• Title/Summary/Keyword: magnetic curves

Search Result 254, Processing Time 0.023 seconds

Characteristics Analysis of Disk-type Single Phase SRM (Disk형 단상 스위치드 리럭턴스 전동기의 특성 해석)

  • Lee, Chung-Won;Lee, Eun-Woong;Lee, Jong-Han;Oh, Young-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.988-990
    • /
    • 2003
  • Disk type Single Phase SRM(Switched Reluctance Motor) can be used axial and radial direction magnetic flux. Therefore, the energy density per unit of volume is high and the axis can be shorter than that of any other motor. In this paper, the flux-linkage was measured according as rotor positions of disk type single phase SRM, which is designed and fabricated in previous studies. From the measured data, we got the magnetization curves, inductance profile, co-energy and torque. Also, we compared the value of the measurement with the value of analysis through 3D FEM simulation.

  • PDF

Characteristic Analysis of Double-side Linear Pulst Motor (양측식 리니어 펄스 모터의 특성 해석)

  • Kim, Sung-Jong;Lee, Eun-Woong;Kim, Sung-Hun;Lee, Dong-Joo;Woo, Sung-Bong;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.232-234
    • /
    • 2000
  • Double-side LPM may be replaced the solenoid as the valve driving device with out difficulty and give full play to control the valve accurately. Double-side LPM's magnetic structure is so complex by the cubic effect configuration that finite element analysis is required. Thus, in this paper, by 2D and 3D finite element analysis, we get the flux distribution and static thrust force curves of designed double side LPM.

  • PDF

Frequency characteristics of a multiferroic Piezoelectric/LEMV/CFRP/Piezomagnetic composite hollow cylinder under the influence of rotation and hydrostatic stress

  • Selvamani, R.;Mahesh, S.;Ebrahimi, F.
    • Coupled systems mechanics
    • /
    • v.10 no.2
    • /
    • pp.185-198
    • /
    • 2021
  • An analytical model is consider to scrutinize axisymmetric wave propagation in multiferroic hollow cylinder with rotating and initial stressed forces, where a piezomagnetic (PM) material layer is bonded to a piezoelectric (PE) cylinder together by Linear elastic materials with voids. Both distinct material combos are taken into account. Three displacement potential functions are introduced to uncouple the equations of motion, electric and magnetic induction. The numerical calculations are carried out for the non-dimensional frequency by fixing wave number and thickness. The arrived outputs are plotted as the dispersion curves for different layers. The results obtained in this paper can offer significance to the application of PE/PM composite hollow cylinder via LEMV and CFRP layers for the acoustic wave and microwave technologies.

Regional Distribution of Isotropy Magnetic Property of Dual-type Giant Magnetoresistance-Spin Valve Multilayer (이중구조 거대자기저항-스핀밸브 박막의 자기등방성 영역분포에 관한 연구)

  • Khajidmaa, Purevdorj;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.6
    • /
    • pp.193-199
    • /
    • 2013
  • The regional distribution of magnetic isotropy depending on the post annealing condition for the dual-type structure GMR-SV (giant magnetoresistance-spin valve) of NiFe/Cu/NiFe/IrMn/NiFe/Cu/NiFe multilayer was investigated. The rotation of in-plane ferromagnetic layer induced by controlment of the post annealing temperature inside of the vacuum chamber. The magnetoresistive curves of a dual-type IrMn based GMR-SV depending on the direction of the magnetization easy axis of the free layer and the pinned layer are measured by between $0^{\circ}$ and $360^{\circ}$ angles for the applied fields. The optimum annealing temperature having a steady and isotropy magnetic sensitivity of 1.52 %/Oe was $107^{\circ}C$ in the rotational section of $0{\sim}90^{\circ}$. By investigating the switching process of magnetization for an arbitrary measuring direction, the in-plane orthogonal magnetization for the dual-type GMR-SV multilayer can be used by a high sensitive biosensor for detection of magnetized micro-beads.

