• Title/Summary/Keyword: micro-concrete

Search Result 516, Processing Time 0.024 seconds

A Fundamental Study on the Adequacy of Use of Micro Fines Including in Crushed Aggregate Using Methylene Blue Test (메틸렌 블루 시험을 이용한 콘크리트용 부순모래에 함유된 미세골재의 사용타당성에 관한 기초적 연구)

  • 안남식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.205-210
    • /
    • 2002
  • As the deposits of natural sands have slowly been depleted, it has resulted in an increase in manufactured fine aggregate (MFA). Standard specifications for fine aggregate for concrete contained in KS F 2558 permit a maximum of 7 percent finer than the No. 200 sieve (75${\mu}{\textrm}{m}$). Since the production process for MFA normally generates 10 to 20 percent of micro fines-which is defined as aggregates passing the No. 200 sieve (75${\mu}{\textrm}{m}$)-more than permitted by specifications, Excess fines must be removed by screening and/or washing operations. The amount of by-products will continue to grow as production increases with environmental discharge restrictions. This fundamental study focuses on experimental research for the adequacy of use of micro fines included in crushed aggregate using methylene blue test. Total of 63 types of sands from seven different rocks were tested. Based on the test results, the methylene blue test was turned out to be a good indicator of the quality of micro fines for concrete and a supplementary article and an amendment of the KS standard were recommended.

  • PDF

New maintenance method of concrete micro crack using repair stick with self-healing capability and manufacture of repair stick containing the self-healing ingredient (균열자기치유조성물을 함유한 균열보수스틱 제조 및 그를 이용한 새로운 콘크리트 미세균열 보수방법)

  • Ahn, Tae Ho;Kim, Hong Gi;Kim, Kyung Min;So, Kwang Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.111-112
    • /
    • 2014
  • This research focuses on the study that micro-crack of concrete is repaired to use self-healing technology. Self-healing concrete is widely studied in domestic and international construction field recently. Micro-crack(less than 0.3mm)of concrete is repaired using a crack repair stick which containing self-healing agents. Therefore, the crack on construction structure will be easily repaired by using a crack repair stick. Also experiment was proceeded because of evaluating the long term durability.

  • PDF

Micro-silica Mixed Aqua-epoxy for Concrete Module Connection in Water : Part 1 - Material Development and Evaluation (해상 프리캐스트 콘크리트 부유체 모듈 가접합을 위한 마이크로 실리카 혼입 수중용 에폭시 접합 성능 검토 : Part 1 - 재료 개발 및 성능 검토)

  • Choi, Jin-Won;Kim, Young-Jun;You, Young-Jun;Kwon, Seung-Jun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • Recent studies on concrete floating structure development focused on connection system of concrete modules. Precast concrete modules are designed to be attached by prestressing in the water, exposing the structure to the loads from water and making the construction difficult. Therefore, a development of bond material became a key issue in successful connection of floating concrete modules. In this study, micro-silica mixed aqua epoxy (MSAE) is developed for the task. Existing primer aqua epoxy, originally used as a bond material for the retrofit of concrete structures using fiber reinforced polymers, is evaluated to find the optimum micro-silica added mix proportion. Micro-silica of 0~4 volume % was mixed in standard mixture of aqua epoxy. Then, the material property tests were performed to study the effect of micro-silica in aqua epoxy by controlling the epoxy silane proportion by 0, ${\pm}5$, ${\pm}10%$. The optimum mix design of MSAE was derived based on the test results. The MSAE was used to connect concrete module specimens with the epoxy thickness variation of 5, 10, and 20mm. Then, 3-point loading test was performed to verify the bond capacity of MSAE. The results show that MSAE improves the bond capacity of concrete module.

