• Title/Summary/Keyword: measuring vessel

Search Result 156, Processing Time 0.03 seconds

THE STUDY ON THE NOISE IN THE VESSEL (선박소음에 관한 연구)

  • PARK Jung-Hee;KIM Sang-Han
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.8 no.4
    • /
    • pp.202-207
    • /
    • 1975
  • During the term of June, 7 to August 11, the noises in the maine engine room in terms of the r. p. m. of the Pung-Yang Ho (4,500 H. P.), the Chuk-Yang Ho (3,800 H. P.), the Dong-Bang Ho (3,000 H. P.), the Oh-Dae San Ho (2,690 H, P.), the Kwan-Ak-San Ho (1,000 H. P.) and the Back-Kyung Ho (850 H. P.) (Refer to Table 1) were measured with the use of sound level meter, which has measuring range 37-140 dB and the results obtained are as follows : 1. Capacity of the engine room becomes large according to the total H. P. of the main engine, but the vessels are using of a type of engine, i.e., 6 cylinder, and thus the noise, pressure has shown a tendency to become lower except Kwan-Ak-San Ho, Chuk-Yang Ho and Dong Bang Ho where the noise pressure was higher by 3 dB than curve of mean value. 2. The maximum noise pressure appeared even before the main engine reached the maximum r. p. m. and while the percentage of the r. p. m. varied depending on the vessel, the maximum noise appeared at around the $67-75\%$ of the r. p. m. 3. The maximum of noise pressure in the respective engine room ranged between 93.5-105 dB while it was between 72-81 dB at the fish process room in the stern trawl vessel where the oral communications were possible.

  • PDF

Development of a Method for Measuring Image Quality of Intra Vascular Ultrasound Images using Image Analysis Program (영상 분석 프로그램을 이용한 혈관 내 초음파 영상의 화질 측정 방법 고안)

  • Seo, Young-Hyun;Han, Jae-Bok;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.621-628
    • /
    • 2021
  • Prior studies on frequency-related image quality analysis of intravascular ultrasound catheters are lacking both in Korea and abroad. Therefore, this study was conducted to prepare a standard for measuring the image quality using the program and to suggest a measuring method to researchers related to the quality analysis of intravascular ultrasound images. For the target, the vessel lumen size is 3.0 - 4.0 mm. Before using intravascular ultrasound, thoroughly clean the ultrasound catheter so that no air or foreign substances enter it. Normal vascular images and lesion vascular images of sufficiently dilated images were used. As a standard image acquisition method, the image of the end-systolic section, which has the best evaluation of vascular lesions when using intravascular ultrasound, was acquired retrospectively through the DCAS PACS program to set the standard. When setting the measurement method criteria, we proposed a standard setting method that corresponds to the concentric and eccentric circles of normal and lesion vessels. By applying this criterion, we proposed a method for measuring the lumen and lateral cavities of normal and lesion vessels of interest and background area. In conclusion, if the image quality of intravascular ultrasonography is measured through the method devised by these researchers, consistent quality measurement is possible regardless of the type of intravascular ultrasound catheter. Therefore, it is thought that it can be applied as a guideline for the actual image quality measurement method in the study related to intravascular ultrasound image quality.

A Study on the Development of Shaft Power Measuring System (축계 마력 측정 시스템의 개발에 관한 연구)

  • Nam, T.K.;Lee, D.C.;Roh, Y.O.;Heo, G.S.;Choi, G.J.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.213-216
    • /
    • 2006
  • In this paper a development of shaft power measuring system for a small vessel is discussed. It is important that the exact power measurement of marine engine which is used for ship's propulsion since the engine power is related to ship's usage and its shaft design. Two gearwheel and magnetic sensors are adopted to measure torsional angle on the shaft. High resolution encoder is also applied to compensate the output signal from gearwheel. The calculation of shaft power is executed using measured signal and angular velocity of rotating machine and the result is plotted on the monitoring screen.

  • PDF

Sustainable Utilization and Management Scheme in Wangdol-cho Surrounding Sea Area (동해 왕돌초 어장의 지속적 이용 및 관리 방안)

