• Title/Summary/Keyword: meter data

Search Result 844, Processing Time 0.03 seconds

Deep-sea floor exploration in the East Sea using ROV HEMIRE (무인잠수정 해미래 활용 동해 저서환경 심해탐사)

  • Min, Won-Gi;Kim, Jonguk;Kim, Woong-Seo;Kim, Dong-Sung;Lee, Pan-Mook;Kang, Jung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.222-230
    • /
    • 2016
  • HEMIRE is a 6,000-meter-class remotely operated vehicle (ROV) that has been developed for observation and sampling of objects of interest on the deep seabed. We first carried out deep-seabed exploration around the slopes of the Hupo Bank and the Ulleung Basin in the East Sea in June 2015. Over two weeks, a total of 10 dives were made from a support ship, the R/V Onnuri, at eight stations with water depth ranging between 194 and 2,080 m. The dive times ranged from 1 to 6 hours, depending on the operating conditions. We obtained the following results: 1) video images of the deep seafloor; 2) red snow crab density data (a major fishery resource) and inventories of deep-sea fauna, including an unrecorded organism; 3) specific topographies such as canyons slopes; 4) an undisturbed sediment core obtained using a push corer; and 5) observations of the seabed surface covered with discarded anthropogenic waste material.

A Study of Cosmetic Sustainability Evaluation of Powder Base Make-up Products (파우더 베이스 메이크업 제품의 지속성 평가 방법 연구)

  • Lee, Sang Gil;Kim, Ki Jung;Kim, Young Ho;Pyo, Hyeong Bae;Lee, Dong Kyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.3
    • /
    • pp.209-218
    • /
    • 2015
  • Once powder base makeup products are applied to the skin, the products are formed a film and attached on the skin for 8 to 12 hours. The makeup film is deformed by secretions such as sweat and sebum secreted from the skin. Thus, durability of the film is an important quality factor in the makeup and its evaluation is also important. In this study, characteristics of the semi-finished powder products such as water absorption, oil absorption, water repellent and oil repellent were evaluated in a number of ways. Also, simple methods, which are not affected by evaluation conditions such as a difference between sweat and sebum secretion, temperature and humidity, were examined to predict the durability of the products. We measured water absorption, oil absorption, water repellent and oil-repellent properties of semifinished product by tablet, capillary and dipping method and then compared with the data of color difference meter and ROBO skin analyzer. Results showed that the durability of powder base makeup products was associated with more oil absorption and water-repellent characteristics than water absorption and oil-repellent. Oil absorption characteristics by tablet and capillary method and water-repellent characteristics by dipping method provides a simple and quick method to precdict the durability of the makeup products.

A study on magnetron source design and characteristics for super high rate deposition (초고속 증착용 마그네트론원 설계 및 특성에 관한 연구)

