• 제목/요약/키워드: mechanical transducer

검색결과 387건 처리시간 0.027초

A new ultrasonic power generator using instantaneous current resultant control-based inverter and its control system

  • Kim, Dong-Hee;Kim, Young-Seok;Yoo, Dong-Wook;Kim, Yo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.631-636
    • /
    • 1987
  • The design of ultrasonic transducer energy processing systems requires highly reliable command featuring mechanical frequency tracking and constant velocity control of the ultrasonic transducer with an acoustic load. This paper presents a new conceptional instantaneous current resultant control base high-frequency inverter using self turn-off devices driving an electrostrictive ultrasonic transducer system and its optimum control technique, which is implemented by feed-back of the ultrasonic transducer applied voltage and instantaneous velocity of the transducer vibrating system through a Phase-Locked-Loop control scheme. The feedback voltage corresponding to instantaneous velocity is averaged over a half-period with respect to constant amplitude/constant velocity control strategy. Described are the theory of this signal detection technique and the experimental set-up.

  • PDF

배열 탐촉자를 사용한 유도초음파의 모드선정 기법 (Dynamic Mode Tuning of Ultrasonic Guided Wave Using an Array Transducer)

  • 김영환;송성진;박준수;김재희;엄흥섭
    • 비파괴검사학회지
    • /
    • 제25권1호
    • /
    • pp.20-26
    • /
    • 2005
  • 유도초음파는 판, 봉 또는 관과 같은 구조물의 장거리 탐상에 사용되고 있다. 그러나, 유도초음파에는 그 모드가 많고 전파속도가 달라서, 원하는 모드를 선택적으로 발생시키고 수신하는 기법이 유도초음파를 응용하는데 핵심적인 기술 중 하나이다. 본 연구에서는 배열형 탐촉자의 위상을 조절하여 유도초음파를 발생시키는 방법에 대하여 연구하였다. 이를 위하여 8채널 초음파 펄서/리시버, 그리고 각각의 채널을 일정한 시간간격으로 구동할 수 있는 회로를 개발하였다. 8개의 탐촉자를 만들어서 배열형으로 사용하여 유도 초음파를 발생시켰다. 이웃한 요소 탐촉자 사이의 구동시간 간격을 제어하여 이에 맞는 위상속도를 지닌 유도초음파를 선택적으로 발생시켰고, 발생된 유도초음파의 군속도를 측정하였으며, 배열탐촉자에서 수신된 신호를 시간지연을 가지고 합성하여 유도초음파의 모드를 선택적으로 수신하였다. 그 결과, 이웃한 요소 탐촉자 사이의 구동시간 간격을 바꿈으로서 원하는 모드의 유도초음파를 선택적으로 발생시킬 수 있었다.

Measurements of Minute Unsteady Pressure on Three-Dimensional Fan with Arbitrary Axis Direction

  • Hirata, Katsuya;Fuchi, Takuya;Onishi, Yusuke;Takushima, Akira;Sato, Seiji;Funaki, Jiro
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권1호
    • /
    • pp.1-10
    • /
    • 2010
  • The present study is a fundamental approach to develop the measuring technology for minute fluctuating pressures on the three-dimensional blade surfaces of the fan which rotates with an arbitrary rotation-axis direction. In this situation, we are required to correct the centrifugal-force effect, the gravitational-force effect and the other leading-error effects for accurate measurements of the minute pressures. The working fluid is air. A pressure transducer rotating with an arbitrary attitude is closely sealed by a twofold shroud system. The rotational motion with an arbitrary attitude is produced by fixing the pressure transducer to the cantilever which is connected to a motor-driven disc of 500mm in diameter and 5mm in thickness. As a result, we have quantitatively determined main governing effects upon the non-effective component of the pressure-transducer signal.

