• Title/Summary/Keyword: mean value property

Search Result 119, Processing Time 0.032 seconds

A STUDY ON WEAR RESISTANCE OF FLOWABLE COMPOSITE RESINS (유동성 복합레진의 마모저항성에 관한 연구)

  • Yun, Yeon-Hee;Kim, Jung-Wook;Lee, Sang-Hoon;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.217-225
    • /
    • 2002
  • When we use the flowable resin on the primary molars for quick handling, one of the most important property is the wear resistance. This study was performed to compare the wear resistance characteristics of four flowable composite resins [Arabesk flow (group 1), Tetric flow (group 2), Aeliteflow (group 3), Filtek flow (group 4)] to that of one control composite resin [Z100 (group 5)]. Specimen discs(n=10), 10mm wide and 2mm thick, were stored in distilled water at $37^{\circ}C$ for 7 days prior to testing. The specimens were subjected to 50,000 strokes at 2 Hz on the MTS system. During the test, the following parameters were maintained: the lateral excursion at 0.4mm, occlusal force at 2-100N with a force profile in the form of a half sine wave. The measurements of volume loss, depth of wear, and Vicker's hardness number of composite resins, and SEM observations of the polished and abraded surfaces were established. One-way ANOVA and Scheffe's multiple comparison test were employed to detect statistically significant differences among the flowable composite resin groups and the control composite group at P<.05. The following results were obtained: 1. Group 3 showed the least volume loss, while group 4 showed the greatest. The mean volume loss increased in the following order: group 3

  • PDF

Comparison of the mechanical properties and microstructures of fractured surface for Co-Cr alloy fabricated by conventional cast, 3-D printing laser-sintered and CAD/CAM milled techniques (주조, 3-D printing을 활용한 laser sintered 및 CAD/CAM milled 기법을 이용하여 제작된 코발트-크롬 합금의 물리적 성질 및 파절 단면 관찰 비교 연구)

  • Choi, Yun-Jung;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Ahn, Jin-Soo;Park, Dong-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.67-73
    • /
    • 2014
  • Purpose: The purpose of present study is to compare mechanical properties and microstructural characteristics of fractured surface for cast, 3-D printing laser sintered and CAD/CAM milled cobalt-chromium (Co-Cr) alloy specimens and to investigate whether laser sintered technique is adequate for dental applications. Materials and methods: Thirty six flat disc shape Co-Cr alloy specimens were fabricated for surface hardness test and divided into three groups according to the manufacturing methods; 12 specimens for casting (n=12), 12 specimens for laser sintered technology (n=12) and 12 specimens for milled technology (n=12). Twelve dumbbell shape specimens for each group were also fabricated for a tensile test. Statistical comparisons of the mechanical properties for the alloys were performed by Kruskal-Wallis test followed by Mann-Whitney and Bonferroni test. The microstructural characteristics of fractured surfaces were examined using SEM. Results: There were significant differences in the mean Vickers hardness values between all groups and the cast specimen showed the highest (455.88 Hv) while the CAD/CAM milled specimen showed the lowest (243.40 Hv). Significant differences were found among the three groups for ultimate tensile strength, 0.2% yield stress, elongation, and elastic modulus. The highest ultimate tensile strength value (1442.94 MPa) was shown in the milled group and the highest 0.2% yield strength (1136.15 MPa) was shown in the laser sintered group. Conclusion: Different manufacturing methods influence the mechanical properties and microstructure of the fractured surfaces in Co-Cr alloys. The cast Co-Cr alloy specimens showed the highest Vickers hardness, and the CAD/CAM milled specimens revealed the highest tensile strength value. All alloys represent adequate mechanical properties satisfying the ISO standards of dental alloy.