  • Lee, Kwang-Nam;Myoung, Jung-Goo
    • Ocean and Polar Research
    • /
    • v.25 no.3
    • /
    • pp.331-345
    • /
    • 2003
  • The fishing ground surrounding Wangdol-cho is not only overexploited by the littering of dilapidated fishing net and equipment, but also by fishermen's overfishing, surpassing optimum fisheries resources. In addition, increasing fishing efforts (number of fishing vessel and fishing net, etc) contribute to the deterioration of fishing ground, and it is urgently required that schemes to tackle the problems should be taken. To effectively address the problems as such, this paper aims to propose sustainable utilization and management scheme of fishing ground through classification of fishing ground surrounding Wangdol-cho as one area which is less than 50m deep, measuring $13.66km^2$ and the other, permission fishing area of Gill Net fishery, measuring $347.23km^2$. The analysis shows that, for the water area less than 50m deep, implementation from a short-term perspective includes autonomous management fishery by gill net and trap fishery. For the permission fishing area of Gill Net fishery, implementation includes limit on fishing period, real name system of fishing equipment and limit on fishing equipment. Implementation from a medium and long-term perspective includes limit on scuba diving, designation of underwater sightseeing zone, sea farming, facilities of surveillance, adoption of approval system for the permission fishing area of Gill Net fishery and introduction of report system for fishing.

A STUDY OF THE DEVIATION-MEASURING METHOD & AUTOMATIC DEVIATION-CORRECTING APPARATUS (자차측정 방법 및 자동 자차수정 장치에 대한 연구)

  • Park, Hyuk;Park, Jin-woo;Kim, Boo-il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.181-184
    • /
    • 2016
  • This study is to compensate for inaccuracies in accordance with the change in the deviation correction value due to the movement and location of the ship cargo, equipment of the vessel, and eliminating the inconvenience of hand. By modifying the deviation through the simplification and automation was planned for accuracy and ease of modification of the modified value. The main method used is charted by measuring 24 direction and inputting the value of magnetic compass direction in automatic deviation-correcting apparatus manually or automaticallyThe measured values are exhibited in Table data and made it possible to calculate accurate correction value deviation. From this it can make deviation table having the margin of error within ${\pm}3^{\circ}$in all regions of the world And this table will help to navigational safety and economy under the unavailable or limited gyro contion.

  • PDF

State of the Art on GNSS Reflectometry and Marine Applications (위성신호 반사계측(GNSS-R) 기술 현황과 해양 응용분야)

  • Seo, Kiyeol;Park, Sang-Hyun;Park, Jihye
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.402-408
    • /
    • 2021
  • GNSS-Reflectometry (GNSS-R) is a technique for measuring and analyzing signals transmitted from satellites, reflecting on the surface of land or sea. GNSS-R is mainly used for measuring the water level variation, typhoon and meteorological anomaly, soil moisture, and snow depth. This paper describes the concept and measurement principle of GNSS-R technology, especially focusing on the field of marine utilization and its feasibility. In particular, it presents the applications of this technique for monitoring the safety of marine environment as well as the marine vessel and their utilization areas based on currently available infrastructure on the ground and maritime reference stations, such as the existing differential GNSS reference stations and integrity monitors (DGNSS RSIM), and GNSS reference station infrastructure, using the ground-based and the satellite-based GNSS-R approaches.

Usefulness of 3D Rotational Angiography for Cerebral Vascular Diameter Measurement (뇌혈관 직경측정을 위한 3차원 회전 혈관조영술의 유용성)

  • Seung-Gi, Kim;Sang-Hyun, Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.9-14
    • /
    • 2023
  • When measuring cerebrovascular with 3D rotational angiography, the accuracy was verified by comparing the actual size and measurement size, respectively. It is intended to help select therapeutic materials and instruments during cerebrovascular intervention by comparing the average error rates for measured values in the 3DRA and CTA methods by examining with protocols such as brain CTA, which are always performed in emergency situations. The mean error rate between the groups of measurers was ±3.655% for radiation technologist and ±3.331% for university students, and the mean error rate of the student group was within tolerance (±10%), and the independent sample T-test result t =0.879, p=0.394 (p>0.05) showed no statistically difference between the two. In addition, the average error rate measured by both groups by 3DRA was measured below ±5% within the tolerance error rate (±10%), and most of CTA was measured within the tolerance range (±10%), but showed an average error rate of up to 5.65%, and the independent sample T-test result was statistically more accurate than 3DRA. Both the 3DRA method and the brain CTA method for measuring cerebrovascular size could be accurately measured within tolerance, but it would be better to measure cerebrovascular blood vessels using a more accurate 3DRA method during cerebrovascular intervention.