습식방식의 초음파 유량계 시스템 개발에 관한 연구 (A Study on the Wet Type Ultrasonic Flow-meter System Development)

  • 이응석;권오훈;노명환;이형석
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1638-1644
    • /
    • 2005
  • This paper suggests fur the study on a fluid velocity measuring system using ultrasonic transducer. In general, the time difference method to measure the distance between transducers has been known. In this paper, the practical technology for manufacturing ultrasonic flow meter system is studied using the time difference method. The ultrasonic transducer was designed and manufactured. The transmission and receiving algorithm for ultrasonic signal was studied. The ultrasonic flow measuring system was experimented in laboratory using a water reservoir for verifying the distance measuring accuracy. Finally, it was tested in flow calibration laboratory for the velocity measuring performance. The system, designed in this study, showed 0.3 mm resolution in distance measurement. For precise flow measurement, a high speed triggering algorithm is required for ultrasonic signal receiving.

초음파 사각 트랜스듀서의 최적설계를 위한 지향성 해석 (Directivity Analysis for Optimal Design of Ultrasonic Angle Beam Transducer)

  • 남영현
    • 대한기계학회논문집A
    • /
    • 제32권9호
    • /
    • pp.796-803
    • /
    • 2008
  • Ultrasonic testing uses the directivity of the ultrasonic wave, which propagates in on direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of an ultrasonic wave is related to the choice of probe arrangement, testing sensitivity and scanning pitch and correct measurement of defect size and location. This paper describes on the directivity measurement of ultrasonic wave using the visualization method. The directivity of shear wave emitted from the angle beam transducer were constant during propagation. The difference of directivity was existed between 2 MHz and 4 MHz angle beam transducers. When these experimental results were compared with the theory which was based on the continuous wave, it showed good agreement with theoretical directivity on the principal lobe.

마이크로 스테이지의 유한요소해석 (A Study on the Optimal Structural Design using FEM for Micro Stage)

  • 김재열;곽이구;한재호;김항우;하하변명
    • 한국정밀공학회지
    • /
    • 제19권10호
    • /
    • pp.60-65
    • /
    • 2002
  • For optimal design of micro stage, we measured the displacement of piezoelectric transducer that was based on voltage value. And the micro stage was analyzed using FEM with displacement data including voltage value of piezoelectric transducer. For verification of analysis results, the displacements were measured by using Laser-interferometer. And researchers confirmed to propriety on design of micro stage with FEM, we obtained 3.5% error rate between measurement results and analyzing results.

음향 매질의 추가질량 효과를 고려한 광음향 영상용 초소형 압전 기반 초음파 트랜스듀서의 개발 (Development of a Piezoelectric Micro-machined Ultrasonic Transducer for Photoacoustic Imaging that Accounts for the Added Mass Effect of the Acoustic Medium)

  • 안홍민;문원규
    • 센서학회지
    • /
    • 제29권1호
    • /
    • pp.33-39
    • /
    • 2020
  • Typically, photoacoustic images are obtained in water or gelatin because the impedance of these mediums is similar to that of the human body. However, these acoustic mediums can have an additional mass effect that changes the resonance frequency of the transducer. The acoustic radiation impedance in air is negligible because it is very small compared to that of the transducer. However, the high acoustic impedance of mediums such as the human body and water is quite large compared to that of air, making it difficult to ignore. Specifically, in a case where the equivalent mass is very small, such as with a micro-machined ultrasound transducer, the additional mass effects of the acoustic medium should be considered for an accurate resonance frequency design. In this study, a piezoelectric micro-machined ultrasonic transducer (pMUT) was designed to have a resonance frequency of 10 MHz in the acoustic medium of water, which has similar impedance as the human body. At that time, the resonance frequency of the pMUT in air was calculated at 15.2 MHz. When measuring the center displacement of the manufactured pMUT using a laser vibrometer, the resonance frequencies were measured as 14.3-15.1 MHz, which is consistent with the finite element method (FEM) simulation results. Finally, photoacoustic images of human hair samples were successfully obtained using the fabricated pMUT.