Quality Properties of Capsule Type Meju Prepared with Aspergillus oryzae (Aspergillus oryzae를 이용한 캡슐형 메주의 품질특성)

  • 최재훈;권선화;이상원;남상해;최상도;박석규
    • Food Science and Preservation
    • /
    • v.10 no.3
    • /
    • pp.339-346
    • /
    • 2003
  • In order to improve some problems such as contamination of undesirable mold, mycotoxin production and excessive drying on the surface of traditional meju, we developed a capsule type-meju(CM) coated with steamed black bean and Aspergillus oryzae - rice koji(0.3%, w/w) mixture to surface of traditional meju and fermented at 25$^{\circ}C$ for 14 days under 80% relative humidity. Contamination of undesirable mold on the surface of CM was not detected within 2 weeks and some genus Penicillium molds on control meju without koji were found naturally after 12 days of fermentation. The moisture content of meju was showed to be in the range of 34.7 - 29.4% being 32.7%(w/w) of mean value. Titratable acidities in CMs prepared with black bean(BCM) and soybean(SCM) were much higher than that in control meju, and BCM was similar to SCM. Free sugar content in BCM(123.98 mg%) was 10 times and 2.1 times higher than that in control meju(15.02 mg%) and SCM(59.85 mg%), respectively. Amino type nitrogen content in control meju was 147.00 mg% and its content in BCM(255.50 mg%) was 1.37 times higher than that in SCM(187.25 mg%). Total organic acid content in BCM(95.98 mg%) and SCM(1l9.98 mg%) were much higher than that in control meju(26.44 mg%), and then lactic and malic acid contents were markedly changed according to capsulation of meju. Lightness value(L) of Hunter color index was much higher in BCM than in SCM. Fatty acid composition of CM was not different as compared to control meju. Total free amino acid content in BCM(1039.70 mg%) was 4.4 times and 2.4 times higher than that in control meju(236.45 mg%) and SCM(556.07 mg%), respectively.

The study of heavy rain warning in Gangwon State using threshold rainfall (침수유발 강우량을 이용한 강원특별자치도 호우특보 기준에 관한 연구)

  • Lee, Hyeonjia;Kang, Donghob;Lee, Iksangc;Kim, Byungsikd
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.751-764
    • /
    • 2023
  • Gangwon State is centered on the Taebaek Mountains with very different climate characteristics depending on the region, and localized heavy rainfall is a frequent occurrence. Heavy rain disasters have a short duration and high spatial and temporal variability, causing many casualties and property damage. In the last 10 years (2012~2021), the number of heavy rain disasters in Gangwon State was 28, with an average cost of 45.6 billion won. To reduce heavy rain disasters, it is necessary to establish a disaster management plan at the local level. In particular, the current criteria for heavy rain warnings are uniform and do not consider local characteristics. Therefore, this study aims to propose a heavy rainfall warning criteria that considers the threshold rainfall for the advisory areas located in Gangwon State. As a result of analyzing the representative value of threshold rainfall by advisory area, the Mean value was similar to the criteria for issuing a heavy rain warning, and it was selected as the criteria for a heavy rain warning in this study. The rainfall events of Typhoon Mitag in 2019, Typhoons Maysak and Haishen in 2020, and Typhoon Khanun in 2023 were applied as rainfall events to review the criteria for heavy rainfall warnings, as a result of Hit Rate accuracy verification, this study reflects the actual warning well with 72% in Gangneung Plain and 98% in Wonju. The criteria for heavy rain warnings in this study are the same as the crisis warning stages (Attention, Caution, Alert, and Danger), which are considered to be possible for preemptive rain disaster response. The results of this study are expected to complement the uniform decision-making system for responding to heavy rain disasters in the future and can be used as a basis for heavy rain warnings that consider disaster risk by region.

