• Title/Summary/Keyword: measuring impedance

검색결과 321건 처리시간 0.021초

방오도료 도막의 마모율과 분극특성의 상관관계에 관한 평가 (Evaluation on the Rlationship between Wear Ratio and Polarization Characteristics of Anti-Fouling Paint)

  • 정재현;문경만;원종필;박동현;;김현명;이명훈;백태실
    • Corrosion Science and Technology
    • /
    • 제13권1호
    • /
    • pp.15-19
    • /
    • 2014
  • Recently, anti-fouling paints which does not include the poison components such as tin(Sn), copper(Cu) have been increasingly developed in order to inhibit the environmental contamination of the sea water. Moreover, the wear ratios of these anti-fouling paints are very important problem to prolong their life time in economical point of view. In this study, five types of anti-fouling paints as self polishing type were investigated on the relationship between their polarization characteristics and wear ratios. It was verified that there was apparently a good relationship between the wear ratio and polarization characteristics, for example, the wear ratio increased with increasing the impedance ratio, and increased or decreased with the corrosion potential shifting in the negative or positive direction respectively. In addition, the wear ratio decreased with decreasing the corrosion current density. Consequently, it is suggested that we can qualitatively expect the wear ratio by only measuring the polarization characteristics. Therefore, before the examination of the wear ratio was actually carried out in the field, the evaluation of polarization property in the laboratory may give a available reference data for their developments.

공진법 기반의 [011] 분극 Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 압전단결정 물성규명 (Characterization of [011] Poled Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 Single Crystals by Resonance Method)

  • 제엽;심민섭;조요한;이원옥;이상구;이정민;서희선
    • 한국전기전자재료학회논문지
    • /
    • 제34권6호
    • /
    • pp.466-474
    • /
    • 2021
  • [011] poled ternary Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 (PIN-PMN-PT) single crystals have been investigated for active materials for acoustic transducers because of their high piezoelectric properties in both shear and transverse modes. In order to use [011] poled PIN-PMN-PT single crystals for acoustic transducers, the characterization of full-matrix material properties is required. In this study, full sets of compliance, dielectric, and piezoelectric constants of [011] poled rhombohedral PIN-PMN-PT were measured by a resonance method. Dimensions and geometries of 12 samples were proposed for measuring 17 independent material constants of [011] poled rhombohedral PIN-PMN-PT single crystals. Two sets of samples with different PT concentrations, 0.24PIN-0.49PMN-0.27PT and 0.24PIN-0.46PMN-0.30PT, were fabricated and their material properties were measured. Measured impedance spectra and simulated impedance spectra of the samples were compared to check the accuracy of the measurements.

Thickness evaluation of Cr coating fuel rod using encircling ECT sensor

  • Park, Jeong Won;Ha, Jong Moon;Seung, Hong Min;Jang, Hun;Choi, Wonjae
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3272-3282
    • /
    • 2022
  • To improve the safety and life extension qualities of nuclear fuel rods which is currently made of zirconium (Zr) alloy, research on the application of chromium (Cr) coating was conducted. Cr coating has advantages such as increased corrosion resistance and reduced oxidation rate, but non-destructive thickness evaluation studies are needed to ensure the reliability of the steps taken to provide uniform coating thickness. Eddy current testing (ECT) is a representative non-destructive technique for such as thickness evaluation and surface defect inspection. To inspect changes in thickness at micron scale, the Swept Frequency Eddy Current Testing (SFECT) method was applied to select a frequency range sensitive to changes in thickness. The coating thickness was evaluated using changes in signals, such as that for impedance. In this study, basic research was performed to evaluate the thickness of the Cr coating on a rod using an encircling sensor and the SFECT technique. The sensor design parameters were determined through simulation, after which the new sensor was manufactured. A sensor capable of measuring the thickness of a non-uniformly Cr-coating rod was selected through an experiment evaluating the performance of the manufactured sensor. This was done using the impedance-difference of a Cr-coating rod and a Zr alloy rod. The possibility of evaluation of the Cr coating thickness was confirmed by comparing the experimental results with the selected sensor and the signals of the measured Cr-coating rod. All simulation results were verified experimentally.

