• Title/Summary/Keyword: marginal fit

Search Result 165, Processing Time 0.028 seconds

A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability

  • Hong, Seoung-Jin;Kwon, Kung-Rock;Jang, Eun-Young;Moon, Ji-Hoi
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.233-238
    • /
    • 2020
  • PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutment fabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crown-abutment interface were collected by washing with 500 µL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cement-retained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.

Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems

  • Park, Jong-Kyoung;Lee, Wan-Sun;Kim, Hae-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.122-128
    • /
    • 2015
  • PURPOSE. To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (${\alpha}$=.05), respectively. RESULTS. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION. Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (< $120{\mu}m$). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.

A STUDY OF PRECISE FIT OF THE CAM ZIRCONIA ALL-CERAMIC FRAMEWORK (CAM Zirconia 완전도재 구조물의 정밀 적합도에 관한 연구)

  • Jeon Mi-Hyeon;Jeon Young-Chan;Jeong Chang-Mo;Lim Jang-Seop;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.611-621
    • /
    • 2005
  • State of problem: Zirconia all-ceramic restoration fabricated with CAM system is on an increasing trend in dentistry. However, evaluation of the marginal and internal fits of zirconia bridge seldomly have been reported. Purpose: This study was to evaluate the at of margin and internal surface in posterior 3-unit zirconia bridge framework fabricated with CAM system(DeguDent, Germany). Material and Method: Preparations of secondary premolar and secondary molar on artificial resin model were performed for fabrication of 3-unit posterior bridge framework. Fits of 5 zirconia bridge framework were compared with 5 precious ceramo-metal alloy framework(V-GnathosPlus, Metalor, Switzerland), and prepared margins were designed to chamfer and shoulder finishing line. Each framework was cemented to epoxy resin model with reinforced glass ionomer(FujiCEM, GC Co., Japan), embedded in acrylic resin and sectioned in two planes, mesio-distal and buccolingual. Samples were divided into six pieces by sectioning and had two pieces of each surface(i.e mesial, distal, buccal and lingual surface) per abutment, so there were eight measuring points in each abutment. External gap was measured at the margin and internal gaps were measured at the margin, axial and occlusal surface. Gaps were observed under the measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of $\times100$. T-test were used to determine the statistic significance of the different gaps between zirconia and metal framework. Results and Conclusion: 1. External and internal marginal gaps of zirconia and metal framework were in clinically acceptable range. External marginal gaps were not different significantly between zirconia$(81.9{\mu}m)$ and metal $(81.3{\mu}m)$ framework and internal marginal gaps of zirconia $(44.6{\mu}m)$ were smaller than those of metal framework $(58.6{\mu}m)$. 2. Internal axial gaps of zirconia framework$(96.7{\mu}m)$ were larger than those of metal frame-work$(78.1{\mu}m)$ significantly and adversely, internal occlusal gaps of zirconia frame-work$(89.4{\mu}m)$ were smaller than those of metal framework $(104.9{\mu}m)$ significantly. 3. There were no significant differences in external and internal marginal gaps between chamfer and shoulder finish line when zirconia frameworks were fabricated.

Impact of surface roughness of gypsum materials on adaptation of zirconia cores

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Sa-Hak
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.199-206
    • /
    • 2015
  • PURPOSE. The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS. The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (${\alpha}$=.05). RESULTS. The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION. The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.

Mandibular Implant-Supported Telescopic Overdenture using Gold Electroforming System : A Case Report (Gold Electroforming System을 이용한 하악 임플란트 지지 텔레스코프 피개의치)

  • Choi, Jee-Ha;Kim, Seung-Kyun;Yu, Byoung-Il;Ahn, Seung-Geun;Park, Ju-Mi;Song, Kwang-Yeob;Park, Charn-Woon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.193-201
    • /
    • 2008
  • In edentulous mandible, implant supported overdenture was considered as a first treatment option. In case of a implant supported telescopic overdenture, sufficient inter-arch space needs for arrangement of artificial teeth and attachment. Passive fit of the implant prosthesis is important factor for preventing mechanical failure. Gold Electroforming System is particularly useful to achieve a passive fit of telescopic attachment and results in precision marginal fit and the small thickness of the coping provides optimal space for narrow inter-arch space. This article presents that application of Gold Electroforming System can provide excellent esthetics and function on four-implant supported telescopic overdenture.

