• Title/Summary/Keyword: maximum $F_0$

Search Result 1,046, Processing Time 0.034 seconds

A Study on the Recovery of Aluminum from Aluminum dross (알루미늄 드로스로부터 알루미늄의 회수에 관한 연구)

  • 김홍진;김용현;이병우;이광학
    • Resources Recycling
    • /
    • v.6 no.1
    • /
    • pp.5-10
    • /
    • 1997
  • The aluminum was recovered from the middle size (Q1.0-12.0 mm) aluminum drosses using NaCl and KC1 mixuture as a basic salt flux. The maximum aluminum recovery was about 76.9% when 40% basic salt flux was added to aluminum dross at 850$^{\circ}$C for two hours. Also, aluminum remvery increased with increasing fluoride (1%-5%) addition to basic salt flux. But, there was no considerable effect due ta the increasing of viscosity when the fluorides were added over 5%, respectively. E s p d y , the most aluminum recovery was about 83.5% when 5% cryolite was added to 40% basic salt flux.

  • PDF

Thermoluminescent Characteristics of Newly Developed LiF:Mg,Cu,Na,Si TL Detectors

  • Lee J. I.;Kim J. L.;Chang S. Y.
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.47-52
    • /
    • 2004
  • Recently, a new sintered pellet-type LiF:Mg,Cu,Na,Si TL detector which has a high sensitivity and good reusability, named KLT-300(KAERI LiF:Mg,Cu,Na,Si TL detector), was developed by the variation of the dopants concentrations and the parameters of the preparation procedure at KAERI (Korea Atomic Energy Research Institute). In this study, the thermoluminescent characteristics of the newly developed TL detectors were investigated. The sensitivity of the TL detector was compared with that of the TLD-100 by light integration. The dose linearity of the detector was tested from $10^{-6}$ Gy up to 30 Gy. The dose response was very linear up to 10 Gy and a sublinear response was observed at higher doses. The energy response of the detector was studied for photon energies from 20 keV to 662 keV. The result shows that a maximum response of 1.004 at 53 keV and a minimum response of 0.825 at 20 keV were observed. The reproducibility study for the TL detector was also carried out. The coefficients of variation for each detector separately did not exceed 0.016, and for all the 10 detectors collectively was 0.0054. Lower limit of detection for the detector was investigated at 70 nGy by the Harshaw 4500 TLD Reader and the residual signal of the TL detector was found to be $0.57\%$.

The Effects of Antimony and Tin Addition on the wear resistance properties of ductile cast iron (구상흑연주철의 내마모성에 미치는 Sb 및 Sn 의 영향에 관한 연구)

  • Kwon, Young-Hoon;Kim, Chang-Gyu;Kim, Buk-Suk;Kim, Sung-Han;Cheon, Byung-Wook;Choi, Chang-Ock
    • Journal of Korea Foundry Society
    • /
    • v.11 no.6
    • /
    • pp.463-474
    • /
    • 1991
  • The effect of $0.01{\sim}0.10%$ Sb and Sn on the wear resistance of ductile cast iron was investigated. The hardness was increased with Sb to 0.10%, but the elongation and the impact value were decreased. The tensile strength was increased with up to 0.05% Sb, however decreased with $0.05{\sim}0.10%$ Sb. The hardness and the tensile strength were increased and the elongation was decreased with up to 0.10% Sn. The nodularity of graphite was decreased with above 0.08% Sb however Sn had no effect on that. When the maximum compressive stress was low ($42kg.f/mm^2$), the weigth loss was decreased with increased hardness and when that was high ($54kg.f/mm^2$ and $65kg.f/mm^2$), the weight loss did not depend upon the hardness. The pearlite stabilization with Sb and Sn increased with the wear resistance of ductile cast iron.

  • PDF

Electrical Properties of OLEDs depending on Thickness variation of Electron Injection Layer (전자 주입층의 두께 변화에 따른 OLEDs의 전기적 특성)

  • Cha, Ki-Ho;Lee, Young-Hwan;Lee, Jong-Yong;Chung, Dong-Hoe;Shin, Jong-Yeol;Kim, Tae-Wan;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.69-70
    • /
    • 2006
  • We studied increasement of efficiency of Organic Light-emitting Diodes depending on thickness variation of LiF, Material of Electron Injection Layer in structure of ITO/Hole Injection Layer (PTFE)/Hole Transportion Later (TPD)/Emitting Layer (Alq3)/Electron Injection Layer (LiF)/Al. TPD and $Alq_3$ is deposited as rate of 1.3~1.5 [${\AA}/s$] in high vacuum ($5{\times}10^{-6}$ [torr]). In result of these studies, we can know maximum efficiency in 0.7 [nm], thickness of LiF. And samples with electron injection material are increased about 5-fold in maximum efficiency in compare with sample without electron injection material.

