• Title/Summary/Keyword: miR-20a

Search Result 541, Processing Time 0.022 seconds

A RADIOGRAPHIC EXAMINATION ON THE THICKNESS OF MANDIBULAR ANGULAR CORTEX AT THE CHILD AND ADOLESCENT (아동 및 청소년기의 하악각부 피질골 두께에 관한 방사선학적 연구)

  • Baik, Byeong-Ju;Kim, Mi-Ra;Rho, Yong-Kwan;Kim, Mun-Hyoun;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.1
    • /
    • pp.225-233
    • /
    • 1998
  • The purpose of this study was to determine the thickness of the cortical bone at the mandibular angle in children and adolescents. The subjects were composed of 153 subjects who were 3 to 17 years of age that had not been history of bone disease or metabolic disease and no dental caries or tooth loss on mandibular molars. The subjects were divided into three age groups, group I (preschool children) was 3 to 5 years of age and grouop II (school children) was 6 to 11 years of age and group III (adolescence) was 12 to 17 years of age. Panoramic radiographs of these patients were collected and measurements of the thickness of the cortical bone were obtained at the mandibular angle. The average thickness of the cortical bone in the group I was 1.01$\pm$0.18 mm in boys and 1.07$\pm$0.22 mm in girls. In the group II was 1.23$\pm$0.18 mm in boys and 1.32$\pm$0.18 mm in girls. In the group III was 1.60$\pm$0.23 mm in boys and 1.58$\pm$0.20 mm in girls. Statistical analyses did not reveal any significant difference between the right or left side of the mandible but difference was exist between the same age groups by sex, especially in group II (p<0.01), except in group III. The greater thickness of cortical bone in the older age group was shown to be statistically significant. The correlation coefficient between age and the thickness of the cortical bone at the mandibular angle showed a high value of r=0.76.

  • PDF

Comparison of Wetting and Drying Characteristics in Differently Textured Soils under Drip Irrigation (점적관개 시 토성별 습윤.건조 특성 비교)

  • Kim, Hak-Jin;Son, Dong-Wook;Hur, Seung-Oh;Roh, Mi-Young;Jung, Ki-Yuol;Park, Jong-Min;Rhee, Joong-Yong;Lee, Dong-Hoon
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.309-315
    • /
    • 2009
  • Maintenance of adequate soil water content during the period of crop growth is necessary to support optimum plant growth and yields. A better understanding of soil water movement for precision irrigation would allow efficient supply of water to crops, thereby resulting in minimization of water drainage and contamination of ground water. This research reports on the characterization of spatial and temporal variations in water contents through three different textured soils, such as loam, sandy loam, and loamy sand, when water is applied on the soil surface using an one-line drip irrigation system and the soils are dried after the irrigation stops, respectively. Water contents through each soil profile were continuously monitored using three Sentek probes, each consisting of three capacitance sensors at 10, 20, and 30cm depths. Spatial variability in water content for each soil type was strongly influenced by soil textural class. There were big differences in wetting pattern and the rate of downward movement between loam and sandy loam soils, showing that the loam soil had a wider wetting pattern and a slower rate of downward movement than did the sandy loam soil. The wetting pattern in loamy sand soil was not apparent due to a low variability in water content (< 10%) by a lower-water holding capacity as compared to those measured in the loam and sandy loam soils, implying that the rate of water drainage below a depth of 30cm was high. When soils were dried, there were highly exponential relationships between water content and time elapsed after irrigation stops ($r^2$${\geq}$0.98). It was estimated that equilibrium moisture contents for loam, sandy loam, and loamy sand soils would be 17.6%, 6.2%, and 4.2%, respectively.

