The reliability of Anycheck device related to healing abutment diameter |
Lee, Dong-Hoon
(Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medicine, Korea University)
Shin, Yo-Han (Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medicine, Korea University) Park, Jin-Hong (Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medicine, Korea University) Shim, Ji-Suk (Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medicine, Korea University) Shin, Sang-Wan (Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medicine, Korea University) Lee, Jeong-Yol (Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medicine, Korea University) |
1 | Salvi GE, Lang NP. Diagnostic parameters for monitoring peri-implant conditions. Int J Oral Maxillofac Implants 2004;19:116-27. |
2 | Sekiguhi J. An attempt to measure viscoelasticity of human facial skin by impact hammer method. J Kanagawa Odontol Soc 1992;26:387-411. |
3 | Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res 2004;15:520-8. DOI |
4 | Friberg B, Sennerby L, Linden B, Grondahl K, Lekholm U. Stability measurements of one-stage Branemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg 1999;28:266-72. DOI |
5 | Hayashi M, Kobayashi C, Ogata H, Yamaoka M, Ogiso B. A no-contact vibration device for measuring implant stability. Clin Oral Implants Res 2010;21:931-6. DOI |
6 | Feng SW, Ho KN, Chan YH, Chang KJ, Lai WY, Huang HM. Damping factor as a diagnostic parameter for assessment of osseointegration during the dental implant healing process: An experimental study in rabbits. Ann Biomed Eng 2016;44:3668-78. DOI |
7 | Pang KM, Lee JW, Lee JY, Lee JB, Kim SM, Kim MJ, Lee JH. Clinical outcomes of magnesium-incorporated oxidised implants: a randomised double-blind clinical trial. Clin Oral Implants Res 2014;25:616-21. DOI |
8 | Alsaadi G, Quirynen M, Michiels K, Jacobs R, van Steenberghe D. A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment. J Clin Periodontol 2007;34:359-66. DOI |
9 | Winkler S, Morris HF, Spray JR. Stability of implants and natural teeth as determined by the Periotest over 60 months of function. J Oral Implantol 2001;27:198-203. DOI |
10 | Truhlar RS, Morris HF, Ochi S. Stability of the bone-implant complex. Results of longitudinal testing to 60 months with the Periotest device on endosseous dental implants. Ann Periodontol 2000;5:42-55. DOI |
11 | Oh JS, Kim SG, Lim SC, Ong JL. A comparative study of two noninvasive techniques to evaluate implant stability: Periotest and Osstell Mentor. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;107:513-8. DOI |
12 | Cehreli MC, Karasoy D, Akca K, Eckert SE. Meta-analysis of methods used to assess implant stability. Int J Oral Maxillofac Implants 2009;24:1015-32. |
13 | Devlin H, Horner K, Ledgerton D. A comparison of maxillary and mandibular bone mineral densities. J Prosthet Dent 1998;79:323-7. DOI |
14 | Andreotti AM, Goiato MC, Nobrega AS, Freitas da Silva EV, Filho HG, Pellizzer EP, Micheline Dos Santos D. Relationship between implant stability measurements obtained by two different devices: A systematic review. J Periodontol 2017;88:281-8. DOI |
15 | Lachmann S, Laval JY, Jager B, Axmann D, Gomez-Roman G, Groten M, Weber H. Resonance frequency analysis and damping capacity assessment. Part 2: peri-implant bone loss follow-up. An in vitro study with the Periotest and Osstell instruments. Clin Oral Implants Res 2006;17:80-4. DOI |
16 | Herrero-Climent M, Santos-Garcia R, Jaramillo-Santos R, Romero-Ruiz MM, Fernandez-Palacin A, Lazaro-Calvo P, Bullon P, Rios-Santos JV. Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study. Med Oral Patol Oral Cir Bucal 2013;18:e877-82. |
17 | Zix J, Hug S, Kessler-Liechti G, Mericske-Stern R. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial. Int J Oral Maxillofac Implants 2008;23:525-30. |
18 | Walker L, Morris HF, Ochi S. Periotest values of dental implants in the first 2 years after second-stage surgery: DICRG interim report no. 8. Dental Implant Clinical Research Group. Implant Dent 1997;6:207-12. DOI |
19 | Truhlar RS, Morris HF, Ochi S. Stability of the bone-implant complex. Results of longitudinal testing to 60 months with the Periotest device on endosseous dental implants. Ann Periodontol 2000;5:42-55. DOI |
20 | Meredith N, Friberg B, Sennerby L, Aparicio C. Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. Int J Prosthodont 1998;11:269-75. |
21 | Atsumi M, Park SH, Wang HL. Methods used to assess implant stability: current status. Int J Oral Maxillofac Implants 2007;22:743-54. |
22 | Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501. |
23 | Sennerby L, Roos J. Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. Int J Prosthodont 1998;11:408-20. |
24 | Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000 2008;47:51-66. DOI |
25 | Ostman PO, Hellman M, Wendelhag I, Sennerby L. Resonance frequency analysis measurements of implants at placement surgery. Int J Prosthodont 2006;19:77-83; discussion 84. |
26 | Hurzeler MB, Quinones CR, Schupbach P, Vlassis JM, Strub JR, Caffesse RG. Influence of the suprastructure on the periimplant tissues in beagle dogs. Clin Oral Implants Res 1995;6:139-48. DOI |
27 | van Steenberghe D, Tricio J, Naert I, Nys M. Damping characteristics of bone-to-implant interfaces. A clinical study with the Periotest device. Clin Oral Implants Res 1995;6:31-9. DOI |
28 | Morris HE, Ochi S, Crum P, Orenstein I, Plezia R. Bone density: its influence on implant stability after uncovering. J Oral Implantol 2003;29:263-9. DOI |
29 | Teerlinck J, Quirynen M, Darius P, van Steenberghe D. Periotest: an objective clinical diagnosis of bone apposition toward implants. Int J Oral Maxillofac Implants 1991;6:55-61. |
![]() |