• 제목/요약/키워드: machined

검색결과 1,237건 처리시간 0.027초

상악동 거상술을 동반한 상악구치부에 식립된 임플란트 생존율에 대한 후향적 연구 (The retrospective study of survival rate of implants with maxillary sinus floor elevation)

  • 김범진;이재훈
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권2호
    • /
    • pp.108-118
    • /
    • 2010
  • Introduction: Maxillary posterior region, compared to the mandible or maxillary anterior region, has a thin cortical bone layer and is largely composed of cancellous bone, and therefore, it is often difficult to achieve primary stability. In such cases, sinus elevation with bone graft is necessary. Materials and Methods: In this research, 121 patients who had implant placement after bone graft were subjected to a follow-up study of 5 years from the moment of the initial surgery. The total survival rate, 5-year cumulative survival rate and the influence of the following factors on implant survival were evaluated; the condition of the patient (sex, age, general body condition), the site of implant placement, diameter and length of the implant, sinus elevation technique, closure method for osseous window, type of prosthesis and opposing teeth. Results: 1. The 5-year cumulative survival rate of total implants was 90.5%, there was no significant difference between sex, age, the site of implant placement, diameter and length of the implant, sinus elevation technique, and the type of opposing teeth. 2. Patients with diabetes mellitus < osteoporosis and smooth-surfaced machined group < hydroxyapatite (HA)-treated group and homogenous demineralized freeze dried allogenic bone (DFDB) bone graft only group had significantly lower survival rate. 3. With less than 4 mm of residual alveolar ridge height, lateral approach without closing the osseous window resulted in a significantly lower survival rate. 4. Restoration of a single implant showed a significantly lower survival rate, compared to cases where the superstructure was joined with several implants in the area. Conclusion: Patients with diabetes or osteoporosis need longer period of time for osseointegration compared to the normal, and the dentists must be prudent when choosing a surface treatment type and the bone graft material. Also, as the vertical dimension of the residual alveolar ridge can influence the result, staged implant placement should be considered when it seems difficult for the implant to gain primary stability from the residual bone with less than 4 mm of vertical dimension. It is recommended to obdurate the bone window and that the superstructure be connected with several impants in the peripheral area.

비파괴법에 의한 압력용기 강 다층용접부의 균열선단에서 소성변형 역성장거동 평가에 관한 연구 (Study on Evaluation of Plastic Deformation Zone at Crack Tip for the Multi-Passed Weld Region of the Pressure Vessel Steel Using Nondestructive Method)

  • 나의균;이상근
    • 비파괴검사학회지
    • /
    • 제29권5호
    • /
    • pp.473-478
    • /
    • 2009
  • 본 연구에서는 비파괴법을 이용하여 압력용기 강 다층용접부에서 채취한 표준 샤르피 시험편의 균열선단에서 형성되는 소성변형 거동을 평가하였다. 모재, 후열처리재 및 용접재를 대상으로 시험편에 기계적인 노치를 가공한 후 예균열(pre-crack)을 낸 다음 4점 굽힘실험과 음향방출(acoustic emission: AE)실험을 동시에 실시하였다. 균열선단은 용접재외 후열처리재의 경우 용융선 근처에 위치하도록 하였다. 하중이 가해짐에 따라 균열선단에서 형성되는 소성영역의 크기는 응력확대계수를 이용하여 구했으며, 각 시험편에 대한 소성역의 크기와 음향방출 특성과의 관계는 축적된 AE 에너지 관점에서 고찰하였다. 시험편에 관계없이 탄성역역에서는 거의 AE신호가 감지되지 않았으며, 대부분의 AE신호는 소성변형 과정에서 발생하였다. 또한, 용접재가 모재와 후열처리재에 비해 AE신호가 훨씬 많이 발생하였다. 모재와 후열처리재 및 용접재의 균열선단에서 소성영역 크기와 축적된 AE에너지와의 관계는 현저히 다르게 나타났으며, 용접재의 AE counts는 모재와 후열처리재에 비해 많이 발생하였다.

고속 자율 무인잠수정 적용을 위한 MEMS 기술기반 자세 측정 장치 개발 (Development of Attitude Heading Reference System based on MEMS for High Speed Autonomous Underwater Vehicle)

  • 황아롬;안남현;윤선일
    • 해양환경안전학회지
    • /
    • 제19권6호
    • /
    • pp.666-673
    • /
    • 2013
  • 본 연구는 빠른 운항 속도와 짧은 운용 시간을 요구하는 임무에 활용될 저가 소형 자율 무인잠수정에 고가 대형 관성 측정 장치를 대신하여 사용할 수 있는 저가 소형 자세 측정 장치 개발 및 성능 검증을 수행하였다. 저가 소형 자세 측정 장치 개발을 위해서 MEMS 기술을 적용한 gyro, accelerometer 및 magnetometer 채택하여 MEMS 기반 하드웨어를 제작하였으며, 좌표 변환 공식과 칼만 필터를 적용하여 자세 계산 알고리즘을 구현하였다. 또한 개발된 MEMS 기반 자세 측정 장치에 대한 기본 성능 검증을 위한 지자기센서 검증 시험, 정적 자세 시험, 차량 시험, 운동 모사 장치 시험을 수행하였으며, 각각 시험 결과를 제시하였다. 지자기센서 검증 시험 결과 외부 자기장 보정을 통하면 개발된 MEMS 기반 자세 측정 장치의 측정 결과가 외부 자기장에 강인함을 확인하였으며, 정적 자세 시험 및 차량 시험을 통하여 자세 변화가 크지 않는 환경에서 자세 측정 오차가 $0.5^{\circ}/hr$ 임을 확인하였다. 운동 모사 장치 시험을 통하여 5분 내외 자세 변화가 큰 운동 중에도 자세 측정 오차가 발산하지 않고 $1^{\circ}/hr$ 이내임을 확인하였다. 상기 시험 결과로부터 개발된 MEMS 기반 자세 측정 장치가 목표 성능인 $1^{\circ}/hr$이내 roll, pitch, yaw 오차를 보여주고 있음 확인하였으며, 이로부터 20분 내외 운용 시간 동안 정확한 자세 정보 제공 가능성을 확인할 수 있었다.

3D 구조 알루미늄 판재의 점진판재성형 특성 평가 (제2보) (Evaluation of incremental sheet forming characteristics for 3D-structured aluminum sheet - part 2)

  • 김영석;;안대철
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.1585-1593
    • /
    • 2015
  • 3차원 구조 알루미늄 판재(엠보싱 판재)는 표면적이 증가되어 방열효과가 뛰어나고 가공경화에 의해 굽힘강성 증가효과가 있으므로 자동차 열차단 부품에 널리 사용된다. 그러나 엠보싱 판재는 평판의 판재와 비교하면 기계적 특성이 상이하고 또한 3차원 형상으로 인해 프레스 가공에 있어서 많은 제약이 따른다. 본 연구에서는 프레스 가공공정을 대신하여 최근 신제품의 디자인 검증과 시생산에 널리 채용되고 있는 점진성형공정을 대상으로 엠보싱된 판재의 성형특성을 평가하였다. 본 연구에서 채용한 공구형상을 이용한 사각 원뿔의 점진성형 결과, 엠보싱된 판재의 경우가 평판의 경우보다 더 큰 기울기를 갖는 사각 원뿔을 파단없이 성형할 수 있음을 보였다. 이는 점진성형공정에서 CNC 공구의 이동경로(tool path)하에서 공구가 엠보싱 판재의 산과 골을 눌러 복원시키면서 재료의 소성변형을 증가시키기 때문이다. 또한 공구의 이동경로가 내향 경로보다 외향 경로인 경우가 보다 큰 기울기의 제품을 성형할 수 있지만 스프링 백의 발생으로 제품의 표면품질은 열세에 있음을 보였다.

구내고정원을 이용한 교정 치료중 miniscrew 탈락에 관한 연구 (A CLINICAL STUDY ON SKELETAL ANCHORAGE SYSTEM USING MINISCREW)

  • 우순섭;정순태;허영성;황경균;유임학;심광섭
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권2호
    • /
    • pp.102-107
    • /
    • 2003
  • At orthodontic treatment, we have made every effort to get rigid anchorage which is not stirred when teeth move. As a result, the miniscrew that is rigid anchorage was invented recently, and now it is used widely. Concerning the advantage of miniscrew, it is reduced dependence of extraoral anchorage and it shortens treatment time for rapid tooth movement. In contrast, the defect of miniscrew is falling off it resulted from increasing of the mobility. So the purpose of this research is to be of help to prognose clinical use of miniscrew, which is inserted for intraoral anchorage, by investigating and comparing the failure rate of miniscrew for loading time. This study researches the failure rate of miniscrew for teeth movement at the orthodontic treatment. The failure rate of miniscrew in mid course, after inserting 147 miniscrews in 51 patients, is 13%(20/147). It showed no statistically significant differences as compared man with woman, maxilla with mandible, double-head with uni-head miniscrew, and drilling and non-drilling before inserting the miniscrew. In comparison below twenties with over twenties and the times that we give load to miniscrew, it produced that the failure rate of miniscrew is 9.7% higher in the case of below the twenties than over the twenties. Also, the failure rate of loading immediately is 10.8% higher than loading after 7 days. According to using driver for the insertion of miniscrew, the failure rate of miniscrew is higher in the case of using machined driver than in the case of using hand driver when the level of significance is 95%. According to the research, we can suppose that the failure rate has no concern with using miniscrew on man or woman, maxilla or mandible, the shape of head, and drilling or non-drilling before insertion of miniscrew. Therefore, we can choose eclectic miniscrew as demands. In addition, we must notify the patient, below twenties, to be possibility of high failure rate. And It is strongly recommended to give load after $1{\sim}2$ weeks for healing of the insertion area.

임플란트의 표면처리 유형에 따른 골 치유 양상 (Bone Healing around Screw - shaped Titanium Implants with Three Different Surface Topographies)

  • 고영한;김영준;정현주
    • Journal of Periodontal and Implant Science
    • /
    • 제31권1호
    • /
    • pp.41-57
    • /
    • 2001
  • It is well known that the apposition of bone at implant surface would be influenced by the microstructure of titanium implants. The purpose of this study was to compare bone healing around the screw-shaped titanium implant with three different surface topographies in the canine mandibles by histological and biomechanical evaluation. All mandibular premolars of six mongrel dogs were extracted and implants were placed one month later. The pure titanium implants had different surface topographies: smooth and machined ($Steri-OSS^{(R)}$: Group II); sandblasted and acid-etched ($ITI^{(R)}$, SLA: Group III) surface. The fluorescent dyes were injected on the 2nd (calcein), 4th (oxytetracycline HCI) and 12th (alizarin red) weeks of healing. Dogs were sacrificed at 4 and 12 weeks after implantation. The decalcified and undecalcified specimens were prepared for histological and histo-metrical evaluation of implant-bone contact. Some specimens at 12 weeks after implantation were used for removal torque testing. Histologically, direct bone apposition to implant surface was found in all of the treated groups. More mature and dense bone was observed at the implant-bone interface at 12 weeks than that at 4 weeks after implantation. Under the fluorescent microscope, thick regular green fluorescent lines which mean early bone apposition were observed at the implant-bone interface in Group III, while yellow and red fluorescent areas were found at the implant-bone interface in Group I and II. The average implant-bone contact ratios at 4 weeks of healing were 54.3% in Group I, 57.7% in Group II and 66.2% in Group III. In Group I, implant-bone contact ratio was significantly lower than Group II and III(p<0.05). The average implant-to-bone contact ratios at 12 weeks after implantation were 64.3% in Group I, 66.7% in Group II and 71.2% in Group III. There was no significant difference among the three groups. In Group I and II, the implant-bone contact ratio at 12 weeks increased significantly in comparison to ratio at 4 weeks(p<0.05). The removal torque values at 12 weeks after implantation were 90.9 Ncm in Group I, 81.6 Ncm in Group II and 77.1 Ncm in Group III, which were significantly different(p<0.05). These results suggest that bone healing begin earlier and be better around the surface-treated implants compared to the smooth surface implants. The sandblasted and acid-etched implants showed the most favorable bone response among the three groups during the early healing stage and could reduce the waiting period prior to implant loading.

  • PDF

열간가압소결법으로 제조한 탄화규소의 균열자기치유 특성 (Characterization of crack self-healing of silicon carbide by hot press sintering)

  • 김성훈;김경훈;도환수;박주석;김경자;심광보
    • 한국결정성장학회지
    • /
    • 제26권2호
    • /
    • pp.62-66
    • /
    • 2016
  • 본 연구에서는 열간가압소결법으로 SiC를 소결하여 균열자기치유 특성을 분석하였다. SiC는 $Al_2O_3$$Y_2O_3$를 소결조제로 $1950^{\circ}C$, 50 MPa, 아르곤(Ar) 분위기에서 소결하였다. 소결된 시편을 $3{\times}4{\times}40mm$, 절단 및 가공하고, Vickers 경도기를 이용하여 49.6 N으로 예비균열을 생성하였다. $1200{\sim}1400^{\circ}C$, 1~10시간 산화분위기에서 열처리한 후 XRD, SEM, 3점 굽힘강도를 측정하였다. $1300^{\circ}C$ 1시간에서 741 MPa, 5시간에서 770 MPa로 가장 우수한 균열자기치유 효과를 나타내는 것으로 분석되었다.

위팔뼈 의료용 디지털 영상 및 통신 표준 영상을 이용한 5축 가공기술의 융합적 연구 (A Convergence Study on the 5-axis Machining Technology using the DICOM Image of the Humerus Bone)

  • 윤재호;지태정;윤준;김형균
    • 한국융합학회논문지
    • /
    • 제8권11호
    • /
    • pp.115-121
    • /
    • 2017
  • 의료용 디지털 영상 및 통신 표준과 5축 가공기술의 융합적 연구를 통하여 맞춤형 인공관절의 기초적 지식을 얻고자 하였다. 연구방법으로 의료영상의 위팔뼈에 대해 3차원 모델링을 생성하고 케미컬우드 소재로 형상을 가공하여 해부학적 특징과 모델링 가공 연산시간을 비교하였다. 그 결과 스테레오리소그래피 모델링이 아이제스 모델링에 비해 중삭 2배, 정삭 10배 정도로 시간이 많이 소요되었다. 5축 가공된 위팔뼈는 해부목, 큰돌기, 작은돌기, 결절사이 고랑의 해부학적 구조가 3차원 의료영상과 동일한 특징으로 나타났다. 이와 같이 위팔뼈의 외과목 언더컷 등 다양한 형태의 구조가 5축으로 가공되는 융합적 가공 기술들은 인체의 정밀한 모형을 추구하는 맞춤형 관절 제작 시 향후 적용 가능성이 높음을 알 수 있었다.

티타늄과 금합금의 레이저 용접부의 인장강도 (TENSILE STRENGTH OF LASER WELDED-TITANIUM AND GOLD ALLOYS)

  • 송윤관;송광엽;하일수
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.200-213
    • /
    • 2000
  • Lasers have given dentistry a new rapid, economic, and accurate technique for metal joining. Although laser welding has been recommended as an accurate technique, there are some limitations with this technique. For example, the two joining surfaces must have a tight-fitting contact, which may be difficult to achieve in some situations. The tensile samples used for this study were made from a custom-made pure titanium and type III gold alloy plates. 27 of 33 specimens were sectioned perpendicular to their long axis with a carborundum disk and water coolant. Six specimens remained and served as the control group. A group of 6 specimens was posed as butt joints in custom parallel positioning device with a feeler gauge at each of three gaps : 0.00, 0.25. and 0.50mm. All specimens were then machined to produce a uniform cross-sectional dimension, none of the specimens was subjected to any subsequent form of heat treatment. Scanning electron microscopy was performed on representative tested specimens at fractured surfaces in both the parent metal and the weld. Vickers hardness was measured at the center of the welds with a micropenetrometer using a force of 300gm for 15 seconds. Measurement was made at approximately $200{\mu}m\;and\;500{\mu}m$ deep from each surface. One-way analysis of variance (ANOVA) and Scheffe's test was calculated to detect differences between groups. The purpose of this study is to compare the strength and properties of the joint achieved at various butt Joint gaps by the laser welding of type III gold alloy and pure titanium tensile specimens in an argon atmosphere. The results of this study were as follows : 1. When indexing and welding pure titanium, there was no decrease in ultimate tensile strength as compared with the unsectioned alloys for indexing gaps of 0.00 to 0.50mm, although with increasing gap size may come increased distortion (p>0.05). 2. When indexing and welding type III gold alloy, there were significant differences in ultimate tensile strength among groups with weld gaps of 0.00mm, 0.25 and 0.50mm, and the control group. Group with butt contact without weld gap demonstrated a significant higher ultimate tensile strength than groups with weld gaps of 0.25 and 0.50mm (p<0.05). 3. When indexing and welding the different metal combination of type III gold alloy and pure titanium, there were significant differences in ultimate tensile strength between groups with weld gaps of 0.00, 0.25, and 0.50mm. However, the mechanical properties of the welded joint would become too brittle to be acceptable clinically (p<0.05). 4. The presence of large pores in the laser welded joint appears to be the most important factor in controlling the tensile strength of the weld in both pure titanium and type III gold alloy.

  • PDF

치과 CAD/CAM용 Nano Hybrid Ceranic 소재를 이용한 심미 치과보철물의 제작 (A Making of Aesthetic Dental restorations with Nano Hybrid Ceramic material by CAD/CAM System)

  • 최범진
    • 대한심미치과학회지
    • /
    • 제25권2호
    • /
    • pp.98-108
    • /
    • 2016
  • 전통적인 Metal-ceramic 보철 제작 방식으로부터 All-ceramic 보철에 이르기까지 최근 신소재 개발에 영향을 주는 가장 큰 요인은 심미적인 욕구일 것이다. 우리가 사용하는 각각의 치과용 수복 재료는 재료 별로 강도, 인성, 기계 가공의 효율성 및 사용에 필요한 다양한 과정을 기반으로 임상에서 다양하게 사용되고 있다. 예를 들어 Glass ceramic과 같은 단일 소재의 경우 약한 물성을 고려하여 주로 싱글 크라운과 같은 간단한 보철에 사용하고 있으며 상대적으로 높은 파괴 인성을 가진 지르코니아 재료의 경우 싱글 크라운은 물론 브릿지의 제작에도 널리 사용하고 있다. 하지만 지르코니아 재료는 제작 과정에서 긴 Sintering 시간을 필요로 하므로 Chair side에서 빠른 보철물 제작에 쉽지 않은 부분이 있으며 주로 Lab. side에서 사용하고 있다. CAD / CAM 시스템을 이용하여 보철물을 제작하는 용도로 개발 된 Hybrid ceramic 소재는 Resin Nano Hybrid Ceramic이라고도 하며, 개선 된 물성을 포함한 나노 세라믹 요소를 기반으로 하고 있다. 이러한 특징들은 심미적이며 기능적인 보철물의 제작이 용이한 과정과 결과를 보이고 있으며 동시에 향상된 내구성을 바탕으로 보철물의 제작 과정에 유리한 조건들을 가지고 있다. 새로운 Nano Hybrid Ceramic 재료는 Composite Resin과 Glass ceramic과 같은 단일 소재들이 가진 장점들을 이용하여 술자들의 요구사항을 바탕으로 오랜 연구를 통해 개발된 치과 수복 아이템이며 Nano ceramic filler가 혼합된 구조로 되어있어 치과 수복용 복합소재로서 널리 사용하고 있다. 또한 Nano Hybrid Ceramic소재는 Composite resin의 가공 과정에서 쉽게 파절되지 않는 개선된 물성과 Glass ceramic이 가진 심미성 동시에 포함하고 있는 것이 특징이다. 따라서 Chair side와 Lab. side에서 CAD/CAM 시스템을 이용하여 보철물을 제작할 때 임상적용이 쉽고 유용한 장점을 가지고 있어 추가적인 연구가 필요하다.