• 제목/요약/키워드: mechanical degradation

검색결과 1,258건 처리시간 0.029초

Role of FT-IR in Assessing Lubricant Degradation - A Study on Palm Oil Methyl Ester Blended Lubricant

  • Maleque, M.A.;Masjuki, H.H.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.351-352
    • /
    • 2002
  • In this paper, studies were made on the palm oil methyl ester (POME) added lubricants using FT-IR for monitoring oil degradation. In order to assess the degradation characteristics of POME added lubricant by FT-IR, static oxidation test was conducted using three different blended lubricants (viz, zero percent POME, five percent POME and ten percent POME with mineral-based oil) for 280 hrs. The oxidation temperature was set at $140^{\circ}C$. FT-IR quantitative data indicate an increased in oxidation products which was formed from 10% POME added lubricants after 280 hrs of oxidation test. The 5% POME added lubricant and mineral-based lubricant (without POME) showed less oxidation product after the test. From the FT-IR spectrum analysis of the oxidized oils it could be concluded that 5% POME can improve the performance of mineral-based oil by forming protective films.

  • PDF

원자력발전소 수명평가 및 수명관리 기술개발 (Development of Lifetime Evaluation and Management Technologies for Nuclear Power Plants)

  • 진태은
    • 대한기계학회논문집A
    • /
    • 제33권10호
    • /
    • pp.991-1004
    • /
    • 2009
  • Operating experience of the various components in the nuclear power plants has shown that a variety of degradation mechanisms can occur during operation. Therefore, the accurate lifetime evaluation and systematic management are very important for the safe as well as the economical operation of the nuclear power plants. In this paper, the characteristics of a total of 17 degradation mechanisms were reviewed and the plausible degradation mechanisms such as stress corrosion cracking, fatigue, irradiation embrittlement, and so on, were identified. Also, the lifetime evaluation technologies which have been developed for the application to the domestic nuclear power plants are described. In addition, a total of 48 aging management programs which have been established for the safe operation of the various components are explained.

자동차용 head lamp의 수밀원인 분석 (Failure analysis on the phenomenon of water condensing of automotive head lamp assembly)

  • 조영진;전종수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1349-1354
    • /
    • 2008
  • In this study, we try to find the root cause of water condensing failures in a headlamp using chemical and mechanical analysis. Through the surface inspection by OM, SEM and CT, it was found that water infiltrate into the headlamp through hotmelt adhesive debonding part caused by adhesion force degradation and poor quality. IR spectra shows that adhesion force degradation are characterized by increase of some functional group(1742, 1710, 1649, 1016). Through the ESPI measurement, it is turned out that bonding structural change by thermal expansion and degradation of adhesive can be the cause of void generation. So it is recommended that cooling passage and the bonding part should be redesigned to give a guarantee of less thermal stress and high adhesion quality.

  • PDF

고온초전도마그네트 내부의 스트레인에 의한 임계전류밀도 감소 계산 (Calculation of Critical Current Density Degradation in the HTS Magnet due to Mechanical Strain)

  • 이인규;나완수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.260-263
    • /
    • 1997
  • In this paper, we describe the mechanical strain effects on the critical current density of HTS (BSCCO) pancake-type-magnet. Firstly the strain of pancake coil is calculated in terms of coil length, which is also a function of angle, and then the critical current density degradation due to strain is calculated along the coil. We assumed that the critical current density degradation pattern is same with that of $Nb_{3}Sn$. We also modelled the effects of magnetic field on the critical curent degradation, and the results are compared with those with null magnetic field.

  • PDF

산불 피해목의 재질변화에 관한 연구(II) - 산불 피해 소나무의 경시적 재질변화 - (Variation of Material Properties of Fire-killed Timber - Impact of Time on Degradation of Mechanical Properties -)

  • 박정환;박병수;김광모;이도식
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권1호
    • /
    • pp.30-35
    • /
    • 2008
  • 동해안 지역에서 산불로 고사된 소나무의 5년에 걸친 경시적 재질 변화를 역학성능을 중심으로 조사하였다. 고사에 따른 재질열화로 가장 크게 영향 받는 역학성능은 충격 휨 흡수에너지였다. 따라서 고사 초기의 재질변화를 예측하는 지표로 활용이 가능할 것으로 밝혀졌다. 고사 경과에 따라 변재의 재질열화가 심재에 비해 두드러지게 진행되었다. 열화의 정도는 충격 휨 흡수에너지가 가장 컸으며 압축강도가 가장 작았다. 고사 이후의 외관 변화와 역학성능의 열화진행 정도로 볼 때 산불피해 소나무의 유효한 활용을 위한 적정 벌채 시기는 산불발생 1년 이내가 바람직한 것으로 밝혀졌다.

핵 융합로 구조재료의 예민화 열처리에 따른 극저온 파괴거동 및 분극특성 (Cryogenic fracture behaviors and polarization characteristics according to sensitizing heat treatment on structural material of the nuclear fusion reactor)

  • 권일현;정세희
    • 대한기계학회논문집A
    • /
    • 제22권2호
    • /
    • pp.311-320
    • /
    • 1998
  • The cryogenic fracture behaviors of austenitic stainless steel HN2 developed for nuclear fusion reactor were evaluated quantitatively by using the small punch(SP) test. The electrochemical polarization test was applied to study thermal aging degradation of HN2 steel. The X-ray diffraction(XRD) analysis was conducted to detect carbides and nitrides precipitated on the grain boundary of the heat treated HN2 steel. The mechanical properties of the HN2 steel significantly decreased with increasing time and temperature of heat treatment or with decreasing testing temperature. The integrated charge(Q) obtained from electrochemical polarization test showed a good correlation with the SP energy(ESP) obtained by means of SP tests. From the results observed in the x-ray diffraction and anodic polarization curve, it was known that the material the grain boundary. Combining SP test and electrochemical polarization test, it could be useful tools to non-destructively evaluate the cryogenic fracture behaviors and the aging degradation for cryogenic structural material.

