• 제목/요약/키워드: medical electrical equipment

검색결과 110건 처리시간 0.026초

반사형 소자를 이용한 시료의 컬러정보 및 농도분석 (An Optical Technique for Concentration Measurement by Color Analysis)

  • 이태희;김지선;정구인;최주현;오한별;김아희;정현철;조영빈;전재훈
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1121-1127
    • /
    • 2014
  • Many studies have been done to measure and analyze color for various purposes. Visual assessment has lack of objectivity and the equipment for color measurement is very expensive. In this study, we developed a device for quantitative analysis of the color using optical elements. With the color sensor, the ratio of RGB was calculated by measuring the light intensity that is reflected from an object. Inverse transformation of optical signal was performed to detect the color density. The suggested color analyzer can detect color information as well as sample concentration. Results of this study are expected to be used in various medical fields such as pH indicator and urine analysis.

북한의 핵전자기파(NEMP)탄 개발에 대한 전망 (Prospects about Nuclear Electro Magnetic Pulse developed by North Korea)

  • 이대성
    • 융합보안논문지
    • /
    • 제17권2호
    • /
    • pp.159-164
    • /
    • 2017
  • 국제사회는 북한의 핵 미사일 도발을 실질적인 위협으로 인식하고 있다. 이러한 배경에는 북한의 핵 미사일에 의한 직접적인 공격도 우려되지만, 북한이 핵전자기파(NEMP)탄을 개발했다는 전자기파(EMP)관련 전문가들과 국내외 정보기관들의 분석과 평가가 있기 때문이다. 전자기파 전문가들은 다음과 같은 측면에서 북한의 핵전자기파탄을 우려하고 있다. 우선, 현대사회의 산업 군사 의료 생활시설 등은 전기 전자시스템으로 구축되어 있어, 북한의 핵전자기파탄이 고도에서 폭발한다면 모든 전기 전자기기는 무력화된다. 다음으로, 공격자의 입장에서 핵전자기파탄은 상대국의 전기 전자기기 시설만을 파괴하고, 인명을 살상하지 않기 때문에 국제사회의 비난가능성이 낮다는 판단을 할 수 있다. 마지막으로, 핵전자기파탄은 목표물을 정확하게 타격할 필요가 없고, 저급한 핵무기의 수준으로 광범위한 지역을 타격할 수 있기 때문에 대량살상무기(WMD)보다 더 위협적이라 할 수 있다. 이러한 측면에서 북한의 핵 미사일 개발에 대한 분석과 평가를 통하여, 북한의 핵전자기파탄 개발에 대한 전망을 하고자 한다.

국가 R&D과제의 기술-산업 연계구조분석 (An Analysis of the Linked Structure for Technology-Industry in National R&D Projects)

  • 이미정;이준영;김도현;심위;정대현;김강회;권오진;문영호
    • 기술혁신학회지
    • /
    • 제15권2호
    • /
    • pp.443-460
    • /
    • 2012
  • 기술은 산업발전과 밀접한 관련이 있고, 이러한 기술과 산업과의 지식흐름에 대한 연계구조를 파악하기 위한 다양한 연구가 진행되었다. 그러나 우리나라 국가연구개발 사업의 기술 및 성과가 어떤 산업으로 흘러가는지에 대한 연구는 진행되지 않았다. 따라서 본 연구에서는 국가연구개발 사업의 $NTIS^{****}$ 정보를 활용하여 실제 국가 R&D에서 수행된 성과물인 특허 데이터를 활용하여 기술-산업에 대한 연계구조를 살펴보고자 한다. 이를 통해 기술과 산업사이의 지식흐름이 어떻게 흘러가고 있는지 분석한다. 연구자가 연구과제의 시작시점에서 예상하는 산업 적용분야와 연구가 종료된 후에 그 연구성과가 실제로 적용되는 기술-산업 적용분야를 밝히고자 하였다. 분석 결과, 다수의 과제는 R&D 시작 전에 예측한 산업분야로 지식흐름이 일어난 것으로 나타났다. 그러나 3개의 산업분야 Y09(의료, 정밀, 광학기기 및 시계), Y10(전기 및 기계장비), Y11(자동차 및 운송장비) 등은 연구자가 예상하지 못한 산업분야에 기술이 적용되는 것으로 분석되었다. 본 연구를 통해서 국가 R&D사업의 기술-산업의 지식흐름 관계를 살펴봄으로써 향후 기술-산업의 효율적인 성과 확산과 투자전략을 세우는 데 기여할 수 있을 것으로 보인다.