Multivariate design estimations under copulas constructions. Stage-1: Parametrical density constructions for defining flood marginals for the Kelantan River basin, Malaysia

  • Latif, Shahid;Mustafa, Firuza
    • Ocean Systems Engineering
    • /
    • v.9 no.3
    • /
    • pp.287-328
    • /
    • 2019
  • Comprehensive understanding of the flood risk assessments via frequency analysis often demands multivariate designs under the different notations of return periods. Flood is a tri-variate random consequence, which often pointing the unreliability of univariate return period and demands for the joint dependency construction by accounting its multiple intercorrelated flood vectors i.e., flood peak, volume & durations. Selecting the most parsimonious probability functions for demonstrating univariate flood marginals distributions is often a mandatory pre-processing desire before the establishment of joint dependency. Especially under copulas methodology, which often allows the practitioner to model univariate marginals separately from their joint constructions. Parametric density approximations often hypothesized that the random samples must follow some specific or predefine probability density functions, which usually defines different estimates especially in the tail of distributions. Concentrations of the upper tail often seem interesting during flood modelling also, no evidence exhibited in favours of any fixed distributions, which often characterized through the trial and error procedure based on goodness-of-fit measures. On another side, model performance evaluations and selections of best-fitted distributions often demand precise investigations via comparing the relative sample reproducing capabilities otherwise, inconsistencies might reveal uncertainty. Also, the strength & weakness of different fitness statistics usually vary and having different extent during demonstrating gaps and dispensary among fitted distributions. In this literature, selections efforts of marginal distributions of flood variables are incorporated by employing an interactive set of parametric functions for event-based (or Block annual maxima) samples over the 50-years continuously-distributed streamflow characteristics for the Kelantan River basin at Gulliemard Bridge, Malaysia. Model fitness criteria are examined based on the degree of agreements between cumulative empirical and theoretical probabilities. Both the analytical as well as graphically visual inspections are undertaken to strengthen much decisive evidence in favour of best-fitted probability density.

Comparison of internal and marginal fit of crown according to milling order in a single machinable wax disc (단일 절삭가공용 왁스 디스크 내에서 순차적 절삭가공 순서에 따른 크라운의 내면 및 변연 적합도 비교)

  • Song, Jun-Beom;Lee, Jonghyuk;Ha, Seung-Ryong;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.395-404
    • /
    • 2021
  • Purpose. The purpose of present study was to evaluate the effect of changing structural stability of wax disc on the fit of prosthesis when the milling proceeded in order. Materials and methods. Prepared maxillary left first molar was used to fabricate a Ni-Cr alloy reference model. This was scanned to design crown and then wax pattern was milled, invested and cast to fabricate prosthesis. The wax patterns located in a row centrally within a single wax disc were set into a total of five groups ranging from WM1 group that was first milled to WM5 group that was last milled and the number of each group was set as 10. Silicone replica technique was used to measure the marginal gap, axial internal gap, line angle internal gap, occlusal internal gap. Data was evaluated with one-way ANOVA with significance level set at α = .05 and then Tukey HSD test was conducted for post analysis. Results. Marginal gap measured in each group, it was 40.41 ± 2.15 ㎛ in WM1 group, 40.44 ± 2.23 ㎛ in WM2 group, 39.96 ± 2.25 ㎛ in WM3 group, 39.96 ± 2.48 ㎛ in WM4 group, and 40.57 ± 2.53 ㎛ in WM5 group. No significant difference was found between groups. The significant difference between the groups was also not found in the axial internal gap, line angle internal gap, and occlusal internal gap. Conclusion. Internal and marginal fit of single crown to the sequential order of milling processing in the single machinable wax disc did not seem to be affected by the sequence.