Experimental Study for Defects Inspection of CFRP Using Laser-Generated Ultrasound

  • Lee, Joon-Hyun;Park, Won-Su;Byun, Joon-Hyung
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.41-45
    • /
    • 2006
  • The fabrication process of fiber placement system of carbon fiber reinforced plastic (CFRP) requires real time process control and reliable inspection to ensure quality by preventing defects such as delamination and void. Therefore, novel non-contact inspection technique is required during the non-destructive evaluation in a fiber placement system. For the inspection of delamination in CFRP, various methods to receive laser-generated ultrasound were applied by using piezoelectric transducer, air-coupled transducer, wavelet transform and scanning laser ultrasonic technique. Laser-generated ultrasound was received with a conventional piezoelectric sensor in contacting manner. Then signal characteristics due to defects were analyzed to find a factor for detecting defects. Air-coupled transducer was used for reception of laser-generated guided wave using linear slit array in order to generate high frequency guided wave. And line scan technique was used to confirm the capability of on-line application. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer. The first peak of the frequency spectrum under 100kHz in the delamination region is higher than in the sound region. By using this feature, the line scanned frequency data were acquired in fully non-contact generation and reception of ultrasound. This method was proved as useful technique for detecting delamination in CFRP.

  • PDF

Analysis on an improved resistance tuning type multi-frequency piezoelectric spherical transducer

  • Qin, Lei;Wang, Jianjun;Liu, Donghuan;Tang, Lihua;Song, Gangbing
    • Smart Structures and Systems
    • /
    • 제24권4호
    • /
    • pp.435-446
    • /
    • 2019
  • The existing piezoelectric spherical transducers with fixed prescribed dynamic characteristics limit their application in scenarios with multi-frequency or frequency variation requirement. To address this issue, this work proposes an improved design of piezoelectric spherical transducers using the resistance tuning method. Two piezoceramic shells are the functional elements with one for actuation and the other for tuning through the variation of load resistance. The theoretical model of the proposed design is given based on our previous work. The effects of the resistance, the middle surface radius and the thickness of the epoxy adhesive layer on the dynamic characteristics of the transducer are explored by numerical analysis. The numerical results show that the multi-frequency characteristics of the transducer can be obtained by tuning the resistance, and its electromechanical coupling coefficient can be optimized by a matching resistance. The proposed design and derived theoretical solution are validated by comparing with the literature given special examples as well as an experimental study. The present study demonstrates the feasibility of using the proposed design to realize the multi-frequency characteristics, which is helpful to improve the performance of piezoelectric spherical transducers used in underwater acoustic detection, hydrophones, and the spherical smart aggregate (SSA) used in civil structural health monitoring, enhancing their operation at the multiple working frequencies to meet different application requirements.

의료용 초음파 위상배열 트랜스듀서의 열 분산 방안 (Thermal Dispersion Method for a Medical Ultrasonic Phased Array Transducer)

  • 이원석;노용래
    • 한국음향학회지
    • /
    • 제34권3호
    • /
    • pp.210-218
    • /
    • 2015
  • 초음파 영상 품질의 향상을 위해 트랜스듀서의 구동전압을 높이게 되면 트랜스듀서에서 열이 발생하여 환자의 피부 화상 및 트랜스듀서의 성능 저하를 초래할 수 있다. 따라서, 이렇게 온도가 상승하지 않도록 트랜스듀서 내의 열을 효율적으로 분산할 수 있는 방안에 대해 연구하였다. 이때 열 분산 해석 대상으로 중심주파수가 3 MHz이고 32채널을 가진 위상배열 트랜스듀서를 선정하였다. 먼저 트랜스듀서의 동작에 따른 발열 구조를 이론적으로 분석하였고, 그 결과로서 재료의 감쇠와 음압의 크기가 발열에 영향을 미치는 것을 확인하였다. 나아가 유한요소 해석을 통해 트랜스듀서 구성소자의 물성이 열 분산에 미치는 영향을 분석하였다. 분석된 결과를 바탕으로 트랜스듀서 내 열이 잘 분산되기 위한 구성소자의 열물성을 정하였다. 도출된 열 물성을 유한요소 해석 모델에 적용한 결과 환자와 접촉되는 부분인 음향렌즈의 최고온도가 원래 값의 51 %로 저하되었다.