• 제목/요약/키워드: micro-implant

검색결과 180건 처리시간 0.021초

Micro-Implant를 이용한 교정치료로 교합평면 개선 후 하악 구치부 수복증례 (Mandibular Posterior Rehabilitation Case after Occlusal Plane Correction using Micro-Implant Anchorage)

  • 박주미
    • 구강회복응용과학지
    • /
    • 제20권2호
    • /
    • pp.143-150
    • /
    • 2004
  • Endosseous implants have been used to provide anchorage control in orthodontic treatment without the need for special patient cooperation. However these implants have limitation like space requirement, cost, equipments. Recently titanium micro-implant for orthodontic anchorage was introduced. Micro-implants are small enough to place in any area of the alveolar bone, easy to implant and remove, and inexpensive. In addition, orthodontic force application can begin almost immediately after implantation. The mandibular first, maxillary first, mandibula second, and maxillary second molars were the four most commonly missing teeth in adult sample. In case of posterior molar teeth missing, deflective contacts in any position, over time, has produced pathologic change of occlusal scheme because of extrusion of opposing teeth. This case had interocclusal space deficiency by mandibular right molars missing over time. The micro-implants had been used for intrusion of maxillary right molars for interocclusal space. The micro-implant would be absolute anchorage for orthodontic movement. Therefore, the micro-implant would be effective method for correction of occlusal plane.

골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석 (Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage)

  • 김찬년;성재현;경희문
    • 대한치과교정학회지
    • /
    • 제33권5호
    • /
    • pp.339-350
    • /
    • 2003
  • 본 연구에서는 활주법을 이용한 전치부 후방 견인시 micro-implant의 다양한 수직적 위치와 전치부에서 힘의 적용점에 따른 치아 이동 양상을 관찰하여 공간 폐쇄시 전치부의 설측 경사와 정출력을 방지할 수 있는 micro-implant의 위치와 전치부 힘의 적용점의 위치를 알아보고자 하였다. 유한 요소 모델을 이용하여 제1소구치가 발거된 상악 치열궁 형태를 제작하고 $.022"{\times}.028"$ 슬롯 브라켓을 모형화하여 치아에 부착시켰다. $.019"{\times}.025"$ stainless steel 선재를 3차원 beam모형으로 제작하고 상악 측절치와 견치 브라켓 사이의 선재 상에 $.032"{\times}.032"$ 크기의 stainless steel hook을 수직으로 8mm의 높이로 형성하였으며, 선재로부터 2mm높이에서 1mm간격으로 8mm까지 힘 적용점을 설정하였다. 지름 1.2mm,길이 6mm의 micro-implant를 제2소구치와 제1대구치 사이의 치조골에 선재로부터 4mm에서 10mm까지 2mm간격으로 4개를 위치시켰다 각각의 micro-implant와 전치부 hook에 150gm의 힘을 적용시켜 다양한 힘 적용점에 따른 치아의 초기 변위를 분석하여 다음의 결과를 얻을 수 있었다. 1. Micro-implant 높이가 4m일 경우 5mm이하의 전치부 hook 높이에서는 전치부 설측 경사 이동이 일어났으며 전치부 hook 높이가 6m이상 되었을 때 전치부 순측 경사 이동이 일어났다. 2. Micro-implant높이가 6mm일 경우 5mm이하의 전치부 hook높이에서 전치부 설측 경사 이동이 일어났으며 전치부 hook 높이가 6mm 이상 되었을 때 전치부 순측 경사 이동이 일어났다 이것은 4mm micro-implant에서의 실험결과와 유사한 이동 양상을 나타내었지만, micro-implant높이가 6mm일 때 전치부 설측 경사 이동이 좀더 감소하였다. 3. Micro-implant높이가 8m일 경우 전치부 hook높이가 2mm일 때 전치의 설측 경사 이동이 일어났으며 3mm이상의 전치부 hook 높이에서 순측 경사 이동이 비례적으로 증가하였다. 4. Micro-implant높이가 10mm일 경우 전치부 hook 높이가 2mm 이상에서 전치의 순측 경사 이동이 비례적ㅇ로 증가하였다. 5. 전치부 hook 높이가 증가할수록 전치의 순측 경사 이동이 증가되지만 선재의 뒤틀림에 의한 변형이 증가되므로 견치와 소구치 부위에서 정출력이 발생하는 바람직하지 못한 치아 이동 양상이 일어났다. 6. Micro-implant를 이용한 상악 5전치 후방 견인시 구치부의 이동은 선재와 브라켓 사이의 마찰력에 의해서 원심경사 이동이 발생하였다.