UNDERWATER DISTRIBUTION OF VESSEL NOISE (선박소음의 수중분포에 관한 연구)

  • PARK Jung Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.10 no.4
    • /
    • pp.227-235
    • /
    • 1977
  • The noise pressure scattered underwater on account of the engine revolution of a pole and liner, Kwan-Ak-San(G. T. 234.96), was measured at the locations of Lat. $34^{\circ}47'N$, Long. $128^{\circ}53'E$ on the 16th of August 1976 and Lat. $34^{\circ}27'N$, Long. $128^{\circ}23'E$ on the 28th of July, 1977. The noise pressure passed through each observation point (Nos. 1 to 5), which was established at every 10m distance at circumference of outside hull was recorded when the vessel was cruising and drifted. In case of drifting, the revolution of engine was fixed at 600 r. p. m. and the noise was recorded at every 10 m distance apart from observation point No. 3 in both horizontal and vertical directions with $90^{\circ}$ toward the stern-bow line. In case of cruising, the engine was kept in a full speed at 700 r.p.m. and the sounds passed through underwater in 1 m depth were also recorded while the vessel moved back and forth. The noise pressure was analyzed with sound level meter (Bruel & Kjar 2205, measuring range 37-140 dB) at the anechoic chamber in the Institute of Marine Science, National Fisheries University of Busan. The frequency and sound waves of the noise were analyzed in the Laboratory of Navigation Instrument. From the results, the noise pressure was closely related to the engine revolution shelving that the noise pressure marked 100 dB when .400 r. p. m. and increase of 100 r. p. m. resulted in 1 dB increase in noise pressure and the maximum appeared at 600 r. p. m. (Fig.5). When the engine revolution was fixed at 700 r. p. m., the noise pressures passed through each observation point (Nos. 1 to 5) placed at circumference of out side hull were 75,78,76,74 and 68 dB, the highest at No.2, in case of keeping under way while 75,76,77,70 and 67 dB, the highest at No.3 in case of drifting respectively (Fig.5). When the vessel plyed 1,400 m distance at 700 r.p.m., the noise pressure were 67 dB at the point 0 m, 64 dB at 600m and 56 dB at 1,400m on forward while 72 at 0 m, 66 at 600 m and 57 dB at 1,400 m on backward respectively indicating the Doppler effects 5 dB at 0 m and 3 dB at 200 m(Fig.6). The noise pressures passed through the points apart 1,10,20,30,40 and 50 m depth underwater from the observation point No.7 (horizontal distance 20 m from the point No.3) were 68,75,62,59,55 and 51 dB respectively as the vessel was being drifted maintaining the engine revolution at 600 r. p. m. (Fig. 8-B) whereas the noise pressures at the observation points Nos.6,7,8,9 and 10 of 10 m depth underwater were 64,75,55,58,58 and 52 dB respectively(Fig.8-A).

  • PDF

A Comparative Study on Ice Load Characteristics between General and Ice-breaking Operations in Ice-covered Waters (빙해지역 일반 운항 및 쇄빙 운항 시의 빙하중 특성 비교 연구)

  • Lee, Min-Woo;Kwon, Yong-Hyeon;Rim, Chae-Whan;Lee, Tak-Kee
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.28-33
    • /
    • 2015
  • The icebreaking research vessel ARAON had her second ice trial in the Arctic Ocean from July 16 to August 12, 2010. In this study, the ice loads measured during the “general” operation and “ice breaking” operation in ice-covered waters were analyzed and compared. Whereas the “general” operation stands for the voyage in the water partially covered by ice, the “ice breaking” operation involved substantial ice floes for the ice breaking performance test. Based on the measured data, comparisons of the relationship between the ship speed and ice load, and between the locations of strain gauges and ice loads were investigated. Peak stresses higher than 20 MPa were found. The longitudinal and vertical correlations between the measurement location and ice load were analyzed, and the probability of peak stress was calculated. As a result, the probability function for higher ice loads during both operation modes was expressed in an exponential and power forms.

The Effects of Wall Elasticity on Wall Shear Rate of a Divergent Tube (Vascular Graft) (벽 탄성도가 확장관(인조혈관) 벽 전단변형률에 미치는 영향)

  • Rhee, Kye-Han;Lee, Sang-Man
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.6 s.165
    • /
    • pp.912-921
    • /
    • 1999
  • Shear stress acting on the arterial wall by blood flow is an important hemodynamic factor influencing blocking of blood vessel by thickening of an arterial wall. In order to study the effects of wall elasticity on the wall shear rate distribution in an artery-divergent graft anastomosis, a rigid and a elastic model are manufactured. These models are placed in a pulsatile flow loop, which can generate the desired flow waveform. Flow visualization method using a photochromic dye is used to measure the wall shear rate distribution. The accuracy of measuring technique is verified by comparing the measured wall shear rate in the straight portion of a model with the theoretical solution. Measured wall shear rates depend on the wall elasticity and flow waveform. The mean and maximum shear rate in the elastic model are lower than those in rigid model, and the decreases are more significant near the end of a divergent tube. The reduction of mean and maximum of wall shear rate in an elastic model are up to 17 percent.