Effects of Ultrathin Co Insertion Layer on Magnetic Anisotropy and GMR Properties of NiFe/Cu/Co Spin Valve Thin Films (NiFe/Cu 계면에 삽입된 Co 층이 NiFe/Cu/Co 스핀밸브 박막의 거대자기저항 특성과 자기이방성에 미치는 영향)

  • 김형준;조권구;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.5
    • /
    • pp.251-255
    • /
    • 1999
  • NiFe(60 $\AA$)/Co(0$\AA$$\leq$x$\AA$$\leq$15$\AA$)/Cu(60$\AA$)/Co(30$\AA$) spin valve thin films were prepared on 4$^{\circ}$ tilt-cut Si(111) substrates with a 50 $\AA$ thick Cu underlayer without applying any external magnetic field during the deposition, and the effects of inserted ultrathin Co layer on magnetic anisotropy and GMR properties of the NiFe(60 $\AA$)/Cu(60$\AA$)/Co(30$\AA$) spin valves were investigated. As the ultrathin Co layer was inserted into the NiFe/Cu interface of the spin valves, GMR ratio was increased from about 1.5% to 3.5%, and the easy axis of NiFe(60 $\AA$) layer was rotated by 90$^{\circ}$. Accordingly, it was aligned along the same direction with the easy axis of Co(30 $\AA$)layer. Therefore, squared R-H curves was obtained in the spin valves, which is favorable properties for the digital GMR devices such as MRAM. In order to investigate the change of magnetic anisotropy of NiFe layer of the spin valves in more details,XRD measurement was performed using NiFe(500 $\AA$) and NiFe(500 $\AA$)/Co(10 $\AA$) thin films on the same templates. Strong (220) NiFe peak was observed in both films regardless of the inserted Co layer, so it was thought that the variation of magnetic anisotropy of NiFe layer is from the interface effect, the change of interface from NiFe/Cu to NiFe/Co, rather than the volume effect such as the change of magnetocrystalline effect.

  • PDF

Multiferroic Property and Crystal Structural Transition of BiFeO3-SrTiO3 Ceramics

  • Kim, A-Young;Han, Seung-Ho;Kim, Jeong-Seog;Cheon, Chae-Il
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.4
    • /
    • pp.307-311
    • /
    • 2011
  • Solid solutions of the (1-x)$BiFeO_3-xSrTiO_3$ ceramic system (x = 0~0.4) are explored here in attempts to obtain multiferroic properties in these systems. The polarization-electric field hysteresis, magnetization-magnetic field curves, and dielectric properties are also characterized. This solid-solution system shows a crystal structural transition from a noncentrosymmetric (R3c) structure to a centrosymmetric (Pm-3m) structure at 0.3 < x < 0.4. The solid solution ceramic shows unsaturated M-H behavior and low remanent magnetization over the composition region of 0.1 ${\leq}$ x ${\leq}$ 0.3. The $0.7BiFeO_3-0.3SrTiO_3$ system shows the largest value of $M_s$ at 0.17 emu/g and the smallest value of $H_c$ at 1.06 kOe. The P-E hysteresis curves were not saturated under an electric field as high as E = 70 kV/cm. This system is considered to have multiferroic characteristics in the composition range of 0.1 ${\leq}$ x ${\leq}$ 0.3.