Concrete structures under combined mechanical and environmental actions: Modelling of durability and reliability

  • Vorechovska, Dita;Somodikova, Martina;Podrouzek, Jan;Lehky, David;Teply, Bretislav
    • Computers and Concrete
    • /
    • 제20권1호
    • /
    • pp.99-110
    • /
    • 2017
  • Service life assessments which do not include the synergy between mechanical and environmental loading are neglecting a factor that can have a significant impact on structural safety and durability assessment. The degradation of concrete structure is a result of the combined effect of environmental and mechanical factors. In order to make service life design realistic it is necessary to consider both of these factors acting simultaneously. This paper deals with the advanced modelling of concrete carbonation and chloride ingress into concrete using stochastic 1D and 2D models. Widely accepted models incorporated into the new fib Model Code 2010 are extended to include factors that reflect the coupled effects of mechanical and environmental loads on the durability and reliability of reinforced concrete structures. An example of cooling tower degradation by carbonation and an example of a bended reinforced concrete beam kept for several years in salt fog are numerically studied to show the capability of the stochastic approach. The modelled degradation measures are compared with experimental results, leading to good agreement.

열충격 시험을 통한 MLCCs SAC305 무연 솔더 접합부의 IMCs 성장과 접합특성 저하에 관한 연구 (A Study on The Degradation Characteristics of MLCCs SAC305 Lead-Free Solder Joints and Growth IMCs by Thermal Shock Test)

  • 정상원;강민수;전유재;김도석;신영의
    • 한국전기전자재료학회논문지
    • /
    • 제29권3호
    • /
    • pp.152-158
    • /
    • 2016
  • The bonding characteristics of MLCCs (multi layer ceramic capacitor, C1608) lead-free solder (SAC305) joints were evaluated through thermal shock test ($-40^{\circ}C{\sim}125^{\circ}C$, total 1,800 cycle). After the test, IMCs( intermetallic compounds) growth and cracks were verified, also shear strengths were measured for degradation of solder joints. In addition, The thermal stress distributions at solder joints were analyzed to compare the solder joints changes before and after according to thermal shock test by FEA (finite elements analysis). We considered the effects of IMCs growth at solder joints. As results, the bonding characteristics degradation was occurred according to initial crack, crack propagations and thermal stress concentration at solder-IMCs interface, when the IMCs grown to solder inside.

전기화학적 재활성화 분극시험에 의한 터빈부재의 열화손상 평가 (Degradation Damage Evaluation for Turbine Structural Components by Electrochemical Reactivation Polarization Test)

  • 권일현;백승세;류대영;유효선
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1241-1249
    • /
    • 2002
  • The extent of materials deterioration can be evaluated accurately by mechanical test such as impact test or creep test. But it is almost impossible to extract a large test specimen from in-service components. Thus material degradation evaluation by non-destructive method is earnestly required. In this paper, the material degradation for virgin and several aged materials of a Cr-Mo-V steel, which is an candidated as structural material of the turbine casing components for electric power plant, is nondestructively evaluated by reactivation polarization testing method. And, the results obtained from the test are compared with those in small punch(SP) tests recommended as a semi-nondestructive testing method using miniaturized specimen. In contrast to the aged materials up to 1,000hrs which exhibit the degradation behaviors with increased ${\Delta}[DBTT]_{SP}$, the improvement of mechanical property can be observed on the 2,000hrs and 3,000hrs aged materials. This is because of the softening of material due to the carbide precipitation, the increase of ferritic structures and the recovery of dislocation microstructure by long-time heat treatment. The reactivation rates($I_R/I_{Crit},\;Q_R/Q_{Crit}$) calculated by reactivation current densityt ($I_R$) and charge($Q_R$) in the polarization curves exhibit a good correlation with ${\Delta}[DBTT]_{SP}$ behaviors.

고온부재의 재질열화에 따른 응력부식균열 평가에 관한 연구 (A Study on Stress Corrosion Cracking Evaluation with Material Degradation of High Temperature Components)

  • 박종진;유호선;정세희
    • 대한기계학회논문집A
    • /
    • 제20권4호
    • /
    • pp.1123-1132
    • /
    • 1996
  • It has been reported that high temperature structural components represent the phenomenon of material degradation according to a long term service under high temperature and pressure. Especially, fossile power plant components using the fossil fuel and heavy oil are affected by dewpoint corrosion of $H_2SO_4$produced during a combustion. Therefore, the service materials subjected to high temperature and pressure may occur the stress corrosion cracking. The object of this paper is to investigate SCC susceptibility according to the material degradation of the high temperature structural materials in dewpoint corrosive environment-$H_2SO_4$.The obtained results are summarized as follows : 1) In case of secondary superheater tube, the fractograph of dimple is observed at the concentration of $H_2SO_4$-5%. When the concentration of $H_2SO_4$ is above 10%, the fracture mode is shifted from a transgranular fracture to an quasi-intergranular fracture according to the increment of concentration. 2) In the relationship between [$\Delta$DBTT]$_sp$ and SCC susceptibility, it is confirmed that the greater material degradation degree is, the higher SCC susceptibility is. In addition, it can be known that SP test is useful test method to evaluate SCC susceptibility for high temperature structural components. 3) When [$\Delta$DBTT]$_sp$ is above 17$17^{\circ}C$ the SCC fracture behavior is definitely observed with SCC susceptibility of above 0.4.