  • 빈진호;남경훈;한전건
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.06a
    • /
    • pp.8-8
    • /
    • 2001
  • 초고속 증착은 짧은 시간에 박막 형성을 가능하게 하므로 window glass 코팅등의 대면적 코팅에 있어서 비용을 절감 시키고, 대량생산을 가능하게 만들기 때문에 관심이 집중되고 있다. 고속증착 공정으로는 high current arc, laser arc, hollow cathode discharge ion plating 그리고 마그네트론 스퍼터링법 등이 있다. 특별히 마그네트론 스퍼터링법은 3m이상의 넓이에 코팅을 할때 두께가 매우 균일하며, 증착율은 evaporation 공정에 비해 경제적, 기능적인 면에서 효율적이다. 그리고 증착된 박막은 매우 조밀하고 좋은 밀착력을 갖고 있으며, 고융점 금속을 포함하여 금속 합금 및 혼합물의 비율을 조정 및 금속 산화물, 질화물, 탄화물 등과 같은 금속의 증착도 stoichiometry를 조정하여 박막을 합성 시키는데 있어서 효과적이다. 이러한 초고속 증착을 만들기 위한 마그네트론 스퍼터링법의 요건은 마그네트론 원이 높은 타켓 power density를 가져야 하며, 타켓에서 효율적으로 플라즈마를 구속하여 스퍼터 되는 이온의 양을 최대화 시킬 수 있어 한다. 따라서 본 실험에서는 초고속 증착을 위해서 직경 50mm 타켓의 UBM magnetron원을 설계 제작하였다. 고밀도의 플라즈마를 형성시키기 위해서, Poisson simulation c code를 이용하여 자기장의 방향, 세기 및 밀도를 측정 하였고, 자기장 측정기(Gauss meter)를 이용하여 실제 자장을 측정 비교 분석하였다. 상기의 data를 바탕으로 여러 형상의 마그네트론원을 설계, 제작하였고. 마그네트론 원의 특성 분석을 위해 I-V 방전 특성을 평가하였고 substrate ion current density와 박막의 증착율을 측정하였다.duty-on 시간의 증가에 따라 $Cr_2N$ 상의 형성이 점점 많아져 80% duty-on 시간 경우에는 거의 CrN과 $Cr_2N$ 상이 공존하는 것으로 나타났다. 또한 duty-on 시간이 증가할수록 회절피크의 세기가 증가하여 결정화가 더 많이 진행되어짐을 알 수 있었다. 마찬가지로 바이어스 펄스이 주파수에 다른 결정성의 변화도 펄스의 주파수가 증가할수록 박막이 결정성이 좋아지고 $Cr_2N$ 상이 쉽게 형성되었다. 증착 진공도에 따른 결정성은 상대적으로 질소의 농도가 높은 낮은 진공도에서는 CrN 상이 주로 형성되었으며, 반대로 높은 진공도에서는 $Cr_2N$ 상이 많이 만들어졌다. 즉 $1.3{\times}10^{-2}Torr$의 증착 진공도에서는 CrN 상만이 보이는 반면 $9.0{\tiems}1-^{-2}Torr$ 진공도에서부터 $Cr_2N$ 상이 형성되기 시작하여 $5.0{\tiems}10^{-2}Torr$ 진공도에서는 두개의 상이 혼재되어 있음을 알 수 있었다. 박막의 내마모성을 조사한 결과 CrN 박막의 마찰 계수는 초기에 급격하게 증가한 후 0.5에서 0.6 사이의 값으로 큰 변화를 보이지 않았으며, $Cr_2N$ 박막도 비슷한 거동을 보였다.차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$

  • PDF

Relationship Between the Groundwater Resistivity and NaCl Equivalent Salinity in Western and Southern Coastal Areas, Korea (국내 서.남해 해안지역 지하수의 전기비저항과 등가 NaCl 염분도와의 관계)

  • Hwang, Se-Ho;Park, Kwon-Gyu;Shin, Je-Hyun;Lee, Sang-Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.361-368
    • /
    • 2007
  • In this paper, we suggested the relationship between resistivity of coastal groundwater and NaCl equivalent salinity for the quantitative interpretation the results of surface/borehole resistivity and electromagnetic data. 38 groundwater samples having electrical conductivity higher than about 1,000 ${\mu}S/cm$ were analyzed to derive the empirical relationship between groundwater resistivity and NaCl equivalent salinity. We used Schlumberger chart GEN-8 to convert ion concentration from hydrochemical analysis to the equivalent NaCl salinity, and the portable meter to measure the in situ electrical conductivity of groundwater samples. From the hydrochemical analysis, relationship between the groundwater resistivity $(R_w)$ and equivalent NaCl salinity (Eq_NaCl) is expressed as Eq_NaCl=$5935.3551{\times}R_w^{-1.0993}$, and relationship between the groundwater electrical conductivity (EC) and total dissolved solids (TDS) is expressed as TDS=0.721*EC. We believe these relationships are very useful to assess the seawater intrusion in western and southern coastal area.

