• Title/Summary/Keyword: micro system

Search Result 4,278, Processing Time 0.038 seconds

Development of Intravascular Micro Active Endoscope(II) -System Design, Fabrication and In-vitro Evaluation- (혈관 삽입용 초소형 작동형 내시경의 개발(II) - 시스템 설계, 제작 및 체외 성능 분석 -)

  • Chang, Jun-Keun;Chung, Seok;Lee, Yong-Ku
    • Tribology and Lubricants
    • /
    • v.15 no.3
    • /
    • pp.278-286
    • /
    • 1999
  • To predict the behavior of the intravascular micro active endoscope in the real human vascular system, a human mock circulation system was developed. The intravascular micro active endoscope which consists of micro active bending catheter and micro drug infusion catheter was driven in the velocity, Re number and temperature controlled flow. The three SMA (Shape Memory Alloy) zigzag type spring in the micro active bending catheter was heated by the electric current generated by PWM controller, and the shape memory effect made the actuator bend to any direction. The micro drug infusion catheter was driven through the inner hole of the micro active bending catheter. A mock circulation system is shaped from Ascending Arota to Femoral artery according to a human data (the data contains many vascular sizes and hydrographs of many control points). We developed a vascular model with glass and silicone tubes, and set the flow system with circulation parts, flow settling parts, and lots of valves. The heater and heat-controller was added to the How system to centre! the temperature of the How at 36.5$^{\circ}C$. The result showed that the developed intravascular micro active endoscope could be induced to any point in the vascular model.

Micro-Grid System Analysis (마이크로그리드 시스템 해석)

  • Son, Kwang-M.;Lee, Kye-B.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.280-282
    • /
    • 2005
  • Micro-source units having power ratings in thousands of watts can provide even higher reliability and fuel efficiency than the conventional large scale units. These units are also clustered with loads creating micro-grid services to customer sites such as office buildings, industrial parks and homes. Micro-sources adopt voltage source inverter to ensure the power quality of sensitive loads. This paper deals with the connection of micro-sources into the system grid. Modeling and simulation of the grid connected micro-sources at the power frequency range are investigated. Simulation results show that the micro-grid system with two micro-sources has good dynamic characteristics.

  • PDF

Design of Two-way Image Acquisition System for 25\μm Tool Alignment in the Micro Hole Punching (25\μm 홀 펀칭 공구 정렬을 위한 광학 시스템 설계)

  • 주병윤;임성한;오수익
    • Transactions of Materials Processing
    • /
    • v.13 no.3
    • /
    • pp.190-204
    • /
    • 2004
  • The objective of this study is to develop a highly accurate micro tool alignment system applicable to the micro machining technology. In a specific application such as micro hole punching, radial clearance between micro tools is order of a few micron. Under this micron scale tool clearance, accuracy of tool alignment is very important for ensuring hole quality. In the present study, a two-way image acquisition system was developed, which can produce overlapped image of both micro tools that face each other, and applied to the tool alignment in the micro punching. Also, to meet alignment accuracy of tools within $1\mu\textrm{m}$, the cross correlation image processing algorithm was employed. With this system, $25\mu\textrm{m}$ punching tools with $1\mu\textrm{m}$ radial clearance could be accurately aligned.

The Development of Micro Wiring System for Micro Active Endoscope (박막 공정을 이용한 초소형 내시경의 MicroWiring System의 개발)

  • Jung, Seok;Chang, Jun-Keun;Han, Dong-Chul
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.362-365
    • /
    • 1997
  • In the field of Micro-Mechanics, it has been known diffcult to integrate the micro-machine with sensor and source line for the conventional copper line cnanot be used in compact and small size. We developed a system to make thethin copper film as a connect line on the poyurethane pipe (2mm in diameter) by the evaporation technique. This system consists of an evaporation chamber two long branches, substrate hoider and a Linear-Rotary motion feed feedthrough. The results showed that thin copper film coated polyurethanc pipe could be applied th the small medical devices such as the micro active endoscope.

  • PDF

Micro Fluidic Component for a Blood Analysis System (혈액분석기용 유체소자의 설계기술 개발)

  • Kim, Jae Yun;Kim, Duckjong;Heo, Pil Woo;Park, Sang-Jin;Yoon, Eui Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.754-760
    • /
    • 2004
  • The miniaturization and integration are trend of modern blood analyses. Micro-Bio-Fluidics plays an important role in a micro blood analysis system. In this paper, analysis and design technology for blood analysis system is presented. Numerical simulations of a blood flow in micro separator and reservoir are conducted. As a result, we suggest on-chip micro separator, which performed plasma separation from whole blood in micro channels.