Science Objectives and Design of Ionospheric Monitoring Instrument Ionospheric Anomaly Monitoring by Magnetometer And Plasma-probe (IAMMAP) for the CAS500-3 Satellite

  • Ryu, Kwangsun;Lee, Seunguk;Woo, Chang Ho;Lee, Junchan;Jang, Eunjin;Hwang, Jaemin;Kim, Jin-Kyu;Cha, Wonho;Kim, Dong-guk;Koo, BonJu;Park, SeongOg;Choi, Dooyoung;Choi, Cheong Rim
    • Journal of Astronomy and Space Sciences
    • /
    • 제39권3호
    • /
    • pp.117-126
    • /
    • 2022
  • The Ionospheric Anomaly Monitoring by Magnetometer And Plasma-probe (IAMMAP) is one of the scientific instruments for the Compact Advanced Satellite 500-3 (CAS 500-3) which is planned to be launched by Korean Space Launch Vehicle in 2024. The main scientific objective of IAMMAP is to understand the complicated correlation between the equatorial electro-jet (EEJ) and the equatorial ionization anomaly (EIA) which play important roles in the dynamics of the ionospheric plasma in the dayside equator region. IAMMAP consists of an impedance probe (IP) for precise plasma measurement and magnetometers for EEJ current estimation. The designated sun-synchronous orbit along the quasi-meridional plane makes the instrument suitable for studying the EIA and EEJ. The newly-devised IP is expected to obtain the electron density of the ionosphere with unprecedented precision by measuring the upper-hybrid frequency (fUHR) of the ionospheric plasma, which is not affected by the satellite geometry, the spacecraft potential, or contamination unlike conventional Langmuir probes. A set of temperature-tolerant precision fluxgate magnetometers, called Adaptive In-phase MAGnetometer, is employed also for studying the complicated current system in the ionosphere and magnetosphere, which is particularly related with the EEJ caused by the potential difference along the zonal direction.

골재 종류별 시멘트 경화체 계면의 전기저항 특성 (Electrical Resistivity of ITZ According to the Type of Aggregate)

  • 김호진;배제현;정용훈;박선규
    • 한국건설순환자원학회논문집
    • /
    • 제9권3호
    • /
    • pp.268-275
    • /
    • 2021
  • 콘크리트의 강도를 결정하는 3가지 요인은 시멘트 페이스트의 강도, 골재의 강도, 골재와 시멘트페이스트 계면영역의 강도가 있다. 이 중 계면영역의 강도가 가장 취약하다. ITZ(Interfacial Transition Zone)는 10~50㎛로 형성되며, 수산화칼슘의 비율은 높아지고, CSH는 낮은 비율을 나타낸다. 높은 수산화칼슘 비율은 ITZ의 부착강도 저하의 원인이 된다. 이로인해 ITZ는 더 약한 영역이 된다. ITZ의 문제점은 경량골재를 활용할 때 더 불리한 요소로 나타난다. 계면특성의 기존연구는 계면파괴인성을 측정하고, 계면에 영향을 주는 인자들을 파악했고, 굵은 골재를 사용하지 않은 시멘트 경화체에 SEM과 XRD분석을 진행했다. 또한 EMPA-BSE장비를 활용하여 미세구조를 파악하였다. 하지만 기존의 연구에서는 미세구조와 역학적 성질 파악에 어려움이 있다. 따라서 본 연구에서는 천연골재와 경량골재 계면을 파악하기 위해 EIS측정 장비를 활용하여 전기저항을 측정하는 방식을 채택하였고, 경량골재 겉면을 고로슬래그 코팅을 통해 계면상태의 변화를 실험하였다. 실험결과, 천연골재와 경량골재의 압축강도는 밀도가 높은 천연골재 높은 강도를 나타냈고, 경량골재 표면 코팅 시 천연골재 이상의 강도를 나타냈으며, 골재 종류별 전기저항의 차이를 보였다.

EIS를 활용한 경량골재 종류별 시멘트 경화체의 계면특성 분석 (ITZ Analysis of Cement Matrix According to the Type of Lightweight Aggregate Using EIS)

