• 제목/요약/키워드: magnetic filter

검색결과 310건 처리시간 0.028초

DVR의 특성을 고려한 매칭변압기의 자속포화 해석 (Magnetic Flux Saturation Analysis of Matching Transformer Considering Characteristic of Dynamic Voltage Restorer(DVR))

  • 손진근;김동준;강민구;전희종
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.236-243
    • /
    • 2008
  • This paper analyses magnetic flux saturation of matching transformer considering characteristic of dynamic voltage restorer(DVR) system to solve voltage sags which are considered the dominant disturbances affecting power quality. This DVR consist of PWM inverter to inject arbitrary voltage, LC low pass filter and matching transformer for isolation and grid connection. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core of transformer. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, an advanced modeling method of magnetic flux saturation is used to analyze a magnitude and characteristic of magnetizing current. Simulation and experimental results considering characteristic of DVR system are provided to demonstrate the validity of the proposed analysis method.

중력 법칙을 이용한 전자나침반의 경사오차 및 비 수평오차 보정 (Inclination and Non-horizontal Error Correction of Magnetic Compass by the Law of Gravity)

  • 박계도;이장명
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.606-611
    • /
    • 2011
  • This paper proposes a correction method concerning the inclination error and non-horizontal error of magnetic compass when magnetic compass is vibrated. This system used the 2-axis variable resistance and pendulum. A pendulum hanging from the 2-axis variable resistance of this system is always maintain the horizontal because of gravity. but these data had some intrinsic error. So we used the low pass filter to solve this problem. So this system can get the accurate azimuth of magnetic compass. In conclusion, These results demonstrate convincingly by applied algorithm of experiment.

Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting

  • Lee, Jong Hyeok;Sohn, Hee Eon;Chung, Seung Young;Park, Moon Sun;Kim, Seong Min;Lee, Do Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권4호
    • /
    • pp.316-320
    • /
    • 2015
  • Objective : The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. Methods : From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid artery stenosis ${\geq}70%$ were treated with CAS with embolic protection device in single center. All patients underwent post-CAS diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic lesions. We compared clinical outcomes and postprocedural embolization rates. Results : CAS was performed in all 61 patients. Distal filter protection success rate was 96.6% (28/29), whose mean age was 70.9 years, and mean stenosis was 81%. Their preprocedural infarction rate was 39% (11/28). Subsequent DW-MRI revealed 96 new ischemic lesions in 71% (20/28) patients. In contrast, the proximal balloon occlusion device success rate was 93.8% (30/32), whose mean age was 68.8 years and mean stenosis was 86%. Preprocedure infarction rate was 47% (14/30). DW-MRI revealed 45 new ischemic lesions in 57% (17/30) patients. Compared with distal filter protection device, proximal balloon occlusion device resulted in fewer ischemic lesions per patient (p=0.028). In each group, type of stent during CAS had no significant effect on number of periprocedural embolisms. Only 2 neurologic events occurred in the successfully treated patients (one from each group). Conclusion : Transfemoral CAS with proximal balloon occlusion device achieves good results. Compared with distal filter protection, proximal balloon occlusion might be more effective in reducing cerebral embolism during CAS.

Nano-granular Co-Fe-Al-Q Soft Ferromagnetic Thin Films for RF Electromagnetic-noise Filters

  • Sohn, Jae-Cheon;Byun, Dong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권1호
    • /
    • pp.42-50
    • /
    • 2006
  • Co-Fe-Al-O nano-granular thin films with high electrical resistivity, fabricated by radio frequency magnetron sputtering under an $Ar+O_2$ atmosphere, are found to show good soft magnetic properties in the GHz frequency range. The real part value of the relative permeability is 260 at low frequencies and this value is maintained up to the GHz frequency range. A non-integrated type noise filter on a coplanar waveguide transmission line is demonstrated by using the Co-Fe-Al-O nano-granular thin film with the dimensions of $4\;mm(l){\times}4\;mm(w){\times}0.1\;{\mu}m(t)$. The insertion loss is very low being less than 0.3 dB and this low value is maintained up to 2 GHz. At a ferromagnetic resonance frequency of 3.3 GHz, the degree of noise suppression is measured to be 3 dB. This level of noise attenuation is small for real applications, but there is much room for further improvement by increasing the magnetic volume and integrating the magnetic thin film into the CPW transmission line.

하이브리드 AMB를 포함한 초전도 플라이휠 에너지 저장장치의 실험평가 (Experimental Evaluation of Superconductor Flywheel Energy Storage System with Hybrid Type Active Magnetic Bearing)

  • 이정필;김한근;한상철
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.195-202
    • /
    • 2012
  • In this paper, we designed Active Magnetic Bearing (AMB) for large scale Superconductor Flywheel Energy Storage System (SFESS) and PD controller for AMB. And we experimentally evaluated SFESS including hybrid type AMB. The radial AMB was designed to provide force slew rate that was sufficient for the unbalance disturbances at the maximum operating speed. The thrust AMB is a hybrid type where a permanent magnet carries the weight of the flywheel and an electromagnetic actuator generates the dynamic control force. We evaluated the design performance of the manufactured AMB through comparison of FEM analysis and the results of experimental force measurement. In order to obtain gains of PD controller and design a notch filter, the system identification was performed through measuring frequency response including dynamics for the AMBs, a power amp and a sensor using a sine swept test method after levitating the flywheel. Through measuring the current input of the AMBs and the orbit of a flywheel according to rotational speed, we verified excellent control performance of the AMBs with small amount current for the large scale SFESS.