The Significance of Acetylcholine Receptor Autoantibody Test (아세틸콜린 수용체 항체(Acetylcholine receptor autoantibody) 검사의 의의)

  • Yoo, Soh-Yeon;Lim, Soo-Yeon;Pack, Song-Ran;Seo, Mi-Hye;Moon, Hyung-Ho;You, Sun-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.113-116
    • /
    • 2011
  • Purpose: Acetylcholine receptor antibodies cause acetylcholine receptor loss, which is responsible for failure of the neuromuscular junction in the acetylcholine receptor autoantibody. The disease characterized by muscle weakness and fatigue, myasthenia gravis(MG) occurs when the body inappropriately produces antibodies against acetylcholine receptors, and thus inhibits proper acetylcholine signal transmission. And this reason, the measurement of acetylcholine receptor antibodies can be of considerable value in disease diagnosis. Methods: From 2010. August to September, we tested orderd AchRAb 19 samples to get the results. 1. Pipette $5{\mu}{\ell}$ undiluted patient sera and kit control and add 125I AChR $50{\mu}{\ell}$ and incubate at R.T for 2 hours. 2. Pipette $50{\mu}{\ell}$ of anti-human IgG into each tube, and incubate at $2{\sim}8^{\circ}C$ for 2 hours. 3. Pipette $25{\mu}{\ell}$ precipitation enhancer into each tube and add 1mL washing solution into all tubes. 4. Centrifuge each tube for 20minutes at $2{\sim}8^{\circ}C$ at 1500g. 5. Aspirate or decant the supernatant. 6. Pipette 1 mL washing solution into all tubes and resuspend the pellet and repeat centrifugation. 7. Aspirate or decant the supernatant and count all tubes on a gamma counter. Results: Cut off value is 0.2 nmol/L and the results taken below 0.2 nmol/L are negative, the results above that identified as being positive values. We assayed the 19 patients samples and got 7 positive results. Of which, 6 patients were diagnosed as MG.(85.7%). Conclusions: Acetylcholine Receptor autoantibody test is intended for use by persons only for the quantitative determination of it in human serum. Even if measurement of the antibodies is not a routine test, it can be of considerable value in disease diagnosis.

  • PDF

Utility Evaluation of Two-point Calibration Curve applied for TSH, FT4 Tests (TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가)

  • Park, Hye-Mi;Yoo, Seon-Hee;Lee, Seon-Ho;Kim, Nyun-Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.75-79
    • /
    • 2016
  • Purpose The ASAN Medical Center, Nuclear Medicine performs TSH (Thyroid stimulating hormone) and FT4 (Free Thyroxine) tests 8 times per day. Accordingly, 70 ~ 80 kit tubes are consumed every day for the measurements and the time consumed for reagent dispensing averages over 170 seconds, where the TAT (turnaround time) may be effected when the number of test samples is larger than expected. Therefore, the following test was conducted with the purpose to reduce the number of kit tubes consumed, and reduce the time for reagent dispensing. Materials and Methods The test is based on applying the same reagent for tests where the number of samples is 30 or less. The test for TSH was conducted 9 times from July $1^{st}$ 2015 to July $10^{th}$ 2015. The test for FT4 was conducted 4 times from June $18^{th}$ 2015 to June $22^{nd}$, 2015. Standard Solution No.2 (0.153 uU/mL) and No.5 (4.96 uU/mL) was selected as the two-point standards for the TSH test, and Standard Solution No.3 (0.777 ng/dL) and No.4 (2.044 ng/dL) was selected as the two-point standards for the FT4 test. 38 test samples were subject to correlation analysis. Results For TSH, the result of the normal test shows ranges of 0.20 ~ 0.37 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 6.77 ~ 7.94uU/mL for Control3, while the result of two-point calibration curve test shows ranges of 0.18 ~ 0.27 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 7.30 ~ 8.52 uU/mL for Control3. For FT4, the result of the normal test shows ranges of 0.85 ~ 0.94 ng/dL for Control1 and 4.23 ~ 4.57 ng/dL for Control2, while the result of two-point calibration curve test shows ranges of 0.61 ~ 0.75 ng/dL for Control1 and 3.88 ~ 5.71 ng/dL for Control2. For TSH, the CV% of the normal test for Control1, Control2 and Control3 are 10.5, 3.3 and 3.6 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 12.4, 8.2 and 5.1 respectively. The result shows an outstanding correlation of TSH: y = 0.9985x - 0.0459 $R^2=0.9986$. For FT4, the CV% of the normal test for Control1 and Control2 are 0.70 and 0.71 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 8.7 and 16.2 respectively. The result shows an outstanding correlation of FT4: y = 1.2674x - 0.1133 $R^2=0.9824$. Conclusion The two-point calibration curve can be efficiently applied for TSH in cases where the number of test samples is not large, since the number of samples to be re-tested increases when the result is abnormal from the calibration curve. The two-point calibration curve test should not be applied for FT4 where the results do not consistently comply with the quality assessment range. Depending on how the two-point calibration curve is applied, up to 5 test tubes can be conserved per test, and the reduced time for reagent dispensing is anticipated to have a positive effect on the TAT (turnaround time).