다양한 마이크로쓰레드(Micro thread)의 개수를 가지는 임플란트의 상부구조물 형상과 하중조건에 따른 3차원 유한요소해석을 이용한 하악골의 응력분포에 관한 연구 (Three-dimensional Stress Analysis of Implant Systems with Micro Threads in the Maxillary Bone)

  • 신하식;한종현;이수홍;전흥재
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.179-186
    • /
    • 2005
  • A comparative study of stress distributions in the maxillary bone with three different types of abutment was conducted. Finite element analysis was adopted to determine stress generated in the bone with the different implant systems with micro threads (Onebody type implant, Internal type implant, and External type implant). It was found that the types of abutments and the number of micro threads have significant influence on the stress distribution in the maxillary bone. They were due to the difference in the load transfer mechanism and the size of contact area between abutment and fixture. Also the maximum effective stress in the maxillary bone was increased with increasing inclination angle of load. It was concluded that the maximum effective stress in the bone was the lowest by the internal implant among the maximum effective stresses by other two types of implants and by appropriate number of micro threads, and that the specific number of micro thread was existed to decrease the maximum effective stress in the maxillary bone due to different implant systems and loading conditions.

고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구 (Effects of drilling process in stability of micro-implants used for the orthodontic anchorage)

  • 장영일;김종완
    • 대한치과교정학회지
    • /
    • 제32권2호통권91호
    • /
    • pp.107-115
    • /
    • 2002
  • 본 연구는 교정적 고정원을 얻기 위하여 micro-implant(Osas$^{(R)}$, Epoch medical)를 drill method와 drill-free method로 매식시, 조기 교정력에 대한 각각의 경우 micro-implant의 역학적 안정성 및 조직학적 생체 적합도의 차이를 알아보고자 시행하였다. 두 마리의 실험견(beagle dog)을 대상으로 상, 하악 협측과 구개부위에 좌우측을 구분하여 drill method 군과drill-free method 군으로 나누어 매식하였다. 매식 한 재료는 직경 1.6 mm의 micro-implant를 사용하였으며, drill method 군 16개, drill-free method 군 16개, 총32개의 micro-implant를 식립하였다. 교정력은 매식 후 1주 뒤에 Ni-Ti coil spring(Ni-Ti springs-extension$^{(R)}$, Ormco)으로 200 gm - 300 gm의 힘을 적용하였다. 동요도 검사는 희생 전에 Periotest$^{(R)}$(Siemens)로 측정하였다. 매식 12주 후에 관류고정 하였으며 시편은 레진 포매하여 Exakt system$^{(R)}$(Exakt)을 이용하여 비탈회 표본을 제작하였다. 표본은 H-E 염색한 뒤, 광학 현미경 상에서 검경하여 조직학적 소견을 분석하였고 조직계측학적 측정은 골접촉률과 골밀도로 분석하였다. 위와 같은 실험을 통하여 매식한 micro-implant의 탈락률과 동요도, 골접촉률 및 골밀도로 drill method 군과 drill-free method 군의 역학적 안정성 및 조직학적 생체 적합도를 비교, 분석한 결과 다음과 같은 결론을 얻었다. 1. micro-implant와 골의 계면은 기계적 접촉 뿐만 아니라 골유착도 있었다. 2. micro-implant의 탈락은 drill method 군이 더 높았다. 3. 동요도는 drill method 군이 전반적으로 더 컸다. 4. micro-implant와 골접촉 정도는 전반적으로 drill-free method 군에서 양호했다. 5. micro-implant 나사산 사이 내에 존재하는 골밀도는 전반적으로 drill-free method 군에서 더 높았다. 결론적으로, micro-implant는 매식시 drill-free method가 drill method보다 탈락률과 동요도 및 골접촉률과, 골밀도에서 더 우수한 결과를 보여 drilling 과정이 안정성과 골조직 치유 및 골유착에 영향을 미친다고 판단된다.