Bioactivities and Isolation of Functional Compounds from Decay-Resistant Hardwood Species (고내후성 활엽수종의 추출성분을 이용한 신기능성 물질의 분리 및 생리활성)

  • 배영수;이상용;오덕환;최돈하;김영균
    • Journal of Korea Foresty Energy
    • /
    • v.19 no.2
    • /
    • pp.93-101
    • /
    • 2000
  • Wood of Robinia pseudoacacia and bark of Populus alba$\times$P. glandulosa, Fraxinus rhynchophylla and Ulmus davidiana var. japonica were collected and extracted with acetone-water(7:3, v/v) in glass jar to examine whether its bioactive compounds exist. The concentrated extracts were fractionated with hexane, chloroform, ethylacetate and water, and then freeze-dried for column chromatography and bioactive tests. The isolated compounds were sakuranetin-5-O-$\beta$-D-glucopyranoside from Populus alba $\times$Pl glandulosa, 4--ethyoxy-(+)-leucorobinetinidin frm R. pseudoacacia and fraxetion from F. rhynchophylla and were characterized by $^1H$ and$^{13}C $ NMR and positive FAB-MS. Decay-resistant activity was expressed by weight loss ratio and hyphae growth inhibition in the wood dust agar medium inoculated wood rot fungi. R. pseudoacacia showed best anti-decaying property in both test and its methanol untreated samples, indicating higher activity than methanol treated samples in hyphae grwoth test. In antioxidative test, $\alpha$-tocopherol, one of natural antioxidants, and BHT, one of synthetic antioxidants, were used as references to cmpare with the antioxidant activities of the extacted fractions. Ethylacetate fraction of F. rhynchophylla bark indicated the hightest activity in this test and all fractions of R. pseudiacacia extractives also indicated higher activities compared with the other fractions. In the isolated compounds, aesculetin isolated from F. rhynchophylla bark showed best activity and followed by robonetinidin from R. pseudoacaica.

  • PDF

A Study of the Characteristics of Heavy Rainfall in Seoul with the Classification of Atmospheric Vertical Structures (대기연직구조 분류에 따른 서울지역 강한 강수 특성 연구)

  • Nam, Hyoung-Gu;Guo, Jianping;Kim, Hyun-Uk;Jeong, Jonghyeok;Kim, Baek-Jo;Shim, Jae-Kwan;Kim, Byung-Gon
    • Journal of the Korean earth science society
    • /
    • v.40 no.6
    • /
    • pp.572-583
    • /
    • 2019
  • In this study, the atmospheric vertical structure (AVS) associated with summertime (June, July, and August) heavy rainfall in Seoul was classified into three patterns (Loaded Gun: L, Inverted V: IV, and Thin Tube: TT) using rawinsonde soundings launched at Osan from 2009 to 2018. The characteristics of classified AVS and precipitation property were analyzed. Occurrence frequencies in each type were 34.7% (TT-type), 20.4% (IV-type), 20.4% (LG-type), and 24.5% (Other-type), respectively. The mean value of Convective Available Potential Energy (1131.1 J kg-1) for LG-types and Storm Relative Helicity (357.6 ㎡s-2) for TT-types was about 2 times higher than that of other types, which seems to be the difference in the mechanism of convection at the low level atmosphere. The composited synoptic fields in all cases showed a pattern that warm and humid southwesterly wind flows into the Korean Peninsula. In the cases of TT-type, the low pressure center (at 850 hPa) was followed by the trough in upper-level (at 500 hPa) as the typical pattern of a low pressure deepening. The TT-type was strongly influenced by the low level jet (at 850 hPa), showing a pattern of connecting the upper- and low-level jets. The result of analysis indicated that precipitation was intensified in the first half of all types. IV-type precipitation induced by thermal instability tended to last for a short term period with strong precipitation intensity, while TT-type by mechanical instability showed weak precipitation over a long term period.