  • PDF

A Study on Migration of Ethylenediamine and Hexamethylenediamine from Polyamide Utensils (Polyamide 조리기구로부터 Ethylenediamine 및 Hexamethylenediamine의 이행에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Yoon, Hae-Jung;Jeon, Dae-Hoon;Choi, Hyun-Chul;Kim, Hyung-Il;Sung, Jun-Hyun;Park, Na-Young;Kim, So-Hee;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2010
  • The method for the determination of ethylenediamine (EDA) and hexamethylenediamine (HMDA) in food simulants was developed, and migration amounts of these compounds was monitored for 124 polyamide (PA) utensils. The diurethane derivatives of EDA and HMDA, which produced by reaction with ethyl chloroformate, were analyzed by using gas chromatograph (GC)/flame ionization detector (FID) and GC/mass spectrometer (MS). The developed method was validated with $0.3\;{\mu}g/mL$ of limit of detection (LOD) for EDA and $0.1\;{\mu}g/mL$ of LOD for HMDA, > 0.999 of linearity($r^2$) and > 88% of recovery. The EDA was detected 1.31 and $02.06\;{\mu}g/mL$ for 2 samples in water. The HMDA was detected $0.29\;-\;0.93\;{\mu}g/mL$ for 3 samples in 20% ethanol and $0.26\;-\;0.44\;{\mu}g/mL$ for 10 samples in n-heptane. These migration levels were below the specific migration limits (SML) of $12\;{\mu}g/mL$ and $2.4\;{\mu}g/mL$ for EDA and HMDA established in EU.

The Optimization and Verification of an Analytical Method for Sodium Iron Chlorophyllin in Foods Using HPLC and LC/MS (식품 중 철클로로필린나트륨의 HPLC 및 LC/MS 최적 분석법과 타당성 검증)

  • Chong, Hee Sun;Park, Yeong Ju;Kim, Eun Gyeom;Park, Yea Lim;Kim, Jin Mi;Yamaguchi, Tokutaro;Lee, Chan;Suh, Hee-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.148-157
    • /
    • 2019
  • An optimized analytical method for sodium iron chloriphyllin in foods was established and verified by using high performance liquid chromatography with attached diode array detection. An Inertsil ODS-2 column and methanol-water (80:20 containing 1% acetate) as a mobile phase were employed. The limit of detection and quantitation of sodium iron chloriphyllin were 0.1 and 0.3 mg/kg, respectively, and the linearity of calibration curve was excellent ($R^2=0.9999$). The accuracy and precision were 93.9~104.95% and 2.0~7.7% in both inter-day and intra-day tests. Recoveries for candy and salad dressing were ranged between 93 and 104% (relative standard deviation, (RSD) 0.3~4.3%), and between 83 and 115% (RSD 1.2~2.0%), respectively. Liquid chromatography mass spectrometry was used to verify the main components of sodium iron chlorophyllin which were Fe-isochlorin e4 and Fe-chlorin e4.

