Construction of 3-Axis Flux-gate Magnetometer for Attitude Control of Satellite

인공위성의 자세제어용 3-축 Flux-gate 마그네토미터 제작

  • Published : 2006.06.01

Abstract

In this work, we have constructed 3-axis flux-gate magnetometer for the attitude control of satellite. The constructed magnetometer shows uncertainty of ${\pm}1%$, noise level of $0.2nT/\sqrt{Hz}$ at 1 Hz under 1W power consumption. Environment test for satellite component, acceleration test and thermal cycle test were carried out. For the acceleration test, magnetometer was vibrated frequency ranging from 10 Hz to 1 kHz at 15 g (g : gravitational acceleration at earth), and for thermal cycle test, 4 times of thermal cycle were carried out temperature ranging from $-55^{\circ}C\;to\;+80^{\circ}C$ under vacuum of $1x10^{-6}Torr$.

본 연구에서는 인공위성의 자세제어용으로 사용될 3-축 flux-gate 마그네토 미터를 개발 제작하였다. 제작된 3-축의 flux-gate 마그네토 미터는 소비전력이 1W 미만에서 정확도는 ${\pm}1%$ 이내였으며 noise는 1Hz에서 $0.2nT/\sqrt{Hz}$이였다. 또한 제작된 마그네토미터를 인공위성에 적용하기 위한 환경시험을 수행하였다. 환경시험으로 가속도시험은 진동주파수의 범위가 $10Hz{\sim}1000Hz$에서 15g(g : 지구의 중력가속도)의 가속도에서 수행하였고, themal cycle 시험은 $1x10^{-6}$ Torr의 진공에서 $-55^{\circ}C{\sim}80^{\circ}C$의 온도 사이에서 24시간 동안 4회의 thermal cycle 시험을 한 결과 모두 정상 작동 되었다.

Keywords

References

  1. Von Hans Aschenbrenner and Georg Goubau, Hochfrequenztechnik und Elektroakustik, 176 (1936)
  2. M. H. Acuna and C. J. Pellerin, IEEE Trans on Geo. Elect., 7(4), 252 (1969) https://doi.org/10.1109/TGE.1969.271360
  3. F. Primdahl, J. of Physics E Sci. Instrum., 12, 241 (1979) https://doi.org/10.1088/0022-3735/12/4/001
  4. 손대락, 자기감시부 성능 최적화 기법 연구, 국방과학연구소 NSDC-409-020472 (2002)