Physicochemical Properties of Commercial Sweet Potato Starches (시판 고구마전분의 이화학적 특성)

  • Baek, Man-Hee;Cha, Dong-Su;Park, Hyun-Jin;Lim, Seung-Taik
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.755-762
    • /
    • 2000
  • Physicochemical properties of commercial sweet potato starches manufactured by 7 different companies were investigated in comparison with corn and potato starches. Crude ash and protein content varied from 0.36 to 1.02%, and from 0.04 to 0.14% based on dry weight, respectively. The protein contents were relatively smaller than that of corn or potato starch. But whiteness of the sweet potato starches was less than that of corn or potato starch. Mean diameter of the sweet potato starch granules varied from 14.23 to $21.08\;{\mu}m$ depending on the company and all sweet potato starches showed bimodal size distributions. Pasting viscosity measured by Rapid Viscoanalyzer(RVA) also showed variations among the starches of different companies. The starch from D company in Korea had the lowest pasting temperature$(74.00^{\circ}C)$ whereas the starch from a phillippine company(P) did the highest one$(80.35^{\circ}C)$. The peak viscosity of sweet potato starches was higher than that of corn starch but lower than that of potato starch. The D company starch also showed the highest peak viscosity(2283 cp) among the starches tested. Paste breakdown by hot shearing ranged from 524 cp (S company) to 1279 cp (HL company). Textural properties of the starch gels appeared significantly different among the starches of different manufacturers. The greatest hardness of the gel was $137.90\;g_{f}$ at 1 day storage whereas the lowest value was $31.53\;g_{f}$. Except the starches from 2 companies (P and S), the sweet potato starches formed very soft and weak gels. P or S company starches formed the gels similar to potato starch. Syneresis by freeze-thawing treatments appeared less for sweet potato starch gels than that for corn starch gels, but greater than that for potato starch gel. The overall properties of the sweet potato starches varied by the manufacturing companies, and ranged between those of corn and potato starches.

  • PDF

Thermal Property and Fire Resistance of Cellulose Insulation (섬유질 단열재의 열적 특성 및 내화성능)

  • Kwon, Young-Cheol;Seo, Seong Yeon;Kim, Sung Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.203-212
    • /
    • 2005
  • Cellulose insulation is primarily manufactured from recycled newsprint and treated with fire retardants for the fire resistance. Thanks to the fire retardants, it is not combustible and flammable. In addition to that, Its thermal resistance is much better than that of fiberglass or rock wool. It is made from waste paper and easily decayed when it is demolished, and it has small embodied energy. So it is very environment-friendly building material. For broader use of cellulose insulation in buildings in Korea, it is necessary to test its physical performance to compare the results with the requirements on the Korean Building Code. To this end, apparent thermal conductivity (ka) measurements of Korean-made loose-fill cellulose insulations were recently completed using equipment that was built and operated in accordance with ASTM C 518 and the fire resistance was tested in accordance with ASTM C 1485. Korean loose-fill cellulose has thermal conductivity about 5% greater than the corresponding U.S. product at the same density. This is likely due to differences in the recycled material being used. Both spray-applied and loose-fill cellulose insulation lose about 1.5% of their thermal resistivity for $5.5^{\circ}C$ increase in temperature. The fire resistance of cellulose insulation is increased in linear proportion to the increase of the rate of fire retardant. Thanks to the high fire resistance, cellulose insulation can be used as a substitution of Styrofoam or Urethane foam which is combustible. The thermal conductivity of cellulose insulation was $0.037-0.043W/m{\cdot}K$ at the mean specimen temperature from $4-43^{\circ}C$. It corresponds to the thermal resistance of "Na Grade" according to the Korean Building Code. The effect of chemical content on thermal conductivity was negligible for all but the chemical-free specimen which had the highest value for the thermal conductivity over the temperature range tested. The thermal resistance of cellulose insulation is better than that of fiberglass or rock wool, and its fire resistance is higher than that of Styrofoam or Urethane foam. Therefore it can be substituted for those above considering its physical performance. Cellulose insulation is no more expensive than Styrofoam or rock wool, so it is recommended to use it more widely in Korea.

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.