• Title/Summary/Keyword: magnetic sensors

Search Result 563, Processing Time 0.026 seconds

Magnetic Field Sensors using Co-base Amorphous Ribbon (Co계 아몰퍼스리본을 이용한 자계센서)

  • Shin, Kwang-Ho;Park, Kyung-Il;Song, Jae-Yeon;Kim, Young-Hak;SaGong, Geon
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.205-210
    • /
    • 2003
  • To develop the highly sensitive Magneto-Impedance sensor, the amorphous ribbon was micro-processed to meander type sensor pattern, and its external magnetic field dependence of impedance was investigated. The impedance of the pattern had peak value at the magnetic field of 13 Oe and its changing ratio was about 170%. The impedance change per unit magnetic field was about 36% at bias field of 6 Oe, in which the output with high sensitivity and linearity could be obtained. The magnetic field resolution of the sensor module, which consist of the amorphous pattern and driving circuit, was about $10^{-3}$ Oe.

Development of Electronic Compass Using 2-Axis Micro Fluxgate Sensor (2축 마이크로 플럭스게이트 센서 제작을 통한 전자 나침반 개발)

  • 박해석;심동식;나경원;황준식;최상언
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.418-423
    • /
    • 2003
  • This paper describes an electronic compass using micromachined X- and Y-axis micro fluxgate sensors which were perpendicularly aligned each other to measure X- and Y-axis magnetic fields respectively. The fluxgate sensor was composed of rectangular-ring shaped magnetic core and solenoid excitation(49 turns) and pick-up(46 turns) coils. Excitation and pick-up coil patterns which were formed opposite to each other wound the magnetic core alternatively to improve the sensitivity and to excite the magnetic core in an optimal condition with reduced excitation current. The magnetic core has DC effective permeability of ~1000 and coercive field of ~0.1 Oe. The magnetic core is easily saturated due to the low coercive field and closed magnetic path for the excitation field. To decrease the difference of induced second harmonic voltages from X- and Y-axis, excitation condition of 2.8 $V_{P-P}$ and 1.2 MHz square wave was selected. Excellent linear response over the range of -100 $\mu$T to +100 $\mu$T was obtained with 210 V/T sensitivity. The size of each micro fluxgate sensor excluding pad region was about 2.6${\times}$1.7 $mm^2$ and the power consumption was estimated to be 14 mW.W.

A motion capture and mimic system (운동포착 및 재현 시스템)

  • 윤중선;최원수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1344-1347
    • /
    • 1996
  • A general procedure for motion capture and mimic system has been delineated. Utilizing sensors operated in the magnetic fields, complex and optimized movements are easily digitized to analyze and follow. Design concepts of the system are modular, open, and user friendly to ensure the overall system performance. The system consists of motion capture, visualization, plan, mimic and GUI modules. This procedure is currently being implemented on a virtual cyber cube.

  • PDF

Sensor Fusion for Motion Capture System (모션 캡쳐 시스템을 위한 센서 퓨전)

  • Jeong, Il-Kwon;Park, ChanJong;Kim, Hyeong-Kyo;Wohn, KwangYun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.6 no.3
    • /
    • pp.9-15
    • /
    • 2000
  • We Propose a sensor fusion technique for motion capture system. In our system, two kinds of sensors are used for mutual assistance. Four magnetic sensors(markers) are attached on the upper arms and the back of the hands for assisting twelve optical sensors which are attached on the arms of a performer. The optical sensor information is not always complete because the optical markers can be hidden due to obstacles. In this case, magnetic sensor information is used to link discontinuous optical sensor information. We use a system identification techniques for modeling the relation between the sensors' signals. Dynamic systems are constructed from input-output data. We determine the best model from the set of candidate models using the canonical system identification techniques. Our approach is using a simple signal processing technique currently. In the future work, we will propose a new method using other signal processing techniques such as Wiener or Kalman filter.