Development of Self-Repairing Smart Concrete Using Micro-Biologically Induced Calcite Precipitation (미생물의 방해석 석출 작용을 이용한 자기보수 스마트 콘크리트 개발에 관한 연구)

  • Kim, Wha-Jung;Ghim, Sa-Youl;Park, Sung-Jin;Choi, Kil-Jun;Chun, Woo-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.547-557
    • /
    • 2010
  • This paper presents a study on the development of next generation smart concrete in an eco-friendly manner using micro-biologically induced calcite precipitation (MICP) via microbial biomineralization. It seems that currently, the reformation and functional improvement of concrete using MICP can be achieved using Sporosarcina pasteurii, which is a representative microorganism that produces calcite precipitation. Based on previous studies on MICP the biochemical tests and crystallinity evaluation of cement using sporoasrcina pasteurii and four additional micro-organisms from the concrete structures as identified by 16S rDNA sequence analysis were conducted. Also by applying the Sporosarcina pasteurii and separated four effective micro-organisms from the concrete structures to mortar, the compressive strength improvement by varying curing conditions, repair of crack were examined, and plans for future study were suggested. The effect of the application of effective micro-organisms can lead to the development of a new material that will contribute to resolution of environmental problems and facilitate repair work, and this can also serve as a new research theme in the future. In addition, the importance of this study is to use micro-organism, which is found common in concrete structures, this new microbial is not only environmentally safe but also persists in the natural environment for an extended period of time. Therefore, it seems to have a great potential to became a new environmentally low-burdened functional material.

Experimental Investigation on the Blast Resistance of Fiber-Reinforced Cementitious Composite Panels Subjected to Contact Explosions

  • Nam, Jeongsoo;Kim, Hongseop;Kim, Gyuyong
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.29-43
    • /
    • 2017
  • This study investigates the blast resistance of fiber-reinforced cementitious composite (FRCC) panels, with fiber volume fractions of 2%, subjected to contact explosions using an emulsion explosive. A number of FRCC panels with five different fiber mixtures (i.e., micro polyvinyl alcohol fiber, micro polyethylene fiber, macro hooked-end steel fiber, micro polyvinyl alcohol fiber with macro hooked-end steel fiber, and micro polyethylene fiber with macro hooked-end steel fiber) were fabricated and tested. In addition, the blast resistance of plain panels (i.e., non-fiber-reinforced high strength concrete, and non-fiber-reinforced cementitious composites) were examined for comparison with those of the FRCC panels. The resistance of the panels to spall failure improved with the addition of micro synthetic fibers and/or macro hooked-end steel fibers as compared to those of the plain panels. The fracture energy of the FRCC panels was significantly higher than that of the plain panels, which reduced the local damage experienced by the FRCCs. The cracks on the back side of the micro synthetic fiber-reinforced panel due to contact explosions were greatly controlled compared to the macro hooked-end steel fiber-reinforced panel. However, the blast resistance of the macro hooked-end steel fiber-reinforced panel was improved by hybrid with micro synthetic fibers.

Damage Evaluation on the Concrete Using Acoustic Emission (음향방출(AE)을 이용한 콘크리트의 손상도 평가)

  • 이웅종;조홍동;이종열;한상훈
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.750-758
    • /
    • 2002
  • Concrete is deformed by load and subjected to micro damage under allowable deformation because of non-homogeneous property. When micro damage is accumulated, it is cracked and finally fractured. Characterization of AE can be demonstrated the micro damage which it is not discovered from visual observation, and it become known to an advantage that was clearly discriminated from the existing NDT method. This study was carried out the analysis and evaluation of concrete damage by acoustic emission technique. As a results of damage analysis, it was found out that the more concrete strength has increased, the more concrete has subjected to micro damage at lower stress ratio for chylinder specimen, and this is possible only AE method which could be described the brittle properties. Also it was revealed that the kaiser effect and felicity effect were existed in reinforced concrete bending specimens and it is found out that the onset of interface debonding between concrete and steel could be conformed in comparison with felicity ratio, AE activity and load history. From the results of this study, it was conformed that the deteriorative degree of reinforced concrete structure should be evaluated using felicity ratios.

