• Title/Summary/Keyword: mean torque

Search Result 191, Processing Time 0.022 seconds

An Experimental Study on the Performance and Emission Characteristics of Diesel Engine Fuelled with a Blend of Ethanol (에탄올을 혼합한 디젤기관의 성능과 배기특성에 관한 실험적 연구)

  • PARK, JUN YOUNG;HAN, SUNG BIN;CHUNG, YON JONG
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.6
    • /
    • pp.721-726
    • /
    • 2016
  • Alcohols are particularly attractive as alternative fuels because they are a renewable resource. This paper describes the performance and emission characteristics of ethanol and diesel blended fuels in a compression ignition engine. This experimental results showed that ethanol diesel blended fuels decreased the torque and brake mean effective pressure. And experimental results indicated that using ethanol-diesel blended fuel, smoke, CO and HC emissions decreased as a result of the ethanol addition.

Characteristics of EMG Median Frequency and Torque During Isometric Back Extension Exercises (등척성 요추 신전운동 시 중앙주파수와 토크의 특성)

  • Kang, S. J.;Park, S. J.;Jang, K.;Park, K. H.;Kwon, O. Y.;Kim, Y. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • Localized muscle fatigue can be identified by a downward shift of the EMG frequency typically represented by a fall in the median frequency The Present experimental study was Performed to investigate the time change of the median frequency and the muscle torque during maximal isometric back extension exercises at different exercise angles (0$^{\circ}$, 12$^{\circ}$, 36$^{\circ}$and 72$^{\circ}$) Twenty heath subjects (mean age : 24.35 $\pm$ 2.70) were Participated in this study Median frequency was extracted from EMG signals by employing the fast Fourier transform. Initial median frequency and the slope of median frequency was not significantly correlated with the muscle torque. Pearson's Product moment correlation was used to quantify the relationship between slopes of median frequency and torque. The results may suggest that the exorcise angle during maximal isometric back extension exercises does not affect the slopes of the median frequency and torque, and y-intercept of the median frequency among exercise angles There was no significant correlation between slopes of median frequency and torque. But there was a moderate correlation between median frequency and torque at each exercise angle. In conclusion, the exercise angle during maximal isometric back extension exercise is not a direct effect on slopes of median frequency and torque. But results showed that the shift of median frequency and torque shift were highly correlated in all subjects.

The reliability of Anycheck device related to healing abutment diameter

  • Lee, Dong-Hoon;Shin, Yo-Han;Park, Jin-Hong;Shim, Ji-Suk;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.83-88
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). MATERIALS AND METHODS. Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck). (2) Five different diameters (4.0, 4.5, 4.8, 5.5, and 6.0 mm) of healing abutments of the same height were connected to the implants and the implant stability was measured four times in different directions with Anycheck. The measured mean values were statistically analyzed. RESULTS. The correlation coefficient between the mean implant stability quotient (ISQ) and IST value was 0.981 (P<.01) and the correlation coefficient between the meant periotest value (PTV) and IST value was -0.931 (P<.01). There were no statistically significant differences among the IST values with different healing abutment diameters. CONCLUSION. There was a strong correlation between the Periotest M and Anycheck values and between the ISQ and IST. The diameter of the healing abutment had no effect on the Anycheck values.

Effects of surface treatment on the osseointegration potential of orthodontic mini-implant (분사처리 후 산부식 표면처리된 교정용 미니 임플랜트의 골유착능에 관한 연구)

