• Title/Summary/Keyword: margin of safety

Search Result 505, Processing Time 0.026 seconds

Micro-vibration Isolation Performance of X-band Antenna Using Blade Gear (블레이드 기어를 적용한 2축 짐발 구동 안테나의 미소진동 절연성능)

  • Jeon, Su-Hyeon;Kwon, Seong-Cheol;Kim, Tae-Hong;Kim, Yong-Hoon;Oh, Hyun-Ung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.5
    • /
    • pp.313-320
    • /
    • 2015
  • A 2-axis gimbal-type X-band antenna has been widely used to effectively transmit the high resolution image data from the observation satellite to the desired ground station. However, a discontinuous stepper motor activation for rotating the pointing mechanism in azimuth and elevation directions induces undesirable micro-vibration disturbances which can result in the image quality degradation of a high-resolution observation satellite. To enhance the image quality of the observation satellite, attenuating the micro-vibration induced by an activation of the stepper motor for rotational movements of the antenna is important task. In this study, we proposed a low-rotational-stiffness blade gear applied to the output shaft of the stepper motor to obtain the micro-vibration isolation performance. The design of the blade gear was performed through the structure analysis such that this gear is satisfied with the margin of safety rule under the derived torque budget. In addition, the micro-vibration isolation performance of the blade gear was verified through the micro-vibration measurement test using the dedicated micro-vibration measurement device proposed in this study.

Web-shear capacity of prestressed hollow-core slab unit with consideration on the minimum shear reinforcement requirement

  • Lee, Deuck Hang;Park, Min-Kook;Oh, Jae-Yuel;Kim, Kang Su;Im, Ju-Hyeuk;Seo, Soo-Yeon
    • Computers and Concrete
    • /
    • v.14 no.3
    • /
    • pp.211-231
    • /
    • 2014
  • Prestressed hollow-core slabs (HCS) are widely used for modern lightweight precast floor structures because they are cost-efficient by reducing materials, and have excellent flexural strength and stiffness by using prestressing tendons, compared to reinforced concrete (RC) floor system. According to the recently revised ACI318-08, the web-shear capacity of HCS members exceeding 315 mm in depth without the minimum shear reinforcement should be reduced by half. It is, however, difficult to provide shear reinforcement in HCS members produced by the extrusion method due to their unique concrete casting methods, and thus, their shear design is significantly affected by the minimum shear reinforcement provision in ACI318-08. In this study, a large number of shear test data on HCS members has been collected and analyzed to examine their web-shear capacity with consideration on the minimum shear reinforcement requirement in ACI318-08. The analysis results indicates that the minimum shear reinforcement requirement for deep HCS members are too severe, and that the web-shear strength equation in ACI318-08 does not provide good estimation of shear strengths for HCS members. Thus, in this paper, a rational web-shear strength equation for HCS members was derived in a simple manner, which provides a consistent margin of safety on shear strength for the HCS members up to 500 mm deep. More shear test data would be required to apply the proposed shear strength equation for the HCS members over 500 mm in depth though.

A FLOW AND PRESSURE DISTRIBUTION OF APR+ REACTOR UNDER THE 4-PUMP RUNNING CONDITIONS WITH A BALANCED FLOW RATE

  • Euh, D.J.;Kim, K.H.;Youn, Y.J.;Bae, J.H.;Chu, I.C.;Kim, J.T.;Kang, H.S.;Choi, H.S.;Lee, S.T.;Kwon, T.S.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.735-744
    • /
    • 2012
  • In order to quantify the flow distribution characteristics of APR+ reactor, a test was performed on a test facility, ACOP ($\underline{A}$PR+ $\underline{C}$ore Flow & $\underline{P}$ressure Test Facility), having a length scale of 1/5 referring to the prototype plant. The major parameters are core inlet flow and outlet pressure distribution and sectional pressure drops along the major flow path inside reactor vessel. To preserve the flow characteristics of prototype plant, the test facility was designed based on a preservation of major flow path geometry. An Euler number is considered as primary dimensionless parameter, which is conserved with a 1/40.9 of Reynolds number scaling ratio. ACOP simplifies each fuel assembly into a hydraulic simulator having the same axial flow resistance and lateral cross flow characteristics. In order to supply boundary condition to estimate thermal margins of the reactor, the distribution of inlet core flow and core exit pressure were measured in each of 257 fuel assembly simulators. In total, 584 points of static pressure and differential pressures were measured with a limited number of differential pressure transmitters by developing a sequential operation system of valves. In the current study, reactor flow characteristics under the balanced four-cold leg flow conditions at each of the cold legs were quantified, which is a part of the test matrix composing the APR+ flow distribution test program. The final identification of the reactor flow distribution was obtained by ensemble averaging 15 independent test data. The details of the design of the test facility, experiment, and data analysis are included in the current paper.

