques are in use, these days; for such purpose and tremendous research is going on to develop newer and newer methods. However, more work is required to be done to develop cheap and reliable early detection techniques. Micro-fluidic chips are also playing key role to deliver new devices for better health care. The present study focuses on a review of recent developments in the interrogation of different techniques and present state-of-the-art of microfluidic sensor for better, quick, easy, rapid, early, inexpensive and portable POCT (Point of Care testing device) device for a particular study, in this case, bone disease called osteoporosis. Some simulations of the microchip are also made to enable feasibility of the development of a blood-chip-based system. The proposed device will assist in early detection of diseases in an effective and successful manner.

  • PDF

Crystal Growth of Yb:YAG and Fabrication of Microchip Laser Device (Yb:YAG 단결정 성장과 마이크로칩 레이저 소자 제조)

  • 이성영;김충렬;김도진;정석종;유영문
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.8
    • /
    • pp.771-776
    • /
    • 2001
  • 용액인상법으로 질소분위기 하에서 Yb$^{3+}$ 이온이 각각 5, 15, 25 at% 치환된 Yb:Y$_3$Al$_{5}$ O$_{12}$ (Yb:YAG) 단결정을 이리듐 도가니를 사용하여 성장시켰다. 양질의 단결정을 성장시키기 위한 인상속도와 회전속도는 각각 2mm/h와 10rpm이었다. 흡수 및 형광스펙트럼 측정결과, Yb$^{3+}$ 이온의 농도가 높아짐에 따라 흡수계수가 선형적으로 증가하였고, 1051nm 파장을 중심으로 1020~1050nm 영역에서 선폭이 확대된 강한 형광스펙트럼을 나타내었다. 한편, 성장된 단결정을 이용하여 마이크로칩 레이저용 소자를 정밀하게 제조하였다.

  • PDF