Study on the Measurement of TMP Pumping Speed (터보분자펌프(TMP) 배기속도 측정에 관한 고찰)

  • Kang, S.B.;Shin, J.H.;Cha, D.J.;Koh, D.Y.;Cheung, W.S.;Lim, J.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.4
    • /
    • pp.249-255
    • /
    • 2010
  • Methods of the characteristics evaluation of turbo-molecular pumps (TMP) are well-defined in the international measurement standards such as ISO, PNEUROP, DIN, JIS, and AVS. The Vacuum Center in the Korea Research Institute of Standards and Science (KRISS) has recently designed, constructed, and established the integrated characteristics evaluation system of TMPs based on the international documents by continuously pursuing and acquiring the reliable international credibility through measurement perfection. The measurement of TMP pumping speed is normally performed with the throughput and orifice methods dependent on the mass flow regions. However, in the UHV range of the molecular flow region, the high uncertainties of the gauges, mass flow rates, and conductance are too critical to precisely accumulate reliable data. In order to solve the uncertainty problems of pumping speeds in the UHV range, we introduced a SRG with 1% accuracy and a constant volume flow meter (CVFM) to measure the finite mass flow rates down to $10^{-1}$ Pa-L/s with 3% uncertainty for the throughput method. In this way we have performed the measurement of pumping speed down to $10^{-4}$ Pa with an uncertainty of less than 6% for a 1000 L/s TMP. In this article we suggest that the CVFM has an ability to measure the conductance of the orifice experimentally with flowing the known mass through the orifice chambers, so that we may overcome the discontinuity problem encountering during introducing two measurement methods in one pumping speed evaluation sequence.

Assessment for Inhalation Exposure to Trihalomethanes (THMs) and Chroline and Efficiency of Ventilation for an Indoor Swimming Pool (일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가)

  • Park, Hae-Dong;Park, Hyun-Hee;Shin, Jung-Ah;Kim, Tae-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.5
    • /
    • pp.402-410
    • /
    • 2010
  • The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.

The Comparison of Color Perception between Korean and American undergrauates (한미 대학생의 색지각에 대한 비교연구)

  • 안옥희;박진호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.10-16
    • /
    • 2003
  • The purpose of this study was to investigate the scope of standard color perception for Americans and to compare the differences in color perception between Korean and American undergraduates. Sixty male and fifty-one female American undergraduates were selected as a random sample. Color perception was tested with the naked eyes. Minolta Chroma Meter CR 300 was used for physical measurement of the color. Based on the objective of this study and the data generated the following results were drawn: 1) We found no distinctive difference in color perception by different eye colors. 2) Color perception of American undergraduates is largely classified into four different groups: simple group includes Yellow, Green, Blue, White, Gray, and Black, X(-axis)group includes Yellow Red, Y(-axis)group includes Blue Green, Purple, complex group includes Yellow Red, Purple Blue. 3) The differences in color perception between the two undergraduate groups were found to be significant with four colors: Yellow Red, Green, Blue, and Purple. 4) There is a wide difference between the values of standard color and inn percept color. When undergraduates in both countries were compared, it turned out that Korean students were more accurate than Americans in color perception. 5) American students perceived Red, Yellow, and Green colors relatively correctly, but showed an extremely low degree of accuracy in Blue and Purple Blue color perception.

Development of a Fall-prevention Exercise Program for Elderly People in Community (지역사회 노인낙상예방을 위한 운동 프로그램 개발 및 예비조사)