Metabolic Changes in Patients with Parkinson's Disease after Stereotactic Neurosurgery by Follow-up 1H MR Spectroscopy

  • Choe, Bo-Young;Baik, Hyun-Man;Chun, Shin-Soo;Son, Byung-Chul;Kim, Moon-Chan;Kim, Bum-Soo;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.5 no.2
    • /
    • pp.99-109
    • /
    • 2001
  • Authors investigated neuronal changes of local cellular metabolism in the cerebral lesions of Parkinsonian symptomatic side between before and after stereotactic neurosurgery by follow-up 1H magnetic resonance spectroscopy (MRS). Patients with Parkinson's disease (PD) (n = 15) and age-matched normal controls (n = 15) underwen MRS examinations using a stimulated echo acquisition mode (STEAM) pulse sequence that provided 2${\times}$2${\times}$2 ㎤ (8ml) volume of interest in the regions of substantia nigra, thalamus, and lentiform nucleus. Spectral parameters were 20 ms TE, 2000 ms TR, 128 averages,2500 Hz spectral width, and 2048 data points. Raw data were processed by the SAGE data analysis package (GE Medical Systems). Peak areas of N-acetylaspartate (NAA), creatine (Cr), choline-containing compounds (Cho), inositols (Ins), and the sum (Glx) of glutamate and GABA were calculated by means of fitting the spectrum to a summation of Lorentzian curves using Marquardt algorithm. After blindly processed, we evaluated neuronal alterations of observable metabolite ratios between before and after stereotactic neurosurgery using Pearson product-moment analysis (SPSS, Ver. 6.0). A significant reduction of NAA/Cho ratio was observed in the cerebral lesion in substantia nigra of PD patient related to the symptomatic side after neurosurgery (P : 0.03). In thalamus, NAA/Cho ratio was also significantly decreased in the cerebral lesion including the electrode-surgical region (P : 0.03). A significant reduction of NAA/Cho ratio in lentiform nucleus was not oberved, but tended toward significant reduction after neurosurgery (P = 0.08). In particular, remarkable lactate signal was noted from the surgical thalamic lesions of 6 among 8 patients and internal segments of globus pallidus of 6 among 7 patients, respectively. Significant metabolic alterations of NAA/Cho ratio might reflect functional changes of neuropathological processes in the lesion of substantia nigra, thalamus, and lentiform nucleus, and could be a valuable finding fur evaluation of Parkinson's disease after neurosurgery. Increase of lactate signals, being remarkable in surgical lesions, could be consistent with a common consequence of neurosurgical necrosis. Thus, IH MRS could be a useful modality to evaluate the diagnostic and prognostic implications fur Parkinsons disease after functional neurosurgery.

  • PDF

Micro/Nanotribology and Its Applications

  • Bhushan, Bharat
    • Tribology and Lubricants
    • /
    • v.11 no.5
    • /
    • pp.128-135
    • /
    • 1995
  • Atomic force microscopy/friction force microscopy (AFM/FFM) techniques are increasingly used for tribological studies of engineering surfaces at scales, ranging from atomic and molecular to microscales. These techniques have been used to study surface roughness, adhesion, friction, scratching/wear, indentation, detection of material transfer, and boundary lubrication and for nanofabrication/nanomachining purposes. Micro/nanotribological studies of single-crystal silicon, natural diamond, magnetic media (magnetic tapes and disks) and magnetic heads have been conducted. Commonly measured roughness parameters are found to be scale dependent, requiring the need of scale-independent fractal parameters to characterize surface roughness. Measurements of atomic-scale friction of a freshly-cleaved highly-oriented pyrolytic graphite exhibited the same periodicity as that of corresponding topography. However, the peaks in friction and those in corresponding topography were displaced relative to each other. Variations in atomic-scale friction and the observed displacement has been explained by the variations in interatomic forces in the normal and lateral directions. Local variation in microscale friction is found to correspond to the local slope suggesting that a ratchet mechanism is responsible for this variation. Directionality in the friction is observed on both micro- and macro scales which results from the surface preparation and anisotropy in surface roughness. Microscale friction is generally found to be smaller than the macrofriction as there is less ploughing contribution in microscale measurements. Microscale friction is load dependent and friction values increase with an increase in the normal load approaching to the macrofriction at contact stresses higher than the hardness of the softer material. Wear rate for single-crystal silicon is approximately constant for various loads and test durations. However, for magnetic disks with a multilayered thin-film structure, the wear of the diamond like carbon overcoat is catastrophic. Breakdown of thin films can be detected with AFM. Evolution of the wear has also been studied using AFM. Wear is found to be initiated at nono scratches. AFM has been modified to obtain load-displacement curves and for nanoindentation hardness measurements with depth of indentation as low as 1 mm. Scratching and indentation on nanoscales are the powerful ways to screen for adhesion and resistance to deformation of ultrathin fdms. Detection of material transfer on a nanoscale is possible with AFM. Boundary lubrication studies and measurement of lubricant-film thichness with a lateral resolution on a nanoscale have been conducted using AFM. Self-assembled monolyers and chemically-bonded lubricant films with a mobile fraction are superior in wear resistance. Finally, AFM has also shown to be useful for nanofabrication/nanomachining. Friction and wear on micro-and nanoscales have been found to be generally smaller compared to that at macroscales. Therefore, micro/nanotribological studies may help def'me the regimes for ultra-low friction and near zero wear.

