Browse > Article

Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage  

Kim, Chan-Nyeon (Department of Orthodontics, College of Dentistry, Kyungpook National University)
Sung, Jae-Hyun (Department of Orthodontics, College of Dentistry, Kyungpook National University)
Kyung, Hee-Moon (Department of Orthodontics, College of Dentistry, Kyungpook National University)
Publication Information
The korean journal of orthodontics / v.33, no.5, 2003 , pp. 339-350 More about this Journal
Abstract
The purpose of this study was to investigate the micro-implant height and anterior hook height to prevent maxillary six anterior teeth from lingual tipping and extruding during space closure. We manufactured maxillary dental arch form, bracket and wire, using the computer aided three-dimensional finite element method. Bracket was $.022 slot size and attached to tooth surface. Wire was $.019 stainless steel and $.032 stainless steel hook was attached to wire between lateral incisor and canine. Length of hook was 8mm and force application points were marked at intervals of In. Four micro-implants were implanted on alveolar bone between second premolar and first molar. The heights of them were 4, 6, 8, 10mm starting from wire. We analyzed initial displacement of teeth by various force application point applying force of 150gm to each micro-implant and anterior hook. The conclusions of 4his study are as the following : 1. When the micro-implant height was 4m and the anterior hook height was 5mm and below, anterior teeth were tipped lingually. When the anterior hook height was 6mm and above, anterior teeth were tipped labially. 2. When the micro-implant height was 6mm and the anterior hook height was 6mm and below, the anterior teeth were tipped lingually. When the anterior hook height was 6m and above, the anterior teeth were tipped labially. But lingual tipping of anterior teeth decreased and labial tipping Increased when the micro-implant height was 6mm, compared with 4mm micro-implant height. 3. When the micro-implant height was 8mm and the anterior hook height was 2mm, the anterior teeth were tipped lingually. When the anterior hook height was 3mm and above, labial tipping movement of the anterior teeth increased proportionally. 4. When the micro-implant height was 10mm and the anterior hook height was 2mm and above, labial tipping of the anterior teeth increased proportionally. 5. As the anterior hook height increased, aterior teeth were tipped more labially. But extrusion occurred on canine and premolar area because of the increase of wire distortion. 6. Movement of the posterior teeth was tipped distally during maxillary six anterior teeth retraction using micro-im plant because of the friction between bracket and were Based on the results of this study, we could predict the pattern of the tooth movement according to position of micro-implant and height of anterior hook. It seems that we can find the force application point for proper tooth movement in consideration of inclination of anterior anterior teeth, periodontal condition, overjet and overbite
Keywords
Micro-implat; Thee-dimensional finite element; Sliding mechaism; Orthodontios;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Merrifield LL, Cross JJ. Directional forces. Am J Orthod 1970 : 57 :435-64
2 장세경, 성재현. 각형선재에 가해진 torque가 상악 4전치부 치근막에 발생시키는 응력에 관한 유한 요소법적 분석. 경북대학교 치의학박사 학위논문 2000
3 Linkow LI. The endosseous blade implant and its use in orthodontics. Int J Orthod 1969 : 7 : 149-54
4 Roberts WE, Smith RK, Zilberman Y, Mozsary PG, Smith RS. Osseous adaptation to continuous loading of rigid endosseous implants. Am J Orthod 1984 : 86 : 95-111
