• Title/Summary/Keyword: magnification

Search Result 689, Processing Time 0.03 seconds

Determination of Transverse Magnifications by Distortion Analysis

  • Lee, Sukmock;Kim, Byungoh
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.136-141
    • /
    • 2013
  • A method to determine the transverse magnification (TM) of an imaging system is discussed. This method is different in that TM can be determined accurately by using distortion analysis. We demonstrate the validity of the method via numerical simulation with accompanying experimental data for a thick bi-convex lens.

Variation of water supply for instream flow from reservoirs with various magnifications of paddy irrigation area to watershed area (유역배율에 따른 저수지의 하천유지용수 공급량)

  • Noh, Jae-Kyoung;Lee, Jae-Nam
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.2
    • /
    • pp.331-341
    • /
    • 2011
  • To provide variation of water supply for instream flow from reservoirs with various magnifications of paddy irrigation area to watershed area, 8 reservoirs were selected to draw operation rule curve and to analyze water supplies from reservoirs. Reliability of 90% for supplying irrigation water from reservoir was able to maintain and instream flow water was able to be supplied only in the reservoir with magnification of paddy irrigation area to watershed area above 3. The more magnification of paddy irrigation area to watershed area increased, the more ratio of irrigation water to total water storage decreased, and the more ratio of instream flow water to total water storage increased. From the heightening 113 reservoirs in Korea, annual irrigation water was estimated to 1,146.05 $Mm^3$ in normal operation, 839.57 $Mm^3$ in withdrawal limited operation, and annual instream flow water was estimated to 149.68 $Mm^3$ in normal operation, 283.19 $Mm^3$ in withdrawal limited operation. It was concluded that withdrawal limited operation was followed to have the premise of saving irrigation water, more instream flow water was able to be supplied from reservoirs with high magnification of paddy irrigation area to watershed area.

Video Motion Analysis for Sudden Death Detection During Sleeping (수면 중 돌연사 감지를 위한 비디오 모션 분석 방법)

  • Lee, Seung Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.603-609
    • /
    • 2018
  • Sudden death during sleep often occurs in different age groups. To prevent an unexpected sudden death, sleep monitoring is required. This paper presents a video analysis method to detect sudden death without using any attachable sensors. In the proposed method, a motion magnification technique detects even very subtle motion during sleep. If the magnification cannot detect motion, the proposed method readily decides on abnormal status (possibly sudden death). Experimental results on two kinds of sleep video show that motion magnification-based video analysis could be useful for discriminating sleep (with very subtle motion) from sudden death.

APLICATION OF FRACTAL DIMENSION ESTIMATION ALGORITMS TO EVALUATING HUMAN SKIN STATE

  • Araghy, Ali Parchamy;Sato, Mie;Kasuga, Masao
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.655-658
    • /
    • 2009
  • Fractal dimension has been used for texture analysis as it is highly correlated with human perception of surface roughness and applied to quantifying the structures of wide range of objects in biology and medicine. On the other hand, the evaluation of the human skin state is based solely on the subjective assessment of clinicians; this assessment may vary from moment to moment and from rater to rater. Therefore we attempt to analysis of skin texture image using fractal dimension and discuss its application to evaluating human skin state. It can be helpful for extracting human features and also can be useful for detection of many human skin diseases. This paper presents a method to calculate fractal dimension of skin with use of camera lens magnification. We take multiple pictures frequently from skin with different camera lens magnification as a magnification factor of fractal set, and counting the number of objects (cells) in each picture as a number of self similar pieces of fractal set.

  • PDF

Development of the Precision Positioning Mechanism by Nano Displacement Magnification Device (나노 변위확대기구의 정밀위치결정기구에 관한 연구)

  • Park, Chang-Yong;Kweon, Hyun-Kyu;Zhao, Zhijun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.1
    • /
    • pp.97-103
    • /
    • 2013
  • A new precision positioning mechanism for stage was been developed by Displacement Magnification Device(DMD) in this paper. The DMD was composed of the beam and multilayer piezoelectric actuators. The theoretical and experimental analysis of DMD to enlarge displacement more then 50times were discussed. And the 2-axis stage by using displacement amplification apparatus was added in the new DMD, and it was able to do it through finite element analysis and experiment. As the results, the magnification of DMD can be obtained about $100{mu}m$ displacement to the 10V input voltage($1.5{mu}m$). And the about 50nm of linearity error in the $30{mu}m$ measurement range and 20times of the amplification in displacement can be measured. In addition, the experimental results are confirmed the possibility of millimeter displacement characteristics and correspond to finite element analysis results.

