• Title/Summary/Keyword: magnetic parameters

Search Result 1,400, Processing Time 0.023 seconds

Characteristic Analysis of Permanent Magnet Linear Generator by using Space Harmonic Method (공간고조파법을 이용한 영구자석 선형 발전기의 특성 해석)

  • Seo, Seong-Won;Choi, Jang-Young;Kim, Il-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.688-695
    • /
    • 2017
  • This paper deals with characteristics analysis of a permanent magnet (PM) linear generator using analytical methods for wave energy harvesting. The wave energy is carried out from the movement of a yo-yo system. A linear generator using permanent magnets to generate a magnetic force itself does not require a separate power supply and has the advantage of simple maintenance. In addition to the use of a rare earth, a permanent magnet having a high-energy density can be miniaturized and lightweight, and can obtain high energy-conversion efficiency. We derived magnetic field solutions produced by the permanent magnet and armature reaction based on 2D polar coordinates and magnetic vector potential. Induced voltage is obtained via arbitrary sinusoidal input. In addition, electrical parameters are obtained, such as back-EMF constant, resistance, and self- and mutual-winding inductances. The space harmonic method used in this paper is confirmed by comparing it with finite element method (FEM) results. These facilitate the characterization of the PM-type linear generator and provide a basis for comparative studies, design optimization, and machine dynamic modeling.

Assessment of subjective symptoms by 60Hz magnetic field in electromagnetic hypersensitivity (60Hz 자기장에 대한 과민 증후군의 자각증상 원인 평가)

  • Yang, Dong-In;Nam, Ki-Chang;Kwon, Min-Kyung;Kim, Deok-Won
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.721-732
    • /
    • 2010
  • As increasing of electrical device usage, social concerns about the possible effects of 60Hz electromagnetic fields (EMF) on human health have increased. The number of people with self-attributed electromagnetic hypersensitivity (EHS) who complain of subjective symptoms such as headache, insomnia etc. also increased. However, we don't know whether the EHS results from psychological factor or real perception to the electromagnetic field. In this study, we simultaneously investigated physiological changes(heart rate, respiration rate, heart rate variability, alpha and beta waves in EEG), subjective symptoms and perception accuracy to assess origins of subjective symptoms according to the EMF exposure. Experiment consists of real and sham sessions and 60Hz 12.5uT magnetic field was on(real) or off(sham) to 15 EHS and 16 nonEHS. As the results, EMF exposure did not have any effects on physiological parameters or subjective symptoms for both groups. There was also no evidence that EHS group perceived the EMFs correctly than the control group. Therefore, the origins of subjective symptoms is not the 60Hz magnetic field but psychological factors.

  • PDF

Development of Solenoid RF Coil for Animal Imaging in 3T High Magnetic Field MRI (고자장 3T MRI 장비에서 동물영상을 위한 솔레노이드 RF코일 개발)

  • Lee, Hong-Seok;Woo, Dong-Cheol;Min, Kwang-Hong;Kim, Yong-Kwon;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.20-26
    • /
    • 2007
  • Purpose : The purpose of the present study was to develop and optimize solenoid coil for animal- model in 3 T MRI system and investigate and compare with the birdcage coil concerning the image quality with the various parameters such as SNR and Q-factor. Materials and Methods : Solenoid coil for animal-model was made on the acryl structure (diameter 4 cm, length 10 cm) 3 times-winding cooper tape of width 2 cm, thickness 0.05 cm and length 10 cm with 2 cm interval between winded tapes. Capacitors from 2 pF to 100 pF were used, and the solenoid coil was designed for receiver only coil. Results : SNR of the developed solenoid was 985 in CuSO4 0.7 g/L and 995 in rat experiment. Q-factor was 84-89 in unloaded condition and 203-206 in loaded condition. Conclusion : The resolution of the image obtained from solenoid was relatively higher than that of the conventional birdcage coil. In addition, the homogeneity of RF field by coil simulation was significantly excellent. The present study demonstrated that the solenoid coil could be useful to obtain small animal images with better contrast, resolution, visibility than images from birdcage.

