• Title/Summary/Keyword: measuring weight

Search Result 1,158, Processing Time 0.034 seconds

An Analysis of Test Results Using the New Fusion Weight Conversion Algorithm for High-speed Weigh-In-Motion System (주행시험을 통한 고속축중기의 융합형 중량환산 알고리즘 효과 분석)

  • Kim, Jong Woo;Jung, Young Woo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.4
    • /
    • pp.67-80
    • /
    • 2020
  • High-speed weigh in motion (HS-WIM) is a real-time unmanned system for measuring the weight of a freight-carrying vehicle while it is in motion without controlling vehicle traffic flow or deceleration. In Korea, HS-WIM systems are installed on the national highways and general national ways for pre-selection by law enforcement. In this study, to improve the measurement accuracy of HS-WIM, we devise improvements to the existing integral and peak weight conversion algorithms, and we provide a new fusion algorithm that can be applied to the mat-type HS-WIM. As a result of analyzing vehicle driving tests at a real site, we confirmed the highest level of weight-measuring accuracy.

Effects of Hot Water Treatment and Dialysis on Measuring the Average Molecular Weight of Alginates (열수처리와 투석이 alginates의 평균분자량의 측정에 미치는 영향)

  • YOU Byeong Jin;LIM Yeong Seon;RYU Hong Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • In preparing sodium alginates from sea tangle (Laminaria japonica) powder using the Mexican process, alkaline extraction, conversion to alginic acid and reversion to sodium alginates were used to increase purity. The effect of hot water treatment and dialysis on measuring the average molecular weight of sodium alginates were investigated. Intrinsic viscosity and average molecular weight of sodium alginates after dialysis were higher than those before dialysis. Average molecular weight of sodium alginates treated with hot water was higher than that without. Hot treatment has little effect on the ash content of sodium alginates. Ash content of sodium alginates before dialysis were $27-30\%$ those after dialysis were $10\%.$ After dialysis, Na content was highest $(89-91\%),$ K was $11-12\%,$ Ca was $1.9\%,$ and Mg was $0.05\%.$ Ash content of alginates had little effect on average molecular weight. SAV (slope of apparent viscosity) of alginates solution after dialysis showed higher values than before. SAV of the alginates with hot water treatment were higher than without treatment.

Reverse Engineering for Sculptured Surfaces by Using NURBS Approximation (역공학(Reverse Engineering)을 위한 자유곡면 형상의 NURBS Approximation)

  • Cho, Jae-Hyung;Cho, Myung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.8
    • /
    • pp.108-115
    • /
    • 2002
  • In measuring step for reverse engineering of sculptured surfaces, computer vision system is used to simplify the complicated surface by boundary edge detection method that minimizes the measuring error. The measured data by Coordinate measuring machine is clouded data points of surfaces which is segmented surface using image process. In this research, the measured data is approximated as NURBS surfaces by new suggested algorithm. The position and number of control points, selection of parametric values and compensation of weight factors are proposed. Finally, surface model is simulated and improved resulting performance is obtained.

THE DEVELOPMENT OF THE WATER LOADED PRESSURE METHOD FOR MEASURING EGGSHELL QUALITY

  • Kang, C.W.;Nam, K.T.;Olson, O.E.;Carlson, C.W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.9 no.6
    • /
    • pp.723-726
    • /
    • 1996
  • A water loaded pressure device using water as the breaking force was developed to evaluate eggshell strength and compared with a dropping ball techniques. Further, relationships of shell thickness and weight of eggs to shell strength were also studied. Values for both of the shell strength measuring methods showed a highly significant correlation (p < 0.001) with shell thickness. The water loaded pressure method had a much higher simple correlation coefficient for shell thickness (r = + 0.786) than the dropping ball method (r = + 0.577). The shell strength measured by the water loaded pressure method appeared not to be correlated to egg weight. On the other hand, the negative sign of the standard partial regression coefficient and the partial regression coefficient of egg weight in the estimated multiple regression equation implied that for a given shell thickness a larger egg tended to have less shell strength than a smaller egg.

Measurement uncertainty in heavy-weight floor impact sounds (측정 불확도에 따른 중량충격음 측정편차에 관한 연구)

  • Yoo, Seung-Yup;Kim, Yong-Hee;Sim, Myoung-Hee;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.826-829
    • /
    • 2008
  • In a field measurement, measurement errors are produced by measuring environments and systematic errors in the measurement procedure. Measurement errors can be expressed as a measurement uncertainty. In this study, the measurement uncertainty and various measuring factors are investigated in heavy-weight impact sounds. According to KS 2810-2, the model functions, which is the estimation of the maximum SPL measurement in each octave band frequency, are determined. From this estimation model, 3.53dB is shown in 63Hz. This level is caused by the sound field of the receiving room, which does not meet the diffusing field.

  • PDF

The Study on Acute and Subacute Toxicity and Sarcoma-180 Anti-cancer Effects of Vermilionum (영사(靈砂)의 급성(急性).아급성(亞急性) 독성(毒性) 및 Sarcoma-180 항암효과(抗癌效果)에 관(關)한 문헌적(文獻的) 연구(硏究))

  • Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.6 no.3
    • /
    • pp.39-47
    • /
    • 2003
  • Background & Methods : In order to measure the acute and subacute toxicity of Vermilionum and it's anti-cancer effects, Sarcoma-180 abdominal cancer cells were injected intravenously. The following results were obtained after measuring the survival rate, toxicity of the NK cells, and IL- 2 productivity. Results : 1. It was impossible to measure $LD_{50}$ value in the acute toxicity test and no toxic effects were witnessed in the clinical observation. 2. No significant differences were shown in the weight changes between the experiment groups and the control group in the acute toxicity test. 3. No peculiar toxic effects were shown in the subacute toxicity test and the weight changes were insignificant between the experiment groups and the control group. 4. In measuring the survival rate after inducing abdominal cancer by Sarcoma-180, the experiment groups showed increased of 9.52% compared to the control group. 5. In measuring the activity of NK cells, no significant changes were shown between the experiment groups and the control group. 6. In measuring the productivity of IL-2, significant reduction was shown in the experiment groups compared to the normal group, but no significance was witnessed compared to the control group.

