• Title/Summary/Keyword: medical equipment

Search Result 1,275, Processing Time 0.025 seconds

A Study on Glomerular Filtration Rate Comparisons between Gates Method and Modified Gates Method used in Dynamic Renal Scintigraphy (동적 신장 신티그래피 검사 시 사용되는 Gates 법과 Modified Gates 법의 사구체 여과율 비교에 관한 고찰)

  • Ham, Jun-Cheol;Bahn, Young-Kag;Park, Min-Soo;Cho, Seok-Won;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.96-101
    • /
    • 2012
  • Purpose: Glomerular filtration rate is an important index for assessment of renal function, early discovery of renal disease, and progress observation of chronic renal disease patients. In the present study, the objective is to conduct a comparative analysis of differences between Gates and Modified Gates method in dynamic renal scintigraphy based on MDRD (Modification of Diet Renal Disease) formula using blood collection. Materials and Methods: Renal scintigraphy was performed for 45 patients who visited our hospital between November 2010 and August 2011. For 20 patients of those tested, glomerular filtration rates from Gates method and MDRD formula using AGUS equipment, were compared. For the other 20 patients, glomerular filtration rates from Modified Gates method and MDRD formula using INFINIA equipment. Finally, Gates and Modified Gates method were compared for 5 patients who indicated no change in glomerular filtration rates from MDRD formula during progress observation. Results: Glomerular filtration rates from both Gates and Modified Gates method showed a high correlation with those from MDRD formula ($p$<0.01, r=0.903, r=0.867), with a paired difference mean for Gates method of $2.05{\pm}2.54mL/min/1.73m$, and that for Modified Gates method of $25.2{\pm}3.71mL/min/1.73m$. Finally, the values for Gates method and those for Modified Gates method showed a high correlation for the five patients ($p$<0.05, r=0.949), with a paired difference mean of $20.4{\pm}8.84mL/min/1.73m$. Conclusion: Glomerular filtration rates from Gates method, Modified Gates method and MDRD formula showed mutually high correlations. If the tests are performed with recognition for the correlations between Gates and Modified Gates method used in a dynamic renal scintigraphy, then an accurate assessment of renal function is considered possible with an improved diagnostic ability.

  • PDF

Reduction of Injection Dose in 18F-FDG Fusion PET (PET-CT 검사에서 18F-FDG 투여량 감소에 대한 고찰)

  • Kim, Jong-Pil;Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.17-21
    • /
    • 2014
  • Purpose With the recent rise of social issue regarding radiation exposure, attention to medical radiation use has been placed under a great spotlight. During PET-CT examination, generally about 40% more of $^{18}F$-FDG is used than EANM recommendation. While maintaining the diagnostic test result, we hope to find optimal injection dose to minimize the $^{18}F$-FDG in patients by utilizing the latest PET-CT scanner which is equiped with the newest technology. Materials and Methods During this experiment, the Biograph Truepoint 40 (siemens, USA) installed in 2007 and mCT 64 (siemens, USA) installed in 2011 were used and evaluated NECR (noise-equivalent counting rate) by using a scatter phantom. For the image quality evaluation of each scanner, we injected 3.7, 4.44 and 5.18 MBq/kg of $^{18}F$-FDG in NEMA IEC Body Phantom and also evaluated SNR between two scanners by using the data acquired at 60, 70, 80, 90, 100, 110 and 120 sec per bed. For the clinical evaluation, actual data of patients who were injected $^{18}F$-FDG 3.7, 4.44, 5.18 MBq/kg were used to compare SNR and draw a final result. Results As a result, mCT 64 peak NECR value was 1.65e+005, which is 10% higher than Turepoint 40. SNR values using the IEC body phantom was 17.9%, 17.4% and 17.1% higher in $^{18}F$-FDG 3.7 MBq/kg, 4.44 MBq/kg and 5.18 MBq/kg. In clinical patients, SNR values of the image mCT 64 was 16.5, which is 25% higher than Turepoint 40 scanner. Conclusion To draw a conclusion from the test result of this experiment, the same quality of SNR could be attained even with 10% reduced injection dose, if when the duration is extended by 10 sec/bed. This optimal result was possible due to enhanced equipment. The NECR (one of the equipment's performance assessment criteria for the scanner) increased by 10% and the SNR (one of the image quality assessment criteria) also increased by 17.5%. Therefore, we can expect to reduce the injection dose without deterioration of image quality. In consequence, it will also help to decrease the patient's anxiety of the radiation exposure.

  • PDF

Adequacy of Source to Image Receptor Distance with Chest Postero-Anterior Projection in Digital Radiology System (디지털방사선 환경에서 흉부 후-전 방향 검사 시 초점과 영상수용체간 거리의 적절성)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;You, In-Gyu;Jung, Hong-Ryang;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.135-142
    • /
    • 2016
  • The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7~3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6~2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6~8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6~8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment.