  • PDF

Pharmacokinetics and Bio-distribution of New Gd-complexes of DTPA-bis (amide) (L3) in a Rat Model (쥐를 이용한 새로운 가돌리늄 조영제 Gd-DTPA-bis(amide)(L3)의 약동학 및 생체내 분포 특성에 대한 연구)

  • Yan, Gen;Wu, Renhua;Chang, Yongmin;Kang, Duksik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.259-266
    • /
    • 2013
  • Purpose : To investigate the blood pharmacokinetics and bio-distribution of DTPA-bis-amide (L3) Gd(III) complexes. Materials and Methods: The pharmacokinetics and bio-distribution of Gd $(L3)(H_2O){\cdot}nH_2O$ were investigated in Sprague-Dawley rats after intravenous administration at a dose of 0.1 mmol Gd/kg. The Gd content in the blood, various tissues, and organs was determined by ICP-AES. Blood pharmacokinetic parameters were calculated using a two-compartment model. Results: The half-lives of ${\alpha}$ phase and ${\beta}$ phase Gd $(L3)(H_2O){\cdot}nH_2O$ were $2.286{\pm}0.11$ min and $146.1{\pm}7.5$ min, respectively. The bio-distribution properties reveal that the complex is mainly excreted by the renal pathway, and possibly excreted by the hepatobiliary route. The concentration ratio of Gd (III) was significantly higher in the liver and spleen than in other organs, and small amounts of Gd (III) ion were detected in the blood or other tissues of rats only after 7 days of intravenous administration. Conclusion: The MRI contrast agent Gd $(L3)(H_2O){\cdot}nH_2O$ provides prolonged blood pool retention in the circulation and then clears rapidly with minimal accumulation of Gd(III) ions. The synthesis of gadolinium complexes with well-balanced lipophilicity and hydrophilicity shows promise for their further development as blood pool MRI contrast agents.

Biaxial Buckling Analysis of Magneto-Electro-Elastic(MEE) Nano Plates using the Nonlocal Elastic Theory (비국소 탄성이론을 이용한 자기-전기-탄성 나노 판의 2방향 좌굴 해석)

  • Han, Sung-Cheon;Park, Weon-Tae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.5
    • /
    • pp.405-413
    • /
    • 2017
  • In this paper, we study the biaxial buckling analysis of nonlocal MEE(magneto-electro-elastic) nano plates based on the first-order shear deformation theory. The in-plane electric and magnetic fields can be ignored for MEE(magneto-electro-elastic) nano plates. According to magneto-electric boundary condition and Maxwell equation, the variation of magnetic and electric potentials along the thickness direction of the MME plate is determined. In order to reformulate the elastic theory of MEE(magneto-electro-elastic) nano-plate, the nonlocal differential constitutive relations of Eringen is used. Using the variational principle, the governing equations of the nonlocal theory are discussed. The relations between nonlocal and local theories are investigated by computational results. Also, the effects of nonlocal parameters, in-plane load directions, and aspect ratio on structural responses are studied. Computational results show the effects of the electric and magnetic potentials. These computational results can be useful in the design and analysis of advanced structures constructed from MEE(magneto-electro-elastic) materials and may be the benchmark test for the future study.