Properties of Exchange Bias Coupling Field and Coercivity Using the Micron-size Holes Formation Inside GMR-SV Film (GMR-SV 박막내 미크론 크기의 홀 형성을 이용한 교환결합세기와 보자력 특성연구)

  • Bolormaa, Munkhbat;Khajidmaa, Purevdorj;Hwang, Do-Guwn;Lee, Sang-Suk;Lee, Won-Hyung;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.4
    • /
    • pp.117-122
    • /
    • 2015
  • The holes with a diameter of $35{\mu}m$ inside the GMR-SV (giant magnetoresistance-spin valve) film were patterned by using the photolithography process and ECR (electron cyclotron resonance) Ar-ion milling. From the magnetoresistance curves of the GMR-SV film with holes measuring by 4-electrode method, the MR (magnetoresistance ratio) and MS (magnetic sensitivity) are almost same as the values of initial states. On other side hand, the $H_{ex}$ (exchange bias coupling field) and $H_c$ (coercivity) dominantly increased from 120 Oe and 10 Oe to 190 Oe and 41 Oe as increment of the number of holes inside GMR-SV film respectively. These results were shown to be attributed to major effect of EMD (easy magnetic domian) having a region positioned between two holes perpendicular to the sensing current. On the basis of this study, the fabrication of GMR-SV applying to the hole formation improved the magnetoresistance properties having the thermal stability and durability of bio-device.

Quantitative Analysis of Coumarins from Angelica gigas Using $^1H$-NMR

  • Yoo, Jong-Su;Ahn, Eun-Mi;Song, Myoung-Chong;Bang, Myun-Ho;Kim, Dong-Hyun;Han, Min-Woo;Kwak, Ho-Young;Lee, Dae-Young;Lyu, Ha-Na;Baek, Nam-In
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.573-577
    • /
    • 2008
  • $^1H$-Nuclear magnetic resonance (NMR) spectrometry was applied to the quantitative analysis of coumarins in the roots of Angelica gigas without any chromatographic purification. The experiment was performed by the analysis of each singlet germinal methyl, which was well separated in the range of 1.0-2.0 ppm in the $^1H$-NMR spectrum. The quantity of the compounds was calculated by the ratio of the intensity of each compound to the known amount of internal standard (dimethyl terephthalate). These results were compared with the conventional gas chromatography (GC) method. The contents of decursin and decursinol angelate in A. gigas were determined $1.98{\pm}0.07$, $1.13{\pm}0.08%$ in quantitative $^1H$-NMR method and $2.06{\pm}0.24$, $1.17{\pm}0.24%$ in GC method, respectively. The advantages of quantitative $^1H$-NMR analysis are that can be analyzed to identify and quantify, and no reference compounds required for calibration curves. Besides, it allows rapid and simple quantification for coumarins with an analysis time for only 10 min without any preprocessing.