  • PDF

제조 공정의 개선을 통한 백색 LED 칩의 성능 개선 (The Improvement for Performance of White LED chip using Improved Fabrication Process)

  • 류장렬
    • 한국산학기술학회논문지
    • /
    • 제13권1호
    • /
    • pp.329-332
    • /
    • 2012
  • LED는 저 전력, 긴 수명, 고 휘도, 빠른 응답, 친환경적인 특성의 여러 장점을 갖고 있기 때문에 청색과 녹색 LED는 교통신호, 옥외 디스플레이, 백색 LED는 LCD 후면광 등의 응용 제품에 사용되고 있다. 여기서 LED의 성능을 향상하기 위하여 출력전력과 소자의 신뢰성을 높이고, 동작전압을 낮추어야 LED 칩의 고효율화가 이루어져야 하는데, 이는 에피택셜층, 표면요철, 패턴이 있는 사파이어 기판, 칩 설계의 최적화, 특수 공정의 개선 등의 기술이 우수해야 한다. 본 연구에서는 측면 에칭 기술과 절연층 삽입기술을 이용하여 사파이어 에피 웨이퍼 위에 GaN-기반 백색 LED 칩을 제작하여 그 성능을 조사하였다. LED 칩의 성능을 개선하기 위한 최적화 설계와 CBL(current blocking layer) 삽입 기술의 개선된 공정을 통하여 LED 칩 성능의 향상을 확인할 수 있었으며, 출력 전력은 광 출력 7cd, 순방향 인가전압 3.2V의 값을 얻었다. 현재의 LCD 후면광원으로 사용되고 있는 LED 칩의 출력에 비하여 성능이 개선되었으며, 의료기기 및 LCD LED TV의 후면광원으로 사용할 수 있을 것으로 기대된다.

컴팩트 플래쉬 방식의 휴대형 산소포화도 측정 및 ECG 감시 시스템의 구현 (Implementation of a ECG monitoring system and portable pulse oximeter for $SpO_2$ using Compact Flash Interface)

  • 김동학;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we aims to develop a microcontroll er-based ECG monitoring system and portable pulse oximeter using Compact Flash Interface. First, portable pulse oximeter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of $SpO_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patient's condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO2 modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact falsh interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

저개발국 모자보건 수준 향상을 위한 국제보건사업 전략 : 에티오피아 티그라이주 사례를 중심으로 (Global Health Project for Maternal Child Health in a Developing Country: Case Study in Tigray, Ethiopia)

  • 방경숙;이인숙;박영숙;채선미;강현주;유주연;박지선;오상준
    • Perspectives in Nursing Science
    • /
    • 제11권1호
    • /
    • pp.1-9
    • /
    • 2014
  • Purpose: The purpose of this study was to demonstrate a two-year global health project to improve maternal and child health (MCH) in Ethiopia. Methods: This is a descriptive case study. The target area is Kilte Awlaelo Woreda in Tigray Regional State, Ethiopia. A baseline survey was conducted to identify the needs of community residents and health care professionals. A MCH program was developed according to a project design matrix that included: infrastructure renovation of health centers; continuing education for midwives, nurses, and health extension workers (HEWs); and improvement of residents' MCH awareness. Project evaluation will examine the structure, process, and outcomes of the program. Results: The baseline survey showed low rates of family planning (31%) and antenatal and postnatal care use (36.1% and 69%, respectively). The institutional birth rate was 13.5%. Midwives and nurses received 2~4 educational programs about family planning and perinatal care. HEWs were also given practical education. Water and electrical infrastructure of all five health centers in the Kilte Awlaelo Woreda were renovated. Additionally, medical supplies and equipment were provided. Community health education on perinatal care, family planning, and personal hygiene was presented. Conclusion: This study highlights the role of nursing in global health and provides basic information on the development and outcomes of the global health project.

  • PDF

직접방식 엑스선 검출기를 위한 $BiI_3$ 특성 연구 (A Study on Bismuth tri-iodide for X-ray direct and digital imagers)