Clinical Experience of 3T Breast MRI in Detecting the Additional Lesions in Breast Cancer Patients (유방암 환자에서 추가 병변 평가를 위한 3 테슬러 유방자기공명영상의 임상적 경험)

  • Lee, Ji-Hye;Kim, Sung-Hun;Kang, Bong-Joo;Choi, Jae-Jeong;Lee, Ah-Won
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.121-125
    • /
    • 2010
  • Purpose : The purpose of this study was to evaluate the diagnostic accuracy of 3.0-T breast MRI for detecting additional breast cancer soon after the initial diagnosis of breast cancer. Materials and Methods : From March to June 2009, 101 patients recently diagnosed breast cancer underwent breast MRI and surgery. Parameters analyzed on MRI were total extent of tumor, suspicious findings of multifocal, multicentric, or contralateral cancer. The diagnosis of MRI-detected cancer was confirmed by means of biopsy or surgical specimen evaluation after the localization. Results : MRI showed 37 additional suspicious findings in 34 patients. Twenty nine findings were true-positive (29/37, 78.4%), including 16 cases of multifocality, 11 cases of multicentricity and 2 cases of contralateral cancer. Among these cancers, 13 (44.8%) were ductal carcinoma in situ (DCIS) and 16 (55.1%) were infiltrating cancer. Eight findings were false-positive (8/37, 21.6%) including 6 cases of benign disease and 2 cases of high-risk lesions. Conclusion : In women with recently diagnosed breast cancer, 3.0-T MR imaging showed additional suspicious findings in 33.7%. The sensitivity and specificity for detecting additional breast cancer was 100% and 89.3%, respectively.

Synthesis and Magnetic Properties of Zn, Co and Ni Substituted Manganese Ferrite Powders by Sol-gel Method

  • Kwon, Woo-Hyun;Kang, Jeoung-Yun;Lee, Jae-Gwang;Lee, Seung-Wha;Chae, Kwang-Pyo
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.159-164
    • /
    • 2010
  • The Zn, Co and Ni substituted manganese ferrite powders, $Mn_{1-x}$(Zn, Co, Ni)$_xFe_2O_4$, were fabricated by the solgel method, and their crystallographic and magnetic properties were studied. The Zn substituted manganese ferrite, $Zn_{0.2}Mn_{0.8}Fe_2O_4$, had a single spinel structure above $400^{\circ}C$, and the size of the particles of the ferrite powder increased when the annealing temperature was increased. Above $500^{\circ}C$, all the $Mn_{1-x}$(Zn, Co, Ni)$_xFe_2O_4$ ferrite had a single spinel structure and the lattice constants decreased with an increasing substitution of Zn, Co, and Ni in $Mn_{1-x}$(Zn, Co, Ni)$_xFe_2O_4$. The Mossbauer spectra of $Mn_{1-x}Zn_xFe_2O_4$ (0.0$\leq$x$\leq$0.4) could be fitted as the superposition of two Zeeman sextets due to the tetrahedral and octahedral sites of the $Fe^{3+}$ ions. For x = 0.6 and 0.8 they showed two Zeeman sextets and a single quadrupole doublet, which indicated they were ferrimagnetic and paramagnetic. And for x = 1.0 spectrum showed a doublet due to a paramagnetic phase. For the Co and Ni substituted manganese ferrite powders, all the Mossbauer spectra could be fitted as the superposition of two Zeeman sextets due to the tetrahedral and octahedral sites of the $Fe^{3+}$ ions. The variation of the Mossbauer parameters are also discussed with substituted Zn, Co and Ni ions. The increment of the saturation magnetization up to x = 0.6 in $Mn_{1-x}Co_xFe_2O_4$ could be qualitatively explained using the site distribution and the spin magnetic moment of substituted ions. The saturation magnetization and coercivity of the $Mn_{1-x}$(Zn, Co, Ni)$_xFe_2O_4$ (x = 0.4) ferrite powders were also compared with pure $MnFe_2O_4$.