Application of Electromagnetic Fields to Improve the Removal Rate of Radioactive Corrosion Products

  • Kong, Tae-Young;Lee, Kun-Jai;Song, Min-Chul
    • Nuclear Engineering and Technology
    • /
    • 제36권6호
    • /
    • pp.549-558
    • /
    • 2004
  • TTo comply with increasingly strict regulations for protection against radiation exposure, many nuclear power plants have been working ceaselessly to reduce and control both the radiation sources within power plants and the radiation exposure experienced by operational and maintenance personnel. Many research studies have shown that deposits of irradiated corrosion products on the surfaces of coolant systems are the main cause of occupational radiation exposure in nuclear power plant. These corrosion product deposits on the fuel-clad surface are also known to be main factors in the onset of axial offset anomaly (AOA). Hence, there is a great deal of ongoing research on water chermistry and corrosion processes. In this study, a magnetic filter with permanent magnets was devised to remove the corrosion products in the coolant stream by taking advantage of the magnetic properties of the corrosion products demonstrated a removal efficiency of over 90% for particles above 5${\mu}m$. This finding led to the construction of an electromagnetic device that causes the metallic particulates to flocculate into larger aggregates of about 5${\mu}m$ in diameter by using a novel application of electromagnetic flocculation on radioactive corrosion products.

자율무인잠수정의 지형참조항법 연구 (Terrain Referenced Navigation for Autonomous Underwater Vehicles)

  • 목성훈;방효충;권재현;유명종
    • 제어로봇시스템학회논문지
    • /
    • 제19권8호
    • /
    • pp.702-708
    • /
    • 2013
  • Underwater TRN (Underwater Terrain Referenced Navigation) estimates an underwater vehicle state by measuring a distance between the vehicle and undersea terrain, and comparing it with the known terrain database. TRN belongs to absolute navigation methods, which are used to compensate a drift error of dead reckoning measurements such as IMU (Inertial Measurement Unit) or DVL (Doppler Velocity Log). However, underwater TRN is different to other absolute methods such as USBL (Ultra-Short Baseline) and LBL (Long Baseline), because TRN is independent of the external environment. As a magnetic-field-based navigation, TRN is a kind of geophysical navigation. This paper develops an EKF (Extended Kalman Filter) formulation for underwater TRN. A filter propagation part is composed by an inertial navigation system, and a filter update is executed with echo-sounder measurement. For large-initial-error cases, an adaptive EKF approach is also presented, to keep the filter be stable. At the end, simulation studies are given to verify the performance of the proposed TRN filter. With simplified sensor and terrain database models, the simulation results show that the underwater TRN could support conventional underwater navigation methods.

능동 자기 베어링을 위한 동기 노치필터 제어기와 스위칭 제어기의 성능 비교 연구 (Comparative Study of Performance of Switching Control and Synchronous Notch Filter Control for Active Magnetic Bearings)

  • 유승열;노명규
    • 대한기계학회논문집A
    • /
    • 제37권4호
    • /
    • pp.511-519
    • /
    • 2013
  • 능동 자기베어링의 바이어스 선형화 방법은 자기베어링의 동역학적 성능과 선형성을 확보하지만, 바이어스 전류에 의한 상시 소모전력이 발생하여 시스템의 효율이 저하된다. 반면, 스위칭 제어기는 바이어스 전류를 사용하지 않아 베어링의 소비 전력을 최소화할 수 있다. 본 논문에서는 능동 자기베어링 시스템에 적용되는 스위칭 제어기와 동기 노치필터를 포함하는 비례-미분 제어기의 성능을 비교하였다. 공정하고 객관적인 비교를 위해 기준제어기인 동기 노치필터 제어기를 합리적으로 설계하고, 스위칭 제어기가 기준제어기와 동일한 동역학 특성을 갖도록 하였다. 회전축의 굽힘 유연모드 및 센서와 증폭기의 특성을 포함하는 시스템의 동역학 모델을 수립하고 성능 비교 지표를 수립하였다. 불평형 질량에 응답 측면에서 제어기를 비교하여, 저속 영역에서 스위칭 제어기가 기준제어기 대비 10 배 이상 동손을 저감할 수 있으나, 회전축의 굽힘 유연모드와 일치하는 회전 속도 근방에서는 스위칭 제어기가 유효하지 않음을 확인하였다.

FDTD 병렬화 알고리즘을 이용한 무선랜용 마이크로스트립 대역통과 펄터 설계 (The Design of Microstrip Bandpass Filter for Wireless LAN using FDTD Parallel Algorithm)

  • 최성열;박경수;고영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권7호
    • /
    • pp.395-400
    • /
    • 2004
  • In this paper, the four-pole elliptic function microstrip filter at 2.4GHz band with fractional bandwidth of 4% is realized using compact miniaturized hairpin resonators. The parallel algorithm FDTD method is used to analyze S-parameter of hairpin resonator filter more accurately, and to calculate the electric coupling and magnetic coupling among the hairpin resonators. Absorbing boundary conditions for mesh termination used Sulivan's simplified PML and the FDTD code was paralleled by MPI for IBM SP2 which had enhanced calculation speed. The experimental measurements are performed by HP8720D vector network analyzer. Measured results on fabricated hairpin type cross coupled bandpass filters show good agreements with theoretic results.

EQUIVALENT CIRCUIT REPRENSENTATION OF MAGNETIC FIELDS BASED ON FINITE ELEMENT MODELLING

  • Y. Kagawa;N. Wakatsuki;Kim, A. ura
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2001년도 The Seoul International Simulation Conference
    • /
    • pp.205-208
    • /
    • 2001
  • A lumped electrical circuit is an approximate representation of the field within a curtain frequency range. The finite element modelling is a synonym of the equivalent circuit. The electric conduction field and electric potential wave field have been modelled by an admittance network and an LC low-pass filter network. Here in the present paper, the equivalent magnetic circuit representation is created for a magnetostatic field by the finite element modelling in two dimension.

  • PDF