  • Lee, Seon Heui;Bak, Won-Sook;Shin, Gyeyoung;Lee, Kyung-Sook;Lim, Kyung-Choon;Kim, Minju;Lee, Inok;Choi, Hee Kwon;Park, Mi Sung;Bae, Sun Hyoung;Yu, Jae Sun;Chung, Jae Hee;Youn, In Sook;Eun, Young;Choi, Mi-Kyung
    • Journal of muscle and joint health
    • /
    • v.27 no.1
    • /
    • pp.61-70
    • /
    • 2020
  • Purpose: The purpose of this study was to develop a new fall-prevention exercise intervention for the community-dwelling elderly and to examine the effects of program. Methods: A total of 7 older adults were participated in a 10-week fall-prevention exercise intervention (1 day per a week in community centers, 2 days per a week in a home). The exercise program consisted of warming-up, extension exercises, muscle strength exercises, balance exercises, and finishing exercise. Data were collected before the exercise and after 10 weeks of exercise. In this study, muscle strength of lower limbs was measured by 10 times of standing up and sitting on a chair. Static balance was measured by one-leg standing, and dynamic balance was measured by 6 meter walking. Results: After a 10-week exercise program, muscle strength of lower limbs (t=4.18, p<.05), statical balance were significantly improved (left leg, t=-3.11, p<.05; right leg, t=-4.56, p<.05). Seven of 11 items measuring fear of falls were significantly decreased (p<.05), and dynamic balance tended to be improved (p=.117). Conclusion: This result suggests that evidence-based, fall-prevention exercise program can improve muscle strength, static and dynamic balance, and fear of falling in the community living elderly.

A Study on the Effective Fire and Smoke Control in Semi-Transverse Ventilation (균일배기 환기방식에서의 배연특성에 관한 연구)

  • Jeon, Yong-Han;Kim, Jong-Yoon;Seo, Young-Ho;Yoo, Oh-Ji;Han, Sang-Pil
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.90-94
    • /
    • 2010
  • In this study it is intended to review the moving characteristics of smoke by performing visualization simulation for the calculation of the optimal smoke exhaust air volume in case a fire occurs in tunnels where transverse ventilation is applied, and to obtain basic data necessary for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions under various conditions. As a result of this study, if it was assumed 0 critical velocity in the tunnel, the smoke exhaust air volume was limited within 250 meter in the road-tunnel disaster prevention indicator and the exhaust efficiency was from 55.1% to 95.8% in the result of this study. If the wind velocity is in the tunnel, the exhaust rate intends to increase rapidly and the exhaust efficiency is decreased. In addition, if the wind velocity is increased, the exhaust rate should be increased in compared with the generation rate of smoke in maximum 1.8 or 1.04 times. In this study, when the wind velocity is in the tunnel, the limited exhaust rate is $84m^3/s{\cdot}250m$. And if it was assumed 1.75 m/s critical velocity in the tunnel, the exhaust rate would be defined $393m^3/s{\cdot}250m$($Q_E$ = 80 + 5Ar).

Sod Production in South Korea (한국의 잔디 생산 현황)

  • Choi, Joon-Soo;Yang, Geun-Mo
    • Asian Journal of Turfgrass Science
    • /
    • v.20 no.2
    • /
    • pp.237-251
    • /
    • 2006
  • This study was carried out to provide data on current sod production in South Korea. Fifteen items were surveyed including production acreage, species and cultivars, experience on farming, production cost and the others during April to October in 2006. To estimate production acreage, 73 turfgrass growers were interviewed. Estimated acreage for turfgrass production was 2,947 ha. Acreages by province were 1,417 ha in Jeollanam-do(48%), 442 ha in Jeollabuk-do(14.9%), 344 ha in Gyeonggi-do(11.6%), 248 ha in Gyeongsangnam-do(8.4%), and 240 ha in Chungcheongnam-do(8.1%), respectively. The major sod producing regions were Jangseong-gun, Hampyeong-gun, Yeonggwang-gun, Gochang-gun, Sacheon city, Iksan city, Yeoju city, Yeoncheon-gun. Percentage of turf growers over 50 years old was 72.4 percent, which means production was carried out mainly by old farmers. Grower's career over 10 years was 84.8%. Cultivated species and varieties were 'Junggi'(55.5%) of fine-textured Korean lawngrass, common Korean lawngrass(37.4%), Kentucky bluegrass(3.8%), and new zoysiagrass cultivars(0.1%), respectively. Sod size were variable. Sod size of $18{\times}18cm $ was 43.5 percent. Sales route was mainly through sod distributor(40.5%). Sod producing cost was $2,160{\sim}2,730$ won per square meter at Jeolla-do areas.