• Title/Summary/Keyword: magnetic beads

Search Result 79, Processing Time 0.032 seconds

Biomarkers Screening Between Preoperative and Postoperative Patients in Pancreatic Cancer

  • Li, Pei;Yang, Juan;Ma, Qing-Yong;Wu, Zheng;Huang, Chen;Li, Xu-Qi;Wang, Zheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.7
    • /
    • pp.4161-4165
    • /
    • 2013
  • Objective: To investigate discriminating protein patterns and potential biomarkers in serum samples between pre/postoperative pancreatic cancer patients and healthy controls. Methods: 23 serum samples from PC patients (12 preoperative and 11 postoperative) and 76 from healthy controls were analyzed using matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) technique combined with magnetic beads-based weak cation-exchange chromatography (MB-WCX). ClinProTools software selected several markers that made a distinction between pancreatic cancer patients and healthy controls. Results: 49 m/z distinctive peaks were found among the three groups, of which 33 significant peaks with a P < 0.001 were detected. Two proteins could distinguish the preoperative pancreatic cancer patients from the healthy controls. About 15 proteins may be potential biomarkers in assessment of pancreatic cancer resection. Conclusion: MB-MALDI-TOF-MS method could generate serum peptidome profiles of pancreatic cancer and provide a new approach to identify potential biomarkers for diagnosis and prognosis of this malignancy.

The Method Development for Biomarker Diagnosis Based on the Aptamer-protein Crosslink (앱타머와 단백질간 가교를 이용한 바이오마커 진단 방법 개발)

  • Lee, Bo-Rahm;Kim, Ji-Nu;Kim, Byung-Gee
    • KSBB Journal
    • /
    • v.26 no.4
    • /
    • pp.352-356
    • /
    • 2011
  • The detection of biomarkers is an important issue for disease diagnosis. However, many systems are not suitable to detect the biomarker itself directly. For direct detection of biomarker proteins in human serum, a new affinity-capture method using aptamers combined with the mass spectrometry was suggested. Since signals from protein samples cannot be amplified, modified chromatin immunoprecipitation (ChIP) and subsequent cross-linking with formaldehyde between aptamers and target proteins were used not to lose the captured target proteins, which allowed us to perform a harsh washing step to remove the non-specifically bound proteins. As a model system, a thrombin aptamer was used as a bait and thrombin as a target protein. Using our modified ChIP and affinity-capture method, non-specific binding proteins on the beads decreased significantly, suggesting that our new method is efficient and can be applied to developing diagnosis systems for various biomarkers.

Cell Adhesion and Growth on Nanostructured Surface

  • Yoon, Seo Young;Park, Yi-Seul;Choi, Sung-Eun;Jung, Da Hee;Lee, Jin Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.93-93
    • /
    • 2013
  • To make the rationale design of interface between cell and artificial surface, many studies have been controlled influencing cue which can typically be divided into two central categories: chemical cues based on modification surface chemical properties containing attractive/repulsive molecules, and physical cues that may include applied tension/stress, electrical polarization, magnetic field, and topography. Recently, researches have been focused on physical cue, especially topography. The surface topography may influence cellular responses for example, cell adhesion, cell morphology and gene expression. However, there were few systematic studies about these nanotopographical effects on neuronal developments in a feature size-dependent manner. Herein, we report a nanoscale-resolved study of nanotopographical effects on cellular adhesion and growth. In this study, we use substrates with packed glass beads by rubbing method for generating highly periodic nanotopographies with various sizes. We found that acceleration of neuritogenesis appeared only on the beads larger than 200 nm in diameter, and observed that filopodial thickness was comparable with this scale. This study is expected to be essential to elucidate the nanotopographical effect on cellular adhesion and growth.

  • PDF

Automatic Control System Design and Implementation for a Miniaturized DNA Extraction System using Magnetic Beads (자성 비드를 이용한 소형 유전자 추출기의 자동제어 시스템의 설계 및 구현)

  • Kim, S.;Kim, J.D.;Kim, H.C.;Kim, J.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.311-317
    • /
    • 2009
  • An automatic control system is proposed and implemented for a miniaturized DNA extraction system using magnetic bead. A host-local system is employed for the accommodation of the graphical user interface and the basic control function. The functional partitioning into the local and the host system is discussed. The control functions are classified and formalized for the flexible control scenario, which is the input of the proposed system. As the proposed scenario is consists of the sequence of the user-centric actions, the user goal can be easily programmed and modified. The DNA extraction performance of the implemented system was compared with the existing silica-membrane-based method, resulting in the comparable concentration and purity of the extracted DNA. The proposed system is currently being utilized for the development of the DNA extraction system only changing scenario, without any alteration of the system.