  • PDF

Development of Respiration Sensors Using Plastic Optical Fiber for Respiratory Monitoring Inside MRI System

  • Yoo, Wook-Jae;Jang, Kyoung-Won;Seo, Jeong-Ki;Heo, Ji-Yeon;Moon, Jin-Soo;Park, Jang-Yeon;Lee, Bong-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.235-239
    • /
    • 2010
  • In this study, we have fabricated two types of non-invasive fiber-optic respiration sensors that can measure respiratory signals during magnetic resonance (MR) image acquisition. One is a nasal-cavity attached sensor that can measure the temperature variation of air-flow using a thermochromic pigment. The other is an abdomen attached sensor that can measure the abdominal circumference change using a sensing part composed of polymethyl-methacrylate (PMMA) tubes, a mirror and a spring. We have measured modulated light guided to detectors in the MRI control room via optical fibers due to the respiratory movements of the patient in the MR room, and the respiratory signals of the fiber-optic respiration sensors are compared with those of the BIOPAC$^{(R)}$ system. We have verified that respiratory signals can be obtained without deteriorating the MR image. It is anticipated that the proposed fiber-optic respiration sensors would be highly suitable for respiratory monitoring during surgical procedures performed inside an MRI system.

Simultaneous Information and Power Transfer Using Magnetic Resonance

  • Lee, Kisong;Cho, Dong-Ho
    • ETRI Journal
    • /
    • v.36 no.5
    • /
    • pp.808-818
    • /
    • 2014
  • To deal with the major challenges of embedded sensor networks, we consider the use of magnetic fields as a means of reliably transferring both information and power to embedded sensors. We focus on a power allocation strategy for an orthogonal frequency-division multiplexing system to maximize the transferred power under the required information capacity and total available power constraints. First, we consider the case of a co-receiver, where information and power can be extracted from the same signal. In this case, we find an optimal power allocation (OPA) and provide the upper bound of achievable transferred power and capacity pairs. However, the exact calculation of the OPA is computationally complex. Thus, we propose a low-complexity power reallocation algorithm. For practical consideration, we consider the case of a separated receiver (where information and power are transferred separately through different resources) and propose two heuristic power allocation algorithms. Through simulations using the Agilent Advanced Design System and Ansoft High Frequency Structure Simulator, we validate the magnetic-inductive channel characteristic. In addition, we show the performances of the proposed algorithms by providing achievable ${\eta}$-C regions.

Research on Oscillation Character of Six-Phase Fractional-Slot Concentrated-Winding Permanent Motor with Different Slot-Pole Match

  • Qiao, Ming-zhong;Zhu, Yong-xin;Liang, Jing-hui;Li, Geng
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1693-1699
    • /
    • 2016
  • The oscillation character of permanent magnetic motor is highly related to its slot-pole match. By calculating air-gap magnet field and radial electromagnetic force of 6-phase fractional-slot concentrated-winding permanent magnetic motor with slot-pole match of 48/44, 48/46, 48/50 and 48/52 under no load and load status, oscillation character of permanent magnetic motor is analyzed. A 20kW prototype with 48 slots and 44 poles is designed. With many sensors attaching to the corresponding parts, oscillatory acceleration is measured, and spectrum of oscillation frequency is recorded as well. The experiment results give proof to the analysis method for permanent magnetic motor oscillation in this paper.

Locating Mechanical Damages Using Magnetic Flux Leakage Inspection in Gas Pipeline System

  • Kim, Jae-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.6
    • /
    • pp.521-526
    • /
    • 2010
  • Gas transmission pipelines are often inspected and monitored using the magnetic flux leakage method. An inspection vehicle known as a "pig" is launched into the pipeline and conveyed along the pipe by the pressure of natural gas. The pig contains a magnetizer, an array of sensors and a microprocessor-based data acquisition system for logging data. This paper describes magnetic flux leakage (MFL) signal processing used for detecting mechanical damages during an in-line inspection. The overall approach employs noise removal and clustering technique. The proposed method is computationally efficient and can easily be implemented. Results are presented and verified by field tests from an application of the signal processing.

Study on the Distortion of Detecting Signals with the Multi-Defects in Magnetic Flux Leakage System (자기누설탐상시스템에서 밀집된 다수의 결함에 의한 탐상 신호 왜곡에 관한 연구)

  • Seo, Kang;Kim, Dug-Gun;Han, Jea-Man;Park, Gwan-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.876-883
    • /
    • 2007
  • The magnetic flux leakage(MFL) type nondestructive testing(NDT) method is widely used to detect corrosion, defects and mechanical deformation of the underground gas pipelines. The object pipeline is magnetically saturated by the magnetic system with permanent magnet and yokes. Hall sensors detect the leakage fields in the region of the defect. The defects are sometimes occurred in group. The accuracy of the detecting signals in this defect cluster become lowered because of the complexity of the defect cluster. In this paper, the effects of the multi -defects are analyzed. The detecting signals are computed by 3-dimensional finite element method and compared with real measurement. The results say that, rather than the size of the defects, the effects of the relative position of the multi-defects are very important on the detecting signals.