• Title/Summary/Keyword: method detection limit

Search Result 1,352, Processing Time 0.028 seconds

Real-Time Voltammetric Assay of Lead Ion in Biological Cell Systems

  • Ly, Suw-Young
    • Toxicological Research
    • /
    • v.25 no.4
    • /
    • pp.231-235
    • /
    • 2009
  • Trace lead detection for cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry was performed using mercury immobilized onto a carbon nanotube electrode (HNPE). Using the characteristics of mercury and the catalytic carbon nanotube structure, a modified technique, the $0.45{\mu}g/l$ detection limit of lead ion was attained. The developed method can be applied to pond water, fish tissue, plant tissue, and in vivo direct assay.

Modified Glassy Carbon Electrode with Silver Nanoparticles/Polyaniline/Reduced Graphene Oxide Nanocomposite for the Simultaneous Determination of Biocompounds in Biological Fluids

  • Ghanbari, Kh.;Moloudi, M.;Bonyadi, S.
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.361-372
    • /
    • 2019
  • The silver nanoparticles/polyaniline/reduced graphene oxide nanocomposite modified glassy carbon electrode (Ag/PANI/RGO/GCE) was prepared by the electrochemical method. The Ag/PANI/RGO nanocomposite was characterized by transmission electron microscopy (TEM), field emission scanning electron microscopy (FE-SEM), Raman spectroscopy, X-ray diffraction (XRD), and electrochemical impedance spectroscopy (ESI). Two electrochemical techniques namely differential pulse voltammetry (DPV) and cyclic voltammetry (CV) were used to the electrochemical behaviors investigation of ascorbic acid (AA), dopamine (DA), and uric acid (UA). The Ag/PANI/RGO/GCE exhibited remarkable electrocatalytic activity towards the oxidation reaction of AA, DA, and UA in Britton-Robinson (BR) solution (pH=4.0). Under the optimal conditions, the determinations of AA, DA, and UA were accomplished using DPV. AA-DA and DA-UA peak potential separations were 130 and 180 mV, respectively. For simultaneous detection, the linear response ranges were in the two concentration ranges of 0.05-0.8 mM and 2.0-16.0 mM with detection limit 0.412 μM (S/N = 3) for AA, 0.7-90.0 μM and 90.0-1000.0 μM with detection limit 0.023 μM (S/N = 3) for DA, and 0.8-70.0 μM and 70.0-1000.0 μM with detection limit 0.050 μM (S/N = 3) for UA. This modified electrode showed good sensitivity, selectivity, and stability with applied to determine AA, DA, and UA in human urine and drug.

Simultaneous Analysis of 17 Organophosphorous Pesticides in Blood by Automated Head Space-SPME GC/MS (HS-SPME-GC/MS에 의한 혈액중 17종 유기인계 농약의 동시분석법)

  • Rhee, Jong-Sook;Jung, Jin-Mi;Lee, Han-Sun;Yeom, Hye-Sun;Lee, Sang-Ki;Park, Yoo-Sin;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.54 no.6
    • /
    • pp.429-440
    • /
    • 2010
  • HS-SPME-GC/MS was studied and optimized for the determination of 17 orgarnophosphorous pesiticides (OPPs: chlorpyrifos, chlorpyrifos-methyl, demeton-s-methyl, diazinon, dimethoate, EPN, fenitrothion, fenthion, malathion, methidathion, monocrotophos, parathion, phenthoate, phosphamidon, sulfotep, terbufos, triazophos) in blood. Optimum SPME parameters were selected: choice of SPME fiber (85 ${\mu}m$ polyacrylate), pH effect (0.5 N HCl), salt effect ($Na_2SO_4$, 0.2 g; 20%), headspace incubation temperature ($80^{\circ}C$), headspace incubation time (1 min), headspace adsorption time (30 min) and GC desorption time (2 min). These parameters were optimized using HS-SPME autosampler coupled with gas chromatography-mass spectrometry (GC-MS). Method validation was carried out in terms of linearity, limit of detection (LOD), limit of quantitation (LOQ) and recovery in blood. The assay was linear over 0.5~5.0 mg/l ($r^2$=0.955~1.000). Limit of detection (LOD) and limit of quantitation (LOQ) in blood were determined 0.03~0.3 mg/l (S/N=3) and 0.1~1.1 mg/l (S/N=10), respectively. Relative recovery with 0.5, 1 and 5 mg/l (in blood) were 90.8%, 98.5% and 94.1%, respectively. This method will be applied to the determination of the orgarnophosphorous pesticides in postmortem blood. The proposed protocol can be an attractive alternative to be used in routine toxicological analysis.