Fabrication and Characteristics of a Highly Sensitive GMR-SV Biosensor for Detecting of Micron Magnetic Beads (미크론 자성비드 검출용 바이오센서에 대한 고감도 GMR-SV 소자의 제작과 특성 연구)

  • Choi, Jong-Gu;Lee, Sang-Suk;Park, Young-Seok
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.5
    • /
    • pp.173-177
    • /
    • 2012
  • The multilayer structure of glass/Ta(5.8 nm)/NiFe(5 nm)/Cu(t nm)/NiFe(3 nm)/FeMn(12 nm)/Ta(5.8 nm) as typical GMR-SV (giant magnetoresistance-spin valve) films is prepared by ion beam sputtering deposition (IBD). The coercivity and magnetoresiatance ratio are increased and decreased for the decrease of Cu thickness when the thickness of nonmagnetic Cu layer from is varied 2.2 nm to 3.0 nm. It means that the decrease of non-magntic layer is effected to the interlayer exchange coupling of pinned layer and the spin configuration array of free layer. For experiment of detecting and dropping of magnetic beads we used the GMR-SV sensor with glass/Ta/NiFe/Cu/NiFe/FeMn/Ta structure. From the comparison of before and after for the dropping status of magnetic bead, the variations of MR ratio, $H_{ex}$, and $H_c$ are showed 0.9 %, 3 Oe, and 2 Oe, respectively. The fabrication of GMR-SV sensor was included in the process of film deposition, photo-lithography, ion milling, and MR measurement. Further, GMR-SV device can be easily integrated so that detecting biosensor on a single chip becomes possible.

Preconcentration and Determination of Trace Copper(II) and Lead(II) in Aqueous Solutions by Adsorption on Ca-Alginate Bead (알긴산칼슘 비드 상 흡착에 의한 흔적량 구리(II)와 납(II)의 동시 농축 및 정량)

  • Choi, Jong-Moon;Choi, Sun-Do
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.590-598
    • /
    • 2004
  • The preconcentration and determination of trace Cu(II) and Pb(II) on calcium alginate beads in aqueous solution were studied. A calcium alginate beads were prepared by adding an alginic acid to sample solution contained Ca(II). Some following conditions were optimized: the pH of sample solution, amount of alginic acid, and stirring time for effective adsorption; the type and concentration of acid, and sonication time in an ultrasonic vibrator for the perfect de-sorption. A sample solution was prepared with Cu(II) and Pb(II) in DI water. And Ca(II) and ethanol was added into the sample solution. The pH of the final sample solution was controlled with buffer solution. The alginic acid were dispersed in the sample solution by a magnetic stirrer. This mixture was stored in room temperature for 30 min to form a calcium alginate. After the beads were filtered and washed on a membrane filter, the analytes were redissolved from the beads by an ultrasonic vibration of 10 minutes in 1.0M $HNO_3$ solution. The effect of diverse ions on the adsorption of analytes were studied. This procedure was applied for the analysis of two real samples. The recoveries in spiked samples were $90.4{\sim}104.3%$ for analytes.

Detection of Norovirus in Contaminated Ham by Reverse Transcriptase-PCR and Nested PCR

  • Kim, Seok-Ryel;Kim, Du-Woon;Kwon, Ki-Sung;Hwang, In-Gyun;Oh, Myung-Joo
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.651-654
    • /
    • 2008
  • In order to enhance the efficacy of norovirus detection by reverse transcriptase-polymerase chain reaction (RT-PCR) and nested PCR, this study developed a norovirus mRNA concentration method using poly oligo dT-conjugated magnetic beads. An efficient norovirus detection protocol was performed on commercial ham using 2 viral elution buffers (glycine buffer and Tris beef extract buffer) and 2 concentration solutions [polyethylene glycol (PEG) and zirconium hydroxide]. The different approaches were verified by RT-PCR and nested PCR. This method was performed on ham in less than 8 hr by artificial inoculation of serial dilutions of the virus ranging from 1,000 to 1 RT-PCR unit/mL. The viral extraction and concentration method had 10-fold higher sensitivity using the combination of Tris beef extract buffer and PEG as compared to glycine buffer and zirconium hydroxide. This method proved that RT-PCR and nested PCR have the sensitive ability to detect norovirus in commercial ham, in that norovirus was successfully detected in artificially contaminated samples at a detection level as low as 1-10 RT-PCR unit/mL. Overall, such a detection limit suggests this protocol is both quick and efficient in terms of its potential use for detecting norovirus in meat products.