MARGINAL TISSUE RESPONSE TO DIFFERENT IMPLANT NECK DESIGN

  • Bae, Hanna-Eun-Kyong;Chung, Moon-Kyu;Cha, In-Ho;Han, Dong-Hoo
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.602-609
    • /
    • 2008
  • STATEMENT OF PROBLEM: Loss of the marginal bone to the first thread have been accepted but continuous effort have been made to reduce this bone loss by varying implant design and surface texture. PURPOSE: This animal study has examined the histomorphometric variations between implants with micro-thread, micro-grooved and turned surfaced neck designs. MATERIAL AND METHODS: Four mongrel dogs have been used the premolars removed and left to heal for three months. One of each implant systems with turned neck, micro-thread and micro-grooved were placed according to the manufacturers’protocol and left submerged for 8 and 12 weeks. These were then harvested for histological examination. RESULTS: The histologically all samples were successfully ossointegrated and active bone remodelling adjacent to implants. With the micro-grooved implants 0.40 mm and 0.26 mm of the marginal bone level changes were observed at 8 and 12 weeks respectively. The micro-threaded implants had changes of 0.79 mm and 0.56 mm at 8 and 12 weeks respectably. The turned neck designed implants had marginal bone level changes of 1.61 mm and 1.63 mm in 8 and 12 weeks specimens. A complex soft tissue arrangement could be observed against micro-threaded and micro-grooved implant surfaces. CONCLUSION: Within the limitations of this study, it could be concluded that implants with micro-grooved had the least and the turned neck designed implants had the most changes in the marginal bone level. The textured implant surfaces affect soft tissue responses.

Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography

  • Choi, Jung-Yoo Chesaria;Choi, Cham Albert;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • 제48권4호
    • /
    • pp.202-212
    • /
    • 2018
  • Purpose: Bone-to-implant contact (BIC) is difficult to measure on micro-computed tomography (CT) because of artifacts that hinder accurate differentiation of the bone and implant. This study presents an advanced algorithm for measuring BIC in micro-CT acquisitions using a spiral scanning technique, with improved differentiation of bone and implant materials. Methods: Five sandblasted, large-grit, acid-etched implants were used. Three implants were subjected to surface analysis, and 2 were inserted into a New Zealand white rabbit, with each tibia receiving 1 implant. The rabbit was sacrificed after 28 days. The en bloc specimens were subjected to spiral (SkyScan 1275, Bruker) and round (SkyScan 1172, SkyScan 1275) micro-CT scanning to evaluate differences in the images resulting from the different scanning techniques. The partial volume effect (PVE) was optimized as much as possible. BIC was measured with both round and spiral scanning on the SkyScan 1275, and the results were compared. Results: Compared with the round micro-CT scanning, the spiral scanning showed much clearer images. In addition, the PVE was optimized, which allowed accurate BIC measurements to be made. Round scanning on the SkyScan 1275 resulted in higher BIC measurements than spiral scanning on the same machine; however, the higher measurements on round scanning were confirmed to be false, and were found to be the result of artifacts in the void, rather than bone. Conclusions: The results of this study indicate that spiral scanning can reduce metal artifacts, thereby allowing clear differentiation of bone and implant. Moreover, the PVE, which is a factor that inevitably hinders accurate BIC measurements, was optimized through an advanced algorithm.

치과용 티타늄 임플란트의 골융합 증진을 위한 체어사이드 친수성 표면처리방법 (Chair-side surface treatment method for inducing hydrophilicity in titanium dental implant)

  • 이정환;전수경;이해형
    • 대한치과의사협회지
    • /
    • 제54권12호
    • /
    • pp.985-995
    • /
    • 2016
  • Titanium (Ti) has been widely used for dental implant due to great biocompatibility and bonding ability against natural alveolar bone. A lot of titanium surface modification has been introduced in dentistry and, among them, methods to introduce micro/nano-roughened surface were considered as clinically approved strategy for accelerating osseointegration of Ti dental implant. To have synergetic effect with topography oriented favors in cell attachment, chair-side surface treatment with reproducibility of micro/nano-topography is introduced as next strategy to further enhance cellular functionalities. Extensive research has been investigated to study the potential of micro/nano-topography preserved chair-side surface treatment for Ti dental implant. This review will discuss ultraviolet, low level of laser therapy and non-thermal atmospheric pressure plasma on Ti dental implant with micro/nano-topography as next generation of surface treatment due to its abilities to induce super-hydrophilicity or biofunctionality without change of topographical cues.

  • PDF

다양한 설계변수를 고려한 수직하중을 받는 일체형 임플랜트의 최적설계 (AN OPTIMIZATION OF ONEBODY TYPE IMPLANT SYSTEM CONSIDERING VARIOUS DESIGN PARAMETERS)

  • 최재민;전흥재;이수홍;한종현
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.185-196
    • /
    • 2006
  • Statement of problem: The researches on the influence of design variables on the stress distribution in cortical and trabecular bones and on optimal design for implant system were limited. Purpose: The purpose of this study is to identify the sensitivities of design parameters and to suggest the optimal parameters for designing the onebody type implant system. Material and methods: Stresses arising in the implant system were obtained by finite element analysis using a three dimensional model. An onebody type implant system[Oneplant (Warrantec. Co. Ltd., Korea)] was considered in this study. Vortical load(150 N) was applied on the top of the abutment along the axial direction. The initial design variables set for sensitivity analysis were radius of fixture, numbers of micro thread, numbers of power thread, height of micro thread, future length, tapered angle of future, inclined angle of thread, width of micro thread and width of power thread. The statistical technique of Design of Experiments(DOE) was applied tn the simulation model to deduce effective design parameters on stress distributions in bones. The deduced design parameters were incorporated into a fully automated design tool which is coupled with the finite element analysis and numerical optimization to determine the optimal design parameters. Results: 1. The result of sensitivity analysis showed six design variables - radius of future, tapered angle of fixture, inclined angle of thread, numbers of power thread, numbers of micro thread and height of micro thread - were more influential than the others. 2. The optimal values of design variables can be deduced by coupling finite element analysis (FEA) and design optimization tool(DOT).