Determinants of Profitability of Regional Public Hospitals in Korea - Focusing on the COVID-19 Pandemic Period - (지역거점 공공병원의 수익성 결정요인 - COVID-19 유행기간을 중심으로 -)

  • Ji, Seokmin;Ok, Hyunmin
    • Korea Journal of Hospital Management
    • /
    • v.27 no.3
    • /
    • pp.26-38
    • /
    • 2022
  • Purposes: We analyzed the profitability determinants of regional public hospitals during the entire period between 2010 and 2020 and the period before and after COVID-19. We intended to provide fundamental data for developing publicness evaluation index and task of establishing and expanding regional public hospitals. Methodology: The financial and non-financial information of the regional public hospitals were used as the main analysis data; The financial data was established by the Center for Public Healthcare Policy of National Medical Center, and the non-financial data by the Health Insurance Review and Assessment Service. T-test and regression analysis were used. Findings: The results can be summarized in two. First, the main determinants of profitability of the regional public hospitals were appeared to be the total asset turnover rate and the labor cost rate. Second, during the COVID-19 pandemic in the regional public hospitals, the number of sickbeds, the number of isolation rooms, the total asset turnover rate and the labor cost rate appeared to be the factor worsening the profitability. Practical Implication: The results of this study suggests that the management of the regional public hospitals is not aiming for the profit making, but it performs the functions as the community healthcare safety net such as controlling infectious diseases.

Seismic Performance Evaluation of Staggered Wall Structures Using FEMA P695 (FEMA P695를 이용한 격간벽 구조의 내진성능평가)

  • Lee, Joon-Ho;Kang, Hyun-Goo;Lee, Min-Hee;Kim, Jin-Koo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.43-50
    • /
    • 2012
  • The FEMA P695 document proposed a methodology to evaluate the collapse safety of a structure and the validity of the seismic design coefficients. In this study, the seismic performance of six- and twelve-story staggered wall structures with a middle corridor was evaluated based on the FEMA P695 procedure. The analysis results of the prototype structures were compared with those of the structures with an increased coupling beam depth or an increased re-bar ratio of the coupling beams in order to investigate the effect of retrofit. The adjusted collapse margin ratios (ACMR) of the model structures obtained from incremental dynamic analyses turned out to be larger than the specified limit states of an ACMR of 20%, which implies that the analysis model structures have enough strength against design level earthquakes. It was also observed that the increase in the re-bar ratio of the coupling beams between the staggered walls was more effective in increasing the ACMR than an increase in the depth of the coupling beams.

A Construction and Operation Analysis of Group Management Network about Control Devices based on CIM Level 3 (CIM 계층 3에서 제어 기기들의 그룹 관리 네트워크 구축과 운영 해석)

  • 김정호
    • The Journal of Society for e-Business Studies
    • /
    • v.4 no.1
    • /
    • pp.87-101
    • /
    • 1999
  • To operate the automatic devices of manufacturing process more effectively and to solve the needs of the resource sharing, network technology is applied to the control devices located in common manufacturing zone and operated by connecting them. In this paper, functional standard of the network layers are set as physical and data link layer of IEEE 802.2, 802.4, and VMD application layer and ISO-CIM reference model. Then, they are divided as minimized architecture, designed as group objects which perform group management and service objects which organizes and operates the group. For the stability in this network, this paper measures the variation of data packet length and node number and analyzes the variated value of the waiting time for the network operation. For the method of the analysis, non-exhausted service method are selected, and the arrival rates of the each data packet to the nodes that are assumed to form a Poission distribution. Then, queue model is set as M/G/1, and the analysis equation for waiting time is found. For the evalution of the performance, the length of the data packet varies from 10 bytes to 100 bytes in the operation of the group management network, the variation of the wating time is less than 10 msec. Since the waiting time in this case is less than 10 msec, response time is fast enough. Furthermore, to evaluate the real time processing of the group management network, it shows if the number of nodes is less than 40, and the average arrival time is less than 40 packet/sec, it can perform stable operation even taking the overhead such as software delay time, indicated packet service, and transmissin safety margin.

  • PDF

Optimal Methodology of a Composite Leaf Spring with a Multipurpose Small Commercial Vans (다목적 소형 승합차 복합재 판 스프링의 적층 최적화 기법)

  • Ahn, Sang Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.5
    • /
    • pp.243-250
    • /
    • 2018
  • In this paper, design technique using genetic algorithms(GA) for design optimization of composite leaf springs is presented here. After the initial design has been validated by the car plate spring as a finite element model, the genetic algorithm suggests the process of optimizing the number of layers of composite materials and their angles. Through optimization process, the weight reduction process of leaf springs and the number of repetitions are compared to the existing algorithm results. The safety margin is calculated by organizing a finite element model to verify the integrity of the structure by applying an additive sequence optimized through the genetic algorithm to the structure. When GA is applied, layer thickness and layer angle of complex leaf springs have been obtained, which contributes to the achievement of minimum weight with appropriate strength and stiffness. A reduction of 65.6% original weight is reached when a leaf steel spring is replaced with a leaf composite spring under identical requirement of design parameters and optimization.