  • 이상훈;김윤석;김영빈;정숙희;박지군;정원범;장무영;문치웅;남상희
    • 한국방사선학회논문지
    • /
    • 제3권2호
    • /
    • pp.27-31
    • /
    • 2009
  • 현재 의료용 엑스선 장비는 기존의 아날로그 방식의 필름, 카세트를 대신하여 디지털 방식인 CR, DR 이 널리 사용되면 그에 관한 연구개발이 활발히 진행되고 있다. 본 연구 에서는 디지털 엑스선 장비의 변환물질로 $BiI_3$(Bismuth tri-iodide)를 적용하여 실험하였으며 기존 선행연구에 비해 만족할만한 결과 값은 얻을 수 없었지만 가장 많이 사용되고 있는 a-Se(Amorphous Selenium)의 단점인 고전압인가와 제작방식의 어려움을 보완할 수 있는 새로운 가능성을 제시해 주었다. 본 연구에서 사용되어진 변환 물질은 순도 99.99%의 $BiI_3$가 이용되었으며 $3cm{\times}3cm$의 크기와 200um의 두께를 가지는 변환물질 층이 제작되었다. 변환 물질의 상하부에는 Magnetron Sputtering system장비를 이용한 ITO 전극이 형성되었다. 형성된 $BiI_3$ 엑스선 변환 물질의 특성 평가를 위해 구조적 분석과 전기적 분석이 이루어 졌다. SEM 측정을 통해 제작된 필름의 표면 및 단면적, 구성 성분을 관찰하였고, 전기적 분석을 위해서는 누설전류, 엑스선에 대한 신호량 및 잡음 대 신호비의 관찰이 이루어졌다. 실험 결과 $BiI_3$$1.6nA/cm^2$의 누설전류와 $0.629nC/cm^2$의 신호량을 측정할 수 있었으며, 이렇게 Screen print method로 제작된 엑스선 검출 물질은 PVD방법을 이용해 제작된 물질과 비슷하거나 더 나은 전기적 특성을 가지고 있었고 이는 제작 방법의 간소화 및 수율을 향상 시킬 수 있어 BiI3도 a-Se를 대체하기 위한 변환물질로 적합하다고 사료된다.

  • PDF

3D 프린팅 응용을 위한 환원그래핀/폴리피롤 복합체 기반의 전도성 폴리카프로락톤 레진의 개발 (Development of Conductive Polycaprolactone (PCL)-resin based on Reduced Graphene Oxide(rGO)/Polypyrrole (Ppy) composite for 3D-printing application)

  • 정현택;정화용;조영광;김창현;김용렬
    • 한국응용과학기술학회지
    • /
    • 제35권3호
    • /
    • pp.935-939
    • /
    • 2018
  • 3D프린팅 기술은 산업적 응용을 넘어서 기계 설비 및 각종 장비의 부품생산뿐만 아니라 의료, 식품, 패션에 이르기까지 많은 시제품들의 개발 및 연구가 진행되고 있다. 3D 프린팅 기반 기술의 적용사례를 볼 때 정밀도와 제작 속도 측면에서도 다른 산업에 충분이 활용될 수 있는 기술의 개발이 보고되고 있으나, 아직까지는 시제품 위주로 이용되고 있으며, 향후 3D 프린팅 기술은 4차산업혁명과 관련하여 광범위한 분야에서 응용될 수 있는 완성품이나 부품제작에 이용될 것으로 예상된다. 본 연구에서는 탄소나노 재료중 대표적으로 많이 이용되는 환원그래핀 [rGO(reduced graphene oxide)]과 전도성 고분자중 생체 친화적인 특성을 갖는 폴리피롤[Ppy(Polypyrrole)]의 복합체를 생분해성 고분자인 폴리카프로락톤 [PCL(polycaprolactone)]과 혼합하여 3D 프린팅용 전도성 레진을 개발하고자 하였다. 결과로, 폴리피롤과 환원그래핀 각각 5 wt%, 0.75 wt% 에서 최적의 전기적 특성을 나타내었으며, 환원그래핀의 농도에 따른 표면분석에서도 이와 부합하는 결과를 확인 할 수 있었다. 본 연구를 통하여 제조된 전도성 레진은 3D 프린팅 뿐만 아니라, 다른 산업분야의 전자재료에도 적용이 가능할 것으로 사료된다.

PC 기반의 심전도-비관혈식 혈압 환자감시장치의 개발 (The Development of Pc Based EGG-NIBP Patient Monitor)