  • PDF

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

Modification of CPW Pad Design for High fmax InGaAs/InAlAs Metamorphic High Electron Mobility Transistors (높은 $f_{max}$ 를 갖는 InGaAs/InAlAs MHEMT 의 Pad 설계)

  • Choi, Seok-Gyu;Lee, Bok-Hyung;Lee, Mun-Kyo;Kim, Sam-Dong;Rhee, Jin-Koo
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.599-602
    • /
    • 2005
  • In this paper, we have performed a study that modifies the CPW Pad configurations to improve an $f_{max}$ characteristic of metamorphic HEMT. To analyze the CPW Pad structures of MHEMT, we use the ADS momentum simulator developed by $Agilent^{TM}$. Comparing the employed structure (G/W = 40/100 m), the optimized structure (G/W = 20/25 m) of CPW MHEMT shows the increased $S_{21}$ by 2.5 dB, which is one of the dominant parameters influencing the $f_{max}$ of MHEMT. To compare the performances of optimized MHEMT with the employed MHEMT, DC and RF characteristics of the fabricated MHEMT were measured. In the case of optimized CPW MHEMT, the measured saturated drain current density and transconductance $(g_m)$ were 693 mA/mm and 647 mS/mm, respectively. RF measurements were performed in a frequency range of $0.1{\sim}110$ GHz. A high $S_{21}$ gain of 5.5 dB is shown at a millimeter-wave frequency of 110 GHz. Two kinds of RF gains, $h_{21}$ and maximum available gain (MAG), versus the frequency, and a cut-off frequency ($f_t$) of ${\sim}154$ GHz and a maximum frequency of oscillation ($f_{max}$) of ${\sim}358$ GHz are obtained, respectively, from the extrapolation of the RF gains for a device biased at a peak transconductance. An optimized CPW MHEMT structure is one of the first reports among fabricated 0.1 m gate length MHEMTs.

  • PDF

Lock-on Characteristics of Wake Behind a Rotationally Oscillating Circular Cylinder (주기적으로 회전진동하는 원주 후류의 공진특성에 관한 연구)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.8 s.239
    • /
    • pp.895-902
    • /
    • 2005
  • Lock-on characteristics of flow around a circular cylinder oscillating rotationally with a relatively high forcing frequency have been investigated experimentally. Dominant governing parameters are Reynolds number (Re), angular amplitude of oscillation (${\theta}_A$), and frequency ratio $F_R=f_f/f_n,\;where\;f_f$ is a forcing frequency and $f_n$ is a natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14{\times}10^3,\;{\pi}/90{\leq}{\theta_A}{\leq}{\pi}/3,\;and\;F_R=1.0$. The effect of this active flow control technique on the lock-on flow characteristics of the cylinder wake was evaluated with wake velocity measurements and spectral analysis of hot-wire signals. The rotational oscillation modifies the flow structure of near wake significantly. The lock-on phenomenon always occurs at $F_R=1.0$, regardless of the angular amplitude ${\theta}_A$. In addition, when the angular amplitude is less than a certain value, the lock-on characteristics appear only at $F_R=1.0$,. The range of lock-on phenomena expands and vortex formation length is decreased, as the angular amplitude increases. The rotational oscillation create a small-scale vortex structure in the region just near the cylinder surface. At ${\theta}_A=60^{\circ}$, the drag coefficient was reduced about $43.7\%$ at maximum.

Spectral Irradiance and Underwater Transmission Characteristics of a Combined High-Luminance Light-Emitting Diodes as the Light Source for Fishing Lamps (복수 조합에 의한 고휘도 발광 다이오드의 분광분포와 수중투과특성)

  • Choi, Sok-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.6
    • /
    • pp.703-710
    • /
    • 2009
  • The spectral irradiance and underwater transmission characteristics of a combined high-luminance light-emitting diode (LED) lights have been studied to evaluate suitable light sources for fishing lamps of the next generation. The wavelengths at which the irradiance was maximum were changed from 473, 501, 525, and 465 nm for blue, peacock blue, green, and white LED light to 475, 504 and 528 nm for [$F_{WB}$], [$F_{PB}$] and [$F_{GB}$] combined LED lights, respectively. If the irradiance characteristics at 400-700 nm wavelengths are set as 100%, the irradiance rates at 450-499 nm and 500-549 nm were decreased from 82.4% and 56% for blue, peacock blue LED light to 60.0%, 38.5% for [$F_{WB}$], [$F_{WP}$] combined LED lights. The underwater transmission characteristics of the combined LED lights were superior in the order [$F_{WB}$], [$F_{BP}$], [$F_{GB}$] in optical water type I; [$F_{WB}$], [$F_{PB}$], [$F_{GP}$] in optical water type II-III; and [$F_{GP}$], [$F_{WP}$], [$F_{PB}$] in optical water type 1. Setting the 10m depth underwater transmission characteristics of the combined LED lights in optical water type I at 100%, the transmission of water types II, III and 1 drops to 29.5%, 8.0% and 2.2%. Based on the distribution of spectral irradiance and underwater transmission characteristics calculated in optical water types II-III, where was the jigging ground for fishing lamps, the [$F_{WB}]$ and [$F_{GP}$] combined LED lights can be used as a suitable light sources for fishing lamps of the next generation.