Mössbauer Study on the Variation in Magnetic Properties of CuO Induced by 57Fe Addition (57Fe 이온이 CuO에 미치는 효과에 관한 Mössbauer 분광 연구)

  • Park, Jae-Yun;Kim, Kwang-Joo
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.3
    • /
    • pp.113-119
    • /
    • 2009
  • $^{57}Fe_xCu_{1-x}O$(x = 0.0, 0.02) powders were prepared by sol-gel method and their crystallographic and magnetic hyperfine properties have been studied using X-ray diffraction and $M{\ddot{o}}ssbauer$ spectroscopy (MS). The crystal structure of the samples is found to be monoclinic without any secondary phases and their lattice parameters increase with increasing annealing temperature ($T_A$), which is attributed to an increase in oxygen-vacancy content. MS measurements at room temperature indicate that $Fe^{3+}$ ions substitute $Cu^{2+}$ sites and ferromagnetic phase grow with increasing $T_A$. Magnetic hyperfine and quadrupole interactions of $^{57}Fe_{0.02}Cu_{0.98}O$ ($T_A=500^{\circ}C$) in the antiferromagnetic state at 17 K have been studied, yielding the following results: $H_{hf}=426.94\;kOe$, ${\Delta}E_Q=-3.67\;mm/s$, I.S.=0.32 mm/s, ${\theta}=65^{\circ}$, ${\phi}=0^{\circ}$, and ${\eta}=0.6$.

Electron Magnetic Resonance Study of Paramagnetic Impurities in LiTaO3 and LiMbO3 Single Crystals (LiTaO3 및 LiMbO3 단결정 내의 상자성 불순물에 관한 전자 자기공명 연구)

  • Yeom, Tae-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.5
    • /
    • pp.204-210
    • /
    • 2003
  • Electron magnetic resonance (EMR) of paramagnetic Cr$^{3+}$, Mn$^{2+}$, and Fe$^{3+}$ impurity ions in ferroelectric LiNbO$_3$ and LiTaO$_3$ single crystals has been studied. The actual sites location of paramagnetic impurity ions in the crystals was suggested from the experimental results and zero field splitting parameters calculated by superposition model. It turns out that Cr$^{3+}$ ions in LiNbO$_3$ crystal have two resonance centers and enter both the Li$^{+}$ and Nb$^{5+}$ ions. Mn$^{2+}$ and Fe$^{3+}$ impurity ions in LiNbO$_3$ substitute for Nb$^{5+}$ ions. However, both Cr$^{3+}$ and Fe$^{3+}$ ions in LiTaO$_3$ crystal reside at Li$^{+}$ ions.$ +/ ions.+/ ions.

High Frequency Magnetic Characteristics of $Co_{90}Fe_{10}$ Thin Films and $Co_{90}Fe_{10}/SiO_2$ Multilayers ($Co_{90}Fe_{10}$ 박막 및 $Co_{90}Fe_{10}/SiO_2$ 다층박막의 고주파 자기특성)

  • 윤의중;진현준;박노경;문대철;김좌연
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.5
    • /
    • pp.300-307
    • /
    • 1998
  • The $Co_{90}Fe_{10}$ single layer films were deposited on various substrates (glass, Si, polymide) using high vacuum RF magnetron sputtering system and nominall 1000 $\AA$ thick $Co_{90}Fe_{10}$ alloy films had a good high frequency characteristic. $M_S$ and $H_{an}$ values obtained from the B-H characteristic of the $10{\times}[100 nm \;Co_{90}Fe_{10}/100 nm\; SiO_2]$ multilayers agreed well with those obtained by calculation. Complex relative permeability $(={\{\mu}_r={\mu}_r',-j{\mu}$\mu$_r")$ at frequency f was measured from the transmission characteristics $(S_{11},\; S_{21}\;parameters)$ of the microstrip line which has a stacked structure consisting of sample magnetic films and a conductor and is connected to a network analyzer. The ${\mu}_r'-f$ characteristic was abtained from the megnetic absorption, which was analyzed from the S-parameter characteristics of the microstrip line. The ${\mu}_r'-f$ characteristic was also calculated from the ${\mu}_r"-f$-f characteristic using the Kramers-Kronig relation. The measurement results were confirmed to agree well with those obtained by calculations.culations.

  • PDF