  • Jeon, Mi-Sun;Kang, Yoon-Goo;Mo, Sung-Seo;Lee, Keun-Bye;Kook, Yoon-Ah;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.328-336
    • /
    • 2008
  • Objective: The purpose of this study was to compare the torque resistance to removal of sandblasted large grit and acid etched (SLA) surface treated orthodontic mini-implants and smooth surface orthodontic mini-implants as well as performing histologic observations. Methods: Two groups of custom screw shaped orthodontic mini-implants (C-implant, 1.8 mm outer diameter $\times$ 9.5 mm length, Cimplant, Seoul, Korea) were designated. 22 SLA treated C-implants (SLA group) and 22 machined surface C-implants (machined group) were placed in the tibia metaphysis of 11 adult New Zealand white rabbits. Following a 6-week healing period, the rabbits were sacrificed. Subsequently, the C-implants were removed under reverse torque rotation with a digital torque measuring device and independent t-test was performed. Selected tissues were prepared for histologic observation. Results: The SLA group presented a higher mean removal torque value (6.286 Ncm) than the machined group (4.491 Ncm) which was statistically significant (p < 0.005). Histologic observation revealed a trend of more new bone formation in contact with the screw surface in the SLA group than the smooth group. Conclusions: The results of this study suggested that SLA surface treatment can enhance the osseintegration potential for C-orthodontic mini-implants.

Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading (새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력)

  • Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.151-155
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate screw removal torque of the two-piece zirconia abutment with the novel titanium component compared to the conventional one-piece titanium abutment in the internal connection implant before and after dynamic cyclic loading. Materials and methods: Two types of the abutment assemblies with internal connection were prepared and divided into the groups; titanium abutment-titanium abutment screw assemblies as control, and zirconia abutment-titanium socket-titanium abutment screw assemblies as experimental group. A total of 12 abutments and implants were used of six assemblies each group. Each assembly was tightened to 30 Ncm. A cyclic load of 300 N at an angle of 30 degrees in reference to the loading axis was applied until one million cycles or failure. The removal torque values (RTVs) of the abutment screws were measured with a digital torque gauge before and after cyclic loading. The RTVs of the pre load and post load were analyzed with t-test, and P-values < .05 were considered statistically significant. Results: The assemblies of both groups survived all after the dynamic cyclic loading test without screw loosening. The statistically significant differences were found between the mean RTVs before and after the cyclic loading in both groups (P < .05). The RTV differences for the control and the experimental group were $-7.25{\pm}1.50Ncm$ and $-7.33{\pm}0.93Ncm$, respectively. Statistical analysis revealed that the RTV differences in both groups were not significantly different from each other (P > .05). Conclusion: Within the limitation of this study, the two-piece zirconia abutment with the titanium component did not show a significant RTV difference of the abutment screw compared to the titanium abutment after dynamic cyclic loading.

RELATIONSHIP BETWEEN MANDIBULAR MOVEMENTS AT INCISAL AREA AND CONDYLAR MOVEMENTS (전치부 하악운동양태와 과두운동 간의 관계)

  • Kang, Seok-Ku;Han, Kyung-Soo;Jin, Tai-Ho;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.15-29
    • /
    • 1997
  • The author performed this study to investige the relationship between condylar movements recorded with Pantronic and mandibular movements at incisal area recorded with BioEGN. For this study 24 patients with Temporomandibular disorders(TMDs) and 30 dental students without any masticatory symptoms were selected as patients group and control group, respectively. The items recorded with Pantronic(Denar Corp., USA) were immediate side-shift, orbiting path, protrusive path, and PRI. BioEGN(Bioelectric-gnathography, Bioresearch Inc., USA) were sued to measure the amount of mandibular torque movement in frontal and horizontal plane and also the distance of mandibular translation at incisal area. Amount of mandibular rotational torque movement was analyzed by angle and difference between both condyles in frontal and horizontal plane. The collected data were processed with SAS program and conclusion were as follows : 1. Mean value of items recorded with Pantronic were not significantly differed between patients group and control group except the item of pantographic reproducibility index(PRI). The value of PRI was 39.5 in patients group, and 29.5 in control group. 2. The amount of mandibular torque movement was not differed tin early protrusive and early left excursion between patients group and control group, but in early right excursion, patients group showed more value than control group did. 3. The distance on sagittal plane in early eccentric movements were longer in patients group than those in control group, but the distance of maximal eccentric movements were not significantly differed between patients group and control group. 4. Items which showed significant correlation with PRI were progressive side-shift, and horizontal torque movement in early protrusion and right excursion. 5. The angle of protrusive path of affected side was greater than of non-affected side in unilaterally affected patients, but the protrusive angle of preferred chewing side was not differed from that of contralateral side in control group. 6. The amount of torque movement in early protrusion and right excursion were greater in patients with coincidence of affected side and preferred chewing side than in patients without coincidence.