Corrosion Quantification of Reinforcing Bar in Concrete Using Micro Computer Tomography (Micro-CT 활용 콘크리트 내 철근 부식 정량을 위한 실험적 연구)

  • Jang, In-Dong;Yi, Chong-Ku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.252-253
    • /
    • 2019
  • Corrosion of rebars in reinforced concrete structures is a major factor that shortens the life of the structure. As corrosion progresses, the adhesion between the concrete tissues and the rebar decreases and the cracks in the concrete due to the expansion of the oxide intensify. Although it is necessary to measure corrosion behavior of rebars inside the concrete to measure degradation of structures due to rebar corrosion, no studies have been conducted to measure corrosion of rebars in In-situ state. In this study, corrosion of rebars in reinforced concrete specimens was attempted to be quantified using micro-computer tomography. Since corrosion of concrete takes several months per 10mm of cover, accelerated corrosion techniques were applied. Accelerated corrosion on the specimen was conducted by applying a 10 V magnetic field to the buried rebar and external electrodes with the specimen submerged in a 10% calcium chloride solution. The experiment found that within two weeks, more than 40% of rebar reduction occurred, and the cracks in the radial cracks occurred through the concrete structure, leading to the transfer of the oxide produced through the cracks to the surface of the specimen.

  • PDF

Evaluation of Elastic Modulus of Concrete Using Micro-mechanics Models (콘크리트 탄성계수의 미시역학적 추정)

  • 유동우;조호진;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.345-349
    • /
    • 1995
  • Although heterogeneous materials consisted of micro-constituents are complicated, it is possible to evaulate effective elastic moduli by using micro-mechanics models. In order to evaluate effective elastic moduli of concrete, all aggregates in a representative volume element(RVE) are assumed spherical and randomly distributed. A dilute distribution of inclusions is considered first, and the corresponding overall elastic moduli of the RVE are estimated. Then, the self-consistent method is used in order to take into account the interaction effects. The elastic moduli of concrete are calculated using the models and compared with those of experiment for different volume fractions of the aggregates and elastic moduli of the mortar and the aggregates.

  • PDF

Time Evolution of Water Permeability Coefficient of Carbonated Concrete (탄산화된 콘크리트의 투수계수에 대한 시간단계별 해석)

  • Yoon, In-Seok;Lee, Jeong-Yun;Cho, Byung-Young;Kim, Young-Geun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1053-1056
    • /
    • 2008
  • Permeability coefficient of concrete is a substantial key parameter for understanding the durability performance of concrete and its micro-structural densification. Many researches to deal with the issue have been accomplished, however, it is very rare to deal with the theoretical study on permeability coefficient in connection with carbonation of concrete and the effect of volumetric fraction of cement paste or aggregate on the permeability coefficient. The majority of these researches have not dealt with this issue combined with carbonation of concrete, although carbonation can significantly impact on the permeability coefficient of concrete. The purpose of this study is to establish a fundamental approach to compute the permeability coefficient of (non)carbonated concrete. When simulating micro-structural characteristics as a starting point for deriving a model for the permeability coefficient by the numerical simulation program for cementitious materials, HYMOSTRUC, a more realistic formulation can be achieved. For several compositions of cement pastes, the permeability coefficient is calculated with the analytical formulation, followed by a microstructure-based model. Emphasis is on the micro-structural changes and its effective change of the permeability coefficient of carbonated concrete. The results of micro-structural water permeability coefficient model will be compared with results achieved from permeability experiments.

  • PDF

Micro-vibration Control in Concrete Slabs (콘크리트 슬래브의 미진동 제어)

  • 노병철;변근주;양재성
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.63-72
    • /
    • 1998
  • This study is to develop a technique for micro-vibration analysis and control of concrete slabs to fulfil the vibration criteria for working environments. The proposed technique is for determining the unknown forces from accelerance of two concerned points and the micro-vibration analysis and control of concrete slabs are then validated by numerical model and structural tests. And it is recommended that the natural frequency of structures for micro-vibration control design should be above 25 Hz~30 Hz, and 1.5 times forcing frequency in case of 3~5% structural damping ratio of concrete structures.

  • PDF