5 임상전. 유한요소법 입문. 동명사 1985
6 leon PD, Turley PK, Moon HE, Ting K. Analysis of stress in the periodontium of the maxillary first molar with a three-dimensional finite element model. Am J Orthod Dentofac Orthop 1999: 115: 267-74
7 Tanne K, Koenig HA, Burstone CJ. Moment to force ratios and the center of rotation. Am J Orthod Dentofac Orthop 1988 : 94 : 426-31
8 하도원. 교정용 각형 선재에 부여된 torque가 브라켓에 발생시키는 모멘트에 관한 유한요소법적 분석. 대치교정지 2001 : 31 : 335-46
9 Bennett JC, Mclaughlin RP, Controlled space closure with a preadjusted appliance system J Clin Orthod 1990: 24 : 251-60
10 Gjessing P. Controlled retraction of maxillary incisors. Am J Orthod Dentofac Orthop 1992 : 101 : 120-31
11 Andrew LF. The six key to normal occlusion. Am J Orthod 1972 : 62 : 296-309
12 이유진, 박수병. 상악 전치의 후방견인시 J-hook headgear의 사용이 응력분포 변화에 미치는 영향에 대한 광탄성학적 연구. 대치교정지 1996 : 26: 697-709
13 Creekmore TD, Eklund MK. The possibility of skeletal anchorage. J Clin Orthod 1983 : 17 : 266-9
14 임상전. 유한요소법 입문. 동명사 1985
15 민상홍, 융영주, 김광원. Space closing loop에 의해 야기되는 상악 절치부 이동양상에 관한 역학적 연구. 대치교정지 1995 : 25 : 143-52
16 Siatkowski RE. Continuous arch wire closing loop design, optimization, and verification. Part II Am J Orthod Dentofac Orthop 1997 : 112 : 487-95
17 McLaughlin RP, Bennett JC. The Transition from Standard Edgewise to Preadjusted Appliance System. J Clin Orthod 1989 : 23 : 142-53
18 Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 1997 : 31 : 763-7
19 Cobo J, Sicilia A, Arguelles J, Suarez D, Manuel Vijande. Initial stress induced in periodontal tissue with diverse degrees of bone loss by an orthodontic force : tridimensional analysis by means of the finite element method. Am J Orthod Dentofac Orthop 1993 : 104 : 448-54   DOI   ScienceOn
20 치주과학 교수협의회 : 치주과학 .군자출판사 1996
21 Coolidge ED. The thickness of the human periodontal membrane. J Am Aent Asso 1937: 24 : 1260-70 cited by Tanne K, Nigataki T, InoueY and SakudaM : Pattern of initial displacement associate with various root lengths and alveolar bone height. Am J Ortho Dentofac Orthop 1991 : 100: 66-71
22 Kronfeld F. Histologic study of the influence of function on the human periodontal membrane. J Am Dent Assoc 1931 : 18 : 1942
23 Wheeler's dental anatomy, physiology, and occlusion, 6th ed. WE Saunder Co. LA USA 1984
24 Davis HD, Retraction and alignment of upper incisors with a sliding labial arch, British J Orthod 1981 : 81 : 19-22
25 Andrews LF. The straightwire appliance: Extraction series bracket. J Clin Orthod 1976 : 10 : 581-8
26 Sugawara J. JCO interviews, Dr. Junii Sugawara on the skeletal anchorage system. J Clin Orthod 1993 : 33 : 689-96
27 Guray E, Orhan M. 'En Masse' retraction of maxillary anterior teeth with anterior headgear. Am J Orthod Dentofac Orthop 1997 : 112 : 473-9
28 Siatkowski RE. Continuous arch wire closing loop design, optimization, and verification. Part I Am J Orthod Dentofac Orthop 1997 : 112 : 393-402
29 천옥진, 김태우, 서정훈. 상악 4절치의 후방견인시 나타나는 현상에 관한 유한요소법적 분석. 대치교정지 1995 : 25 : 525-41
30 Siatkowski RE. Force System Analysis of V-Bend Sliding Mechanics. J Clin Orthod 1994 : 28 : 539-46
31 Tanne K, Hiraga J, Kakiuchi K, Yamagata Y, Sakuda M. Biomechanical effect of anteriorly directed extraoral forces on the craniofacial complex : A study using the finite element method. Am J Orthod Dentofac Orthop 1989 : 95 : 200-7   DOI   ScienceOn
32 Gainsforth BL, Higley LB. A study of orthodontic anchorage possibilities in basal bone. Am J of Oral Surg 1945 : 31 : 406-17
33 박효상. Micro-implant를 이용한 교정치료. 나래출판사 2001
34 Block MS, Hoffman DR. A new device of absolute anchorage for orthodontics. Am J Orthod Dentofac Orthop 1995 : 107: 251-8