Norm-referenced criteria for strength of the elbow joint for the korean high school baseball players using the isokinetic equipment: (Focusing on seoul and gyeonggi-do) (등속성 장비를 이용하여 한국고교야구선수 주관절 근력 평가기준치 설정: (서울 및 경기도 중심으로))

  • Kim, Su-Hyun;Lee, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.442-447
    • /
    • 2017
  • The purpose of this study was to establish norm-referenced criteria for the isokinetic strength of the elbow joint in Korean high school baseball players. Two hundred and one high school baseball players participated in this study, none of whom had any medical problem with their upper limbs. The elbow flexion/extension test was conducted four times at a speed of $60^{\circ}/sec$. The HUMAC NORM (CSMI, USA) system was used to obtain the values of the peak torque and peak torque per body weight. The results were presented as norm-referenced criterion valuesusing the 5-point scale of Cajori which consists of five stages (6.06%, 24.17%, 38.30%, 24.17%, and 6.06%). In the results of this study, the peak torques of the elbow (flexor and extensor?) at an angular velocity of $60^{\circ}/sec$ were $37.88{\pm}8.14Nm$ and $44.59{\pm}11.79Nm$, and the peak torque per body weight of the elbow (flexor and extensor?) were $50.06{\pm}8.66Nm$ and $58.28{\pm}12.84Nm$, respectively. The reference values of the peak torque and peak torque per body weight of the elbow flexor and extensor were setat an angular velocity of $60^{\circ}/sec$. On the basis of the results analyzed in this study, the following conclusions were drawn. There is a lack of proper studies on the elbow joint strength, even though the most common injury in baseball players occurs in the elbow joint. Therefore, we need to establish a standard muscle strength in order to prevent elbow joint injuries and improve their performance. The criteria for the peak torque and peak torque per body weight established here in will provide useful information for high school baseball players, baseball coaches, athletic trainers and sports injury rehabilitation specialists in injury recovery and return to rehabilitation, which can beutilized as objective clinical assessment data.

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

The Average Glandular Dose in Mammography and Quality Control of the Equipment Status (유방촬영검사에서 평균유선선량과 장치의 품질관리 실태)

  • Jung, Hong-Ryang;Hwang, Su-Lyun;Ha, Bon-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.111-120
    • /
    • 2011
  • A purpose of study is to develop optimization and radiation dose exposure reference level by measuring actual radiation dose in condition of quality control of mammography equipment for 39 clinics. The result were as follows. First, we measured T-test separating radiology from general clinic. According to the test, mAs was measured at average 78.58 mAs; radiology at 80.16 mAs and general clinic at 77.22 mAs. And, kerma rate was measured at average 7.71 mGy/mR; radiology at 8.94 mGy/mR and general clinic at 6.66 mGy/mR. HVL was measured at average 0.42 mmAl; radiology at 0.40 mmAl and general clinic at 0.43 mmAl. Average glandular dose was measured at average 1.14 mGy; radiology at 1.09 mGy and general clinic at 1.19 mGy. Second, we measured value of mAs, HVL, processing method and so on dividing two groups. And, we compared and analyzed average value measured using T-test. As a result, there was significance level in SID(P<0.05). There was significance level in mAs(P<0.05). Because processor was measured at 1.00 mGy and CR at 1.17 mGy according to the processing method of radiology. Third, according to the correlation analysis, radiology had significance level between average glandular dose and mAs and general clinic had significance level between average glandular dose and SID(P<0.05). Forth, as a result of regression analysis, mAs affected 22.7%t of average glandular dose and SID affected 21.7% of average glandular dose, which had significance level(P<0.05). And, mAs affected 29.0% of average glandular dose in radiology and SID affected 29.1% of average glandular dose in general clinic, which was most influential.

A Study of on the Method to Select Manufacturing Activities Sensitive to Regional Characteristics by Analyzing the Locational Hierarchy (입지계층분석을 활용한 산업단지 유치 업종 결정에 관한 연구)