  • 김호진;정용훈;배제현;박선규
    • 한국건설순환자원학회논문집
    • /
    • 제8권4호
    • /
    • pp.498-505
    • /
    • 2020
  • 골재는 콘크리트 체적의 약 70~85%를 차지하며, 콘크리트의 건조수축을 저감시켜주는 필수요소이다. 하지만 고층건축물 건설시 천연골재의 높은 하중으로 인해 문제점으로 작용한다. 고층 건물 건설시 하중이 커지게 되면 크리프가 발생하고 지반이 침식될 우려가 있으므로 기초를 크게 설계하고 암반층까지 깊게 내린 지정이나 파일등을 설치해야 하므로 공사비 및 재료비가 늘어 경제적 문제점이 있다. 콘크리트의 하중을 줄이기 위해 골재의 경량화를 진행하고 있다. 하지만 인공경량골재는 천연 골재에 비해 높은 흡수율과 낮은 부착강도로 인해 골재와 페이스트 사이의 계면에 영향을 주고 콘크리트 전체 강도에 영향을 미친다. 따라서 본 연구에서는 천연골재와 경량골재 종류별 계면을 파악하기 위해 비파괴 실험인 EIS측정 장비를 활용하여 전기저항을 측정하는 방식을 채택하였고, 경량골재 겉면을 고로슬래그 코팅을 통해 계면상태의 변화를 실험하였다. 실험결과, 골재 종류별 및 코팅유무에 따른 압축강도의 차이를 보였고, 경량골재 종류별 임피던스 값과 위상각의 차이를 보였다.

암석 시료의 유도분극 측정을 위한 전극배열 비교 (A Study on Electrode Array for Measurement of Induced Polarization of Rock Samples)

  • 한만호;이정환;이근수;이명종
    • 터널과지하공간
    • /
    • 제33권6호
    • /
    • pp.483-494
    • /
    • 2023
  • 국내에서 널리 사용되는 전기비저항과 유도분극탐사는 지하 매질 정보를 얻는 대표적인 물성인 전기적 성질을 측정하는 방법이다. 다양한 현장에서 획득하는 탐사 자료에 대한 정밀한 해석을 위해서는 매질의 물성 정보를 정확하게 측정하는 것이 중요하다. 암석의 전기적 물성 측정은 전류 전극과 전위 전극을 동일한 전극으로 사용하는 2전극법과 전류 전극과 전위 전극을 분리하여 측정하는 4전극법으로 구분된다. 2전극법은 4전극법에 비해 시료와 전극의 접촉이 매우 용이하므로 일반적으로 많이 사용되고 있지만, 시료뿐만 아니라 전극의 임피던스가 함께 측정된다는 문제가 있다. 이 연구에서는 유도분극 특성을 갖지 않는 물시료와 유도분극 특성을 갖는 흑연과 시멘트를 혼합한 인공 시료에 대하여 2전극법과 4전극법을 사용하여 시간영역 유도분극 효과를 측정하고 그 결과를 비교하였다. 또한, 현장탐사를 모사한 수조모형 실험으로 두 전극법의 결과와 비교하여, 모형실험과 4전극법의 결과가 잘 일치하는 것을 확인하였다. 따라서, 4전극법이 전위전극의 설치에 어려움이 있지만 2전극법에 비해 전위전극의 임피던스에 의한 문제를 줄일 수 있어 전기적 물성 측정에 효과적임을 확인하였다.

AC 임피던스 분석법을 이용한 K+ 이온선택성 PVC막 전극 특성 (Electrode Characteristics of K+ Ion-Selective PVC Membrane Electrodes with AC Impedance Spectrum)

  • 김용렬;안형환;강안수
    • 공업화학
    • /
    • 제9권6호
    • /
    • pp.870-877
    • /
    • 1998
  • 본 연구에서는 임피던스 스펙트럼 분석법을 사용하여 중성운반체로 dibenzo-18-crown-6 (D18Cr6)와 valinomycin (Val)을 이용하여 $K^+$이온선택성 PVC막 전극의 막과 용액계면에서의 임피던스 특성을 검토하였다. PVC막에 대한 운반체의 종류와 함량, 가소제, 막두께, 기본전해질의 혼입(doping)여부 및 이온의 농도변화 등을 교류임피던스 분석법을 이용하여 측정하였고, 그 결과를 전극특성과 비교 검토하고 PVC막 전극에서의 전달특성을 규명하였다. 교류 임피던스의 특성을 측정하여 중성운반체로 D18Cr6와 Val을 포함하고 있는 PVC막 전극의 등가회로는 막의 벌크저항과 전기이중층 용량을 포함하는 기하학적용량을 병렬로 하고, 용액저항과 직렬로 구성되는 임피던스의 등가회로임을 확인할 수 있었다. 그러나 저농도 및 저주파수 영역에서 약간의 전하전이저항과 Warburg저항이 나타나 중첩되는 것을 알 수 있었다. $K^+$이온선택성 전극에서 운반체로서 D18Cr6가 Val중 D18Cr6가 기존의 Val보다 전극특성 및 임피던스 특성이 좋았으며 특히 D18Cr6에 기본전해질로 potassium tetraphenylborate (TPB)를 첨가한 경우 이상적인 전극을 제조할 수 있었다. 운반체의 최적 함량은 D18Cr6와 Val의 경우 3.23wt%부근이었고, 가소제는 DBP가 가장 적절하였다. 막두께가 얇아질수록 임피던스 특성이 좋아졌으나, 막두께가 최적 막두께 이하로 얇아지면 전극특성이 나빠짐을 알 수 있었다. D18Cr6의 경우 $K^+$이온에 대한 혼합용액법에 의한 선택계수 서열은 다음과 같았다. $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