Intraoperative Radiotherapy for Resectable Pancreatic Cancer Using a Low-Energy X-Ray Source: Postoperative Complications and Early Outcomes

  • Yeona Cho;Jun Won Kim;Hyung Sun Kim;Joon Seong Park;Ik Jae Lee
    • Yonsei Medical Journal
    • /
    • v.63 no.5
    • /
    • pp.405-412
    • /
    • 2022
  • Purpose We evaluated the safety, feasibility, and early treatment outcomes of intraoperative radiotherapy (IORT) using a low-energy X-ray source. Materials and Methods Patients with resectable pancreatic cancer were enrolled in this single-institution, prospective, single-arm, phase II trial. Patients underwent surgery and IORT with 10 Gy prescribed at a 5-mm depth from the tumor bed using a 50 kV X-ray source (Intrabeam, Carl Zeiss). Six cycles of adjuvant gemcitabine-based chemotherapy were administered 8-12 weeks after surgery. Results A total of 41 patients were included. Thirty-one patients (75.6%) underwent wide R0 resection, while 5 (12.2%) underwent R1 resection and 5 (12.2%) underwent narrow R0 resection (retroperitoneal margin <1 mm). Grade 3 postoperative complications were reported in only one patient (4.9%) who needed additional surgery due to ulcer perforation. At a median follow-up of 9 months, four patients showed local-only recurrence, nine had distant metastases, and two showed both local and distant recurrence. The 1-year local control rate was 76.4%. Conclusion Our preliminary report suggests that IORT is well-tolerated and feasible in patients with resectable pancreatic cancer. Further follow-up is needed to confirm the clinical benefits of IORT in terms of local control and overall survival. Trial Registration: Clinical trial registration No. (NCT03273374).

Effects of Zr-hydride distribution of irradiated Zircaloy-2 cladding in RIA-simulating pellet-clad mechanical interaction testing

  • Magnusson, Per;Alvarez-Holston, Anna-Maria;Ammon, Katja;Ledergerber, Guido;Nilsson, Marcus;Schrire, David;Nissen, Klaus;Wright, Jonathan
    • Nuclear Engineering and Technology
    • /
    • v.50 no.2
    • /
    • pp.246-252
    • /
    • 2018
  • A series of simulated reactivity-initiated accident (RIA) tests on irradiated fully recrystallized boiling water reactor Zircaloy-2 cladding has been performed by means of the expansion-due-to-compression (EDC) test method. The EDC method reproduces fuel pellet-clad mechanical interaction (PCMI) conditions for the cladding during RIA transients with respect to temperature and loading rates by out-of-pile mechanical testing. The tested materials had a large variation in burnup and hydrogen content (up to 907 wppm). The results of the EDC tests showed variation in the PCMI resistance of claddings with similar burnup and hydrogen content, making it difficult to clearly identify ductile-to-brittle transition temperatures. The EDC-tested samples of the present and previous work were investigated by light optical and scanning electron microscopy to study the influence of factors such as azimuthal variation of the Zr-hydrides and the presence of hydride rims and radially oriented hydrides. Two main characteristics were identified in samples with low ductility with respect to hydrogen content and test temperature: hydride rims and radial hydrides at the cladding outer surface. Crack propagation and failure modes were also studied, showing two general modes of crack propagation depending on distribution and amount of radially oriented hydrides. It was concluded that the PCMI resistance of irradiated cladding under normal conditions with homogenously distributed circumferential hydrides is high, with good margin to the RIA failure limits. To further improve safety, focus should be on conditions causing nonfavorable hydride distribution, such as hydride reorientation and formation of hydride blisters at the cladding outer surface.

A Study on the Structural Integrity Considering the Installation of a Micro-tube Heat Exchanger (미세튜브 열교환기의 장착을 고려한 구조건전성에 관한 연구)

  • Oh, Se Yun;Kim, Tae Jin;Cho, Jong Rae;Jeong, Ho Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.447-451
    • /
    • 2015
  • The objective of this study is to predict the structural characteristics of a heat exchanger mounted on an aircraft engine using finite element analysis. The plastic fracture and life of the heat exchanger were estimated by a thermo-mechanical analysis. Tensile tests were conducted under high temperature conditions (700, 800, 900, 1000 K) using five specimens to obtain the mechanical properties of the Inconel 625 tubes. To assess the structural characteristics of the heat exchanger, the full and partial models were applied under the operating conditions given by the thermo-mechanical and inertial load. As a result, the case, tubesheet, flange, and mounting components have a reasonable safety margin to the allowable stress assuming a fatigue strength of Inconel 625 of 10000 cycles under 1000 K.