  • PDF

Correlation of Human Carpal Motion and Electromyogram (인체 수관절 운동과 근전도의 상관관계)

  • Chun, Han-Yong;Kim, Jin-Oh;Park, Kwang-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1393-1401
    • /
    • 2010
  • In this experimental study, we have examined the correlation between a human carpal motion and a surface electromyogram. The carpal motion patterns have been identified and the main muscles involved in the carpal motion have been determined by investigating the anatomical structure of a carpal. The torque acting against the carpal motion has been applied by using a device for carpal rehabilitation training, and the surface electromyogram signal corresponding to the torque at the main muscles has been measured. The root-mean-square (RMS) magnitude of the surface electromyogram signal has been calculated and used to analyze the correlation between the surface electromyogram signal and carpal motion. The experimental results have proved that for carpal torque values below $0.1\;N{\cdot}m$, the RMS magnitude of the surface electromyogram signal is linearly proportional to the carpal torque magnitude and that the carpal torque magnitude is linearly proportional to the cross-sectional area of the carpal muscles. Further, the analysis of the contribution of each muscle to the carpal motion has shown that the contribution of the most dominant muscle is consistently 60%. These three results can be applied to develop more sophisticated devices or robots for carpal rehabilitation training.

A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables

  • Lee, Su-Young;Piao, Chunmei;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Kim, Tae-Hyung;Kim, Myung-Joo;Kwon, Ho-Beom;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.4
    • /
    • pp.148-153
    • /
    • 2010
  • PURPOSE. The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS. Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS. The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ${\geq}$ .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION. Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling.

Stress Analysis of Epitrochoidal Gerotor for Hydraulic Motor (유압 모터용 에피트로코이드 제로터의 응력해석)

  • Kim, Du-In;Choe, Dong-Hun;An, Hyo-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.963-971
    • /
    • 2000
  • Gerotor is a planar mechanism consisting of a rotor and lobes which form a closed space, namely a chamber. As active contact points between a rotor and lobes are subjected to very high contact stresses, wear in one or both of the rotor and lobe cannot be avoided. Therefore, in the design of Gerotor used in hydraulic motors a compromise between high torque output and contact stress is of great importance and a thorough analysis of design parameters should be conducted to achieve this compromise. In this study, a contact point is modelled as a linear spring in consideration of equivalent curvature to analyze the contact stress. As the contact stress calculation in this problem is a statically indeterminate type, a numerical iterative scheme has been adopted to obtain the solution. To fully understand the influence of design parameters on the contact stress, the relationship between pressure force, equivalent curvature, contact force and contact stress are analyzed. It is shown that the equivalent curvature of the contact point is a dominant factor that affects the maximum contact stress.

Biomechanical Analysis of Injury Factors in the Run UP and Jump Phases of the Jetѐ (발레 Jetė 동작의 도움닫기와 점프구간에서 상해 발생 요인에 대한 생체역학적 분석)

  • Lee, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.3
    • /
    • pp.295-304
    • /
    • 2012
  • This study, through biomechanical analysis, conducts a risk assessment of injury occurrence in ballet dancers while they perform running and jumping movements. The participants were nine female collegiate students majoring in ballet(age: $20.89{\pm}1.17years$; height: $160.89{\pm}7.01cm$; mass: $48.89{\pm}3.26$). Descriptive data were expressed as $mean{\pm}standard$ deviation(SD) for all variables. An independent t-test was conducted to determine how the following variables differed: duration time, position of the center of gravity, angle of the hip, torque of the hip, and muscle activity. All comparisons were made at the p<0.05 significance level. The results show that the jump time was two times longer than the run time in the duration time. The jump length was also longer than the run. The angle of the hip and the torque at the hip were higher in the right. The vastus medialis muscle was most frequently used. These findings demonstrate that participants' jumps may require more biomechanical variables for performance of better and more correct $jet{\acute{e}}$.