Potential Utility of FDG PET-CT as a Non-invasive Tool for Monitoring Local Immune Responses

  • Lee, Seungho;Choi, Seohee;Kim, Sang Yong;Yun, Mi Jin;Kim, Hyoung-Il
    • Journal of Gastric Cancer
    • /
    • v.17 no.4
    • /
    • pp.384-393
    • /
    • 2017
  • Purpose: The tumor microenvironment is known to be associated with the metabolic activity of cancer cells and local immune reactions. We hypothesized that glucose metabolism measured by 2-deoxy-2-($^{18}F$)fluoro-D-glucose ($^{18}F-FDG$) positron emission tomography (PET)-computed tomography (CT) ($^{18}F-FDG$ PET-CT) would be associated with local immune responses evaluated according to the presence of tumor infiltrating lymphocytes (TILs). Materials and Methods: We retrospectively reviewed 56 patients who underwent $^{18}F-FDG$ PET-CT prior to gastrectomy. In resected tumor specimens, TIL subsets, including cluster of differentiation (CD) 3, CD4, CD8, Forkhead box P3 (Foxp3), and granzyme B, were subjected to immunohistochemical analysis. The prognostic nutritional index (PNI) was calculated as: ($10{\times}serum$ albumin value)+($0.005{\times}peripheral$ lymphocyte counts). Additionally, the maximum standard uptake value ($SUV_{max}$) was calculated to evaluate the metabolic activity of cancer cells. Results: The $SUV_{max}$ was positively correlated with larger tumor size (R=0.293; P=0.029) and negatively correlated with PNI (R=-0.407; P=0.002). A higher $SUV_{max}$ showed a marginal association with higher CD3 (+) T lymphocyte counts (R=0.227; P=0.092) and a significant association with higher Foxp3 (+) T lymphocyte counts (R=0.431; P=0.009). No other clinicopathological characteristics were associated with $SUV_{max}$ or TILs. Survival analysis, however, indicated that neither $SUV_{max}$ nor Foxp3 held prognostic significance. Conclusions: FDG uptake on PET-CT could be associated with TILs, especially regulatory T cells, in gastric cancer. This finding may suggest that PET-CT could be of use as a non-invasive tool for monitoring the tumor microenvironment in patients with gastric cancer.

Physicochyemical Properties of $ZrF_4-Based$ Fluoride Glasses Containing Rare-Earth Ions

  • Ishioka, Noriyuki;Ogawa, Kouji;Arakawa, Tsuyoshi
    • The Korean Journal of Ceramics
    • /
    • v.5 no.4
    • /
    • pp.375-378
    • /
    • 1999
  • In tho XRD study of $56ZrF_4 \cdot34BaF_2 \cdot4AIF_3 \cdot(6-x)LaF_3 \cdotxLnF_3$ glassdLn=Ce, Nd, Gd, Th), halo pattern charactarktic fo an amorphous sample appeared. When the halo peak angle ($\theta_p$) was converted into a wavenumber with $Qp=4\pi sinG\pi/\lambda(\lambda$ is the wavolongth of the radialion used), it was found that the Qp values varied almost liuearly with the concentration 01 $LnF_3$. The emissiou spect1.a of $Ce^{3-}$-containing fluoride glasses nnder 273 nm excitation had a peak maximum at ea. 300 nm $(Ce^{3+}$ 5d-4f- transition). The maximal intensity of the fluorescence was observed when the $CeF_3$, content was extremely low (ca. 1 mol%j. DTA measurement revealed tbat these fluoride glasses had two crystallization temperatures. In $56ZrF_4. 34BaF_2. 4NF_3. (6-x)LaF_3 .xNdF_3$ glasses, the actmation energies of crystallization obtained from a Kssinger plot were 1.7 and 5.0 eV for the glass with x=2, and 1.9 and 5.6 eV for the glass with x=4.

  • PDF