Direct Detection of Escherichia coli, Staphylococcus aureus, and Salmonella spp. in Animal-derived Foods Using a Magnetic Bead-based Immunoassay

  • Kim, Jong-Hui;Yoo, Jae Gyu;Ham, Jun-Sang;Oh, Mi-Hwa
    • Food Science of Animal Resources
    • /
    • v.38 no.4
    • /
    • pp.727-736
    • /
    • 2018
  • In this study, an immuno-magnetic bead (IMB)-based assay was developed to simultaneously detect Escherichia coli, Staphylococcus aureus, and Salmonella spp. and was tested in four animal-derived foods: beef, ham, egg, and ricotta cheese. The IMB-based assay exhibited good specificity by binding to five E. coli serotypes [capture efficiency (CE) average (avg.) 90.4%], five S. aureus strains (CE avg. 91.4%), and five Salmonella serotypes (CE avg. 95.4%) but not binding to non-target bacteria (CE<10%). Furthermore, the assay detected all three pathogens with a detection limit of 10 CFU/g without the need for enrichment or additional platforms. Since the results demonstrated that the IMB-based assay can effectively separate and enrich target bacteria from a variety of animal-derived food matrixes, the assay exhibits good specificity for potential use in providing rapid, immunological, presumptive identification of pathogenic bacteria.

Distribution of Magnetic Field Depending on the Current in the μ-turn Coil to Capture Red Blood Cells (적혈구 포획용 미크론 크기 코일에 흐르는 전류의 크기에 따른 자기장 분포 특성)

  • Lee, Won-Hyung;Chung, Hyun-Jun;Kim, Nu-Ri;Park, Ji-Soo;Lee, Sang-Suk;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.5
    • /
    • pp.162-168
    • /
    • 2015
  • The ${\mu}$-turn coil having a width of ${\mu}m$ on the GMR-SV (giant magnetoresistance-spin valve) device based on the antiferromagnetic IrMn layer was fabricated by using the optical lithography process. In the case of GMR-SV film and GMR-SV device, the magnetoresistance ratios and the magnetic sensitivities are 4.4%, 2.0%/Oe and 1.6 %, 0.1%/Oe, respectively. In the y-z plane the distribution of magnetic field of GMR-SV device and $10{\mu}$-turns coil which put under the several magnetic bead(MB)s with a diameter of $1{\mu}m$ attached to RBC (red blood cell) was analyzed by the computer simulation using the finite element method. When the AC currents of 20 kHz from 0.1 mA to 10.0 mA flow to the 10 turns ${\mu}$-coil, the magnetic field at the position of $z=0{\mu}m$ at the center of coil was calculated from $30.1{\mu}T$ to $3060{\mu}T$ in proportion to the current. The magnetic field at the position of $z=10{\mu}m$ was decreased to one-sixth of that of $z=0{\mu}m$. It was confirmed that the $10{\mu}$-turn coil having enough magnitude of magnetic field for the capture of RBC is possible to use as a biosensor for the detection of magnetic beads attached to RBC.

Synthesis of $TiO_2-Fe_2O_3$ Magnetic Photocatalyst Nanocomposite Powder (자성 광촉매용 $TiO_2-Fe_2O_3$나노복합분말의 합성)

  • 이창우;김순길;이재성
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.103-103
    • /
    • 2003
  • 대기나 물에 용해된 여러 가지 유해한 유기물을 분해하기 위한 방안으로서 다양한 광촉매 재료를 이용하려는 시도가 진행되고 있다. 하지만 광촉매 반응은, 현탁액 내에서 submicrometer 크기를 갖는 반도체재료에서 발생하므로 처리된 폐수로부터 촉매를 제거해야 하는 정제공정 (downstream process)이 필요하며, 이는 경제적인 측면에서 큰 경비를 요구하게 된다. 이를 해결 하기 위하여, 가장 우수한 광촉매 재료로 평가받는 TiO$_2$를 glass beads, sands, silica gel등의 물질에 고정시키거나, TiO$_2$를 자성 입자에 코팅시킨 형태인, 자성 광촉매입자를 응용하려는 연구가 최근 활발하게 진행되고 있다. 따라서 본 연구에서는 광촉매의 고정화와 재활용 효율을 향상시키기 위하여 TiO$_2$ 나노입자를 y-Fe$_2$O$_3$ 나노입자의 표면에 코팅하여 나노입자의 큰 비표면적을 활용하고 미세구조를 제어하여 입자간의 고정특성과 자기적 특성의 제어기술을 확립하고자 하였다.

  • PDF