• Title/Summary/Keyword: magnetic field measurement

Search Result 516, Processing Time 0.027 seconds

A Study on the Wireless Ship Motion Measurement System Using AHRS (AHRS를 이용한 무선 선체 운동 측정 시스템에 관한 연구)

  • Kim, Dae-Hae;Lee, Sang-Min;Kong, Gil-Young
    • Journal of Navigation and Port Research
    • /
    • v.37 no.6
    • /
    • pp.575-580
    • /
    • 2013
  • The IMU(Inertial Measurement Unit) which is the expensive equipment has been used as a special limited area, usually in measurement of posture of applying to the areas of ship, submarine, aircraft and military equipment application. However, in the current situation, MEMS AHRS technology can replace the high-priced IMU in MEMS AHRS selected application field. In this paper, wireless hull motion measurement system was suggested for measuring key elements of ship's movement such as rolling, pitching and yawing using gyro, acceleration and magnetic sensors of AHRS. In order to reduce the error such as instantaneous acceleration, effects and vibration of geomagnetic, we have adopted the sensors equipped with Kalman filtering. The Wireless hull motion measurement system using AHRS sensors was tested in actual ship and it could easily be applied in limited installation circumstances of the ship. In the future, this system can be useful in the navigation safety and marine accident analysis by using with ship equipment such as INS or VDR in the maritime.

The Influence of W Addition on Cube Textured Ni Substrates for YBCO Coated Conductor (양축 정렬된 Ni 기판의 특성에 미치는 W 첨가의 효과)

  • Kim Kyu Tae;Lim Jun Hyung;Kim Jung Ho;Jang Seok Hern;Kim Ho-Jin;Joo Jinho;Kim Chan-Joong;Song Kyu Jung;Shin Hyung Sub
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.64-68
    • /
    • 2004
  • We fabricated cube-textured Ni and Ni-W alloy substrates for coated conductors and characterized the effects of W addition on microstructure, mechanical strength, and magnetic properties of the substrate. Pure Ni and Ni-(2, 3, 5at.%)W alloys were prepared by plasma arc melting, heavily cold rolled and then annealed at various temperatures of $600-1300^{\circ}C$. The texture was evaluated by pole-figure and orientation distribution function (ODF) analysis. Mechanical properties were investigated by micro Vickers hardness and tension test. Ferromagnetism of the substrate was measured by physical property measurement system (PPMS). It was observed that Ni-W substrates had sharp cube texture, and the full-width at half-maximums (FWHMs) of in-plane texture was $^{\circ}$-5.57$4.42^{\circ}$, which is better than that of pure Ni substrate. In addition cube texture of Ni-W substrates was retained at higher temperature up to $1300^{\circ}C$. Microstructural observation showed that the Ni-W substrates had fine grain size and higher mechanical properties than the pure Ni substrate. These improvements are probably due to strengthening mechanisms such as solid solution hardening and/or grain size strengthening. PPMS analysis showed that addition of W effectively reduced saturation magnetization in applied magnetic field and Curie temperature.

  • PDF

Junction Capacitance Dependence of Response Time for Magnetic Tunnel Junction (터널링 자기저항 소자의 접합면 정전용량에 따른 전기적 응답특성)

  • Park, S.Y.;Choi, Y.B.;Jo, S.C.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.2
    • /
    • pp.68-72
    • /
    • 2002
  • In this research, the effects of capacitance to the access time were studied at the junction area of tunneling magnetoresistance when these were used as memory devices. These results were obtained by applying electric signal input and magnetic field was not used. We applied bipolar square waves of 1MHz to the MTJ samples to obtain the results and time constant ($\tau$) calculated by observing wave responses utilizing an oscilloscope. And time constant was compared with junction area. Each part of MTJ sample, such as electrical pad, lead and contact area, was modeled as an electrical equivalent circuit based on experimental results. For the 200㎛$\times$200㎛ cell, junction capacitance was 90 pF. Also, measurement and simulation results were compared, which showed those similarity.

Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study

  • Lee, Woo Yeon;Kim, Min Jung;Lew, Dae Hyun;Song, Seung Yong;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.430-437
    • /
    • 2016
  • Background Accurate breast volume assessment is a prerequisite to preoperative planning, as well as intraoperative decision making in breast reconstruction surgery. The use of three-dimensional surface imaging (3D scanning) to assess breast volume has many advantages. However, before employing 3D scanning in the field, the tool's validity should be demonstrated. The purpose of this study was to confirm the validity of 3D-scanning technology for evaluating breast volume. Methods We reviewed the charts of 25 patients who underwent breast reconstruction surgery immediately after total mastectomy. Breast volumes using the Axis Three 3D scanner, water-displacement technique, and magnetic resonance imaging (MRI) were obtained bilaterally in the preoperative period. During the operation, the tissue removed during total mastectomy was weighed and the specimen volume was calculated from the weight. Then, we compared the volume obtained from 3D scanning with those obtained using the water-displacement technique, MRI, and the calculated volume of the tissue removed. Results The intraclass correlation coefficient (ICC) of breast volumes obtained from 3D scanning, as compared to the volumes obtained using the water-displacement technique and specimen weight, demonstrated excellent reliability. The ICC of breast volumes obtained using 3D scanning, as compared to those obtained by MRI, demonstrated substantial reliability. Passing-Bablok regression showed agreement between 3D scanning and the water-displacement technique, and showed a linear association of 3D scanning with MRI and specimen volume, respectively. Conclusions When compared with the classical water-displacement technique and MRI-based volumetry, 3D scanning showed significant reliability and a linear association with the other two methods.

Measurement of Viscoelastic Constants from Multiple Phase MR Elastography Fitting Elastic Wave (탄성파를 적용한 다중 위상 MR Elastography로부터의 점탄성 정수의 측정)

  • Jung, Nam-Chae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.3
    • /
    • pp.119-129
    • /
    • 2012
  • In the medical field, the hardening of tissues is one of important informations used in diagnosis or understanding progress of disease, a quantitative measuring method of hardening is important for objective diagnosis. It has been proposed MRE(Magnetic Resonance Elastography) method that measures an index of hardening, viscoelastic properties in a noninvasive. Because the S/N ratio of MRE images go down when measuring viscoelastic properties from local wavelength and local damping factor of a propagating wave in MRE method, methods using multiple phase MRE images have been examined to decrease the effect of noise. We propose a method measuring viscoelastic properties after Fitting a function for multiple phase MRE images in this research. This proposed method has a advantage to set up arbitrarily the variation rate of a space direction of viscoelastic properties or the spatial resolution of measuring values according to changing of the noise included in images, though it applies viscoelastic wave for multiple phase MRE images. We confirmed the effectiveness of a proposed method by experiment using simulation images and experiment using silicone-gel phantom.

Construction of 3-Axis Flux-gate Magnetometer for Attitude Control of Satellite (인공위성의 자세제어용 3-축 Flux-gate 마그네토미터 제작)

  • Son, De-Rac
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.3
    • /
    • pp.182-185
    • /
    • 2006
  • In this work, we have constructed 3-axis flux-gate magnetometer for the attitude control of satellite. The constructed magnetometer shows uncertainty of ${\pm}1%$, noise level of $0.2nT/\sqrt{Hz}$ at 1 Hz under 1W power consumption. Environment test for satellite component, acceleration test and thermal cycle test were carried out. For the acceleration test, magnetometer was vibrated frequency ranging from 10 Hz to 1 kHz at 15 g (g : gravitational acceleration at earth), and for thermal cycle test, 4 times of thermal cycle were carried out temperature ranging from $-55^{\circ}C\;to\;+80^{\circ}C$ under vacuum of $1x10^{-6}Torr$.

Relation Between Magnetization Easy Axis and Anisotropic Magnetoresistance in Permalloy Films (퍼멀로이 박막의 자화 용이축과 자기저항 변화와의 상관관계에 대한 연구)