압전감쇠를 통한 압전단일패널의 전달 소음저감성능 (Transmitted Noise Reduction Performance of Piezoelectric Single Panel through Piezo-damping)

  • 이중근;김재환;김기선;이형식
    • 한국산학기술학회논문지
    • /
    • 제2권2호
    • /
    • pp.49-56
    • /
    • 2001
  • 저주파공진에서의 소음저감을 위한 압전단일패널에 대한 실험적 연구를 수행하였다. 압전단일패널은 압전재료를 평판 구조물에 부착하고, 션트회로를 압전재료에 연결한 구조물이다. 구조물의 저주파공진에서의 전달 소음저감을 위하여 압전감쇠를 이용하였다. 압전감쇠의 파라메터 튜닝은 제안한 새로운 방법을 적용하였다. 이 방법은 전기적 임피던스모델을 기초로 하여 공진회로에서 에너지 소산이 최대가 되도록 하는 방법으로 구조물에 부착된 압전재료에서 전기적 임피던스를 측정하여 시스템의 공진주파수 근처에서 등가 전기 회로를 구성하였다. 압전감쇠를 위한 공진션트 회로는 직렬로 연결된 저항과 인덕터로 구성되었으며, 저항과 인덕터는 회로에서 소산되는 에너지가 최대가 될 수 있는 값으로 최적설계 하였다. 압전단일패널의 전달 소음저감성능은 음향터널을 이용하여 실험을 수행하였다. 음향터널은 사각단면이며 소음 원으로 터널의 한 쪽 끝에 스피커가 설치되었다. 패널은 터널의 중앙에 설치하여 투과 음압을 측정하였다. 압전감쇠를 통하여, 공진주파수에서의 좋은 소음 저감을 얻었다. 압전감쇠를 이용한 압전단일패널은 간단하고 경계적인 측면에서 소음 저감을 위한 유망한 기술이다.

  • PDF

자동 보정 주파수 의존형 근관장 측정기의 개발 (Development of a Frequency Dependent Type Apex Locator with Automatic Compensation)

  • 김덕원;남기창;김영주;이승종
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권6호
    • /
    • pp.595-602
    • /
    • 1998
  • 근관장 측정기 중 주파수 의존형이 다른 방법보다 정확도도 높고 사용이 간편한 것으로 평가되고 있다. 그러나 주파수 의존형 또한 실제 임상 사용시 근관내의 전해질 유무에 영향을 받는다. 본 연구에서는 전해질의 영향을 최소화한 자동 보정 주파수 의존형 전자 근관장 측정기를 개발하였다. 또한 500Hz와 10kHz가 임피던스 측정을 위해 사용되는 교류신호로써 측정오차를 최소화하는 최적 주파수임을 상품화된 제품의 주파수(400Hz, 8kHz)와 비교하여 확인하였으며, 신호의 파형에 따른 통계적 유의성은 없었다(p>0.05). 두 신호의 임피던스 비는 파일의 근관 내의 위치를 알려주고, 본 연구에서 적용한 두 신호의 전압차는 근관내 용액의 상태를 나타내 준다. 전압차를 이용하여 보정한 결과 측정오차를$H_2O_2$ 용액에서는 평균 +0.54mm에서 +0.18mm로(p<0.01), NaOCl 용액에서는 평균 -0.33mm에서 -0.01mm로(p<0.01) 줄일 수 있었다. 정확도는 허용오차를 ${\pm}$0.5mm를 기준으로 할 때, $H_2O_2$ 용액에서는 71.1%에서 91.1%로, NaOCl 용액에서는 82.2%에서 100%로 향상시켰다.

  • PDF