Evaluation of the Usefulness for Air Gap Technique in Digital Magnification Mammography (디지털 유방확대촬영술에서 Air gap technique의 유용성 평가)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • The purpose of this study was investigated optimal exposure condition in digital magnification mammography to decrease radiation dose and increase image quality of the examinee. Auto mode, the average glandular dose is higher than the manual mode. Average glandular dose and image quality were many differences on between grid and air gap technique in auto mode. However, Average glandular dose and signal-to-noise ratio were not different on between grid and air gap technique in manual mode. The signal-to-noise ratio was increased when using the air-gap technique in both mode. According to result, air gap technique may reduce average glandular dose and increase signal-to-noise ratio in digital magnification mammography.

The Optimal Dilution Magnification for Omi-Galsu (오미갈수(五味渴水)의 최적 희석 배율)

  • Han, Eun-Sook
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.19 no.1
    • /
    • pp.62-70
    • /
    • 2009
  • The principal objective of this study was to determine the optimal dilution magnification for Omi-Galsu. The pH of Omi-Galsu generated by varying the temperature of 200cc of water ($4^{\circ}C$ and $80^{\circ}C$) and quantity of Omi-Galsu concentrate (36 g, 45 g, 54 g) was $3.24{\sim}3.33$ and the sugar content of the solution was $6.60{\sim}9.50$, higher than the tea beverages on the market and slightly lower than fruit juice beverages. The Omi-Galsu had a caloric content of $30.65{\sim}38.70\;kcal$, and a protein content of $0.45{\sim}0.65%$. As a result of the sensory evaluations conducted during the summer season, it was determined that the Omi-Galsu produced by mixing 54 g of Omi-Galsu concentrate into 200cc water at $4^{\circ}C$ or $80^{\circ}C$ was the most preferred; however, during the winter months, the "gusto" of the Omi-Galsu produced by mixing 54g concentrate into 200cc water at $4^{\circ}C$ or 45 g of concentrate into 200cc water of $80^{\circ}C$ was preferred most strongly. All in all, the optimal dilution magnification for Omi-Galsu was found to be $4.7{\sim}5.4$.

  • PDF

The Image Changes in the Control Panelipse Radiography by the Control of the Profile Index (Profile Index에 따른 Panelipse Ⅱ 방사선 상층의 변화)

  • Cho Chul-Ho;Sung Jae-Hyun
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.71-78
    • /
    • 1990
  • This research was made to investigate the change of the image layer and of the vertical and horizontal magnification on the Panelipse radiographic image by the control of profile index. Using the Panelipse, a series of 60 exposures were taken with the steel balls placed in the holes of the plastic model plate, and then evaluated by 4 observers. Two points were assigned for a reading of sharp, one for middling sharp, and zero for unsharp. Each ball image then could be given a total reader score of 0 to 8. The author analyzed the image layer as defined by a sharpness score of 6 or more. The results obtained were as follows: As the profile index was increased, the shape of the image layer was not changed, and the width of the image layer was increased, and the position of the layer shifted away from the rotation center. As the profile index was increased, the ranges of vertical and horizontal magnification was increased, especially the ranges of horizontal magnification was greater than that of vertical magnification.

  • PDF

The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

  • Kajan, Zahra Dalili;Davalloo, Reza Tayefeh;Tavangar, Mayam;Valizade, Fatemeh
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.81-87
    • /
    • 2015
  • Purpose: Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Materials and Methods: Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying "Sharpening 2" and "Noise Reduction" processing options to the original images; (2) applying the "Magnification 1:3" option to the image obtained in the first step; (3) enhancing the original images by using the "Diagonal/"option; (4) reviewing the changes brought about by the third step of image processing and then, applying "Magnification 1:3"; (5) applying "Sharpening UM" to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying "Magnification 1:3." Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. Results: The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). Conclusion: This study shows that the application of "Sharpening UM" along with the "Magnification 1:3" processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.