Establishment of the Analytical Method for Residual Pharmaceuticals in Raw Water Using Online Sample Preparation and High Resolution Orbitrap LC/ESI-MS (온라인 자동화 시료 전처리 및 HR Orbitrap LC/ESI-MS를 이용한 환경시료 중 잔류 의약물질 분석방법 확립)

  • Hwang, Yoonjung;Sin, Sanghee;Park, Jongsuk
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.3
    • /
    • pp.409-419
    • /
    • 2013
  • In this study, the analytical method for 27 residual pharmaceuticals in raw water was developed. Online sample preconcentration/extraction and analysis with high resolution Orbitrap mass spectrometry (LC-ESI/Orbitrap MS) were performed. The calibration curves showed good linearities (above $r^2$ = 0.998) in the range of 5 ~ 1,000 ng/L. The method detection limit and the limit of quantification were 1.1 ~ 10.0 ng/L and 3.4 ~ 31.7 ng/L, respectively. Recoveries of the target compounds were between 70.1% and 115.8% (except cefadroxil, cefradine, vancomycin, and iopromide (50.2 ~ 67.0%)). The optimized analytical method can be useful to determine the residual pharmaceuticals in raw water.

Comparison of Extraction Procedures for the Determination of Capsaicinoids in Peppers

  • Jeon, Geonuk;Lee, Jun-Soo
    • Food Science and Biotechnology
    • /
    • v.18 no.6
    • /
    • pp.1515-1518
    • /
    • 2009
  • The objective of this study was to compare 3 extraction methods including, solid phase extraction (SPE), acetonitrile extraction, and methanol extraction, for their usefulness as extraction methods to determine capsaicinoids. The determination of capsaicinoids in the extracts was carried out on a reverse-phased high performance liquid chromatography (HPLC) using a fluorescence detector. Three extraction methods, i.e., SPE, acetonitrile extraction, and methanol extraction were compared for the quantification of capsaicinoids using raw peppers and pepper powder. The highest analytical values were observed using methanol extraction and the lowest values using SPE. Also, the analytical method validation parameters such as accuracy, precision, limit of detection, limit of quantitation, and specificity were calculated to ensure the method's validity. This method provides a fast and accurate approach for the determination of capsaicinoids in peppers.

The moving object detection for moving picture with gaussian noise (프레임간 가우시안 잡음이 있는 동영상에서의 움직임 객체 검출)

  • Kim, dong-woo;Song, young-jun;Kim, ae-kyeong;Ahn, jae-hyeong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.839-842
    • /
    • 2009
  • It is used to differential image for moving object detection in general. But it is difficult to detect the accurate detection which uses differential image between frames. In this paper, the proposed method overcome the noise that is generated by camera, grabber card, or weather condition. It extract to moving big object such as human or vehicle. The proposed method process morphological filtering and binary for the image with noise, reduce error. We are expect to apply to a real-time moving object detection system at fog condition, pass the limit of the object detection method using the differential image.

  • PDF

Defect Detection in Laser Welding Using Multidimensional Discretization and Event-Codification (Multidimensional Discretization과 Event-Codification 기법을 이용한 레이저 용접 불량 검출)

  • Baek, Su Jeong;Oh, Rocku;Kim, Duck Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.11
    • /
    • pp.989-995
    • /
    • 2015
  • In the literature, various stochastic anomaly detection methods, such as limit checking and PCA-based approaches, have been applied to weld defect detection. However, it is still a challenge to identify meaningful defect patterns from very limited sensor signals of laser welding, characterized by intermittent, discontinuous, very short, and non-stationary random signals. In order to effectively analyze the physical characteristics of laser weld signals: plasma intensity, weld pool temperature, and back reflection, we first transform the raw data of laser weld signals into the form of event logs. This is done by multidimensional discretization and event-codification, after which the event logs are decoded to extract weld defect patterns by $Na{\ddot{i}}ve$ Bayes classifier. The performance of the proposed method is examined in comparison with the commercial solution of PRECITEC's LWM$^{TM}$ and the most recent PCA-based detection method. The results show higher performance of the proposed method in terms of sensitivity (1.00) and specificity (0.98).