An Image Processing System for Measuring the Weight of A Dairy Cattle (젖소 체중측정을 위한 영상처리 시스템)

  • 이대원;김현태
    • Journal of Animal Environmental Science
    • /
    • v.7 no.3
    • /
    • pp.183-190
    • /
    • 2001
  • The objective of this research was to design and construct an image processing system to measure easily and accurately cow's weight. The image processing system was built for a dairy cattle to be measured and estimated it's weight using camera and personal computer. The pixel numbers, which was derived from the image processing system, were counted to estimate the weight of a dairy cattle. They were utilized various was for finding the relationships between pixel numbers and it's real weight. Based on the results of this research the following conclusions were made: 1. It's weight could be estimated by using pixel numbers, which was captured from top and side cameras to measure it. The correlations with tea-view pixel numbers, side-view pixel numbers, superficial area pixel numbers and the volume pixel numbers were 0.909, 0.939, 0.944 and 0.965. 2. 50 cattle was used to execute an experiment with the image processing system, but average errors were big to make out the good relationship between cow's weight and pixel numbers. In order measure accurately a cattle weight, cattle weight, cattle groups would be divided by the age of cattle and further study should be carried out to be based on the results of this research. 3. The average time it took to perform the image processing to be measure it was 10 seconds, but it took 10 minutes for cattle to enter for measuring it's weight into the weighting system.

  • PDF

A method for feeding flow rate control by measuring weight (무게 측정에 의한 원료 정량 투입 제어 방법)

  • 권오정;황일영;이광순
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.937-940
    • /
    • 1992
  • A cost-saving feeding rate contro method for a batch reaction process is proposed by reconfigurating the flow rate control loop where the feeding rate is estimated by differentiating weight measurement. While the existing control methods require either a flow rate measurement device or a flow rate estimator, the proposed method is devised not to require neither of these facilities by directly controlling the tank weight with a time-varying set point. Experimental evaluation in a pilot-scale unit shows that the proposed method can significantly reduce the actuator hunting of the existing method where the flow rate is estimated by differentiating the weight measurement.

  • PDF

The Test-Retest Reliability and Criterion-Related Validity of a Trunk Stability Robot When Measuring Static Sitting and Standing Symmetry in Stroke Patients (뇌졸중 환자들을 위한 체간 안정화 로봇의 정적인 앉기와 서기 대칭성 평가의 검사-재검사간 신뢰도와 기준 관련 타당도)

  • An, Seung-Heon;Kim, Dong-Hoon;Jang, Young-Min
    • PNF and Movement
    • /
    • v.16 no.3
    • /
    • pp.405-414
    • /
    • 2018
  • Purpose: The purpose of this study was to examine test-retest reliability and criterion-related validity of a trunk stability robot when measuring the weight-bearing symmetry static sitting and standing in stroke patients. Methods: For 27 stroke patients, weight-bearing symmetry was assessed twice, 7 days apart. The intraclass correlation coefficient (ICC2,1) and minimal detectable change (MDC) were used to examine the level of agreement between test and retest. The criterion-related validity of weight -bearing symmetry was demonstrated by Spearman correlation of modified Barthel index (MBI), the sit to stand test (STS), the timed up & go Test (TUG), and the function in sitting test (FIST). Results: the test-retest agreements were excellent for the weight-bearing symmetry of static sitting (ICC2,1: 0.90) and standing (ICC2,1: 0.89). It all showed that the acceptable MDC for the weight-bearing symmetry of static sitting and standing was 0.11 and 0.16, respectively (highest possible score<20 %), indicating that the measures had a small and acceptable degree of measurement error. The weight-bearing symmetry of static sitting was significantly correlated with the TUG(r=-0.45) and FIST(r=0.46)(p<0.05); the weight-bearing symmetry of static standing was also significantly correlated with MBI (r=0.65), TUG (r=-0.67), FIST (r=0.61)(p<0.01), and STS (r=-0.47)(p<0.05). Conclusion: The weight-bearing symmetry of static sitting and standing assessed by the trunk stability robot showed highly sufficient test-retest agreement and mild-to-moderate validity. It could also be useful for clinicians and researchers to evaluate balance performance and monitor functional change in stroke patients.

Development of the Experimental Apparatus to Measure a Pore Size of Micro-pore Fabrics Used for a Bedding to Block the House Dust Mite Allergen (집먼지 진드기 알레르겐 차단 침구에 사용되는 극세 공극 직물의 공극 측정을 위한 입자 투과 실험 장치의 개발)

  • Kim, Donhue
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.557-563
    • /
    • 2022
  • In order to measure the allergen penetration of micropore fabrics, it is necessary to develop a convenient and appropriate experimental method for measuring a pore size of micropore fabrics. In this study, a simple and economical experimental apparatus was developed for the analysis of the pore size of micropore fabrics by measuring the weight reduction rate. In addition, the allergen blocking properties was evaluated by measuring the pore sizes of various fabrics. According to this study, the size of the pores of the microporous fabric could be obtained by measuring the weight reduction rates. In addition, higher weight reduction rate was obtained as the suction pressure passing through the particle permeation device decreased and the suction time was increased. It is expected that the developed experimental method and apparatus can be utilized as an experimental standard for quality control methods to verify the effectiveness of micropore fabrics used for house dust mite blocking bedding.