• Title/Summary/Keyword: micro bubble

Search Result 196, Processing Time 0.027 seconds

Prediction of Two-phase Taylor Flow Characteristics in a Rectangular Micro-channel (사각 마이크로 채널 내 Taylor 유동 특성 예측에 대한 연구)

  • Lee, Jun Kyoung;Lee, Kwan Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.557-566
    • /
    • 2015
  • The characteristics of a gas-liquid Taylor (slug) flow in a square micro-channel with dimensions of $600{\mu}m{\times}600{\mu}m$ are experimentally investigated in this paper. The test fluids were nitrogen and water. The superficial velocities of the liquid and gas were in the ranges of 0.01 - 3 m/s and 0.1 - 3 m/s, respectively. The bubble and liquid slug lengths, bubble velocities, and bubble frequencies for various inlet conditions were measured by analyzing optical images obtained with a high-speed camera. It was found that the measured values (bubble and liquid slug lengths, bubble velocities) were not in good agreement with the values obtained using empirical models presented in the existing literature. Modified models for the bubble and liquid slug lengths and bubble velocity are suggested and shown to be in good agreement (${\pm}20$) with the measured values. Moreover, the bubble frequency could be predicted well by the relationship between the unit cell length and its velocity.

Efficient Micro-Ozone-Bubble Generation by Improving Ozone Dissolution Tank Structure (오존용해탱크 구조 개선을 통한 효율적인 마이크로오존버블 생성)

  • Park, Yong-hwa;Lee, Gwang-hi;Jang, Am
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.10
    • /
    • pp.549-555
    • /
    • 2017
  • The purpose of this study is to investigate how ozone-dissolution-tank structure affects micro-ozone-bubble distribution, energy consumption and water treatment efficiency. The partition walls inside the ozone-dissolution-tank generate pressure changes, shear forces, and swirling flows, which change the size of the bubble diameter. The size of the bubble diameter differs by 10.5% depending on the partition walls. Changes in ozone-bubble diameter are related to energy consumption. As the ozone-bubble becomes smaller, the bubble generation energy increases, but the ozone production energy decreases as the dissolution efficiency increases. Therefore, an ozone-dissolution-tank should be determined by means of an optimal condition producing a micro-ozone-bubble with a minimum sum of bubble generation energy and ozone production energy. The energy consumed to inject the same amount of ozone into the effluent differs by 2.5% depending on the partition walls. However, considering the water treatment efficiency, the conditions for selecting the ozone-dissolution-tank are variable. This is because the free radicals that increase as the ozone-bubble gets smaller are very efficient for water treatment. Even at the same ozone injection concentration, the water treatment efficiency differs by 10.4% according to the partition walls. Therefore, we have studied ozone-dissolution-tank structure which produces reasonable ozone-bubble considering water treatment efficiency and energy efficiency.

The Treatment Properties of Heavy Metals in Acid Mine Drainage with Micro-bubble and UV/H2O2 Oxidation Process (마이크로버블과 자외선/과산화수소 산화공정을 이용한 광산배수의 중금속 처리 특성)

  • Jung, Yong-Jun;Jung, Jae-Ouk
    • Journal of Environmental Science International
    • /
    • v.26 no.3
    • /
    • pp.303-309
    • /
    • 2017
  • Aeration with low energy micro-bubble generation and $UV/H_2O_2$ processes was introduced to verify the possibility of oxidation treatment for acid mine drainage. During 10 hours of aeration with micro-bubbles, Fe and As concentrations were decreased to 18.1 and 61.8%, respectively, while Cu, Cd, Al were kept at influent concentrations. Other heavy metals such as Mn, Cr, Pb, Zn, and Ni concentrations fluctuated due to the repetition of oxidation and release. Twenty days of aeration indicated the oxidation possibility for Cu, Cd, and Al. With the employment of $UV/H_2O_2$ processes, more than 77% of Cu and Fe removed, whereas slightly more than 30% of Cd and Al removed.