Primary Culture of Chicken Tracheal Epithelial Cells and Study on Those Characters for Recombinant Virus Infection (닭 기도 상피세포의 1차 배양과 유전자 재조합 바이러스의 감염 특성 연구)

  • Park, Mi Na;Jang, Hyun-Jun;Keum, Dae Ho;Choi, Jin Ae;Yoo, Jae Gyu;Byun, Sung June;Park, Jong Ju;Ji, Ju Young;Lee, Kyung-Tai;Kim, Tae-Hun;Lee, Hyun-Jeong
    • Korean Journal of Poultry Science
    • /
    • v.40 no.4
    • /
    • pp.299-304
    • /
    • 2013
  • Tracheal epithelial cells (TECs) are an important tool for studies of viral respiratory diseases. Primary TECs have been cultured from human, mouse and hamster. It is also necessary to diagnose viral respiratory disease and reveal infection mechanisms in chicken. In this study, we isolated tracheal epithelial layers from tracheal of 20-day-old chicks and cultured primary TECs from the isolated layers. Ciliated cells which were a typical morphology of TECs were observed in cultured primary TECs and maintained until cell passage 5 (15 to 20 days). When we analyzed expression patterns of epithelial marker genes (retinoic acid responder, FGF-binding protein, virus activating protease (VAP) in TECs compared to immortalized chicken embryonic fibroblast cell line (DF-1), all the marker genes are highly expressed in TECs than in DF-1. When TECs were cultured with 0.1 and 1 MOI of ND virus (rNDV-GFP strain) to test the susceptibility of TECs for ND virus, 12.6% and 48.2% of the incubated TECs were infected respectively. In addition, when DF-1 was incubated with 1 MOI of ND virus, the virus infection rate of DF-1 was three times lower than the virus infection rate of TECs. These data could contribute to study infection mechanisms of viral respiratory diseases and control them in chicken.

Tyrosinase Inhibitory Effect of (E)-2-(substituted benzylidene)-2,3-dihydro-1H-cyclopenta[a]naphthalen-1-one Derivatives ((E)-2-(substituted benzylidene)-2,3-dihydro-1H-cyclopenta[a]naphthalen-1-one 유도체들의 tyrosinase 활성억제 효과)

  • Lee, Eun Kyeong;Kim, Ju Hyun;Moon, Kyoung Mi;Ha, Sugyeong;Noh, Sang-Gyun;Kim, Dae Hyun;Lee, Bonggi;Kim, Do Hyun;Kim, Su Jeong;Ullah, Sultan;Moon, Hyung Ryong;Chung, Hae Young
    • Journal of Life Science
    • /
    • v.27 no.2
    • /
    • pp.139-148
    • /
    • 2017
  • The inhibition of tyrosinase, a key enzyme in mammalian melanin synthesis, plays an important role in preventing skin pigmentation and melanoma. Therefore, tyrosinase inhibitors are very important in the fields of medicine and cosmetics. However, only a few tyrosinase inhibitors are currently available because of their toxic effects on skin or lack of selectivity and stability. Therefore, we synthesized a novel series of (E)-2-(substituted benzylidene)-2,3-dihydro-1H-cyclopenta[a]naphthalen-1-one derivatives and evaluated their inhibitory effects on mushroom tyrosinase, with the aim of discovering a novel tyrosinase inhibitor. Among 19 derivatives, MHY3655 ($IC_{50}=0.1456{\mu}M$) showed the strongest inhibitory effect on tyrosinase activity compared to kojic acid ($IC_{50}=17.2{\mu}M$), a well-known tyrosinase inhibitor. In addition, MHY3655 showed competitive inhibition on Lineweaver-Burk plots. We confirmed that MHY3655 strongly interacts with mushroom tyrosinase residues through the docking simulation. Substitutions with a hydroxy group at both R2 and R4 in the phenyl ring indicated that these groups play a major role in the high binding affinity to tyrosinase. Further, MHY3655 did not show cytotoxicity at the concentrations tested in B16F10 melanoma cells. In conclusion, the novel compound MHY3655 potentially shows tyrosinase inhibitory activity, and it could be used as an ingredient in whitening cosmetics.