Effects of Property Transformation and Marginal Gap Depending on Heat-Treatment of Metal-Porcelain by Gold Electro-Forming System (전기성형법을 이용한 치과용 금속-도재관의 소성에 따른 물성 변화가 변연 간격에 미치는 영향)

  • Kim, Chi-Young;Chung, In-Sung;Choi, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.352-359
    • /
    • 2010
  • The objective of this paper is to study on the property transformation for materials and to evaluate the precision through marginal gap depending on heat-treatment of metal-porcelain by the gold electro-forming system. Specimens for evaluating property of hardness treat non-treat(HC), once(H1), twice(H2), and three times(H3) by heating, respectively. Specimens for marginal gap classified as each groups of special bonder(FS), special bonder, opaque(FO), special bonder, opaque, body(FB) and non-treatment(FC). As a result for micro-hardness test, the level of hardness on each groups of H1, H2, H3 decreased rather than HC group(p<0.05). In addition, marginal gap was not affected by the number of times being treated by heating. Therefore, the marginal fitness and the precision for mterials were not affected by the heat-treatment on the process to make GES metal-porcelain.

Assessing Tourists' Restaurant Preferences within Tourism Area (관광 지역 음식점에 대한 관광객들의 선호도 평가)

  • Kang, Jong-Heon;Jeong, Hang-Jin
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.18 no.2
    • /
    • pp.165-171
    • /
    • 2008
  • The purpose of this study was to measure tourists' preference for alternative restaurants with different combinations of attribute levels: grown area logo, origin description, traditional food, fusion food, national food, and price. A total of 210 questionnaires were completed. A conjoint experimental method was used to develop hypothetical restaurants, and an ordinal probit model was used to measure the effects of the attribute levels on tourists' preference. The ordinal probit model analysis results for the data indicated an excellent model fit. The effects of the attribute levels on tourists' preferences were statistically significant. As expected, estimates of the marginal willingness to pay were statistically significant Moreover, the tourists were more willing to pay for grown area logo as compared to the other attribute levels. The tourists also considered the grown area logo as a very important attribute. Withe regard to developing and testing conjoint models in the design of choice experiments involving multifactor alternatives, this study may approach a deeper understanding of the conjoint experiment. Greater understanding of the conjoint experiment can improve the managerial diagnoses of the problems as well as the opportunities for different marketing strategies including local branding programs and menu development and marketing communications.

  • PDF

A Study on the Marginal Fit of Dental Prosthesis According to the W/P Ratio of Investment (매몰재의 혼수비가 치관 보철물 변연의 적합성에 미치는 영향에 관한 연구)

  • Hwang, Kyung-Sook
    • Journal of Technologic Dentistry
    • /
    • v.18 no.1
    • /
    • pp.67-72
    • /
    • 1996
  • This test is verifying for influence of W/P ratio of investment upon dental prosthesis Firstly we made 40 MOD die and divide 4 groups, each group take 0.2 different w/p ratio grade such as 0.35, 0.37, 0.39 and 0.41. The method of data analysis applied were by ANOVA, Tukey test and Mann-Whiney and Kruskal Wallis test. The finding of this study were as follows : 1. The 0.37 w/p ratio group showed most accurte margin due to $15.8{\mu}m$ gap between margin and die which keep up with manufacture's instruction and 0.35 w/p ratio group was followed as second accuracy group o 새 $48.3{\mu}m$ gap between margin and die, 0.39 w/p ratio group showed $101{\mu}m$ gap and 0.41 w/p ratio group showed $129.8{\mu}m$ gap. 2. As to the relationship of the margin accuracy between 4 different grade of w/p ratio groups, each group was statistically significant(P<0.01). Also the all groups were statistically significant except between 0.35 and 0.37 groups between 0.39 and 0.41 groups, and between 0.35 and 0.39 groups. 3. A consequence of Mann-Whitney & Kruskal-Wallis test for marginal accuracy between 4 different grade of w/p ratio was statistically significant as same as above ANOVA test result. Also Tukey test for verifying similarity from each group showed same as above.

  • PDF