  • 김남현;김경하;주기춘;라상원;송광석;한민수;김성민;이건기;최태영
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권4호
    • /
    • pp.461-469
    • /
    • 1999
  • 환자감시장치는 중환자실, 수술실, 응급실 및 병실에서 환자의 상태인 심전도 파형, 맥박수 , 혈압등을 측정하고 감시하는 기본적인 의료장비이다. 본 논문에서 설계한 환자감시장치는 심전도-비관혈식 혈압 감지장치이다. 심전도는 심장 근육의 이완과 수축에 따라 발생하는 전기 현상으로 대부분의 의사들은 환자의 심장 상태를 심전도 신호 패턴으로 진단을 하고 있다. 심전도 감시장치는 장시간동안 환자의 심장상태를 감시하는데 사용된다. 환자의 혈압을 재는 일은 일반화된 임상 측정의 하나로, 진찰실에서나 또는 특별한 수술중에도 시행되고 있다. 본 논문에서는 동맥 내의 혈압을 비관혈적으로 측정하는 오실로메트릭 방식의 간접 측정 방법을 사용하였다. 개발한 환자감시장치를 수술실 장비와 비교, 검토하였다. 매회 심박수의 최대 차이는 1bpm이며,수축기 혈압 최대 차이는 15mmHg, 이완기 혈압 최대차이는 16mmHg, 평균 혈압 최대 차이는 25mmHg를 보였다. 그러나 결과적으로 나타나는 심박수의 평균 오차는 0.15bpm이며, 수축기 혈압의 평균 오차는 5mmHg, 이완기 혈압의 평균 오차는 10mmHg, 그리고 평균 혈압의 평균 오차는 9mmHg로 나타났다. 본 논문의 심전도-비관혈식 혈압 환자감시장치는 심전도 파형, 맥박수, 그리고 혈압을 측정하고 감시하는 의료 장비로서, 설계된 환자감시장치에 산소포화도.호흡.관혈식 혈압감시장치(IPB) 등의 다기능을 모듈로 구성하여 부착 및 제거가 용이하도록 확장 할 수 있다.

  • PDF

냉각 풍선 절제술과 3D 고주파 절제술을 이용한 심방세동 치료 시 절제술 시행 시간과 방사선 피폭 영향과의 연관성 (Relation between Ablation Execution Time and Radiation Exposure Effect in the Treatment of Atrial-fibrillation using Cryo-balloon and 3D Radio-frequency Ablation)

  • 서영현
    • 한국방사선학회논문지
    • /
    • 제16권4호
    • /
    • pp.427-434
    • /
    • 2022
  • 심방세동 치료는 3D장비를 이용한 고주파 절제술과 냉각 풍선을 이용한 냉각 풍선 절제술이 있다. 두 시술 모두 혈관 조영 장비를 이용해 심장의 구조를 파악한 뒤 진입하는 공통점이 있다. 따라서 시술 시간에 따른 피폭의 영향이 환자와 시술자 모두 위협이 될 수 있다는 단점이 존재하므로 본 연구를 통해 총 절제술 시간과 방사선 피폭 영향 등의 연관성을 확인하고자 한다. 2019년 03월부터 2022년 07월까지 관상 동맥 조영술과 부정맥 시술을 동시에 시행한 41명 환자의 후행적 데이터를 이용하였다. 총 절제술 시간에 대한 범위는 절제술 시작 시점부터 종료 시점까지의 기록된 데이터를 대상으로 하였다. 3D 고주파 절제술 종료 시점은 4곳의 폐정맥에 대해 절제술 시행을 완료한 시점으로 하였고 냉각 풍선 절제술의 경우 전기적 절연에 성공한 데이터를 대상으로 하였다. 총 절제술에 걸린 시간을 분석한 결과 냉각 풍선 절제술에 걸린 시간이 1037.29±103.66 s로 3D를 이용한 고주파 절제술 3485.9±405.71 s 보다 2448.61 s 더 빠른 시술 시간을 보였고 통계적으로 유의했다. (p<0.05) 총 투시 조영 시간을 분석한 결과 3D를 이용한 고주파 절제술 피폭 시간이 2573.75±239.08 s로 냉각 풍선 절제술 피폭 시간 4290.9±420.42 s 보다 1717.15 s만큼 덜 노출됐으며 통계적으로 유의했다. 총면적 선량의 경우 3D 고주파 절제술이 59.04±13.1 uGy/m2로 냉각 풍선 절제술 980.6±658.07 uGy/m2보다 921.56 uGy/m2만큼 저 선량을 나타냈으며 통계적으로 유의했다. 냉각 풍선 절제술의 절연 시간이 3D 고주파 절제술보다 짧은 것으로 보아 환자의 상태가 좋지 않아 빠른 시술이 필요한 경우 냉각 풍선 절제술을 이용하는 방법이 효과적일 것으로 판단된다. 그러나 심방세동이 오래된 환자일 경우 심장의 구조적 변화가 발생할 확률이 높으므로 조작이 어려운 냉각 풍선 절제술 보다 3D 고주파 절제술을 이용해 치료하는 방법이 좋을 것으로 사료된다.