  • Hwang, Tae-Jong;Ryu, Yeung-Shik;Kwon, Jin-Hyuk;Kim, Ki-Hyeon;Kim, Dong-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.1
    • /
    • pp.28-31
    • /
    • 2008
  • We studied the effect of easy magnetization axis orientation with respect to the strip direction by measuring the magnetoresistance(MR), the magneto-optic Kerr effect(MOKE), and real-time domain evolution. The five strips were patterned on a single chip with the easy axis orientation of each strip relative to the longitudinal direction by around $0^{\circ}$, $18^{\circ}$, $36^{\circ}$, $54^{\circ}$ and $72^{\circ}$, respectively. The overall shape of field dependent MR was mostly governed by the anisotropy magnetoresistnace. The relative change of the longitudinal MR was significantly increased with increasing angle between the easy axis and strip direction, whereas, the transverse MR variation rate was decreased with increasing angle. Several MR steps were observed during the magnetization reversal, and the simultaneous measurement of the MOKE and the domain images identified that the MR steps were associated with evolution of the oppositely directed magnetic domain.

A Study on the EMS Analysis of Image Variations for EUT (EUT의 영상변화에 의한 EMS 해석에 관한 연구)

  • Yun, Ki-Bang;Lee, Chang-Bok;Jung, Ki-Beom;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.2
    • /
    • pp.76-83
    • /
    • 2002
  • In this paper, we developed the real-time automation program for the immunity test according to the determination of the EUT image, and analyzed the image of standard PC monitor and the monitor image affected by the electromagnetic field. The image change detection algorithm was realized for the real-time determination of the malfunction, and we attempted to obtain the consistent results for the electromagnetic immunity measurement. We showed the possibility to determine the immunity of the PC monitor and other equipment by performing the image change detection of EUT, and the experimental results for the EUT immunity determination of EMS (Electro-Magnetic Susceptibility, IEC 61000-4-3) are also proposed in line with the international standard and domestic trends. 

The Superconducting Properties of a High-Temperature Superconducting GdBCO-Coated Conductor (고온초전도 GdBCO 박막선재의 초전도 특성)

  • Yang, Seok Han;Song, Kyu Jeong
    • New Physics: Sae Mulli
    • /
    • v.68 no.12
    • /
    • pp.1293-1301
    • /
    • 2018
  • The basic magnetic properties of commercially available High-$T_c$ Superconductor (HTS) GdBCO-coated conductor (GdBCO-CCs) were investigated by using physical property measurement system-vibrating sample magnetometer (PPMS-VSM). From the zero-field-cooled (ZFC) m(T) curve, the $T_c$ was found to be ~93 K. After removing the background m(H) data, we obtained both the net m(H) data and the ${\Delta}m_{irr}$. The $H_{irr}(T)$ coincided very well with the power-law relation $H_{irr}=H_{irr}(0)(1-T/T_c)^n$ with $$n{\sim_=}1.19$$. The magnetic flux behavior was investigated by using the ${\delta}$ values in the relationship $J_c{\propto}{\Delta}m_{irr}{\propto}H^{-{\delta}}$. A ${\delta}{\approx}0$ region denoting an independent magnetic flux pinning effect, a ${\delta}{\approx}0.6{\sim}1.2$ region representing a collective flux pinning effect due to the interaction, and a ${\delta}{\gg}2$ region representing freely moving magnetic fluxes caused by the Lorentz force were observed. The boundary line between ${\delta}{\approx}0$ and ${\delta}{\approx}0.6{\sim}1.2$ is denoted by a $H_1$, and the one between ${\delta}{\approx}0.6{\sim}1.2$ and ${\delta}{\gg}2$ is denoted by a $H_2$. The ${\delta}(T)$ was obtained in the region of $H_1$ < H < $H_2$. As the temperature was decreased, the ${\delta}$ value gradually decreased.

Design and Fabrication of an Electromagnetic Flowmeter (전자기유량계의 설계 및 제작)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1385-1392
    • /
    • 2003
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The developed EMF was designed as the 100 mm nominal diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. In order to obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF. For the characterization of the developed EMF, the uncertainty of calibrator was estimated within $\pm$0.5 %. The evaluation procedure of the uncertainty followed the ISO Guide to the Expression of Uncertainty in Measurement. It was found that the flow signals between the electrodes were about $\pm$60-$\pm$300$\mu$V, which were sufficient for the discrimination of flowmeter and the protection of noise. The test results against the calibrator showed the good linearity in the range of 3 ㎥/h and 70 ㎥/h. A commercialized design of the EMF based on the current study will be technically more competitive in domestic and foreign market.