Hydraulic Impact Scope and Dissolved Oxygen Distribution by the Micro-bubble Aeration in an Artificial Lake (인공호소에서 마이크로 버블 포기에 의한 수리학적 영향반경과 용존산소 분포)

  • Choi, Sunhwa;Park, Hyungseok
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.263-271
    • /
    • 2016
  • This study investigated the hydraulic impact scope and dissolved oxygen (DO) concentration distribution by the micro-bubble aeration in the Juksan Lake located in Asan city in Chungcheongnam-do province. A tracing experiment for hydraulic impact scope was used which constituted a 20% rhodamine solution. A 160 m-guideline was installed in the horizontal direction of the micro-bubble jet flow and the rhodamine concentration, water temperature, and DO concentration were measured at depths of 1 m, 2 m, and 3 m at intervals of 10 m. In the Juksan Lake, the effective range of jet flow discharged by the micro-bubble generator was about 40 m, and after then the jet plume moved up to 80 m to 120 m through the advection and diffusion processes of ambient water. DO concentration in the lake was maintained at 7.4-12.6 mg/L during tracking experiment. The DO of the lake sediments improved from 0.2 mg/L to 8.0 mg/L after applying micro-bubble aeration. In conclusion, the micro-bubble aeration can be an effective technology for the management and improvement of water quality in an agricultural reservoir.

Characteristics of Cooling for the Adjacent Double Micro-Porous Coated Surfaces in PE5060 (마이크로다공성 코팅된 인접 복수 발열체에 대한 PF5060의 냉각 특성)

  • Kim Tae-Gyun;Kim Yoon-Ho;Lee Kyu-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.7 s.250
    • /
    • pp.646-655
    • /
    • 2006
  • The present research is an experimental study on characteristics of cooling behavior for the adjacent copper blocks with surface roughness or micro-porous coated surface. The experiments were carried out at saturation state or within subcooled states of PF5060. The effects of heater orientation and the intervals between heating surfaces or substrates were investigated under various heat flux conditions. The boiling performance of copper block with micro-porous coated surface was better than that of copper block with surface roughness. It is understood that the bubble sweeping enhances boiling performance for the heaters with inclinations of $\theta=45^{\circ}\;and\;\theta=90^{\circ}$, where as the bubble flattening decreases boiling performance for the heaters with inclinations of $\theta=135^{\circ}\;and\;\theta=180^{\circ}$. In comparison to upper heater and below heater with orientation, the upper heater has lower superheat temperature than the below heater due to the bubble sweeping. It is also found that boiling performance decreases in the case of adjacent double heaters with only 0.2cm substrate interval.

An Ozone Micro-bubble Technique for Seed Sterilization in Alfalfa Sprouts

  • Kwack, Yurina;Kim, Kyoung Koo;Hwang, Hyunseung;Chun, Changhoo
    • Horticultural Science & Technology
    • /
    • v.32 no.6
    • /
    • pp.901-905
    • /
    • 2014
  • The efficacy of ozone micro-bubble water (OMBW) in reducing microbial populations on alfalfa seeds was investigated in this study. We observed the surface of alfalfa seeds using microscopy and found that many cracks and crevices existing on the surface could harbor pathogens. Alfalfa seeds were treated with tap water (TW), micro-bubble water (MBW), ozone water (OW), ozone micro-bubble water (OMBW), and chlorine water (CL) for 5 min, and total microbial population, E. coli and Salmonella spp. colonies were determined. Also, the sterilized seeds were germinated and cultivated for 5 d after sowing to investigate the percentage of germination and the growth of alfalfa sprouts. The treatments with OMBW and CL were most effective in reducing total microbial populations and E. coli was eliminated by OW, OMBW, and CL treatments. CL treatment reduced the percentage of germination and fresh weight of alfalfa sprouts, but OMBW did not cause any negative effects on the germination and growth of alfalfa sprouts. These results indicate that OMBW can be used as an effective sanitizer for eliminating seed-borne pathogens without detrimental effects on seed viability.

Simultaneous measurement of size and velocity of micro-bubbles in an opaque tube using X-ray micro-imaging technique (X-ray 미세 영상기법을 이용한 불투명 튜브 내부 미세기포의 크기 및 속도 동시 측정)

  • Kim Seok;Lee Sang Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.45-46
    • /
    • 2003
  • The x-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to different refractive index. Micro-bubbles of $20\~120{\mu}m$ diameter moving upward in an opaque tube $(\phi=2.7mm)$ were tested. For two different working fluids of tap water and DI water, the measured velocity of micro-bubbles is roughly proportional to the square of bubble size.

  • PDF