rhTGF-${\beta}2$/PLGA 복합체를 electrospray법으로 코팅한 타이타늄 임플란트 골 유착의 microCT 계측: a preliminary rabbit study (Osseointegration of the titanium implant coated with rhTGF-${\beta}2$/PLGA particles by electrospray: a preliminary microCT analyzing rabbit study)

  • 이우성;김성균;허성주;곽재영;이주희;박지만;박윤경
    • 대한치과보철학회지
    • /
    • 제52권4호
    • /
    • pp.298-304
    • /
    • 2014
  • 목적: 본 선행 연구는 recombinant human transforming growth factor-${\beta}2$ (rhTGF-${\beta}2$)/ poly lactic-co-glycolic acid (PLGA) 복합체를 타이타늄 임플란트에 처리하였을 때 골 유착에 미치는 영향을 알아보기 위해 시행된 것으로 토끼 모델을 사용하였다. 재료 및 방법: 8개의 임플란트를 300V에서 3분 동안 양극 산화하였다. 그 중 4개는 electrospray법으로 rhTGF-${\beta}2$/PLGA를 코팅하여 실험군으로 설정하였다. 4마리의 New Zealand rabbit의 tibiae에 1개씩의 실험군과 대조군 임플란트를 식립하였으며, 3주와 6주에 2마리씩 희생하여 micro-computed tomography(microCT) 촬영 후 분석하였다. 결과: Scanning electron microscope (SEM) 사진에서 rhTGF-${\beta}2$/PLGA 입자가 임플란트 표면에 균일하게 분산되어 있음을 확인하였다. MicroCT 분석 결과 통계적으로 유의하지는 않지만 rhTGF-${\beta}2$/PLGA를 처리한 임플란트가 bone volume/total volume (BV/TV)와 trabecular thickness (Tb.Th) 값이 더 높은 경향성을 보였으며, cross sectional view에서 더 많은 골이 형성되었음을 확인하였다. 결론: rhTGF-${\beta}2$/PLGA 표면처리된 임플란트가 주변 골의 양적 성장을 촉진시킬 수 있으며 임플란트 초기 골 유착을 증진시킬 수 있는 가능성을 보였다.

마이크로패터닝을 부여한 임플란트 주변골에서의 하중 분포에 관한 유한요소분석법적 연구 (Finite Element Analysis of Stress Distribution around the Micro-Patterned Implants)

  • 허배녕;김대곤;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제24권1호
    • /
    • pp.67-76
    • /
    • 2008
  • 골조직이 자라 들어갈 수 있는 적절한 크기의 마이크로패터닝을 부여하면 강하고 지속적인 골유착을 이룰 수 있는 생역학적 결합을 이룰 수 있다. 또한 마이크로패터닝을 통해 골조직과 접촉하는 면적을 증가시킴으로써 하중을 적절히 분산시킬 수도 있다. 본 연구에서는 마이크로패터닝의 형태와 크기에 따른 응력의 분산에 대해 연구하였다. 나사 하나에서의 하중을 연구하기 위해 2차원 유한요소분석법을 이용하였다. 임플란트는 무한히 긴 피질골에 100% 접촉하며 골-임플란트 계면은 고정된 것으로 경계조건을 설정한 후 마이크로패터닝의 위치와 수에 따라 5군으로 나누어 축력을 가한 후 최대응력과 응력의 분산양상을 비교하였다. 연구 결과, 마이크로패터닝을 부여하면 일반적인 나사에 비해 응력을 보다 넓게 분산시켰으며 나사의 하방에 마이크로패터닝을 부여한 것이 상방에 부여한 것보다 더 고르게 응력을 분산시켰다. 3개의 마이크로패터닝을 부여한 군이 2개의 마이크로패터닝을 부여한 군에 비해 응력을 넓게 분산시켰으나 응력이 집중되는 부위가 나타났다. 이상의 결과를 통해 마이크로패터닝을 부여하면 응력의 분산효과가 있으며 특히 나사 하방에 부여하는 것이 더 큰 효과를 냄을 알 수 있었다.