Determination of trace bromate in various water samples by direct-injection ion chromatography and UV/Visible detection using post-column reaction with triiodide

  • Kim, Jungrae;Sul, Hyewon;Song, Jung-Min;Kim, Geon-Yoon;Kang, Chang-Hee
    • Analytical Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.42-48
    • /
    • 2020
  • Bromate is a disinfection by-product generated mainly from the oxidation of bromide during the ozonation and disinfection process in order to remove pathogenic microorganism of drinking water, and classified as a possible human carcinogen by International Agency for Research of Cancer (IARC) and World Health Organization (WHO). For the purpose of determining the trace level concentration of bromate, several sensitive techniques are applied mostly based on suppressed conductivity detection and UV/Visible detection after postcolumn reaction (PCR). In this study, the suppressed conductivity detection method and the PCR-UV/Visible detection method through the triiodide reaction were compared to analyze the trace bromate in water samples and estimated for the availability of these analytical methods. In addtion, the state-of-the-art techniques was applied for the determination of trace level bromate in various water matrices, i.e., soft drinking water, hard drinking water, mineral water, swimming pool water, and raw water. In comparison of two analytical methods, it was found that the conductivity detection had the suitable advantage to simultaneously analyze bromate and inorganic anions, however, the bromate might not be precisely quantified due to the matrix effect especially by chloride ion. On the other hand, the trace bromate was analyzed effectively by the method of PCR-UV/Visible detection through triiodide reaction to satisfactorily minimize the matrix interference of chloride ion in various water samples, showing the good linearity and reproducibility. Furthermore, the method detection limit (MDL) and recovery were 0.161 ㎍/L and 101.0-108.1 %, respectively, with a better availability compared to conductivity detection.

Comparison of isoButoxycarbonyl derivatives, tert.-butyldimethylsilyl derivatives, with US EPA Method in the sensitivity of Alkylphenols, Chlorophenols, and Bisphenol A Potential field-screening applications of GC/MS-SIM (기체 크로마토그래피/질량분석기를 이용한 field-screening 적용을 위한 알킬페놀류, 클로로페놀류 및 비스페놀 A의 isoBOC 유도체, TBDMS 유도체와 US EPA 방법의 비교)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.196-213
    • /
    • 2002
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode followed by three work-up methods for comparison; EPA method, isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in water samples were extracted with dichloromethane. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1~109.9% (EPA method) and 90.3~126.6% (isoBOC derivatization and TBDMS derivatization), respectively. The method detection limit of bisphenol A for SIM were 0.732 ${\mu}g/{\ell}$ (EPA method), 0.002 ${\mu}g/{\ell}$ (isoBOC derivatization) and 0.021 ${\mu}g/{\ell}$ (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755~0.9981 (isoBOC derivatization), and 0.9908~0.9996 (TBDMS derivatization). When these methods were applied to treated wastewater sample from a polyethylene plant, the concentrations of 11 phenols were below the method detection limit.

Evaluation of Various Real-Time Reverse Transcription Quantitative PCR Assays for Norovirus Detection

  • Yoo, Ju Eun;Lee, Cheonghoon;Park, SungJun;Ko, GwangPyo
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.4
    • /
    • pp.816-824
    • /
    • 2017
  • Human noroviruses are widespread and contagious viruses causing nonbacterial gastroenteritis. Real-time reverse transcription quantitative PCR (real-time RT-qPCR) is currently the gold standard for the sensitive and accurate detection of these pathogens and serves as a critical tool in outbreak prevention and control. Different surveillance teams, however, may use different assays, and variability in specimen conditions may lead to disagreement in results. Furthermore, the norovirus genome is highly variable and continuously evolving. These issues necessitate the re-examination of the real-time RT-qPCR's robustness in the context of accurate detection as well as the investigation of practical strategies to enhance assay performance. Four widely referenced real-time RT-qPCR assays (Assays A-D) were simultaneously performed to evaluate characteristics such as PCR efficiency, detection limit, and sensitivity and specificity with RT-PCR, and to assess the most accurate method for detecting norovirus genogroups I and II. Overall, Assay D was evaluated to be the most precise and accurate assay in this study. A ZEN internal quencher, which decreases nonspecific fluorescence during the PCR, was added to Assay D's probe, which further improved the assay performance. This study compared several detection assays for noroviruses, and an improvement strategy based on such comparisons provided useful characterizations of a highly optimized real-time RT-qPCR assay for norovirus detection.