  • PDF

A Study on the Dynamic Analysis of Micro-Grid System (Micro-Grid 시스템의 동특성 해석에 관한 기초 연구)

  • Son, Kwang-M.;Lee, Kye-B.;Jeon, In-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.543-544
    • /
    • 2007
  • Micro-grid consists of micro-sources which adopt environmentally friendly and reliable power sources with independent real and reactive power control capability for providing premium power quality. This paper presents dynamic modeling and the stable operating range of the micro-grid system varying the parameters of the micro-sources. Case study results show the parameters affecting the stability of the micro-grid and the stable operating range of the micro-sources.

  • PDF

The Basic Research of Fluid System in Medical Micromachine (의료용 마이크로머신에 있어서 유체 시스템에 관한 기초적 연구)

  • Kim, Dong-Wook;Kim, Nam-Gyun
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.52-56
    • /
    • 1995
  • At present many kinds of micro actuators and micro mechanical components have been studied, but force transmission to arbitary direction is difficult using the current method. To solve this problem, a micro hydraulic system is expected to be useful. Force transmission to arbitary direction is necessary to development of medical use micromachine. In this paper, we studied about micro hydraulic system and magnetic fluid micro actuator and micro rapid prototyping system. The result of this studies indicated that possibility of the power transmission that using the micro cylinder system.

  • PDF

Technology of thin Film Formation by Using the Micro Gravure Coater (마이크로 그라비어 코터를 이용한 박막 형성 기술)

  • Kim, Dong Soo;Kim, Jung Su;Bae, Sung Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.6
    • /
    • pp.596-600
    • /
    • 2013
  • We report here on the processing and manufacturing of thin film for printed electronics by micro-gravure coating system. The micro-gravure coating systems are consisted of various modules such as web and system tension controller, micro-gravure coating units, dispenser and hybrid dry units (UV, NIR, Hot air). Especially, for the optimization of system, the number of idle roller was minimized and tension isolating infeeder was included. Also, we applied four patterns circle, 45 degree, square and 35 degree for the optimizing coating thickness. The micro-gravure coating system which applied various patterns to enable continuous coating process and fast coating time compare with conventional batch coating system. In this paper, introduce of micro-gravure coating system and testing results of coating thickness (20~700nm), coating time (1~2sec) and surface roughness (3~12nm) by using micro-gravure coating system.

Design of a Low-Cost Micro Robotic System for Developing and Validation Control Algorithms

  • Isarakorn, Don;Suksrimuang, Chatchai;Benjanarasuth, Taworn;Ngamwiwit, Jongkol;Komine, Noriyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1945-1948
    • /
    • 2004
  • This paper describes the design and construction of a micro robotic system addressing such important aspects as versatility and low cost for rapid development and test of new control algorithm. The design and structure of micro robots are presented in detail. The supervision oriented concept is designed for controlling a group of micro robots. In this concept, the vision system recognizes the environment and the host computer decides the micro robot action based on the information from the vision system. In addition, the micro robots can be implemented cheaply and small in size because the structure of supervision oriented system is simplest. The experimental results and the performance of the proposed micro robotic system are discussed.

  • PDF

A Study on the Optimum Design for LTCC Micro-Reformer: (Performance Evaluation of Various Flow Channel Structures ('LTCC를 소재로 하는 마이크로 리포머의 최적 설계에 관한 연구: (다양한 채널구조에 따른 성능변화 고찰)')

  • Chung Chan-Hwa;Oh Jeong-Hoon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.551-552
    • /
    • 2006
  • The miniature fuel cells have emerged as a promising power source for applications such as cellular phones, small digital devices, and autonomous sensors to embedded monitors or to micro-electro mechanical system (MEMS) devices. Several chemicals run candidate at a fuel in those systems, such as hydrogen. methanol, ethanol, acetic acid, and di-methyl ether (DME). Among them, hydrogen shows most efficient fuel performance. However, there are some difficulties in practical application for portable power sources. Therefore, more recently, there have been many efforts for development of micro-reformer to operate highly efficient micro fuel cells with liquid fuels such as methanol, ethanol, and DME In our experiments, we have integrated a micro-fuel processor system using low temperature co-fired ceramics (LTCC) materials. Our integrated micro-fuel processor system is containing embedded heaters, cavities, and 3D structures of micro- channels within LTCC layers for embedding catalysts (cf. Figs. 1 and 2). In the micro-channels of LTCC, we have loaded $CuO/ZnO/Al_2O_3$ catalysts using several different coating methods such as powder packing or spraying, dipping, and washing of catalyst slurry.

  • PDF