Characteristics of Biochemical Markers and Whole-Wheat Flours Using Small-Scaled Sampling Methods in Korean Wheats

  • Park Chul Soo;Kim Yang-Kil;Han Ouk-Kyu;Lee Mi Ja;Park Jong-Chul;Seo Jae-Hwan;Hwang Jong-Jin;Kim Jung-Gon;Kim Tae Wan
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.5
    • /
    • pp.346-355
    • /
    • 2005
  • To investigate the application of biochemical markers' and small-sample methods using whole-wheat flours for screening in early generation in Korean wheat breeding system, 74 Korean wheats, including cultivars, local breeding lines and experimental lines, were analyzed. Seed storage protein and amylose contents of grains were evaluated. Biochemical makers, including granule bound starch synthase (GBSS), high molecular weigh glutenin subunits (HMW-GS) and friabilin were also evaluated by using one-dimensional sodium dodecyl sulfate-polyacryla-mide gel electrophoresis with a single kernel. The small­sample methods, including modified SDS-sedimentation test (MST), micro-alkaline water retention capacity (AWRC) and whole-wheat flour swelling volume (WSV) were also tested in this study. Protein content, MST and AWRC was $11.0 - 15.8\%$, 2.7 - 26.2 ml and $71.9 - 109.7\%$, respectively. Apparent and total amylose content and WSV was $20.6 - 25.0\%$, $26.1 - 32.4\%$ and 9.0 - 16.9 ml, respectively. There were highly significant correlations between MST and AWRC (r=0.592, P<0.001), but Korean wheats showed no significant difference in protein content, amylose content and small-sample methods. In the biochemical markers, Korean wheats contained all three GBSS encoded by Wx loci, except for Suwon 252. Korean wheats showed the high frequency ($58.1\%$) of 1Dx2.2 + 1Dy12 subunits of HMW-GS. Friabilin band was present in 46 lines ($62.2\%$) and absent in 28 lines ($37.8\%$). Friabilin-absence lines showed the higher MST (14.9 ml) and AWRC ($92.1\%$) value than friabilin-presence lines (8.5 ml and $82.4\%$, respectively).

Chemical Composition and Quality of Persimmon Peels According to Cultivars (품종별 감피의 화학적 성분 특성)

  • Kim, Suk-Kyung;Lim, Jung-Hyung;Kim, Young-Chan;Kim, Mi-Yeon;Lee, Byung-Woo;Chung, Shin-Kyo
    • Applied Biological Chemistry
    • /
    • v.48 no.1
    • /
    • pp.70-76
    • /
    • 2005
  • Approximate composition and physicochemical properties of 7 cultivars of persimmon peel, by product of dried-persimmon, were examined. The content of crude fiber were different according to cultivars. Glucose, fructose and sucrose were isolated by HPLC; also, myristic, palmitic, palmitoleic, oleic and linolenic acid were the major fatty acids in persimmon peel. Total and free amino acid were 241.32-371.45 mg/100 g and 3.69-28.31 mg/100 g, respectively; also, aspartic and glutamic acid were the predominant amino acids, reaching a level between 19.6 and 24.8% of total amino acids. Insoluble dietary fiber content(34.89-50.76 g/100 g) was remarkably higher than soluble dietary fiber (2.44-7.09 g/100 g). Total carotenoids were in the range of 179.4-340.6 mg/100 g, and total phenolic compounds ranged from 44.07-196.98 mg/100 g, showing differences between cultivars.