  • So, Jin-Kwang;Lee, Hyeon-Joo;Kim, Sun-Woo
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.559-568
    • /
    • 2011
  • This study aims at listing up those manufacturing activities sensitive to regional characteristics by analyzing locational hierarchy designed on the urban rank-size rule. This locational hierarchy by manufacturing activities is expected to provide a ground for the proper supply of an industrial complex. The analysis of the locational hierarchy by manufacturing activities can work as a method of observing the characteristics of the distribution of location for each economic activity by analyzing the trend in the change of manufacturing location. Consequently, it can be used to determine the appropriate manufacturing activities for the industrial complex of a particular region. Here, the locational hierarchy is analyzed depending on the base of the basic local government such as Gun(district level) and Si(city level), and manufacturing activities are categorized by Korea Standard Industry Code. Those activities demonstrating growth pattern are Manufacture of Electronic Equipment(KSIC 26), Manufacture of Medical Precision Optical Instruments Watch(KSIC 27), Manufacture of Motor Vehicles (KSIC 30, 31), etc. With proper infrastructures, these activities can be located everywhere. Those sectors on the decline pattern in the locational hierarchy can be summarized as Manufacture of Tobacco Products(KSIC 12), Manufacture of wearing apparel Fur Articles(KSIC 14), etc. Those sectors scattered widely in the locational hierarchy are Manufacture of Food Products(KSIC 10), Manufacture of Coke Petroleum Products(KSIC 19), Manufacture of Chemical Products(KSIC 20), Manufacture of Electronic Equipment(KSIC 26). These particular manufacturing activities can be operated in those regions in a sufficient supply of unskilled workers regardless of proper infrastructures. Those activities that have a tendency to reconcentrate on larger cities are Manufacture of Textiles(KSIC 13), Manufacture of Wearing Apparel Clothing Fur Articles(KSIC 14), Manufacture of Other Transport Equiptmen(KSIC 31). In most cases, these sectors tend to favor their existing agglomerated areas and concentrate around large cities. Therefore, it is inefficient to promote these sectors in small or medium-sized cities or underdeveloped regions. The establishment of developmental strategies of an industrial complex can gain greater competitiveness by observing such characteristics of the locational hierarchy.

Image Evaluation for Optimization of Radiological Protection in CBCT during Image-Guided Radiation Therapy (영상유도 방사선 치료 시 CBCT에서 방사선 방호최적화를 위한 영상평가)

  • Min-Ho Choi;Kyung-Wan Kim;Dong-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.305-314
    • /
    • 2023
  • With the development of medical technology and radiation treatment equipment, the frequency of high-precision radiation therapy such as intensity modulation radiation therapy has increased. Image-guided radiation therapy has become essential for radiation therapy in precise and complex treatment plans. In particular, with the introduction of imaging equipment for diagnosis in a linear accelerator, CBCT scanning became possible, which made it possible to calibrate and correct the patient's posture through 3D images. Although more precise reproduction of the patient's posture has become possible, the exposure dose delivered to the patient during the image acquisition process cannot be ignored. Radiation optimization is necessary in the field of radiation therapy, and efforts to reduce exposure are necessary. However, when acquiring 3D CBCT images by changing the imaging conditions to reduce exposure, there should be no image quality or artefacts that would make it impossible to align the patient's position. In this study, Rando phantom was used to scan and evaluate images for each shooting condition. The highest SNR was obtained at 100 kV 80 mA 25 ms F1 filter 180°. As the tube voltage and tube current increased, the noise decreased, and the bowtie filter showed the optimal effect at high tube current. Based on the actual scanned images, it was confirmed that patient alignment was possible under all imaging conditions, and that image-guided radiation therapy for patient alignment was possible under the condition of 70 kV 10 mA 20 ms F0 filter 180°, which showed the lowest SNR. In this study, image evaluation was conducted according to the imaging conditions, and low tube voltage, tube current, and small rotation angle scan are expected to be effective in reducing radiation exposure. Based on this, the patient's exposure dose should be kept as low as possible during CBCT imaging.

Effects of The Sub ROI Changes on Exposure Index (Sub ROI 변화가 노출지수에 미치는 영향)

  • Young-Cheol Joo;Dong-Hee Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1149-1155
    • /
    • 2023
  • This study aims to investigate the effect of changes in the Sub ROI on exposure index(EI) and to present indicators of changes in EI values that may occur when changing Sub ROI in clinical practice. This study was conducted on a subject of 20 cm of acrylic for a setting similar to abdominal radiography, and the specifications of one acrylic sheet is 20 × 20 × 5 cm. The survey conditions were the same as 80 kVp , 320 mA, 25 ms, SID 110 cm and the Sub ROI obtained 30 images for each type using five types provided by the equipment company. The EI value provided by the equipment and entrance skin exposure(ESE) were compared and analyzed. The mean value of EI according to the change in Sub ROI was 101.18±0.27 for LS, 106.57±0.31 for AEC, 107.74±0.39 for VR, 107.90±0.38 for HR, and 109.72±0.32 for SS (p<0.01). The average value of ESE by sub ROI type (LS, AEC, VR, HR, SS) was measured to be 476.45±1.71 μGy, 476.92±1.48 μGy, 476.14±2.30 μGy, 475.61±1.96 μGy, and 477.14±1.46 μGy, with statistically significant differences (p<0.01). As a result of this study, the EI according to the sub ROI type is based on LS(109.72), which represents the minimum value. AEC increased 5.3%, VR increased 6.4%, HR increased 6.6%, SS increased 8.4%, and overall, increased by about 5.3%. As for the average value of ESE, HR(475.61 μGy)type showed the minimum value, and based on this, AEC increased 0.27%, VR increased 0.11%, LS increased 0.17%, SS increased 0.32%, and overall, increased by about 0.17%.

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF