• 제목/요약/키워드: machine

검색결과 24,287건 처리시간 0.053초

정상교합자와 3급 부정교합자에서 구륜근과 턱끝근의 활성과 안면골격 사이의 상관성에 관한 연구 (CORRELATIONS BETWEEN ORBICULARIS ORIS AND MENTALIS MUSCLE ACTIVITY AND CRANIOFACIAL MORPHOLOGY IN NORMAL OCCLUSION AND CLASS III MALOCCLUSION)

  • 장춘실;이기수
    • 대한치과교정학회지
    • /
    • 제22권1호
    • /
    • pp.253-271
    • /
    • 1992
  • The purpose of this study was to investigate the difference of EMG activity of the Orbicularis oris and Mentalis muscle between normal occlusion and class III malocclusion group during various lip position and to find out whether any correlations exist between the muscular activity and craniofacial morphology. In this study, 50 subjects with a mean age of 22.9 Years (range 20.0-26.0) were investigated (25 subjects were normal occlusion, and 25 subjects were class III malocclusion). EMG data were recorded from the Orbicularis oris and Mentalis muscle during rest lip posture, lip position at maximum biting, lip position at maximum sealing effort, lip position at chewing, swallowing and phonation with the Medelec MS-25 electromyographic machine. Lateral cephalometric radiographs was taken with the mandible in intercuspal position on all subjects. All data were recorded and statistically processed. The findings of this study can be summerized as follows: 1. In normal occlusion, the maximal mean amplitude of upper lip during the lip position at chewing was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 2. In Class III malocclusion, the maximal mean amplitude of upper lip during the lip position at chewing, swallowing and phonation was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 3. Compare to normal occlusion, the Class III malocclusion was showed low maximal mean amplitude of upper lip during rest lip posture and the lip position at swallowing of saliva, and showed great maximal mean amplitude of lower lip and meantalis muscle during the lip position at chewing and phonation. 4. In normal occlusion, the maximal mean amplitude of upper lip during various lip position was not correlated with the length and thickness of upper lip, but the maximal mean amplitude of lower lip during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip. 5. In Class III malocclusion, the maximal mean amplitude of upper lip during rest lip posture was negatively correlated with the thickness of upper lip, and the maximal mean amplitude of lower lip and mentalis muscle during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not correlated with the cephalometric measurements of soft tissue. 6. The correlation between the maximal mean amplitude of orbicularis oris and mentalis muscle and cephalometric measurements of incisors was not nearly present. 7. In normal occlusion, the maximal mean amplitude of lower lip and mentalis muscle during the lip position at maximum biting was negatively correlated with the angle between palatal plane and mandibular plane. In Class III malocclusion, the maximal mean amplitude of upper lip, lower lip and mentalis muscle during function was negatively correlated with the length of maxilla, the maximal mean amplitude of upper lip and lower lip during function was negatively correlated with the SNA and SNPo, and the maximal mean amplitude of lower lip during the lip position at chewing was negatively correlated with the ANB.

  • PDF

구치부용 복합 레진 가열시 물리적 성질의 변화에 관한 실험적 연구 (THE EFFECT OF TEMPERATURE CHANGES ON THE PHYSICAL PROPERTIES OF POSTERIOR COMPOSITE RESINS)

  • 박연홍;민병순;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.41-56
    • /
    • 1989
  • The purpose of this study was to examine the effect of temperature dependence of the behavior on the physical properties of posterior composite resins. Three light cure posterior composite resins (Heliomolar, Litefil-P, and P-50) and one chemical cure posterior composite resin (Bisfil-II) were used as experimental materials. Composite resin was placed in a cylindrical brass mold (2.5 mm high and 6.5 mm inside diameter) that was rested on a glass plate. Another flat glass was placed on top of the mold, and the plate was tightly clamped together. After the mold had been filled with the light cure composite material, the top surface was cured for 30 seconds with a light source. Chemical cure resin specimens were made in the same manner as above. Three hundreds and twenty composite resin specimens were constructed from the four composite materials. One hundred and sixty specimens of them were placed in a heater at $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$, $125^{\circ}C$, $150^{\circ}C$, $175^{\circ}C$ and $200^{\circ}C$ for 5 minutes or 10 minutes respectively before compressive strengths were measured. Another one hundred and sixty specimens were tested for the diametral tensile strengths in the same way as above. They were randomly divided into eight groups according to the mode of heating methods as follows and stored in distilled water at $37^{\circ}C$ for 24 hours. Group $37^{\circ}C$ - specimens were stored at $37^{\circ}C$ in distilled water for 24 hours. Group $50^{\circ}C$ - specimens were heated at $50^{\circ}C$ after curing. Group $75^{\circ}C$ - specimens were heated at $75^{\circ}C$ after curing. Group $100^{\circ}C$ - specimens were heated at $100^{\circ}C$ after curing. Group $125^{\circ}C$ - specimens were heated at $125^{\circ}C$ after curing. Group $150^{\circ}C$ - specimens were heated at $150^{\circ}C$ after curing. Group $175^{\circ}C$ - specimens were heated at $175^{\circ}C$ after curing. Group $200^{\circ}C$ - specimens were heated at $200^{\circ}C$ after curing. Twenty specimens of each of four composite resins were respectively made by insertion of materials into same mold for examining the dimensional changes between before and after heating. The final eighty specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before testing the dimensional changes. Compressive and diametral tensile strengths were measured crosshead speed 1mm/minute and 500Kg in full scale with a mechanical testing machine (DLC 500 Type, Shimadzu Co., Japan). Dimensional changes were determined by measuring the diametral changes of eighty specimens with micrometer (Mitutoyo Co., Japan). Results were as follows: 1. Diametral tensile strengths of specimens in all groups were increased with time heated compared with control group except for that in group $50^{\circ}C$ and the maximum diametral tensile strength was appeared in the specimen of Litefil-P heated for 10 minutes at $100^{\circ}C$. In heliomolar and P-50, it could be seen in the specimen heated for 10 minutes at $150^{\circ}C$, but in Bisfil-II, it could be found in the specimen heated for 5 minutes at $150^{\circ}C$. 2. Compressive strengths of specimens in all groups was tended to be also increased with time heated but that in group $50^{\circ}C$ and the maximum compressive strengths were showed in the same specimens conditioned as the diametral tensile strengths of four composite materials tested. 3. In Heliomolar, Litefil-P, and Bisfil-II, it was decreased in diameters of resin specimens between before heating and increased in diameters of resin specimens after storing in distilled water, but it was not in P-50. 4. There is little difference in diametral tensile strengths, compressive strengths, and dimensional changes followed by heating the resin specimens for 5 minutes and 10 minutes, but there is no statistical significances.

  • PDF

X-선(線) 조사(照射)가 Ehrlich 암세포(癌細胞)의 용적(容積), 단백양(蛋白量) 및 수종(數種) Sulfhydryl 기(基)에 미치는 영향(影響)에 관(關)하여 (Effect of X-Irradiation on the Levels of some Sulfhydryl Groups, Protein and Cell Volume of Ehrlich Ascites Tumour Cells)

  • 유춘식;주영은
    • The Korean Journal of Physiology
    • /
    • 제3권2호
    • /
    • pp.9-16
    • /
    • 1969
  • It is well known that a number of -SH and -SS containing substances afford a certain measure of protection against radiation effects in many biological systems, and it is conceivable that inherent -SH levels in Ehrlich ascites tumour (ELD)cells may be of decisive improtance with respect to the development of cellular radiation injury. So far, little effort has been directed to elucidate the changes in levels of different -SH and -SS groups in ELD cells when the tumour-bearing whole animal was subjected to the sublethal dose of X-irradiation. The present study was designed to bring some lights in the possible changes of and relationship between various sulfhydryl levels, such as P-SH, NP-SH and NP-SS, as well as the content of protein and cell volume of ELD cells, after subjecting the ELD mice to 1,200 r of X-irradiation. The animals used in this experiment were all mixed bred mice of $20{\sim}25\;gm$ in body weight (approximately 2 months old) irrespective of sex. 12 mice in one experiment were inoculated intraperitoneally with 0.2 ml of ascites tumour cells $(2{\times}10^6\;cells)$, and on the 7th day of the tumour growth, they were X-irradiated with 1,200 r, using the conventional X-ray machine under the following conditions: 200 Kv at 15 mA, 0.5 mm Cu filter, target-skin distance: 50 cm. Radiation dose was measured with the the Philip integrating dosimeter. At 24, 36, 48 and 60 hours after the X-irradiation, the mice were killed by cervical dislocation, and the tumours were taken out. Freshly withdrawn ascites tumours were placed in ice, and immediately the cell concentration was measured with the Coulter Cell Counter (Model B), and the hematocrit of the tumour cells were also determined. Cell volume was thus calculated by the cell concentration and hematocrit value. P-SH content of ELD cells was measured potentiometrically according to the method of Calcutt & Doxey, and NP-SH and NP-SS contents were measured spectrophotometrically by the method described by Ellman. Protein content of ELD cells was determined with the Folin phenol reagent by Lowry et al. Altogether, 48 experimental mice were used, and 12 mice with the only exception of X-irradiation were used as the control. Results obtained indicate that the contents of all the cellular sulfhydryl groups as well as cell volume and protein content of the ELD cells increase significantly as time progresses after the sub-lethal X-ray dose of 1,200 r was given and that all the increase is in a lineal fashion. The regression lines of the relative values, (i. e., taking each control value as 1) of all the values obtained, and the regression lines of cell volume, protein and NP-SH are identical, whereas those of NP-SS and P-SH appear to be widely seperated. However, the difference of those two lines (NP-SS & P-SH) were found to be not significant statistically (p>0.05). Therefore, it can be concluded from the above results that all the values examined increase in a lineal fashion with no statistically significant difference among them. Also, with the radiation dose of 1,200 r, the ELD cell becomes enlarged and swollen progressively up to 60 hours post-irradiation and it becomes more than two times of the original normal size at 60 hours after the irradiation, and up to this stage, it seems apparent that the cell division has been slow due to the X-irradiation applied in this experiment. It is well understandable that the contents of NP-SH, NP-SS, P-SH and protein of the ELD cells increase in parallel with the increase of the cell volume by the X-ray does used, but it also seems interesting to note that all the cellular substances tested show no appreciable difference in the pattern of increase.

  • PDF

복합세라믹 담체를 이용한 돈분 퇴비화 연구 (Composting of the Pig Manure Used with the Ceramic Biocarrier)

  • 황준영;이종은;장기운
    • 유기물자원화
    • /
    • 제11권2호
    • /
    • pp.110-116
    • /
    • 2003
  • 본 연구는 부숙촉진 미생물이 배양된 복합세라믹 담체를 처리하여 고속발효기를 통한 돈분 퇴비화 과정 중 퇴비 부숙도와 품질안정성을 분석하여 그 이용성과 효용성을 평가하기 위해 수행하였다. 각 처리구는 대조구(C), 미생물 처리구(M), 미생물 및 천연 제올라이트 처리구(M+Z). 미생물 및 합성 제올라이트 처리구(M+SZ), 미생물 및 복합세라믹 담체 처리구(M+CZ)등 5개의 처리구를 두고 실험을 실시하였다. 이에 대한 결과는 다음과 같았다. 온도 변화는 미생물제재 및 제올라이트의 첨가 유무와 종류에 상관없이 모든 처리구에서 유사한 온도변화를 보였으며, 미생물처리구가 대조구보다 약간 온도가 높은 결과를 나타났다. pH 변화는 대조구보다 모든 처리구에서 높게 나타났으며, M+CZ와 M+SZ 처리구에서 다소 높았다. 그리고 T-C, T-N 및 C/N율의 결과를 보면 총탄소의 변화는 M+CZ 처리구가 가장 감소폭이 큰 것으로 나타났으며, M+Z 처리구도 대조구와 미생물처리구보다 감소가 두드러졌다. 전질소는 각 처리구별로 1.4~1.8% 정도였으며, 처리구간의 큰 변화는 없었다. 또한 C/N비는 총탄소의 변화가 큰 M+CZ 처리구와 M+SZ 처리구에서 대조구와 미생물 처리구보다 다소 낮은 결과로 약 21.4~23.3의 결과를 보였다. 부숙도 평가를 위한 식물독성시험 결과 역시 M+CZ 처리구와 M+SZ 처리구에서 가장 높은 약 110 정도의 G.I 값을 나타내었다. 결론적으로 복합세라믹 담체를 이용한 돈분 퇴비화 과정중 퇴비의 이화학적 특성변화와 부숙 안정도의 측면에서 볼 때 그 효용성이 인정되었다고 판단된다.

  • PDF

ICT 중소기업 R&D의 스테레오타입에 대한 연구 : 한국의 사례를 중심으로 (A Study on the Stereotype of ICT SMEs' R&D: Empirical Evidence from Korea)

  • 전승표;최산;정재웅
    • 기술혁신학회지
    • /
    • 제20권2호
    • /
    • pp.334-367
    • /
    • 2017
  • 국내 ICT 산업은 글로벌 경쟁력을 갖추고 경제발전에 크게 이바지 해왔으며, 침체된 우리나라의 경제상황을 활성화할 수 있는 성장 동력으로 주목받고 있다. 이러한 ICT 산업을 국내외에서 다양한 모습으로 바라보고 있는데, 이 중에는 객관적인 근거가 부족한 고정 관념도 많다. 이런 특정 집단에 대해 많은 사람이 가지는 공통되고 고정된 견해가 스테레오타입인데, 스테레오타입은 항상 부정적인 것은 아니지만 우리의 의사결정에 큰 영향을 주기 때문에 간과할 수 없다. 따라서 본 연구는 ICT 산업에 대한 스테레오타입을 살펴보고 보다 객관적이고 상대적인 스테레오타입을 제공하고자 한다. 이를 위해, 본 연구는 3,300개 중소기업 설문을 토대로 의사결정나무 분석을 통해 국내 ICT 기업이 다른 기술 기업과 비교해서 가지는 특징을 도출했다. 기업일반, 기술개발 활동, 기술개발 조직과 인력 등 10가지 R&D 정책 주제에 대해서 291개 변수를 대상으로 분석했는데, 기계학습을 활용한 데이터마이닝의 한 가지 방법인 의사결정나무 분석을 활용해서 ICT 기업과 다른 기술 기업이 구분되는 변수를 찾고 그 특징을 통해 객관적인 ICT 기업의 스테레오타입을 제시했다. 이 연구의 결과로 제시된 ICT 기업의 스테레오타입에 따르면, 국내 ICT 기업을 위해서는 첫째 R&D 기획이나 판로개척을 지원할 수 있는 기술정책이 필요하며, 둘째 신제품이나 신규 분야 진출을 위한 R&D 지원정책이 강화되어야 하고, 셋째 기술개발 결과에 대한 보안과 지재권 관리를 위한 지원정책이 요구되며, 넷째 ICT 기업과 관련된 정부 R&D 지원 제도관련 행정 간소화가 요구되는 것으로 나타났다. 이 연구의 결과는 ICT 중소기업을 위한 기술정책 수립 집행 평가에 다양한 시사점을 제공할 수 있으며, 특히 ICT 중소기업을 위한 R&D 정책을 수립하는 정책당국자나 유관기관의 연구자에게 여러 가지 정책적 가이드를 제공해 줄 것으로 기대한다.

한반도 모자이크 영상의 토지피복분류 활용 가능성 탐색을 위한 비교 연구 (A Comparative Study on the Possibility of Land Cover Classification of the Mosaic Images on the Korean Peninsula)

  • 문지윤;이광재
    • 대한원격탐사학회지
    • /
    • 제35권6_4호
    • /
    • pp.1319-1326
    • /
    • 2019
  • 한국항공우주연구원은 지속적으로 증가하는 공공분야의 위성영상 수요에 대응하기 위해 정부 위성정보활용협의체를 운영하고 있으며, 사용자 편의성 증진 및 위성영상 활용 활성화를 위해 매년 한반도 모자이크 영상을 제작하여 제공하는 등 다양한 지원사업을 수행하고 있다. 특히 한반도 모자이크 영상의 활용도를 높이고 사용자가 손쉽게 분류 영상을 현업에 활용할 수 있도록 모자이크 영상을 분류 및 갱신하는 방안을 모색하고 자 하였다. 그러나 한반도 모자이크 영상은 영상 융합 및 컬러 밸런싱 등을 적용하기 때문에 분광정보, 즉 색상왜곡이 발생하고 R, G, B 밴드만 보유하고 있다는 한계점이 있기 때문에 모자이크 영상으로 만들어낸 분류 결과가 현업에서 활용될 수 있는 수준인지 확인 및 검증이 필요하다. 따라서 본 연구에서는 모자이크 영상으로 분류를 수행했을 때 그 결과물의 신뢰도를 KOMPSAT-3 영상과 비교하여 확인해보고자 하였다. 연구 결과, KOMPSAT-3 영상의 분류 정확도는 약 81~86%(전체 정확도 약 85%)로 나타난 반면, 모자이크 영상분류 결과의 정확도는 약 69~72%(전체 정확도 약 72%)로 다소 낮게 나타났다. 이러한 현상은 모자이크 영상을 생성하는 과정에서 영상 융합과 모자이크 과정을 거치며 본래의 분광정보가 왜곡되었을 뿐만 아니라, 컬러밴드인 R, G, B 세 가지의 밴드만 제공함에 따라 NDVI나 NDWI 정보를 실제 모자이크 영상이 아닌 KOMPSAT-3 영상에서 추출하였기 때문으로 해석된다. 비록 현재로서는 모자이크 영상으로 토지피복분류를 수행하여 사용자에게 배포하기에는 무리가 있을 것으로 판단되나, 추후 모자이크 영상을 제작할 때 분광정보 왜곡을 최소화할 수 있는 방법을 모색하고 R, G, B 밴드뿐만 아니라 NIR 밴드도 함께 제공하거나 모자이크 영상에 적합한 영상분류 기술을 개발할 필요가 있을 것으로 생각된다. 또한 지형특성별 분류결과 비교분석과 관심객체별 기계학습 등을 통한 영상분류 방법을 개발하는 등 관련 연구를 지속한다면, 추후 분광정보가 제한된 영상들도 활용도가 높아질 수 있을 것으로 기대된다.

RFID의 보안업무 적용환경과 적용방안에 관한 연구 (A Study on the RFID's Application Environment and Application Measure for Security)

  • 정태황
    • 시큐리티연구
    • /
    • 제21호
    • /
    • pp.155-175
    • /
    • 2009
  • 무선주파수를 이용해 직접적인 접촉 없이 사물에 부착된 태그를 식별하여 원하는 정보를 처리하는 자동인식기술인 RFID는 빠른 인식속도, 긴 인식거리, 금속을 제외한 대부분의 장애물 투과 기능 등의 특성으로 적용범위가 넓어지고 있다. 현재 125KHz, 134KHz, 13.56MHz, 433.92MHz, 900MHz, 2.45GHz 대의 주파수를 이용하여 물류, 교통, 안전 등 다양한 분야에 활용되고 있으며, 이러한 환경은 보안목적을 위해서도 유용하게 적용할 수 있는 중요한 기술적 요소가 되고 있다. RFID는 전 세계적으로 새로운 성장동력으로 각광받고 있으며, 우리나라에서도 향후 산업적으로 발전 가능성이 매우 높은 것으로 판단하여 정부차원에서 이 기술을 산업에 효과적으로 접목시키기 위하여 연구개발과제와 시범사업 등을 정책적으로 추진하고 있어 그 적용성 향상과 함께 보안업무를 위한 적용성도 높을 것으로 기대된다. RFID는 사람 및 차량에 대해 구역별로 구분하여 출입통제를 할 수 있어 기존의 통제업무를 한층 보완할 수 있을 뿐 아니라 RFID카드에 암호키를 격납하여 본인인증에 사용할 수 있다. RFID는 자기카드에 비해 보안이 강하기 때문에 주민등록증, 여권 등의 불법복제방지를 위해 이용할 수 있는데, 국제차원에서 여권 및 국제운전면허증 등에 RFID 도입을 추진하고 있는 것도 이러한 이유에서이다. 능동형 RFID는 장거리 데이터 전송이 가능하여 실시간 위치정보시스템에 적용하여 위치확인과 모니터링을 통해 사람을 보호하는 기능을 제공할 수 있고, RFID시스템이 지닌 인식 추적기능은 출입통제시스템과 연계하여 특정한 지역을 방문하는 외부인의 등록, 신분확인, 위치 확인 등의 효율적 관리와 방문자자가 불필요한 지역에 진입하는 것을 통제할 수 있으며, 반입되는 장비의 관리와 분실방지 등 체계적 운영을 위해 적용할 수 있다. RFID를 복사기에 적용하여 복사기 사용자, 복사량 등에 대해 효과적으로 관리 통제할 수 있으며, RFID 시스템과 연계된 프린터, 팩스 등의 접근통제 및 복사 내용을 감시할 수 있다. 갈수록 소형화 되고 있는 저장장치에 RFID 태그를 부착하고, RFID의 위치추적기능을 통해 물품의 무단 반출을 방지하고 물품의 반입과 반출을 효과적으로 통제할 수 있다. 기존의 출입통제시스템에서 사용하는 마그네틱 카드나 스마트카드는 출입자를 인식하고 통제하는 기능을 잘 수행했으나 물품의 반입을 통제하는 기능을 수행하지 못했다. 그러나 RFID 시스템의 무선 인식과 추적 기능은 출입통제 기능뿐 아니라 물품의 반출을 감시하고 통제할 수 있어 노트북이나 소형저장장치, 하드웨어와 같은 유형자산의 무단반출을 감시 통제하기 위해 적용할 수 있다.

  • PDF

감마선과 온열치료 병용시 세포 치사 능력 증강에 관한 실험적 연구 (Combined Effects of Gamma-irradiation and Hyperthermia on the Human Cell Lines for Various Temperatures and Time Sequences)

  • 고경환;조철구;박우윤;윤형근;류성렬;심재원;이미정
    • Radiation Oncology Journal
    • /
    • 제11권1호
    • /
    • pp.51-58
    • /
    • 1993
  • 원자력 병원 치료방사선과에서 사용 중인 극초단파 온열치료장치에 의한 온열치료시 온열치료의 적정화로 암 치료기술 향상을 도모함을 최종 목표로 하여 인체 암세포주에서 방사선과 온열에 의한 세포생존곡선의 기본적인 특징과 방사선과의 병용에 따른 치료효과의 증강을 파악하여 임상적 응용의 기초적인 근거를 확립하고자 하였다. 본 실험에서는 2개의 세포주, 즉 위 선암 세포주와 만성 골수성 백혈병 세포주를 사용하였다. 위암은 한국인에서 가장 발생빈도가 높고, 국소적으로 진행된 경우, 주위 장기의 한계선량으로 인하여 방사선 단독으로는 적용의 한계가 있어 온열치료와의 병용이 요구되며, 백혈병 세포는 방사선에 민감한 대표적인 세포의 하나로 온열치료와의 병용시 발생할 수 있는 미묘한 차이를 보다 분명히 관찰할 수 있을 것으로 기대하여 본 실험에 사용하였다. 감마선과 온열치료를 겸한 경우 두가지 방법을 동시에 시행한 경우, 치료효과가 가장 높았고 온열을 감마선 치료 후에 시행한 경우가 감마선 치료 전에 시행한 경우보다 약간 높았으나, 그 차이는 크지 않았고, 6시간 이상의 간격에서는 같았다. 온일치료의 온도 및 치료시간과 치료효과는 온도가 높을수록 치료시간이 길수록 치료효과가 높았고, $43^{\circ}C$에서는 온열내성을 시간경과에 따라볼 수 있었다. 같은 온도로 30분간 온열치료시 온열치료효과 증진비는 섭씨 43도, 44도, 45도의 경우, D 0.01을 기준으로 $2.5{\pm}0.08,\;3.75{\pm}0.18,\;5.0{\pm}0.15$였다. 본 연구는 기초 생물학적 실험이나, 이 결과는 임상 암치료에 직접 이용되는 것이며 또한 치료수행에 반드시 필요한 과정이다. 따라서, 치료방법의 결정, 성적분석, 치료 부작용의 예측 및 대책 확립 등에 적용되고 본원 온열치료의 특성 제시에 활용될 수 있다.

  • PDF

전이성 척추암 환자의 확산강조영상 검사 시 조영제 주입 전.후 ADC값의 변화에 대한 고찰 (SNR and ADC Value Change before and after the injection of contrast medium during DWI test on metastatic spinal cancer patients)

  • 김응찬;김기홍;박철수;이선엽;유흥준;조재환;장현철;김보희;한만석
    • 한국방사선학회논문지
    • /
    • 제5권1호
    • /
    • pp.37-49
    • /
    • 2011
  • 전이성 척추암 환자를 대상으로 1.5 T MR 기기에서 조영제 주입 전 후 확산강조영상에서 전이가 된 요추의 신호대 잡음비, 대조도대 잡음비, 현성 확산 계수가 어떤 변화를 나타내는지 알아보고자 하였다. 영상의 정량적 분석에서는 전이성 척추암 그룹의 경우 조영제 주입 전 확산강조영상에서 전이성 척추암이 있는 부위와 척추암이 있는 부위의 위, 아래 척추등 세 부위의 신호대 잡음비는 척추암이 있는 부위에서 낮게 나타났으며 조영제 주입 후 확산강조영상에서는 조영제 주입 전보다 세 부위 모두 신호대 잡음비가 상대적으로 증가하였으며 척추암이 있는 부위의 위, 아래 척추등 두 부위 에서는 대조도대 잡음비가 상대적으로 증가했다. ADC map영상에서는 조영제 주입 전에서 신호대 잡음비는 척추암이 있는 부위에서 높게 나타났으며 조영제 주입 후에서는 조영제 주입 전보다 전이성 척추암이 있는 부위와 척추암이 있는 부위의 위, 아래 척추등 세 부위 모두 신호대 잡음비가 상대적으로 감소했다. ADC map영상에서의 현성 확산 계수는 조영제 주입 전에서 현성 확산 계수는 척추암이 있는 부위에서 낮게 나타났으며 조영제 주입 후에서는 주입 전보다 세 부위 모두 현성 확산 계수가 상대적으로 감소했다. 정상 그룹의 경우 확산강조영상에서 요추체 3, 4, 5번 세 부위 모두 신호대 잡음비가 상대적으로 증가했고 ADC map영상에서는 조영제 주입 후 확산강조영상에서 세 부위 모두 신호대 잡음비가 상대적으로 감소했다. ADC map영상에서의 현성 확산 계수는 세 부위 모두 현성 확산 계수가 상대적으로 감소했다. 영상의 정성적 분석에서 조영제 주입 후 확산강조영상에서 전이성 척추암이 있는 부위의 신호강도가 증가하였고 ADC map영상에서는 신호강도가 감소하였다. 조영제 주입 후 확산강조영상에서 전이성 척추암이 있는 부위와 척추암이 있는 부위의 위, 아래 척추 등 세 부위 모두 신호대 잡음비와 대조도대 잡음비가 증가하고 현성확산계수가 감소하는 결과를 얻었고 조영제 주입 후 확산강조영상이 여러 가지 척추질환으로의 적용에 도움을 줄 것이라 사료된다.

수도(水稻) 재배양식(栽培樣式) 차이(差異)에 따른 잡초(雜草) 발생특성(發生特性) 연구(硏究) (Emergence and Growth of Weeds in Paddy Fields as Affected by Cropping Pattern)

  • 구자옥;권삼열
    • 한국잡초학회지
    • /
    • 제1권1호
    • /
    • pp.30-43
    • /
    • 1981
  • 본(本) 연구(硏究)는 시험전(試驗前) 일년간(一年間) 잡초방임상태(雜草放任狀態)로 수도작(水稻作)을 경작(耕作)하였던 답(畓)에 6유형(類型)의 재배양식(栽培樣式) 즉 직산파(直散播), 직조파(直條播), 기계이앙(機械移秧), 관행(慣行)손이앙(移秧), 조기이앙(早期移秧) 및 만기이앙재배법(晩期移秧栽培法)을 두고 초형(草型)과 생태특성(生態特性)이 다른 두 품종(品種) 밀앙(密%)23호(號)와 사도미노리를 공시(供試)하여 각(各) 처리(處理)의 잡초방임조건하(雜草放任條件下)에서 잡초(雜草)의 발생생태(發生生態) 특성차이(特性差異)를 파악(把握)하고저 시도(始圖)하였다. 결과(結果)를 요약(要約)하연 다음과 같다. 1. 시험지(試驗地)에서 출현(出現)한 잡초종(雜草種)은 약(約) 22종(種)으로 화본과잡초군(禾本科雜草郡)에서는 3종(種), 광엽잡초군(廣葉雜草群)에서는 13종(種), 사초과잡초군(雜草郡)에서는 6종(種)이었다. 2. 재배양식별(栽培樣式別) 잡초발생량(雜草發生量)은 직파(直播)와 조기이앙(早期移秧)에서 많았고 만기이앙(晩期移秧)에서 가장 적었으며 시기적(時期的)으로는 파종(播播) 및 이앙후(移秧後) 12주(週)에 가장 많았다. 3. 잡초군별(雜草群別) 발생량(發生量)은 사초과${\gg}$광엽류>화본과의 순(順)으로 많았으며 사초과잡초군(雜草群)의 발생량(發生量)은 직파(直播)${\gg}$조기(早期)>관행(慣行)>기계 및 만기이앙구(晩期移秧區)의 순(順)으로, 광엽잡초군은 직산파${\gg}$직조파(直條播)${\gg}$기계(機械)>관행(慣行)${\fallingdotseq}$조기(早期)${\fallingdotseq}$만기이앙구(晩期移秧區)의 순(順)으로 많았고 화본과잡초(禾本科雜草)의 경우는 사초과의 경우와 비슷하였다. 4. 화본과잡초군(禾本科雜草郡)은 생육진전(生育進展)에 따라 단일군락(單一群落)으로 집락화(集落化)하는 경향인 반면(反面) 광엽잡초군(廣棄雜草群)은 혼생군락화(混生群落化)의 경향이 인정(認定)되었고 사초과는 모든 경우에 작물품종간(作物品種種間) 차이(差異)도 없이 우점하는 경향이다. 5. 잡초군간(雜草群間)의 평균초장(平均草長)은 화본과(禾本科)>사초과>광엽류의 순(順)으로 컸으며 사초과와 광엽류잡초군의 초장(草長)은 재배양식(栽培樣式)에 따라 영향을 크게 받았다. 6. 경지내(耕地內)의 식물군간(植物群間) Importance Value변이(變異)는 화본과(禾本科)와 사초과잡초군(雜草群)이 대체(大體)로 12% 범위(範圍)였으나 사초과잡초군(雜草群)은 10~80% 범위(範圍)로써 재배양식(栽培樣式) 및 생육진전(生育進展)에 따른 변이(變異)가 컸다. 7. Simpson's Index 분석결과(分析結果), 조기(早期) 및 관행이앙(慣行移快)에서는 생육진전(生育進展)에 따라 다종혼합군락화(多種混合群落化)의 경향을 보였고 직파(直播)와 만기이앙(晩l期移快)에서는 단순군락화(單純群落化) 경향(傾向)이 나타났다.

  • PDF